Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMMERCIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Commercialization of Immobilized Amino-Siliane/Amine or Biochar Sorbents for the Capture of Carbon Dioxide from Various Methane Gas Streams [Abstract]

Currently, landfill gases are flared-off, which creates carbon dioxide (CO 2 ) and particulate matter air emissions, while still containing small amounts of unburned methane (CH 4 ). All of these pollutants contribute to environmental health hazards and global climate change. The same is true with industrial processes that use thermal technologies to process biomass, as these also generate the pollutant gases and particulates. In conjunction with BioEnegy Development (BED), NETL researchers will adapt the Basic Immobilized Amine Sorbent (BIAS) material technology for use in BED’s biorefineries. The goal of this proposed work is to develop NETL’s immobilized hydrophobic amino-silane/amine pellets in combination with BED’s biochar materials (derived from the pyrolysis of biomass) into a commercially-accepted means of capturing/recovering CH 4 and CO 2 gases from landfills. Overall, the NETL-BioEnergy Development partnership will focus on the development and application of this carbon management sorbent technology to commercial carbon capture processes and promotion of clean methane based fuel streams.

09 BIOMASS FUELS↗

Energy-Recovery Linacs for Commercial Radioisotope Production - Phase I

Most radioisotopes are produced by nuclear reactors or positive ion accelerators, which are expensive to construct and to operate. Photonuclear reactions using bremsstrahlung photon beams from less-expensive electron linacs can generate isotopes of critical interest, but much of the beam energy in a conventional electron linac is dumped at high energy, making unwanted radioactivation. The largest part of this radioactivation may be completely eliminated by applying energy recovery linac technology to the problem with an additional benefit that the energy cost to produce a given amount of isotope is reduced. Consequently a Superconducting Radio Frequency (SRF) Energy Recovery Linac (ERL) is a path to a more diverse and reliable domestic supply of short-lived, high-value, high-demand isotopes at a cost lower than that of isotopes produced by reactors or positive-ion accelerators. A Jefferson Lab approach to this problem involves a thin photon production radiator, which allows the electron beam to recirculate through rf cavities so the beam energy can be recovered while the spent electrons are extracted and absorbed at a low enough energy to minimize unwanted radioactivation. The thicker isotope photoproduction target is not in the beam. MuPlus, with Jefferson Lab and Niowave, proposed to extend this ERL technology to the commercial world of radioisotope production. In Phase I we demonstrated that 1) the ERL advantage for producing radioisotopes is at high energies (~100 MeV), 2) the range of acceptable radiator thickness is narrow (too thin and there is no advantage relative to other methods and too thick means energy recovery is too difficult), 3) using optics techniques developed under an earlier STTR for collider low beta designs greatly improves the fraction of beam energy that can be recovered (patent pending), 4) many potentially useful radioisotopes can be made with this ERL technique that have never before been available in significant commercial quantities. We developed a plan for the Phase II project that started with a Conceptual Design Report (CDR) based on the results of the Phase I studies and concluded with a Technical Design Report (TDR) for a facility to make isotopes that are most attractive based on market analyses.

07 ISOTOPE AND RADIATION SOURCES↗

Commercial Property Assessed Clean Energy (CPACE) for Tax-Exempt and Public Entities (“CivicPACE”)

This report summarizes the work of the CivicPACE team to open the market for property assessed clean energy financing for the nonprofit, tax exempt sector. Property Assessed Clean Energy (PACE) finances property improvements that are paid back through a line item on the property owner’s tax bill. Most states restrict such improvements to renewable energy and energy efficiency, although they may include water conservation and disaster related improvements such as hurricane or earthquake preparedness. When such projects are developed for commercial properties, it is referred to as commercial PACE or CPACE. When CPACE applies to tax exempt or nonprofit organizations, we refer to it as CivicPACE. CivicPACE also represents the name of this program. The purpose of the CivicPACE project was to help nonprofit tax-exempt organizations such as affordable housing, faith-based institutions, and schools gain greater access to financing for solar energy deployment through PACE. As such, the lessons learned and best practices from the CivicPACE team work is intended for state and municipal program designers, PACE administrators, solar installers, and nonprofit organizations. CPACE is experiencing rapid growth. Cumulative CPACE financing grew from 8.2 million in 2010 to 111 million in 2014 to 588 million in 2017. Renewable energy, mostly solar, represents about a quarter of the financing; the nonprofit sector represents about 10% of total financing. The Project Team was formed in early 2015 when solar financing options were limited for nonprofits (NPOs). Traditional bank financing was difficult for nonprofit organizations to secure since they are often viewed as a credit risk. Despite the growth of CPACE, few tax-exempt organizations were using the financing mechanism at the start of 2015. Nonetheless, CPACE financing appeared to have tremendous potential for solar development for tax-exempt organizations such as schools, churches, and multifamily affordable housing, because it addresses many of the traditional nonprofit financing roadblocks, such as credit risk. Given the benefits and the rapid growth of CPACE, the opportunity to expand CPACE financing for solar development on tax-exempt buildings was timely. The Project team was comprised of The Solar Foundation (TSF), Urban Ingenuity (UI), and Clean Energy Solutions, Inc. (CESI). The Solar Foundation was the Principal Investigator and overall team lead. The Solar Foundation is an independent 501(c)(3) nonprofit organization whose mission is to accelerate adoption of the world’s most abundant energy source. PACE financing specialist Urban Ingenuity was the lead for the team for the pilot projects. Clean Energy Solutions (CESI) was the lead on the market analysis, financial modeling, and HUD regulatory issues for PACE financed solar development on affordable housing. The CivicPACE team focused on four key activities to help open the market for CPACE financing of solar development for nonprofit entities: research, pilot projects, technical assistance, and information dissemination.

14 SOLAR ENERGY↗

Sensor Commercialization

The objective of this CRADA was the transfer the BaDx technology to a commercial partner, Aquila Technologies, to develop BaDx for medium-scale production. BaDx is a stand-alone, diagnostics cartridge for use in resourcelimited and challenging environments to sense low concentrations (<100 spores) of virulent pathogenic bacteria. The fully sealed cartridge also contains a “self-destruct” feature in which the device contents are sterilized post-assay. The ultimate goal of this CRADA was realized as validated and full-functioning BaDx cartridges are currently available for purchase and acquisition from Aquila. This project also resulted in significant and prestigious recognitions including, a R&D100 Award (2014), a Federal Laboratory Consortium (FLC) Excellence in Technology Transfer Award (2015), Popular Science Magazine naming BaDx ‘One of the Greatest Innovations of 2015,” and a TechConnect National Innovation Award (2015). Further, this CRADA resulted in a commercially viable bioagent detection platform transitioned from a national laboratory to industry that may significantly enhance national security by reducing the threat from biological agents that are stored and maintained in laboratories with poor safety and security protocols. Hospital, health clinic and at-home healthcare could also be revolutionized by this technology. This work has already lead to two follow-on projects, one funded by the US Department of Homeland Security (DHS), and the other by the US State Department.

47 OTHER INSTRUMENTATION↗

Commercial Building Technology Demonstration (Final Scientific/Technical Report)

The background for this project was a unique and innovative concept that had been proposed and demonstrated by enVerid Systems, reducing the energy consumption in HVAC systems in commercial and public buildings by up to 50% at peak loads. The concept involves selective scrubbing of gas contaminants from indoor air as a practical substitute for outside air ventilation, the latter being the conventional practice today. This scrubbing enables recycling of most of the indoor air and significantly decreasing the amount of outside air, resulting in a reduced HVAC load and commensurate energy savings for the facility. Key to our approach is low cost scrubbing of all gas contaminants from indoor air using novel, efficient and regenerable sorbent materials. The total solution, labeled HLR (HVAC Load Reduction) is implemented by means of compact modules that can be retrofitted onto virtually any building, and utilizes novel sorbents that have been developed and brought to scale production by enVerid. Although the technology had been deployed and demonstrated, the US commercial building and HVAC markets, famously conservative with respect to innovation and new technologies, had yet to embrace the idea or the product. The overarching goal of the project was to help overcome market hesitancy and enable widespread adoption, by creating a critical mass of success stories across different regions and building types, all under oversight and verification of the DOE and NREL, to ensure credibility and accuracy. The project, overall, was a resounding success. Several installations were deployed and tested comprehensively for the impact on both energy consumption and indoor air quality, and results were not only excellent, but quantitatively in line with expectations. A total number of eight (8) installations were attempted, with 2 aborted due to building issues. Of the six successful installations, however, complete M&V was performed by NREL on 2 (Miami and NYC) and partial analysis on a third site (ArcBest), and these three, along with their results, were therefore presented from a financial and reporting standpoint. Although the number of case studies fell short of the original target of 10, we nevertheless had excellent demonstrations in vastly different climate zones: Southeast, Northeast and Midwest, and in very different building types. This included a modern high-rise office building in New York City and a University Campus health center in Miami, and a mid-rise high-density office in Arkansas. The cooling load reduction was shown to be significant, averaging 37% during the final cooling season in the Miami site. In the NYC site, the cooling energy savings were generally less, at around 12%, as expected. While this is a lower number for average/total savings, two comments are important to note: (i) the outside airflow (OA) reduction was not consistent during the data collection period, at least in part understating the attainable savings through incorrect measurement of the “high energy” reference state; and (ii) the peak impact in NYC is almost certainly as high as Miami, with critical ramifications for peak load reduction and equipment downsizing ability. Importantly, the measured energy savings in all locations were related to the outdoor climate conditions and the actual achievable reduction in outside air, very much in line with models and calculations; this leaves us with increased confidence in our understanding of the interaction between the technology and the building, and our ability to project the impact of this innovation in the future, through broad adoption. Simply put: the energy savings and load reduction impact of the HLR solution has been confirmed quantitatively. The results also confirmed the air quality objective. This may be even more significant, in that air quality is more complex and harder to measure and quantify, and the performance of the HLR as an air scrubber is the linchpin of the entire solution. In all sites, indoor air quality met or exceeded the required parameters, in terms of achieving the target (low) levels of indoor pollutants. Furthermore, the concentrations of outdoor sourced pollutants were markedly lower, as expected, mostly due to the reduction in outside air intake although in part also due to the scrubbing. The success was not immediate nor easy, and early challenges with the systems, especially (but not only) around controls and communication, caused delays in commissioning and undermined some of our M&V schedules. The good news is no fundamental issues were encountered and the number of such glitches was declining quickly by the end of the project. Other challenges had to do with coordinating the control of the building OA dampers, which the HLR needs to have in order to deliver the load reduction, but which the facility manager controls regularly and independently. This is not necessarily a problem for normal HLR operation but interferes with accurate M&V, where switching OA settings back and forth on a precise timetable is essential for clean data. The project provided valuable experience in retrofitting buildings that had been originally designed to operate with less recirculation and more outside air, and some key learnings related to the cyclical regeneration of the sorbents in the operational environment of the building. Some of these learnings gave already been incorporated into ongoing improvements in the design of the HLR module as well as the software that is used to control its operation. The cost and time of retrofit installations is much better understood; so is the test and balance procedure of the building that determines the available range of outside air reduction, which in turn determines the amount of load reduced. We had also implemented at least one annual cycle of sorbent cartridge replacement in the field, after which we tested the used sorbent to assess the rate of degradation of sorbent potency – an important factor affecting the long-term economics of HLR deployments. A notable shortfall of the project, other than the fact that the number of sites was below target, was that we had not (yet) completed testing to measure and verify (M&V) the winter energy savings. This is primarily due to late start on the NYC sites (Miami does not portend any heating savings associated with reduced outside air), combined with the issues of OA damper control. It is by no means suggested that such savings cannot be captured, only that the M&V with respect to winter in NYC has been incomplete. The value of this project and its interest to the general public are hard to overstate. The case studies created from Miami and especially from NYC have, without a doubt, opened up the interest of the broad HVAC industry to HLR in the past year. Major manufacturer reps have signed up to represent and promote the product, and dozens of top tier engineering consultants have introduced HLR as a base of design in upcoming construction and renovation projects – precisely the overarching goal of this project. These would not have happened without the highly visible installation in NYC and its ultimately satisfied customer. Furthermore, the DOE itself issued a report in late 2017 analyzing hundreds of candidate technologies for reducing energy consumption in HVAC; remarkably, the budding HLR solution ranked among the top 3(!); no doubt, its status as a viable and significant contender on this list is informed by the success of these demonstrations. And furthermore, in the wake of these demos, several major energy utilities, led by ConEdison in NYC, have endorsed the HLR solution and now routinely provide substantial cash rebates for customers choosing to incorporate the HLR in their buildings and reap the benefit of the reduced peak load as well as reduced cumulative energy demand. Last but not least, in January of 2019, as this report was being written, the HLR module won the AHR Expo Innovation Award for Green Buildings and, remarkably, the prestigious and only Product of the Year 2019, being selected by an independent professional panel of judges from AHR and ASHRAE. Given the confirmation of the enormous energy saving potential of HLR in widescale deployment, as well as ancillary but significant benefits in terms of equipment downsizing and indoor air quality, the benefit of this effort to the public speaks for itself. Accelerating adoption of HLR, without dependence on subsidies and driven by the private sector, is well under way. There is still much work to be done in terms of educating the HVAC and construction ecosystems and improving the product’s robustness and simplicity, to further facilitate the adoption of this technology and the capture of its potential value. But the American public will greatly benefit both directly and indirectly in the immediate future and beyond.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cooperative Development of NETL Electrode Engineering Process for SOFC Commercialization (Final Report)

The objectives of the proposed work are to mature the NETL electrode engineering technique to enhance the activity and stability of tubular solid oxide fuel cell (SOFC) cathode electrodes in a cost-effective way and to demonstrate its commercial viability through SOFC stack testing. These overall objectives were realized through the following goals: 1) Reduction of baseline area-specific resistance (ASR) of tubular SOFC cathodes; 2) Mitigation of the long-term (>2000 h) degradation rate of tubular SOFC cathodes; 3) Demonstration of SOFC stack operation for commercially acceptable efficiency and performance.

30 DIRECT ENERGY CONVERSION↗

Water Ingress Testing of Commercially Available Containers for the TA-55 Criticality Safety Program

This memorandum outlines the water ingress test results for several commercially available container types that are advertised as “leak tight” but need to be tested to the water resistant criteria set forth by the TA-55 Criticality Safety Program. The usage of SAVY-4000 containers as water resistant containers inside gloveboxes, although allowed, is expensive, ergonomically challenging, and could be avoided if there is a commercial alternative that meets the water ingress criterion. The contents of this document are strictly for TA55 Criticality Safety Requirements (PA-RD01009), and it is not to be used to assign a damage ratio for the reduction of material at risk or implementation in the documented safety analysis. The NMCC will proceed as identified under PA-DOP-0091, and will be invoked as the review and approval control regarding usage of these containers in the facility.

61 RADIATION PROTECTION AND DOSIMETRY↗

Demonstration of Micro-Combined Heat and Power for Light Commercial Applications (Final Report)

In 2014 the United States Department of Energy (DOE) Building Technologies Office (BTO) funded a technology assessment of micro Combined Heat and Power (µCHP) systems for light commercial applications. The technology assessment was part of the BTO High Impact Technology (HIT) Catalyst program. The HIT Catalyst program supports research and development into technologies that will yield cost-effective, efficient buildings. It is estimated µCHP in US has the potential to save 10.5 GW of primary energy in the commercial building sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Low Cost, Robust and Durable Cathode Materials to Support Solid Oxide Fuel Cell Commercialization (Final Technical Report)

The project is aimed at addressing critical issues related to chromia-poisoning in the cathode of solid oxide fuel cells. A technical hurdle to the commercialization of solid oxide fuel cells is that chromia sources from the metallic interconnect and the balance of plant (BoP) components will cause chromia-poisoning to the cathode performance. This presents a significant challenge since it is very difficult to eliminate chromia sources in the cathode environment. One aspect of the current project is to evaluate whether SFM (Sr 2 Fe 1.5 Mo 0.5 O 6-δ ) that we have recently developed as redox-stable mixed conducting oxide possesses tolerance to chromia-poisoning. The second focus of this project is to evaluate coating on the cathode materials to mitigate chromia poisoning effect. Both thermodynamic evaluation and experimental approaches have been applied to enhance the knowledge base and fundamental understanding of chromia-tolerance of cathode for solid oxide fuel cells. low cost, robust and durable cathode material to support SOFC commercialization.

30 DIRECT ENERGY CONVERSION↗

FY19 Status Report on Creep Test Data on Commercial Heat of Alloy 790

This report provides an update on the status of the creep rupture testing on the first commercial heat of Alloy 709 in support of the Alloy 709 Code Case development. The report is a Level 3 deliverable in FY19 (M3AT-19AN020502041), under the Work Package AT19AN0205204, “A709 Code Case Testing” performed by Argonne National Laboratory (ANL), as part of the Advanced Reactor Technologies Program. A creep test laboratory has been set up at ANL that comprises of 15 indirectly loaded test frames capable of testing ASTM standard-size specimens of the commercial heat of Alloy 709. The systems are equipped with high temperature furnaces capable of operation up to 1000°C in an air environment. In FY19, 15 creep-rupture tests of the ESR-1100°C solution annealed material, requiring the use of Type K thermocouples, were initiated to support the 100,000-hour Code Case. At the time of writing this report, eight tests were completed. This report presents the data from those completed tests and also microstructural characterization of the fractured specimens. During FY19, efforts were being made to add Type S thermocouples to five of the creep test frames, for performing longer term tests at higher temperatures.

36 MATERIALS SCIENCE↗

ION Engineering Commercial Carbon Capture Design & Costing (C3DC) (Final Report)

ION Engineering LLC (ION) has coupled its proven, solvent-based CO 2 capture technology with an exceptionally qualified design and engineering team to complete a pre FEED for a 300-megawatt equivalent commercial-scale CO 2 capture plant for Gerald Gentleman Station’s (GGS) Generation Unit 2 (GGS2). The remarkable team was comprised of ION, Nebraska Public Power District (NPPD), Sargent & Lundy (S&L) with continued support from Koch Modular Process Systems (KMPS), and Siemens. The overall objective of the project was to provide the engineering design and cost estimate at an American Association of Cost Engineers (AACE) Class 3 estimate, resulting in accuracy ranges of -20 to +30% for the capital cost estimate. The project team was successful in completing this objective and was able to overcome the challenges that were presented during the process. A conservative interest rate of 7.0% with a financing term of 20 years was used based on interest rates utilized by S&L for this level of study. The resulting annualization factor is multiplied by the total EPC cost to calculate an annualized capital expenditure. It is estimated that the carbon capture facility treating a 300 MWe slipstream will capture 1.9 million tonnes per year of CO 2 at a capacity factor of 85%. The resulting cost of capture for the CO 2 island was determined to be $\$$36.55/tonne. Utilizing an interest rate of 4.5%, supported by historical rates for previous large capital projects in the power industry, reduces the cost of capture to $32.52/tonne. These cost of capture numbers continue to further ION’s case for commercial deployment of ION’s solvent technology.

20 FOSSIL-FUELED POWER PLANTS↗

Commercialization of the Sandia Cooler (Final Report)

This Technology Commercialization Fund (TCF) project was a complete success. As described in our original TCF proposal, TRL1 through TRL5 development of Sandia Cooler technology was carried out under EERE BTO and Sandia LDRD funding. The objective of this TCF project was for Sandia National Labs and commercial partner Wakefield-Vette to convert this TRL5 DOE technology to a market-ready, cost-competitive, electronics thermal management product (TRL 8). A further objective was to target an energy sector application with high-visibility that can effectively serve as an advertisement for DOE's Sandia Cooler technology.

42 ENGINEERING↗

Implementation of Energy Code Controls Requirements in New Commercial Buildings

This study used a three-step process to evaluate the degree to which high-impact controls requirements included in commercial energy codes are realizing their savings potential. The three-step process included: (1) interviews of commissioning agents; (2) field audits of a sample of commercial buildings to determine how well control measures are being designed, commissioned and correctly implemented; and (3) analysis of the information gathered.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy and Energy Cost Savings Analysis of the 2018 IECC for Commercial Buildings

This report provides an assessment as to whether new buildings constructed to the commercial energy-efficiency provisions of the 2018 IECC would save energy and energy costs as compared to the 2015 IECC. The Commercial Energy Efficiency chapter in the 2018 IECC allows users to either follow the provisions in the IECC or use Standard 90.1-2016 as an alternative compliance path. PNNL also compared the energy performance of the 2018 IECC with the corresponding Standard 90.1-2016 to help states and local jurisdictions make informed decisions regarding model code adoption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Sensitivity of Infrastructure Sectors to the Disruption of Commercial Electric Power

Electric power is crucial to the function of other infrastructures, as well as to the stability of the economy and the social order. Disruption of commercial electric power service, even for brief periods of time, can create significant consequences to the function of other sectors, and make living in some environments untenable. This analysis, conducted in 2017 for the United States Department of Energy (DOE) as part of the Grid Modernization Laboratory Consortium (GMLC) Initiative, focuses on describing the function of each of the other infrastructure sectors and subsectors, with an eye towards those elements of these sectors that depend on primary electric power service through the commercial electric power grid. It leverages the experience of Sandia analysts in analyzing historical disruptive events, and from the development of capabilities designed to identify the physical, logical, and geographic connectivity between infrastructures. The analysis goes on to identify alternatives for the provision of primary electric power service, and the redundancy of said alternatives, to provide a picture of the sector’s ability to withstand an extended disruption.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Update on the Simulation of Commercial Drying of Spent Nuclear Fuel

The purpose of this report is to document improvements in the simulation of commercial vacuum drying procedures at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates additional, well-designed investigations of drying process efficacy and water retention. Scaled tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Industry-Average Performance for Components and Initiating Events at U.S. Commercial Nuclear Power Plants: 2020 Update

This report documents the quantitative results of the current industry-average performance for components and initiating events (IEs) at U.S. commercial nuclear power plants (NPPs). It represents the third update of the original analysis in NUREG/CR-6928 with data through 2020. Continuous characterization and updating of current industry-average performance with the latest industry data available are important steps in maintaining up-to-date risk models. Typically, data from 1998–2002 were used in NUREG/CR-6928, data from 1998–2010 in the first update, data from 1998–2015 in the second update, and data from 2006–2020 in this update, although many IEs required longer periods for adequate characterization of frequencies in all these analyses. As with NUREG/CR-6928 and previous updates, four types of events are covered in this report: component unreliability (e.g., a pump that fails to start or fails to run), component or train unavailability resulting from test or maintenance outages, special event probabilities covering operational issues (e.g., pump restarts and injection valve re-openings during unplanned demands), and IE frequencies. Results (in the form of beta distributions for failure probabilities upon demand and gamma distributions for rates) are used as inputs to the U.S. Nuclear Regulatory Commission standardized plant analysis risk models covering U.S. commercial NPPs.

99 GENERAL AND MISCELLANEOUS↗

Cost Update: Commercial and Advanced Heliostat Collectors

The research team performed a detailed bottom-up manufacturing cost estimate for 2 heliostat designs: i) a commercially available design, the Stellio; and ii) an advanced heliostat design, the Drop-C. The Drop-C is designed and developed by Solar Dynamics (SD) of the United States, whilst the Stellio has been developed primarily by Schlaich Bergermann Und Partner, Sonne Gmbh (sbp) of Germany. The Stellio heliostat has been deployed at commercial scale and is being used at the Hami CSP 50-megawatt electric (MW e ) power tower plant in China. For each design, this includes all components for manufacturing and assembly in a manufacturing facility (e.g., struts and frame) using Design for Manufacturing and Assembly (DFMA), and the purchased parts (e.g., mirrors, control systems, and drives). The field-assembly and construction activities are also considered to determine the installed cost of the modelled solar fields.

14 SOLAR ENERGY↗