Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPARATIVE TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Simulation of Non-Linear Transonic Aeroelastic Behavior on the B-2

At high subsonic flight speeds, large flexible aircraft begin to encounter unsteady airloads which are not predicted by most currently available aerodynamic analysis and design methods. With increasing speed and the development of transonic flow and shocks, viscous effects quickly become very important, and flow separation can occur. The Northrop Grumman USAF B-2 Bomber encountered a nonlinear aeroelastic Residual Pitch Oscillation (RPO) under these conditions. Simulation studies were performed with the Computational Aeroelasticity Program-Transonic Small Disturbance, Viscous (CAPTSDv) computer program to evaluate its ability to predict these nonlinear aeroelastic responses. Open and closed loop simulations were performed to assess the participation of the flight control system. Control, system actuator hysteresis characteristics were modeled and found to be a significant participant in the RPO phenomenon. Simulations were also performed for varying Mach numbers and altitudes to establish the stability boundaries and compare with flight test data. These CAPTSDv simulations compared well with flight data and revealed many potential further modeling enhancements.

Residual pitch oscillation↗

Adaptive Control of Truss Structures for Gossamer Spacecraft

Neural network-based adaptive control is considered for active control of a highly flexible truss structure which may be used to support solar sail membranes. The objective is to suppress unwanted vibrations in SAFE (Solar Array Flight Experiment) boom, a test-bed located at NASA. Compared to previous tests that restrained truss structures in planar motion, full three dimensional motions are tested. Experimental results illustrate the potential of adaptive control in compensating for nonlinear actuation and modeling error, and in rejecting external disturbances.

Yang, Bong-Jun↗

Adaptive Control of Truss Structures for Gossamer Spacecraft

Neural network-based adaptive control is considered for active control of a highly flexible truss structure which may be used to support solar sail membranes. The objective is to suppress unwanted vibrations in SAFE (Solar Array Flight Experiment) boom, a test-bed located at NASA. Compared to previous tests that restrained truss structures in planar motion, full three dimensional motions are tested. Experimental results illustrate the potential of adaptive control in compensating for nonlinear actuation and modeling error, and in rejecting external disturbances.

Yang Bong-Jun↗

Use of an Expansion Tube to Examine Scramjet Combustion at Hypersonic Velocities

Combustion testing at total enthalpy conditions corresponding to flight Math numbers in excess of 12 requires the use of impulse facilities. The expansion tube is the only operational facility of its size which can provide these conditions without excessive oxygen dissociation or driver gas contamination. Expansio tube operation is described herein and the operational parameters having the largest impact on its performance are determined. These are: driver-to-intermediate chamber pressure ratio, driver gas molecular weight and specific heat ratio, and driver gas temperature. Increases in the lase named parameter will markedly affect the test section static pressure. Preliminary calibration tests are discussed and test gas conditions which have been achieved are presented. Calculated and experimental test times are compared and the parameters affecting test time are discussed. The direction of future work using this important experimental tool is indicated.

Rizkalla, Oussama↗

Compression After Impact Testing of Sandwich Structures Using the Four Point Bend Test

For many composite laminated structures, the design is driven by data obtained from Compression after Impact (CAI) testing. There currently is no standard for CAI testing of sandwich structures although there is one for solid laminates of a certain thickness and lay-up configuration. Most sandwich CAI testing has followed the basic technique of this standard where the loaded ends are precision machined and placed between two platens and compressed until failure. If little or no damage is present during the compression tests, the loaded ends may need to be potted to prevent end brooming. By putting a sandwich beam in a four point bend configuration, the region between the inner supports is put under a compressive load and a sandwich laminate with damage can be tested in this manner without the need for precision machining. Also, specimens with no damage can be taken to failure so direct comparisons between damaged and undamaged strength can be made. Data is presented that demonstrates the four point bend CAI test and is compared with end loaded compression tests of the same sandwich structure.

Nettles, Alan T.↗

Flight Test of Orthogonal Square Wave Inputs for Hybrid-Wing-Body Parameter Estimation

As part of an effort to improve emissions, noise, and performance of next generation aircraft, it is expected that future aircraft will use distributed, multi-objective control effectors in a closed-loop flight control system. Correlation challenges associated with parameter estimation will arise with this expected aircraft configuration. The research presented in this paper focuses on addressing the correlation problem with an appropriate input design technique in order to determine individual control surface effectiveness. This technique was validated through flight-testing an 8.5-percent-scale hybrid-wing-body aircraft demonstrator at the NASA Dryden Flight Research Center (Edwards, California). An input design technique that uses mutually orthogonal square wave inputs for de-correlation of control surfaces is proposed. Flight-test results are compared with prior flight-test results for a different maneuver style.

Taylor, Brian R.↗

Pre-Flight Training of Autonomic Responses for Mitigating the Effects of Spatial Disorientation During Spaceflight

The National Aeronautics and Space Administration (NASA) has identified a potential risk of spatial disorientation, motion sickness, and degraded performance to astronauts during re-entry and landing of the proposed Orion crew vehicle. The purpose of this study was to determine if a physiological training procedure, Autogenic-Feedback Training Exercise (AFTE), can mitigate these adverse effects. Fourteen men and six women were assigned to two groups (AFTE, no-treatment Control) matched for motion sickness susceptibility and gender. All subjects received a standard rotating chair test to determine motion sickness susceptibility; three training sessions on a manual performance task; and four exposures in the rotating chair (Orion tests) simulating angular accelerations of the crew vehicle during re-entry. AFTE subjects received 2 hours of training before Orion tests 2, 3, and 4. Motion sickness symptoms, task performance, and physiological measures were recorded on all subjects. Results showed that the AFTE group had significantly lower symptom scores when compared to Controls on test 2 (p=.05), test 3 (p=.03), and test 4 (p=.02). Although there were no significant group differences on task performance, trends showed that AFTE subjects were less impaired than Controls. Heart rate change scores (20 revolutions per minute minus baseline) of AFTE subjects indicated significantly less reactivity on Test 4 compared to Test 1 (10.09 versus 16.59, p=.02), while Controls did not change significantly across tests. Results of this study indicate that AFTE may be an effective countermeasure for mitigating spatial dis-orientation and motion sickness in astronauts.

Orion↗

Improved Models for Simulation of Cryogenic Spray Cooling for Propellant Tank Chilldown

This paper presents advances in spray boiling models for cryogenic fluids that exhibit strong variation in thermodynamic properties; it accounts for the interaction of the spray droplets with walls and the complex heat transfer and boiling processes that play a vital role in chilling solid surfaces. The model has been developed by corroborating and validating it with test data in liquid nitrogen obtained at the University of Connecticut. The test data includes detailed visualization and plate temperature measurements for liquid nitrogen sprays impinging on a warm test plate and subsequent transient chilldown of the plate. Simulations of transient plate chilldown in liquid nitrogen were carried out and temperature histories at various locations on the plate were compared with test measurements. The final paper will present sensitivity studies and additional comparisons with test data.

Computational Fluid Dynamics, Cryogenic, Spray Chi↗

Improved Models for Simulation of Cryogenic Spray Cooling for Propellant Tank Chilldown

This paper presents advances in spray boiling models for cryogenic fluids that exhibit strong variation in thermodynamic properties; it accounts for the interaction of the spray droplets with walls and the complex heat transfer and boiling processes that play a vital role in chilling solid surfaces. The model has been developed by corroborating and validating it with test data in liquid nitrogen obtained at the University of Connecticut. The test data includes detailed visualization and plate temperature measurements for liquid nitrogen sprays impinging on a warm test plate and subsequent transient chilldown of the plate. Simulations of transient plate chilldown in liquid nitrogen were carried out and temperature histories at various locations on the plate were compared with test measurements to demonstrate the validity of the spray boiling models that have been developed for cryogens.

Boiling↗

Improved Models for Simulation of Cryogenic Spray Cooling for Propellant Tank Chilldown

This paper presents advances in spray boiling models for cryogenic fluids that exhibit strong variation in thermodynamic properties; it accounts for the interaction of the spray droplets with walls and the complex heat transfer and boiling processes that play a vital role in chilling solid surfaces. The model has been developed by corroborating and validating it with test data in liquid nitrogen obtained at the University of Connecticut. The test data includes detailed visualization and plate temperature measurements for liquid nitrogen sprays impinging on a warm test plate and subsequent transient chilldown of the plate. Simulations of transient plate chilldown in liquid nitrogen were carried out and temperature histories at various locations on the plate were compared with test measurements to demonstrate the validity of the spray boiling models that have been developed for cryogens.

Boiling↗

THERMAL/STRUCTURAL ANALYSIS OF THE AXION QUANTUM METROLOGY CAVITY AND ITS COMPONENTS

This research was centered around maximizing the capability to cool dielectric material within a containment unit, or Photonic Band Gap (PBG) cavity, designed for detecting axion dark matter and identifying the unit’s thermal properties. There are multiple types of PBG cavities, but the latest version that axion researchers wish to use has been theorized to contain possible issues related to its thermal properties. Thermal conductivity is an issue with the dielectric material because it is made from alumina which is highly insulative. This is important since the research is being done in a cryogenic environment and the thermal noise affects the quantum bit used for detecting the axion to photon conversion process. Therefore, any improvements to this unit should be justified and implemented but are not entirely limited to thermal contact related aspects of PBG cavities. A prospect of using sapphire in place of alumina also exists, but this is a more expensive, less tested, and more elusive material to justify the creation of a full dielectric structure out of sapphire. Thermal aspects of the cavity were analyzed using finite element method (FEM) and an experiment designed to test different thermal joint materials. FEM was used to check the contraction of the cavity during cooling, the contact quality between the dielectric material and cavity wall, theheat flow rate through the assembly, and helps visualize the cavity’s reaction to different design changes. A simple comparison between thermal conductivity curves justified the usage of sapphire over alumina from a thermal property point of view. Thus, the method of experimentation had an additional dielectric material, sapphire, to test with and compare to alumina. The thermal test identified which material is best to use for a thermal joint but also simultaneously found the conductance of the joint and dielectric material as well as an estimate for what the temperature is inside the larger scale cavity since a thermometer cannot be placed inside the PBG when it cools. Initially, the cavity simulation was tested for structural deformation properties and stress distribution since it is made of copper which contracts heavily in comparison to most other materials. The reduction in volume of the cavity was less than anticipated which gave more room for a possible usage of a modified thermal joint for additional contact area and higher conductivity.

43 PARTICLE ACCELERATORS↗

Advancing Platooning with ADAS Control Integration and Assessment Test Results

The application of cooperative adaptive cruise control (CACC) to heavy-duty trucks known as truck platooning has shown fuel economy improvements over test track ideal driving conditions. However, there are limited test data available to assess the performance of CACC under real-world driving conditions. As part of the Cummins-led U.S. Department of Energy Funding Opportunity Announcement award project, truck platooning with CACC has been tested under real-world driving conditions and the results are presented in this paper. First, real-world driving conditions are characterized with the National Renewable Energy Laboratory’s Fleet DNA database to define the test factors. The key test factors impacting long-haul truck fuel economy were identified as terrain and highway traffic with and without advanced driver-assistance systems (ADAS). Track and on-highway testing guided by SAE J1321 procedures were conducted to assess truck platooning operation under the characterized real-world driving conditions. On-highway testing is done on a route in Indiana representing operation of long-haul Class 8 trucks in the United States. The road includes low-, medium-, and high-grade segments. The highway test results of a two-truck platooning configuration indicate considerable fuel-saving reduction comparing to the test track data collected under ideal driving conditions. The test data indicate that platooning could lead to increases in fuel consumption during traffic or high-grade portions of the route, causing reduction of the overall fuel saving on the road comparing to test track results. However, integration of ADAS features on the lead truck during on-road tests leads to significant improvement of fuel saving for both trucks in CACC operation.

ADAS↗

Predicting multi-wall structural response to hypervelocity impact using the hull code

Previously, multi-wall structures have been analyzed extensively, primarily through experiment, as a means of increasing the meteoroid/space debris impact protection of spacecraft. As structural configurations become more varied, the number of tests required to characterize their response increases dramatically. As an alternative to experimental testing, numerical modeling of high-speed impact phenomena is often being used to predict the response of a variety of structural systems under different impact loading conditions. The results of comparing experimental tests to Hull Hydrodynamic Computer Code predictions are reported. Also, the results of a numerical parametric study of multi-wall structural response to hypervelocity cylindrical projectile impact are presented.

Schonberg, William P.↗

The attenuation characteristics of four specially designed mufflers tested on a practical engine setup

Attenuation characteristics of four different resonator mufflers were determined in both cold tests and engine field tests and compared with the theoretical calculations. These mufflers were specifically designed for a helicopter. Engine-exhaust sound pressures, temperatures, and noise levels from the helicopter were measured. The experimental muffler cold tests indicated close a agreement with theory, whereas the engine tests indicated some discrepancies. Test results show the usefulness of the theoretical equation used for predicting muffler attenuation characteristics.

HELICOPTERS↗

Fuel cladding post-quench LOCA embrittlement: mechanical test relevance

During a loss-of-coolant-accident (LOCA), the fuel cladding is submitted to a high temperature increase in a steam environment, along with an internal pressure increase which would eventually lead to ballooning and burst of the cladding. Steam could then penetrate through the burst opening and lead to inner surface oxidation and secondary-hydriding of the cladding. Post-quench cladding rupture can then occur either in two-sided oxidized area with wall thinning due to ballooning, or in single-sided oxidized area with large hydrogen content. Common tests involved in the evaluation of the post-quench ductility are Ring Compression Tests (RCT), Expansion Due to Compression Test (EDC) or Axial Tensile Tests (AT). Questions arise about these mechanical tests, as for instance, the influence on sample failure of the oxide layer thickness partitioning between inner and outer diameter. A systematic study was carried out to compare several mechanical tests on both single-sided and two-sided Zircaloy-4 oxidized samples. Five different mechanical tests were compared, including RCT: C-shaped ring Compression Test (CCT), Axial Tensile test (AT), Ring Tensile Test with well-defined machined gage section (RTT) and plain Ring Tensile Test (pRTT). All samples were taken from cladding tubes which had been oxidized in steam at 1200 Celsius degrees and then water-quenched. Mechanical tests were performed at room temperature and two to three samples were tested for each oxidation conditions and for every sample geometry to assess the reproducibility. Metallographic examinations were carried out to measure the ZrO{sub 2} and αZr(O) layer thicknesses and the ex-β/α(O) phase fraction. Mean hydrogen content measurements were also performed systematically on each sample. Results indicate that the different mechanical tests have not the same sensitivity to the oxide layer partitioning: RTT and pRTT load at failure seems to depend mainly on the cumulated oxide layer thickness rather than on its partitioning, whereas this parameter has an impact on CCT and AT test results. For all tensile tests, stresses at failure were derived from load-displacement curves. The failure of brittle samples was assumed to be governed by linear elastic fracture mechanics. Using conventional stress intensity factor solution, a value of the material fracture toughness controlling the sample failure was determined from experimental results and discussed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement of total ultrasonic power using thermal expansion and change in buoyancy of an absorbing target

The Radiation Force Balance (RFB) technique is well established and most widely used for the measurement of total ultrasonic power radiated by ultrasonic transducer. The technique is used as a primary standard for calibration of ultrasonic transducers with relatively fair uncertainty in the low power (below 1 W) regime. In this technique, uncertainty comparatively increases in the range of few watts wherein the effects such as thermal heating of the target, cavitations, and acoustic streaming dominate. In addition, error in the measurement of ultrasonic power is also caused due to movement of absorber at relatively high radiated force which occurs at high power level. In this article a new technique is proposed which does not measure the balance output during transducer energized state as done in RFB. It utilizes the change in buoyancy of the absorbing target due to local thermal heating. The linear thermal expansion of the target changes the apparent mass in water due to buoyancy change. This forms the basis for the measurement of ultrasonic power particularly in watts range. The proposed method comparatively reduces uncertainty caused by various ultrasonic effects that occur at high power such as overshoot due to momentum of target at higher radiated force. The functionality of the technique has been tested and compared with the existing internationally recommended RFB technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of a Micro-Neutralization Test with the Rapid Fluorescent Focus Inhibition Test for Measuring Rabies Virus Neutralizing Antibodies

The rapid fluorescent focus inhibition test (RFFIT) is routinely used in the United States to measure rabies virus neutralizing antibodies (rVNA). RFFIT has a long history of reproducible and reliable results. The test has been modified over the years to use smaller volumes of reagents and samples, but requires a 50 µL minimum volume of test serum. To conduct pathogenesis studies, small laboratory animals such as mice are regularly tested for rVNA, but the minimum volume for a standard RFFIT may be impossible to obtain, particularly in scenarios of repeated sampling. To address this problem, a micro-neutralization test was developed previously. In the current study, the micro-neutralization test was compared to the RFFIT using 129 mouse serum samples from rabies vaccine studies. Using a cut-off value of 0.1 IU/mL, the sensitivity, specificity, and concordance of the micro-neutralization test were 100%, 97.5%, and 98%, respectively. The geometric mean titer of all samples above the cut-off was 2.0 IU/mL using RFFIT and 3.4 IU/mL using the micro-neutralization test, indicating that titers determined using the micro-neutralization test are not equivalent to RFFIT titers. Based on four rVNA-positive hamster serum samples, the intra-assay coefficient of variability was 24% and inter-assay coefficient of variability was 30.4%. These results support continued use of the micro-neutralization test to determine rabies virus neutralizing antibody titers for low-volume serum samples.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of Heat Transfer and Thermal Stability of Supercritical JP-7 Fuel

A series of electrically heated tube experiments was conducted to investigate the potential of JP-7 as a coolant under conditions relevant to a Mach 8 propulsion system. The heat transfer capabilities, carbon deposition, and material compatibility of JP-7 at surface temperatures up to 1700 F (927 C) were tested in 0.125 in. diameter tubes of 304 SS, Inconel 617, Haynes 188, Haynes 230, and 50150 Moly-Rhenium. The heat transfer to the coolant was modeled well by a Dittus-Boelter correlation at lower heat fluxes. At higher heat fluxes, audible instabilities were observed and corresponded to a significant enhancement in the coolant heat transfer. The carbon deposition rates in these tests were comparable to those in previous experiments at lower heat fluxes and much longer residence times. This result suggests that alternative paths of the deposition mechanism may be enhanced under high heat flux test conditions. Microscopic investigation of the post test tubes indicated that there was a significant layer of ordered carbon deposits that had not been seen in the tests at lower heat flux.

Linne, Diane L.↗