Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPACTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Influence of Compaction During Reaction Heat Treatment on the Interstrand Contact Resistances of Nb 3 Sn Rutherford Cables for Accelerator Magnets

The high field superconducting magnets required for ongoing and planned upgrades to the Large Hadron Collider (LHC) will be wound with Nb 3 Sn Rutherford cables for which reason studies of Nb 3 Sn strand, cable, and magnet properties will continue to be needed. Of particular importance is field quality. Here, the amplitudes of multipoles in the bore fields of dipole and quadrupole magnets, induced by ramp-rate-dependent coupling currents, are under the control of the interstrand contact resistances-crossing strand, R c , adjacent strand, R a , or a combination of them, R eff . Although two decades ago it was agreed that for the LHC R c should be in the range 10-30 μΩ, more recent measurements of LHC quadrupoles have revealed R c values ranging from 95 to 230 μΩ. This paper discusses ways in which these values can be achieved. In a heavily compacted cable R eff can be tuned to some predictable value by varying the width of an included stainless steel (effectively “insulating”) core. But cables are no longer heavily compacted with the result that the crossing strands of the impregnated cable are separated by a thick epoxy layer that behaves like an insulating core. If a stainless steel core is actually present, Reff must be independent of core width. Since there is no guarantee that a fixed predetermined amount of interlayer separation could be reproduced from winding to winding it would be advisable to include a full width core.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Grouper: A Compact, Streamable Triangle Mesh Data Structure

Here, we present Grouper: an all-in-one compact file format, random-access data structure, and streamable representation for large triangle meshes. Similarly to the recently published SQuad representation, Grouper represents the geometry and connectivity of a mesh by grouping vertices and triangles into fixed-size records, most of which store two adjacent triangles and a shared vertex. Unlike SQuad, however, Grouper interleaves geometry with connectivity and uses a new connectivity representation to ensure that vertices and triangles can be stored in a coherent order that enables memory-efficient sequential stream processing. We also present a linear-time construction algorithm that allows streaming out Grouper meshes using a small memory footprint while preserving the initial ordering of vertices. In this construction, we show how the problem of assigning vertices and triangles to groups reduces to a well-known NP-hard optimization problem, and present a simple yet effective heuristic solution that performs well in practice. Our array-based Grouper representation also doubles as a triangle mesh data structure that allows direct access to vertices and triangles. Storing only about two integer references per triangle-i.e., less than the three vertex references stored with each triangle in a conventional indexed mesh format-Grouper answers both incidence and adjacency queries in amortized constant time. Our compact representation enables data-parallel processing on multicore computers, instant partitioning and fast transmission for distributed processing, as well as efficient out-of-core access. We demonstrate the versatility and performance benefits of Grouper using a suite of example meshes and processing kernels.

97 MATHEMATICS AND COMPUTING↗

Optimization of radiography applications using x-ray beams emitted by compact accelerators. Part I. Monte Carlo study of the hard x-ray spectrum

Purpose: A 3-year project called LABSYNC has been recently funded by the European Commission, with the aim of designing a radiation facility based on a compact light source, i.e., a laboratory-sized commercial synchrotron, capable of accelerating electrons up to 6 or 20 MeV. An accurate spectral description of hard x rays emitted from thin targets, irradiated by electron beams circulating in the storage ring, is of primary interest for the design and the characterization of a beamline. This article, Part I, aims at optimizing some of the parameters which are critical for the design of medical applications based on the above compact light source. The goal was to evaluate the dependence of photon fluence and beam monochromaticity on electron-beam energy, target material, and thickness. Methods: The transport of 6 and 20 MeV electrons in a thin molybdenum, rhodium, and tungsten target is studied by means of Monte Carlo simulations using MCNPX. Configurations of the x-ray output port, different from the default forward-directed emission of the beam, are also investigated. A comparison with reference spectra for general diagnostic radiology and mammography is carried out. Results: It is shown that the emitted x-ray beams can be far more intense than those generated by conventional x-ray tubes for radiography applications. The profiles of the calculated polychromatic spectra resemble those generated by conventional x-ray tubes, with x-ray energies up to the energy of the incident-electron beam. An appreciable improvement in the monochromaticity of the beams can be obtained by viewing the x-ray emission from an output port antiparallel to the direction of the incident-electron beam. Conclusions: The optimum target thickness for tungsten target spectra is practically constrained by a trade-off between bremsstrahlung efficiency and focal-spot size requirements. A larger margin for optimization of target thickness is probably available for mammographic spectra. The constraint of a backward-directed (or, to a lesser extent, orthogonal) output port is to be considered mandatory for minimizing the high-energy tail of the spectral distribution and keeping the radiation dose to a reasonable level. It is also fundamental to evaluate the impact of the high-energy tail of the emitted spectra in x-ray imaging applications, since the energy range involved is significantly beyond the diagnostic range. This topic will be dealt with in Part II of the article.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-BRE-07: Neutron Shielding Assessment for a Compact Proton Therapy Vault

Purpose: To perform a neutron shielding assessment of a commercially available compact proton therapy system. Methods: TOPAS (TOol for PArticle Simulation) beta release was used to model beam line components for Mevion S250 proton treatment system the design of which is that the cyclotron is present in the treatment room. Three neutron production sources were taken into account in the simulation. These are the cyclotron, the treatment nozzle and the patient itself, respectively. The cyclotron was modeled as a cylindrical iron target (r =5 cm, length = 8 cm). A water phantom (10 cm ×10 cm ×60 cm) was used to model the patient and various structures (scattering foils, range modulator wheel, applicator and compensator) defaulted in TOPAS were used to model the passive scattering treatment nozzle. Neutron fluences and energy spectra were counted in a spherical scoring geometry per incident proton in 18 angular bins (10 degree each). Fluence to dose conversion factors from ICRU publication 74 were used to acquire neutron ambient dose equivalent H*(10). A point source line of sight model was then used to calculate neutron dose at eight locations beyond shielding barriers. Results: The neutron ambient dose equivalent was calculated at the 8 points of interest around the proton treatment vault. The highest dose was found to be less than 0.781 mSv/year outside south barrier wall. However, the dose is less than 0.05 mSv/year at the control room area of the proton vault. Conclusion: All Points of interest were well under annual dose limits. This suggests that the shielding design of this compact proton therapy system is sufficient for radiation protection purpose. However, it is important to note that the workload and the occupancy factors are direct multipliers for dose calculations beyond the barrier and must be accurately estimated for validation of our results.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-568: Neutron Dose Survey of a Compact Single Room Proton Machine

Purpose: To ensure acceptable radiation limits are maintained for those working at and near the machine during its operation, a comprehensive radiation survey was performed prior to the clinical release of Mevion S250 compact proton machine at Stephenson Oklahoma Cancer Center. Methods: The Mevion S250 proton therapy system consists of the following: a superconducting cyclotron to accelerate the proton particles, a passive double scattering system for beam shaping, and paired orthogonal x-ray imaging systems for patient setup and verification via a 6D robotic couch. All equipment is housed within a single vault of compact design. Two beam delivery applicators are available for patient treatment, offering field sizes of as great as 14 cm and 25 cm in diameter, respectively. Typical clinical dose rates are between 1 and 2 Gy/min with a fixed beam energy of 250 MeV. The large applicator (25 cm in diameter) was used in conjunction with a custom cut brass aperture to create a 20 cm x 20 cm field size at beam isocenter. A 30 cm − 30 cm − 35 cm high density plastic phantom was placed in the beam path to mimic the conditions creating patient scatter. Measurements integrated-ambient-neutron-dose-equivalence were made with a SWENDII detector. Gantry angles of 0, 90 and 180 degrees, with a maximum dose rate of 150 MU/min (for large applicator) and beam configuration of option 1 (range 25 cm and 20 cm modulation), were selected as testing conditions. At each point of interest, the highest reading was recorded at 30 cm from the barrier surface. Results: The highest neutron dose was estimated to be 0.085 mSv/year at the console area. Conclusion: All controlled areas are under 5 mSv/year and the uncontrolled areas are under 1 mSv/year. The radiation protection provided by the proton vault is of sufficient quality.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-H-BRA-02: The Physics of Magnetic Field Isolation in a Novel Compact Linear Accelerator Based MRI-Guided Radiation Therapy System

Purpose: To develop a method for isolating the MRI magnetic field from field-sensitive linear accelerator components at distances close to isocenter. Methods: A MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. In order to accomplish this, the magnetron, port circulator, radiofrequency waveguide, gun driver, and linear accelerator needed to be placed in locations with low magnetic fields. The system was also required to be compact, so moving these components far from the main magnetic field and isocenter was not an option. The magnetic field sensitive components (exclusive of the waveguide) were placed in coaxial steel sleeves that were electrically and mechanically isolated and whose thickness and placement were optimized using E&M modeling software. Six sets of sleeves were placed 60° apart, 85 cm from isocenter. The Faraday effect occurs when the direction of propagation is parallel to the magnetic RF field component, rotating the RF polarization, subsequently diminishing RF power. The Faraday effect was avoided by orienting the waveguides such that the magnetic field RF component was parallel to the magnetic field. Results: The magnetic field within the shields was measured to be less than 40 Gauss, significantly below the amount needed for the magnetron and port circulator. Additional mu-metal was employed to reduce the magnetic field at the linear accelerator to less than 1 Gauss. The orientation of the RF waveguides allowed the RT transport with minimal loss and reflection. Conclusion: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of creating low magnetic field environments for the magnetic-field sensitive components, has been solved. The measured magnetic fields are sufficiently small to enable system integration. This work supported by ViewRay, Inc.

60 APPLIED LIFE SCIENCES↗

HU multimerization shift controls nucleoid compaction

Molecular mechanisms controlling functional bacterial chromosome (nucleoid) compaction and organization are surprisingly enigmatic but partly depend on conserved, histone-like proteins HUαα and HUαβ and their interactions that span the nanoscale and mesoscale from protein-DNA complexes to the bacterial chromosome and nucleoid structure. We determined the crystal structures of these chromosome-associated proteins in complex with native duplex DNA. Distinct DNA binding modes of HUαα and HUαβ elucidate fundamental features of bacterial chromosome packing that regulate gene transcription. By combining crystal structures with solution x-ray scattering results, we determined architectures of HU-DNA nucleoproteins in solution under near-physiological conditions. These macromolecular conformations and interactions result in contraction at the cellular level based on in vivo imaging of native unlabeled nucleoid by soft x-ray tomography upon HUβ and ectopic HUα38 expression. Structural characterization of charge-altered HUαα-DNA complexes reveals an HU molecular switch that is suitable for condensing nucleoid and reprogramming noninvasive Escherichia coli into an invasive form. Collective findings suggest that shifts between networking and cooperative and noncooperative DNA-dependent HU multimerization control DNA compaction and supercoiling independently of cellular topoisomerase activity. By integrating x-ray crystal structures, x-ray scattering, mutational tests, and x-ray imaging that span from protein-DNA complexes to the bacterial chromosome and nucleoid structure, we show that defined dynamic HU interaction networks can promote nucleoid reorganization and transcriptional regulation as efficient general microbial mechanisms to help synchronize genetic responses to cell cycle, changing environments, and pathogenesis.

59 BASIC BIOLOGICAL SCIENCES↗

A hot and fast ultra-stripped supernova that likely formed a compact neutron star binary

Compact neutron star binary systems are produced from binary massive stars through stellar evolution involving up to two supernova explosions. The final stages in the formation of these systems have not been directly observed. Here, we report the discovery of iPTF 14gqr (SN 2014ft), a type Ic supernova with a fast-evolving light curve indicating an extremely low ejecta mass (≈0.2 solar masses) and low kinetic energy (≈2 × 10 50 ergs). Early photometry and spectroscopy reveal evidence of shock cooling of an extended helium-rich envelope, likely ejected in an intense pre-explosion mass-loss episode of the progenitor. Taken together, we interpret iPTF 14gqr as evidence for ultra-stripped supernovae that form neutron stars in compact binary systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Compact Stars with Modified Gauss–Bonnet Tolman–Oppenheimer–Volkoff Equation

We study compact stars for f(G) gravity model using modified Tolman–Oppenheimer–Volkoff equation. Firstly, the hydrostatic equilibrium equations have been developed in the context of f(G) gravity. Secondly, the profiles of energy density, pressure and mass of stars are investigated through two different equations of state models, p = ωρ{sup 5/3} and p = a(ρ – 4b), ρ being the energy density, ω, a and b are the specific constants. For f(G) = αG{sup 2} model with α being an arbitrary constant, the physical attributes of the compact objects have been discussed for the different values of model parameter α. It is concluded that in the framework of f(G) gravity, neutron and strange stars follow physically accepted patterns and the results agree with those already available in literature.

79 ASTRONOMY AND ASTROPHYSICS↗

Insights into the thermo-hydraulic properties of compacted MX80 bentonite during hydration under elevated temperature

In high-level radioactive waste geological repositories, compacted bentonite undergoes coupled thermo-hydraulic processes due to heat released from a central waste canister and groundwater imbibition from the surrounding host rock. An understanding of these processes is essential for long-term simulations of radionuclide migration and canister corrosion, which requires an understanding of temperature effects on the coupled thermo-hydraulic properties governing these processes. In this study, a tank-scale radial infiltration test was used to investigate water imbibition processes in compacted bentonite under a central heater temperature of 200 °C that simulates high thermal gradients in a repository. Interpretation of this test focuses on evaluation of the liquid water wetting front during hydration and the interpretation of the temperature-dependent transient soil water retention curve (SWRC), thermal conductivity function (TCF), and hydraulic conductivity function (HCF). The SWRC during imbibition follows a temperature-dependent wetting path. Temperature effects on the hydraulic conductivity of bentonite in saturated conditions had the greatest effect on the shape of the HCF, with minimal temperature effects at higher suctions. The transient thermal conductivity data matched well with a new TCF linked with the SWRC shape. Although the bentonite layer was restrained, local deformations during hydration may have affected the shapes of the TCF and HCF.

Engineering↗

Performance and Molière radius measurements using a compact prototype of LumiCal in an electron test beam

A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear e \(^{+}\) e \(^{-}\) collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY with an electron beam of energy 1–5 GeV. The performance of a prototype of a compact LumiCal comprising eight detector planes was studied. The effective Molière radius at 5 GeV was determined to be (8.1 ± 0.1 (stat) ± 0.3 (syst)) mm, a value well reproduced by the Monte Carlo (MC) simulation (8.4 ± 0.1) mm. The dependence of the effective Molière radius on the electron energy in the range 1–5 GeV was also studied. Good agreement was obtained between data and MC simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TCAD-Machine Learning Enabled TID Compact Model Development for Commercial SiC MOSFET

We propose a TCAD (Technology Computer Aided Design)-machine learning coupled approach that combines a TCAD tool (Charon), optimization/uncertainty quantification tool (Dakota), surrogate models, and Bayesian learning capabilities. The coupling approach is used for accurate modeling and calibration of total ionizing dose (TID) induced threshold voltage (V th ) shifts in Commercial-Off-The-Shelf (COTS) semiconductor devices and to develop physics-informed TID compact models. This versatile approach is applied to model the TID effect in an exemplar COTS 3.3 kV SiC power MOSFET (Metal-Oxide-Semiconductor Field-Effect Transistor). With the Charon-Dakota coupling, we can determine key device geometry and doping values based on device physics, which are difficult to obtain or not available for COTS devices but important for TCAD simulation; additionally, we can efficiently generate thousands of simulation results in a large parameter space, which makes it possible to develop data-driven surrogate models and perform Bayesian calibration. Utilizing the full tool-coupling approach, we achieve calibrated TCAD simulation models that accurately capture the average TID-induced V th shifts behavior with total doses and V th shifts saturation at high doses as observed in experimental data. More importantly, the calibrated TCAD simulations are obtained with determined TID model parameters (e.g., hole trap density and capture cross section) values that contain well quantified uncertainties. Furthermore, we can isolate and quantify the noises that are not captured by the TCAD models but exist in the measured data due to measurements and devices variabilities. Lastly, the calibrated surrogate models are used to develop physics-informed TID compact models. The method is generalizable to other devices and/or radiation conditions with few modifications and can provide well-determined uncertainties.

COTS↗

Compact intermediates in RNA folding

Large noncoding RNAs fold into their biologically functional structures via compact yet disordered intermediates, which couple the stable secondary structure of the RNA with the emerging tertiary fold. The specificity of the collapse transition, which coincides with the assembly of helical domains, depends on RNA sequence and counterions. It determines the specificity of the folding pathways and the magnitude of the free energy barriers to the ensuing search for the native conformation. By coupling helix assembly with nascent tertiary interactions, compact folding intermediates in RNA also play a crucial role in ligand binding and RNA-protein recognition.

59 BASIC BIOLOGICAL SCIENCES↗

Compact steady-state tokamak performance dependence on magnet and core physics limits

Compact tokamak fusion reactors utilizing advanced high-temperature superconducting magnets for the toroidal field coils have received considerable recent attention due to the promise of more compact devices and more economical fusion energy development. Facilities with combined Fusion Nuclear Science (FNS) and Pilot Plant missions to provide both the nuclear environment needed to develop fusion materials and components while also potentially achieving sufficient fusion performance to generate modest net electrical power are considered. The performance of the tokamak fusion system is assessed using a range of core physics and toroidal field magnet performance constraints to better understand which parameters most strongly influence the achievable fusion performance.

Low aspect ratio↗

Data for Construction of a Compact Array of Microplasma Jet Devices and Its Application for Random Mutagenesis of Rhodosporidium toruloides

A small and efficient DNA mutation-inducing machine was constructed with an array of microplasma jet devices (7 × 1) that can be operated at atmospheric pressure for microbial mutagenesis. Using this machine, we report disruption of a plasmid DNA and generation of mutants of an oleaginous yeast Rhodosporidium toruloides . Specifically, a compact-sized microplasma channel (25 × 20 × 2 mm3) capable of generating an electron density of greater than 1013 cm–3 was constructed to produce reactive species (N2*, N2+, O, OH, and Hα) under helium atmospheric conditions to induce DNA mutagenesis. The length of microplasma channels in the device played a critical role in augmenting both the volume of plasma and the concentration of reactive species. First, we confirmed that microplasma treatment can linearize a plasmid by creating nicks in vitro. Second, we treated R. toruloides cells with a jet device containing 7 microchannels for 5 min; 94.8% of the treated cells were killed, and 0.44% of surviving cells showed different colony colors as compared to their parental colony. Microplasma-based DNA mutation is energy-efficient and can be a safe alternative for inducing mutations compared to conventional methods using toxic mutagens. This compact and scalable device is amenable for industrial strain improvement involving large-scale mutagenesis.

Conversion↗

Compact single-shot soft X-ray photon spectrometer for free-electron laser diagnostics

The photon spectrum from free-electron laser (FEL) light sources offers valuable information in time-resolved experiments and machine optimization in the spectral and temporal domains. We have developed a compact single-shot photon spectrometer to diagnose soft X-ray spectra. The spectrometer consists of an array of off-axis Fresnel zone plates (FZP) that act as transmission-imaging gratings, a Ce:YAG scintillator, and a microscope objective to image the scintillation target onto a two-dimensional imaging detector. This spectrometer operates in segmented energy ranges which covers tens of electronvolts for each absorption edge associated with several atomic constituents: carbon, nitrogen, oxygen, and neon. The spectrometer’s performance is demonstrated at a repetition rate of 120 Hz, but our detection scheme can be easily extended to 200 kHz spectral collection by employing a fast complementary metal oxide semiconductor (CMOS) line-scan camera to detect the light from the scintillator. This compact photon spectrometer provides an opportunity for monitoring the spectrum downstream of an endstation in a limited space environment with sub-electronvolt energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient and compact thermo-optic phase shifter in silicon-rich silicon nitride

The design, fabrication, and characterization of low-loss ultra-compact bends in high-index (${n} = {3.1}$ at $\lambda = {1550}\;{\rm nm}$) plasma-enhanced chemical vapor deposition silicon-rich silicon nitride (SRN) were demonstrated and utilized to realize efficient, small footprint thermo-optic phase shifter. Compact bends were structured into a folded waveguide geometry to form a rectangular spiral within an area of ${65} \times {65}\;\unicode{x00B5}{{\rm m}^2}$, having a total active waveguide length of 1.2 mm. The device featured a phase-shifting efficiency of $8\;{\rm mW}/\pi$ and a 3 dB switching bandwidth of 15 KHz. Here, we propose SRN as a promising thermo-optic platform that combines the properties of silicon and stoichiometric silicon nitride.

Nejadriahi, Hani↗

Compact fiber-coupled narrowband two-mode squeezed light source

Quantum correlated states of light, such as squeezed states, are a fundamental resource for the development of quantum technologies, as they are needed for applications in quantum metrology, quantum computation, and quantum communications. It is thus critical to develop compact, efficient, and robust sources to generate such states. Here, we report on a compact, narrowband, fiber-coupled source of two-mode squeezed states of light at 795 nm based on four-wave mixing (FWM) in an 85 Rb atomic vapor. The source is designed in a small modular form factor, with two input fiber-coupled beams, the seed and pump beams required for the FWM, and two output fibers, one for each of the modes of the squeezed state. The system is optimized for low pump power (135 mW) to achieve a maximum intensity-difference squeezing of 4.4 dB after the output of fibers at an analysis frequency of 1 MHz. Furthermore, the narrowband nature of the source makes it ideal for atomic-based quantum sensing and quantum networking configurations that rely on atomic quantum memories. Such a source paves the way for a versatile and portable platform for applications in quantum information science.

Jain, Umang [University of Oklahoma, Norman, OK (U↗