Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CORROSION PROTECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Continuous Monitoring and Partial Water Softening for Cooling Tower Water Treatment

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also often used in water-cooled chilled water plants in medium to large commercial buildings. Continuous monitoring and partial water softening for cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume large amounts of water. Cooling tower-related water consumption is one of largest potable water loads within buildings in the United States, with substantial building water use associated with heating and cooling. Regional water shortages have highlighted a need to reduce water consumption; the U.S. General Services Administration (GSA) and Executive Order 13834 place priority on reducing water consumption. This priority has fueled interest in the identification, investigation, and potential broad deployment of cost-effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches use chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment; however, even when chemicals are used regularly, a certain percentage of condenser water must be drained and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste disposal issue and can cause building owners to incur additional fees, such as disposal or wastewater charges. To manage cooling tower water treatment, GSA typically contracts with a company specializing in conventional chemical maintenance for a fixed fee. While there are many types and vendors of AWT systems, this project assesses the effectiveness of one technology provided by Aqualogix. This system is a chilled water plant monitoring and control system aimed at optimizing system performance by reducing the blowdown occurrences used to remove mineral build-up. The technology consists of two components – continuous programmable logic control (PLC) monitoring and side-stream filtration with partial water softening. PLC monitoring calculates cycles of concentration (CoC) and determines the optimum amount of blowdown water required to satisfy all water chemistry requirements. Side-stream filtration removes suspended matter and improves biocide efficacy while precisely dispensing softened water to achieve optimal makeup water hardness. Unlike other AWT systems evaluated by GSA to date, this system does not replace the legacy treatment system but is used in addition to chemical water treatment. The vendor claims their technology will reduce water consumption, water discharge, and maintenance costs. The AWT system evaluated in this demonstration is a commercialized technology. Given its commercialized state, the system evaluated in this report is at a Technology Readiness Level 9 according to National Aeronautics and Space Administration (NASA) definitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrophobic, Thermal-shock Resistant Lightweight Cement Composites in Hybrid Thermal Energy-Storage Geothermal Well System

Under the DOE EERE Geothermal Technology Office (GTO)-funded project in FY 2019-2022, Brookhaven National Laboratory (BNL) aimed to develop hydrophobic thermal-shock resistant lightweight well cement composites suitable for temporarily storing a curtailed hot working fluid incurred from excess geothermal-, solar-, and wind-generated energies in underground reservoirs thermal energy storage sites. This storage energy systems are designed to provide energy during the periods between energy-harvesting and -requiring periods. One key factor to the success of this project was hydrophobicity of cement composites. The hydrophobic composites not only upgrade thermal insulating properties of water-saturated composites for minimizing heat loss in upper well surface regions, but also provide improved mechanical properties related to thermal-shock resistance and the protection of carbon steel (CS) casing against corrosion.

15 GEOTHERMAL ENERGY↗

The impact of LDEF results on the space application of metal matrix composites

Over 200 graphite/aluminum and graphite/magnesium composites were flown on the leading and trailing edges of LDEF on the Advanced Composites Experiment. The performance of these composites was evaluated by performing scanning electron microscopy and x-ray photoelectron spectroscopy of exposed surfaces, optical microscopy of cross sections, and on-orbit and postflight thermal expansion measurements. Graphite/aluminum and graphite/magnesium were found to be superior to graphite/polymer matrix composites in that they are inherently resistant to atomic oxygen and are less susceptible to thermal cycling induced microcracking. The surface foils on graphite/aluminum and graphite/magnesium protect the graphite fibers from atomic oxygen and from impact damage from small micrometeoroid or space debris particles. However, the surface foils were found to be susceptible to thermal fatigue cracking arising from contamination embrittlement, surface oxidation, or stress risers. Thus, the experiment reinforced requirements for carefully protecting these composites from prelaunch oxidation or corrosion, avoiding spacecraft contamination, and designing composite structures to minimize stress concentrations. On-orbit strain measurements demonstrated the importance of through-thickness thermal conductivity in composites to minimize thermal distortions arising from thermal gradients. Because of the high thermal conductivity of aluminum, thermal distortions were greatly reduced in the LDEF thermal environment for graphite/aluminum as compared to graphite/magnesium and graphite/polymer composites. The thermal expansion behavior of graphite/aluminum and graphite/magnesium was stabilized by on-orbit thermal cycling in the same manner as observed in laboratory tests.

Steckel, Gary L.↗

New Trends in Coatings Developments for Turbine Blades: Materials Processing and Repair

Turbine engines for aeronautic applications now have to face strenuous requirements concerning not only operating performances but also reliability and repairability. This evolution of the specifications induces important consequences regarding the choice and the design of turbine blade protective coatings. This paper presents several key features concerning the deposition techniques and the real-life behavior of such coatings: (1) complex aluminides well suited to the protection against high temperature oxidation and hot corrosion of directionally solidified nickel-base superalloy turbine blades; (2) ceramic coatings used as thermal barriers - they have to exhibit both high resistance to thermomechanical fatigue and adequate smoothness; (3) processing techniques for thermal barriers, including plasma spraying, electron beam physical vapor deposition and plasma enhanced chemical vapor deposition; and (4) blades and coatings repair techniques.

S Alpérine↗

Microstructure and electrochemical characterization of laser melt-deposited Ti{sub 2}Ni{sub 3}Si/NiTi intermetallic alloys

Corrosion and wear resistant Ti{sub 2}Ni{sub 3}Si/NiTi intermetallic alloys with Ti{sub 2}Ni{sub 3}Si as the reinforcing phase and the ductile NiTi as the toughening phase were designed and fabricated by the laser melt-deposition manufacturing process. Electrochemical behavior of the alloys was investigated using potentiodynamic polarization testing and electrochemical impedance spectroscopy in an NaOH solution. The results showed that the alloys have outstanding corrosion resistance due to the formation of a protective passive surface film of Ni(OH){sub 2} as well as the high chemical stability and strong inter-atomic bonds inherent to Ti{sub 2}Ni{sub 3}Si and NiTi intermetallics. The Ti{sub 2}Ni{sub 3}Si content has a significant influence on the microstructure of the alloys but only a slight effect on electrochemical corrosion properties.

36 MATERIALS SCIENCE↗

Internal stresses in wear and corrosion resistant amorphous metallic coatings of (W/0.6/Re/0.4/)76B24 and (Mo/0.6/Ru/0.4/)82B18

Hard protective coatings in the W-Re-B and Mo-Ru-B alloy systems have been deposited by magnetron sputtering onto soda-lime glass and heat-treated AISI 52100 steel substrates. X-ray diffraction has confirmed the amorphous nature of the as-deposited coatings, and their crystallization temperatures were determined by differential thermal analysis to be 1000 and 790 C for W-Re-B and Mo-Ru-B coatings, respectively. Both coatings exhibit high microhardness; Mo-Ru-B, in addition, has excellent corrosion resistance by comparison with pure Mo at high anodic potentials. Attention is given to the influence of internal stresses on the protective properties of the coatings deposited under different conditions.

Thakoor, A. P.↗

Combined Raman imaging and {sup 18}O tracer analysis for the study of high temperature oxidation of pre-oxidized Zircaloy-4 in spent fuel pool accident - 6.4 STP-2016-0037

Oxidation at high temperature of Zr-based cladding materials is expected to be the primary cause of the fuel assemblies' degradation in Spent Fuel Storage Pool loss of cooling accidents. Differently from Loss Of Coolant Accident (LOCA) in reactor vessel, presence of air in the atmosphere in case of a spent fuel pool accident is known to be an aggravating factor because of the 'catalytic' role of nitrogen on the oxidation. 'Low temperature' oxidation scales simulating corrosion oxide formed during normal operation have been observed to have a protective effect regarding subsequent high temperature oxidation, in steam as well as in air and air + steam atmospheres. However, in the presence of nitrogen, this protective effect is lost much earlier than in pure steam or pure oxygen. We present results on oxygen transport through such corrosion oxide layers studied using an {sup 18}O tracer technique. Experiments were performed in {sup 18}O{sub 2} alone as well as in mixed {sup 18}O{sub 2} + N{sub 2} atmospheres, at 850 deg. C, a temperature for which nitrogen is known to have a strong effect on the Zr-based alloys oxidation. Post-test investigations of the specimens were performed by means of micro-Raman profiling or imaging, giving simultaneous information on the {sup 18}O distribution and on structural factors such as composition and stresses in the scales. Raman imaging gave clear evidence for different characteristic distributions of {sup 18}O in the scales. Some of them have been correlated with the development of cracks and porosity in the oxide which allows oxygen to locally penetrate in the scales. Although nitrogen appears to have no or limited influence on the oxygen diffusion, it is observed to reach the metal/oxide interface much faster than oxygen. A mechanism explaining the role of nitrogen on the loss of the protective effect and the kinetic acceleration observed by TGA is proposed. (authors)

36 MATERIALS SCIENCE↗

Nanostructured CVD Tungsten Carbide Coating on Aircraft Actuators and Gearbox Shafts Reduces Oil Leakage and Improves Durability

Wear and corrosion of aircraft actuator parts, helicopter gearbox rotating shafts and wear of seals working against these parts can lead to oil leaks which require expensive maintenance and increase the risk of failure. The Hardide® nanostructured chemical vapor deposition (CVD) Tungsten Carbide coating was tested on metal parts working against seals as an approach to reduce oil leakage from gearboxes and actuators and increase maintenance intervals. The coating protects metal pistons and shafts from abrasion and corrosion, keeping their surface roughness parameters within optimum ranges for longer; this reduces seal wear and makes the whole unit more durable and reliable. The 50-100 micron-thick CVD Hardide coating can be applied uniformly on internal and external surfaces and has enhanced fatigue and anti-galling properties. The coating has high wear resistance outperforming Hard Chrome by 14 times and Thermal Spray WC-Co (12%) by three times. The fine-grain coating nanostructure wears uniformly so even worn Hardide coating shows no hard micro-grain asperities which are abrasive for seals. The coating is free from porosity and from Cobalt binder and is an effective barrier against corrosion. As a result the coating keeps the optimal seal-friendly surface finish for longer even in abrasive and corrosive environments. The coating was qualified by Airbus as an environmentally friendly replacement for Hard Chrome plating.

36 MATERIALS SCIENCE↗

Experimental study and effect of particulate interference on the microhardness, wear and microstructural properties of ternary doped coating

This paper studies effects of the composite particle infringement of ZnO/Cr{sub 2}O{sub 3} on zinc rich ternary based coating. The corrosion-degradation property in 3.5% NaCl was investigatedusing polarization technique. The structural characteristics of the multilayer produce coatings were evaluated by scanning electron microscope (SEM) equipped with an energy dispersive spectrometer (EDS). The mechanical response of the coated samples was studied using a diamond base Dura –Scan) micro-hardness tester and a MTR-300 dry abrasive wear tester. The combined effect of the coatings gave highly-improved performance on microhardness, corrosion and wear damage. This also implies that protection of wind-energy structures in marine environments can be achieved by composite strengthening capacity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sulphidation resistance of composite boiler tube materials

A lab-based testing program was undertaken to generate data to better define the sulphidation resistance of composite tubes installed in the lower-furnace section of black liquor recovery boilers. All composite tube cladding alloys tested were observed to have an acceptable corrosion rate at normal operating temperatures (up to 400 C) in the synthetic lower-furnace gaseous environment tested (1% H{sub 2}S-99% N{sub 2}). This acceptable corrosion resistance is due to the expected formation of a relatively protective chromium-rich inner sulphide scale. An increase in temperature up to 560 C was found to significantly increase the corrosion rate. Of the various alloys tested, Alloy HR11N exhibited the lowest corrosion rate at each of the three temperatures tested. Moreover, the corrosion rate was found not to be strongly dependent on the fabrication route (weld overlay versus co-extruded). To minimize corrosion, operating conditions that promote prolonged exposure to elevated temperatures in the lower-furnace section of black liquor recovery boilers should be avoided, regardless of the type of composite tube installed.

36 MATERIALS SCIENCE↗

Hot corrosion of ceramic engine materials

A number of commercially available SiC and Si3N4 materials were exposed to 1000 C in a high velocity, pressurized burner rig as a simulation of a turbine engine environment. Sodium impurities added to the burner flame resulted in molten Na2SO4 deposition, attack of the SiC and Si4N4 and formation of substantial Na2O-x(SiO2) corrosion product. Room temperature strength of the materials decreased. This was a result of the formation of corrosion pits in SiC, and grain boundary dissolution and pitting in Si3N4. Corrosion regimes for such Si-based ceramics have been predicted using thermodynamics and verified in rig tests of SiO2 coupons. Protective mullite coatings are being investigated as a solution to the corrosion problem for SiC and Si3N4. Limited corrosion occurred to cordierite (Mg2Al4Si5O18) but some cracking of the substrate occurred.

Fox, Dennis S.↗

Multi-Parameter Optical Fiber for Distributed Sensing of Humidity, CH4, CO2, and Corrosion

This work describes the use of the optical fiber sensor (OFS) for successful monitoring of humidity, CH4, and CO2 based on the strain produced along the single-mode fiber (SMF) sensor. This is enabled by absorption of H2O/gases onto the commercially available polyacrylate coated jacketed portion of the fiber resulting in a change in strain. Under equilibrium, a differential microstrain was observed along the jacketed portion of the SMF with N2, CH4, and CO2 at different relative humidity (RH) conditions. The strain response of the SMF under various mixed gas composition and different RH conditions were also measured and made calibration curves accordingly. Linear regression and principal component analysis of the strain datasets provided deconvolution of the impact of strain from H2O, N2, CH4, and CO2. Additionally, modified OFS comprised of the Fe coated fiber section was employed to monitor corrosion based on the increase in backscattered intensity amplitude of the light being passed once corrosion of Fe occurs. Also, corrosion of Fe was studied under soil by installing the fiber in soil with protective measures which would prevent the sensor being mechanically disturbed or broken during installation. The corrosion rates were studied by monitoring the rate at which the intensity of backscattered light amplitude attains a steady state value when complete corrosion of Fe with a specific coating thickness occurs.

Mainali, Badri↗

Superior Corrosion Resistance Properties of TiN-Based Coatings on Zircaloy Tubes in Supercritical Water

Thin films of TiN and Ti0.35Al0.65N nanocomposite were deposited on polished Zircaloy-4 tubes. After exposure to supercritical water for 48 h, the coated tubes are remarkably intact, while the bare uncoated tube shows severe oxidation and breakaway corrosion. X-ray diffraction patterns, secondary electron images, backscattered electron images, and energy dispersive X-ray spectroscopy data from the tube surfaces and cross-sections show that a protective oxide, formed on the film surface, effectively prevents further oxidation and corrosion to the Zircaloy-4 tubes. This result demonstrates the effectiveness of thin film ceramics as protective coatings under extreme environments.

36 MATERIALS SCIENCE↗

LCF Life of NiCr-Y Coated Disk Alloys After Shot Peening, Oxidation and Hot Corrosion

In a prior companion study (Ref. 1), three different Ni-Cr coating compositions (29, 35.5, 45 wt% Cr) were applied at two thicknesses by Plasma Enhanced Magnetron Sputtering (PEMS) to two similar Ni-based disk alloys. One coating also received a thin ZrO2 overcoat. The low cycle fatigue (LCF) life of each coating was determined at 760 °C and was less than that of the uncoated specimens. In this followon effort, shot peening was examined as a means to improve the as-deposited coating morphology as well as impart a residual compressive stress in the near-surface region. After evaluating the effect of the shot peening on the LCF life, the effectiveness of the shot-peened coating in protecting the disk alloy from oxidation and hot corrosion attack was evaluated. This evaluation was accomplished by exposing coated and shot-peened specimens to 500 h of oxidation followed by 50 h of hot corrosion, both at 760 °C in air. These exposed specimens were then tested in fatigue and compared to similarly treated and exposed uncoated specimens. For all cases, shot peening improved the LCF life of the coated specimens. More specifically, the highest Cr coating showed the best LCF life of the coated specimens after shot peening, as well as after the environmental exposures. Characterization of the coatings after shot peening, oxidation, hot corrosion and LCF testing is presented and discussed.

James A Nesbitt↗

Sensing and arresting metal corrosion in molten chloride salts at 800 degrees Celsius

Originally this was planned as a 5 task, 3 year project, starting in May 2019. Task 1 Detecting oxidants and metal corrosion in molten chloride salt at 800°C. Task 2 Effectiveness of Zr getter using head gas sensors of inlet and outlet gases. Task 3 Cathodic protection of metal in molten salt at reducing potential. Task 4 Find reduction potential of metals in molten chloride salts & quantum modeling. Task 5 Develop corrosion test sections integrated into molten salt flow loop. After Q4, the project was scaled back and the reorganized SOPO was reduced to 3 tasks to be completed at the end of Q7 on 01/05/2021. The 3 SOPO tasks are: Task 1 Sense oxidants and the metal corrosion in molten Na-K-Mg-Cl salt at 800°C. Task 3 Cathodically protect H230 alloy in molten Na-K-Mg-Cl salt at 800C by making H230 alloy the cathode of a power supply with a chromium-rich-metal as the anode. Task 4 Find the reduction potential of Cr metal in molten Na-K-Mg-Cl salt at 800°C. The total timeline was reduced from 12 to 7 quarters with the end date being, January 5, 2021. This amounted to task 1,3 and 4 being done in Q5,6 and 7 of an extended year 1, ending on January 5, 2021. Task 1, 3 and 4 were completed. For task1) the increase of oxidants in molten salt is detected by two things: i) a positive shift of the electrode potential for a Haynes 230 alloy (H230) metal coupon versus a silver/silver-chloride reference electrode (SSE) and ii) an increase in the corrosion rate of a H230 electrode at 800C. For task 3) applying a cathodic potential (negative overpotential) to a H230 electrode versus SSE arrested the corrosion of the cathodically protected H230 compared to an unprotected “spectator H230 electrode” in the same molten chloride salt. Lastly, for task 4) the reduction potential of chrome and chrome rich, and nickel metal electrodes were measured. The most valuable outcome of this work is that a power supply can arrest metal corrosion for metal in molten chloride salt when the power supply applies a cathodic potential to bare metal, like H230, in molten chloride salts, like ternary Mg-K-Na-chloride salt. H230 is a high strength metal for containing molten chloride salt and ternary Mg-K-Na-chloride salt is used as heat transfer fluids in concentrating solar power plants. When to use cathodic protection for protecting metal in molten chloride salts? Two scenarios are envisioned: 1) for protecting high-valued components, like solar collectors and heat exchangers and 2) for protecting the bare surface in holidays (point defects) of corrosion inhibitors that are to intended to cover the entire surface of metal.

14 SOLAR ENERGY↗

Corrosion of novel reactive silver ink and commercial silver-based metallizations in diluted acetic acid

Silver-based metallizations in photovoltaic modules are susceptible to corrosion by acetic acid generated in ethylene vinyl acetate encapsulated modules, resulting in power losses over time. Here, three silver-based metallizations are exposed to diluted acetic acid, in concentrations representative of that found in field-exposed modules. Compositional, morphological, and structural changes of the metallizations are studied over 3000 h of exposure to diluted acetic acid using Raman spectroscopy mapping, X-ray diffraction, and scanning electron microscopy. The three metallizations studied are: 1) a commercial high-temperature fire-through Ag paste, commonly used for Si diffused junction solar cells; 2) a commercial low-temperature paste normally used for silicon heterojunction cells; and 3) a novel low-temperature reactive silver ink shown to be suitable for photovoltaic applications. We find distinct corrosion rates for the high-temperature silver paste and reactive silver ink in the presence of diluted acetic acid. However, the low-temperature silver paste appears to be more corrosion resistant, likely due to a polymer layer that protects the silver particles.

36 MATERIALS SCIENCE↗

Revisiting the Corrosion of the Aluminum Current Collector in Lithium-Ion Batteries

The corrosion of aluminum current collectors and the oxidation of solvents at a relatively high potential have been widely investigated with an aim to stabilize the electrochemical performance of lithium-ion batteries using such components. The corrosion behavior of aluminum current collectors was revisited using a home-build high-precision electrochemical measurement system, and the impact of electrolyte components and the surface protection layer on aluminum foil was systematically studied. The electrochemical results showed that the corrosion of aluminum foil was triggered by the electrochemical oxidation of solvent molecules, like ethylene carbonate, at a relative high potential. The organic radical cations generated from the electrochemical oxidation are energetically unstable, and readily undergo a deprotonation reaction that generates protons and promote the dissolution of Al3+ from the aluminum foil. This new reaction mechanism can also shed light on the dissolution of transitional metal at high potentials.

Environmental Molecular Sciences Laboratory↗

New Anti-Corrosive Coatings with Resin-Bonded Polyaniline and Related Electroactive Groups

It is already known that polyaniline (an electroactive polymer) functions as a corrosion inhibitor for steel and in view of the fact that it is known to perform in the presence of hydrochloric acid, it has been considered likely that it may be useful to NASA for protecting launch structures at KSC which are exposed to not only continual ocean-side salt spray but also to hydrochloric acid at the times that solid-fuel boosters are fired. The currently used zinc-rich silicate-bonded coating is not wholly protective against the hydrochloric acid. Water pollution from zinc salts is another concern. Other earlier and concurrent NASA sponsored projects have been focussed on polyaniline specifically. Our project, administered for NASA by Dr. K. Thompson of KSC and these more-specifically polyaniline-related projects are included in a CRADA coordinated by Dr. F. Via of Akzo Nobel. A parallel project at Polytechnic under Prof K. Levon concentrated more specifically on polyaniline with various dopants. Our exploratory project reported herein was aimed at broadening the range of such corrosion inhibitors, to give protective paint compounders a wider latitude for adding corrosion inhibitors having polyaniline-like performance, and thus we diverged in several probing directions from polyaniline. Our working hypothesis was that physical variants of polyaniline, such as supported formulations on pigments or carriers, and chemical variants of polyaniline, including those having no electroconductive character, may have enhanced anticorrosion activity. We also hypothesized that small (non-polymeric) molecules having structures related to those occurring in polyaniline, may be active as corrosion inhibitors. We did preliminary testing, using an ASTM salt spray method at a nearby commercial paint testing laboratory. Our most interesting findings were that a non-electroconductive meta-isomer of polyaniline showed some corrosion activity, suggesting that the features of the polyaniline molecule associated with conductivity are not necessary for the anticorrosion action. Also, signtficantly, small molecular weight aromatic diamines and diimines resembling the reduced and the oxidized repeating unit in polyaniline showed an interesting degree of anticorrosive activity, suggesting that the polymeric feature of polyaniline is not necessary for anticorrosion action.

Weil, Edward D.↗