Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Multi-purpose 805 MHz Pillbox RF Cavity for Muon Acceleration Studies

An 805 MHz RF pillbox cavity has been designed and constructed to investigate potential muon beam acceleration and cooling techniques. The cavity can operate at vacuum or under pressure to 100 atmospheres, at room temperature or in a liquid nitrogen bath at 77 K. The cavity is designed for easy assembly and disassembly with bolted construction using aluminum seals. The surfaces of the end walls of the cavity can be replaced with different materials such as copper, aluminum, beryllium, or molybdenum, and with different geometries such as shaped windows or grid structures. Different surface treatments such as electro polished, high-pressure water cleaned, and atomic layer deposition are being considered for testing. The cavity has been designed to fit inside the 5-Tesla solenoid in the MuCool Test Area at Fermilab. Current status of the cavity prepared for initial conditioning and operation in the external magnetic field is discussed.

ACCELERATION↗

DESIGN AND PRELIMINARY TEST OF THE 1500 MHZ NSLS-II PASSIVE SUPERCONDUCTING RF CAVITY

NSLS-II is a new ultra-bright 3 GeV 3rd generation synchrotron radiation light source. The performance goals require operation with a beam current of 500mA and a bunch current of at least 0.5mA. Ion clearing gaps are required to suppress ion effects on the beam. The natural bunch length of 3mm is planned to be lengthened by means of a third harmonic cavity in order to increase the Touschek limited lifetime. Earlier work described the design alternatives and the geometry selected for a copper prototype. We subsequently have iterated the design to lower the R/Q of the cavity and to increase the diameter of the beam pipe ferrite HOM dampers to reduce the wakefield heating. A niobium cavity and full cryomodule including LN2 shield, magnetic shield and insulating vacuum vessel have been fabricated and installed. A passive SRF 3rd harmonic cavity consisting of two tightly coupled cells has been designed and fabricated for NSLS-II. Initial cold tests of this cavity are very promising. These tests have verified that the cavity frequency and mode separation between the 0 and {pi}-modes can be set at manufacture. Further, the frequency separation can be maintained over wide tuning ranges necessary for operation. Future work includes HOM damper and motorized tuner development.

3 GeV 3rd generation synchrotron↗

Cryogenic sub-system for the 56 MHz SRF storage cavity for RHIC

A 56 MHz Superconducting RF Storage Cavity is being constructed for the RHIC collider. This cavity is a quarter wave resonator that will be operated in a liquid helium bath at 4.4 K. The cavity requires an extremely quiet environment to maintain its operating frequency. The cavity, besides being engineered for a mechanically quiet system, also requires a quiet cryogenic system. The helium is taken from RHIC's main helium supply header at 3.5 atm, 5.3K at a phase separator tank. The boil-off is sent back to the RHIC refrigeration system to recover the cooling. To acoustically separate the RHIC helium supply and return lines, a condenser/boiler heat exchanger condenses the helium vapor generated in the RF cavity bath. A system description and operating parameters are given about the cryogen delivery system. The 56 MHz superconducting storage RF cavity project is making progress. The cryogenic system design is in its final stage. The helium supply lines have been tapped into the RHIC helium distribution lines. The plate-and-fin heat exchanger design is near completion and specification will be sent out for bid soon. The cold helium vapor heating system design will start soon as well. A booster compressor specification is underway. The first phase separator and transfer line design work is near completion and will be sent out for bid soon.

43 PARTICLE ACCELERATORS↗

SRF Cavity Surface Topography Characterization Using Replica Techniques

To better understand the roll of topography on SRF cavity performance, we seek to obtain detailed topographic information from the curved practical cavity surfaces. Replicas taken from a cavity interior surface provide internal surface molds for fine Atomic Force Microscopy (AFM) and stylus profilometry. In this study, we confirm the replica resolution both on surface local defects such as grain boundary and etching pits and compare the surface uniform roughness with the aid of Power Spectral Density (PSD) where we can statistically obtain roughness parameters at different scales. A series of sampling locations are at the same magnetic field chosen at the same latitude on a single cell cavity to confirm the uniformity. Another series of sampling locations at different magnetic field amplitudes are chosen for this replica on the same cavity for later power loss calculation. We also show that application of the replica followed by rinsing does not adversely affect the cavity performance.

99 GENERAL AND MISCELLANEOUS↗

Preparation and Testing of the SRF Cavities for the CEBAF 12 GeV Upgrade

Eighty new 7-cell, low-loss cell-shaped cavities are required for the CEBAF 12 GeV Upgrade project. In addition to ten pre-production units fabricated at JLab, the full set of commercially-produced cavities have been delivered. An efficient processing routine, which includes a controlled 30 micron electropolish, has been established to transform these cavities into qualified 8-cavity strings. This work began in 2010 and will run through the end of 2011. The realized cavity performance consistently exceeds project requirements and also the maximum useful gradient in CEBAF: 25 MV/m. We will describe the cavity processing and preparation protocols and summarize test results obtained to date.

43 PARTICLE ACCELERATORS↗

Preliminary Test Results from 650 MHz Single Cell Medium Beta Cavities for Project X

We have fabricated two single cell 650 MHz {beta}=0.61 cavities of a JLab design, which possibly can be used for the proposed Project X proton linac application. Both cavities were manufactured at JLab from RRR>250 niobium sheet of 4 mm thickness using standard techniques such as deep drawing, electron beam welding, buffered chemical polishing, hydrogen degassing heat treatment, high pressure ultrapure water rinsing and clean room assembly. Initially cavity no. 1 was -- after final surface treatment by buffered chemical polishing (BCP) -- measured without any provisions for stiffening. As expected, the pressure sensitivity and the Lorentz Force detuning coefficients were relatively high; however, the RF performance was very encouraging: the cavity exhibited a Q-value > 10{sup 11} at 1.6K, corresponding to a residual resistance of < 1.5 n{Omega} The initial gradient was limited to E{sub acc} ~ 18 MV/m, limited by field emission. In a subsequent test, the cavity was re-rinsed and stiffened up, resulting in a somewhat improved mechanical behavior, but no improvement in rf performance. The second cavity was also tested twice, before and after low temperature baking. The results from all tests are reported in this contribution.

43 PARTICLE ACCELERATORS↗

INVESTIGATION OF BREAKDOWN INDUCED SURFACE DAMAGE ON 805 MHZ PILLBOX CAVITY INTERIOR SURFACES

The MuCool Test Area (MTA) at Fermilab is a facility to develop the technology required for ionization cooling for a future Muon Collider and/or Neutrino Factory. As part of this research program, we have tested two 805 MHz vacuum RF cavities in a multi-Tesla magnetic field to study the effects of the static magnetic field on the cavity operation. This study gives useful information on field emitters in the cavity, dark current, surface conditioning, breakdown mechanisms and material properties of the cavity. All these factors determine the maximum accelerating gradient in the cavity. This paper discusses the image processing technique for quantitative estimation of spark damage spot distribution on cavity interior surfaces. The distribution is compared with the electric field distribution predicted by a computer code calculation. The local spark density is proportional to probability of surface breakdown and shows a power law dependence on the maximum electric field (E). This E dependence is consistent with the dark current calculated from the Fowler-Nordheim equation.

43 PARTICLE ACCELERATORS↗

Materials Analysis of CED Nb Films Being Coated on Bulk Nb Single Cell SRF Cavities

This study is an on-going research on depositing a Nb film on the internal wall of bulk Nb single cell SRF cavities, via a cathodic arc Nb plasma ions source, an coaxial energetic condensation (CED) facility at AASC company. The motivation is to firstly create a homoepitaxy-like Nb/Nb film in a scale of a ~1.5GHz RF single cell cavity. Next, through SRF measurement and materials analysis, it might reveal the baseline properties of the CED-type homoepitaxy Nb films. Literally, a top-surface layer of Nb films which sustains SRF function, always grows up in homo-epitaxy mode, on top of a Nb nucleation layer. Homo-epitaxy growth of Nb must be the final stage (a crystal thickening process) of any coatings of Nb film on alternative cavity structure materials. Such knowledge of Nb-Nb homo-epitaxy is useful to create future realistic SRF cavity film coatings, such as hetero-epitaxy Nb/Cu Films, or template-layer-mitigated Nb films. One large-grain, and three fine grain bulk Nb cavities were coated. They went through cryogenic RF measurement. Preliminary results show that the Q0 of a Nb film could be as same as the pre-coated bulk Nb surface (which received a chemically-buffered polishing plus a light electro-polishing); but quality factor of two tested cavities dropped quickly. We are investigating if the severe Q-slope is caused by hydrogen incorporation before deposition, or is determined by some structural defects during Nb film growth.

Zhao, Xin↗

Frequency-feedback cavity enhanced spectrometer

A spectrometer comprising an optical cavity, a light source capable of producing light at one or more wavelengths transmitted by the cavity and with the light directed at the cavity, a detector and optics positioned to collect light transmitted by the cavity, feedback electronics causing oscillation of amplitude of the optical signal on the detector at a frequency that depends on cavity losses, and a sensor measuring the oscillation frequency to determine the cavity losses.

47 OTHER INSTRUMENTATION↗

Transient Beam Loading Effects in Gas-filled RF Cavities for a Muon Collider

A gas-filled RF cavity can be an effective solution for the development of a compact muon ionization cooling channel. One possible problem expected in this type of cavity is the dissipation of significant RF power through the beam-induced plasmas accumulated inside the cavity (plasma loading). In addition, for the higher muon beam intensity, the effects of the beam itself on the cavity accelerating mode are non-negligible (beam loading). These beam- cavity interactions induce a transient phase which may be very harmful to the beam quality [1]. In this study, we estimate the transient voltage in a gas-filled RF cavity with both the plasma and conventional beam loading and discuss their compensation methods.

43 PARTICLE ACCELERATORS↗

Rebuild of Capture Cavity 1 at Fermilab

The front end of the proposed Advanced Superconducting Test Accelerator at Fermilab employs two single cavity cryomodules, known as 'Capture Cavity 1' and 'Capture Cavity 2', for the first stage of acceleration. Capture Cavity 1 was previously used as the accelerating structure for the A0 Photoinjector to a peak energy of ~14 MeV. In its new location a gradient of ~25 MV/m is required. This has necessitated a major rebuild of the cryomodule including replacement of the cavity with a higher gradient one. Retrofitting the cavity and making upgrades to the module required significant redesign. The design choices and their rationale, summary of the rebuild, and early test results are presented.

43 PARTICLE ACCELERATORS↗

RF kicker cavity to increase control in common transport lines

A method of controlling e-beam transport where electron bunches with different characteristics travel through the same beam pipe. An RF kicker cavity is added at the beginning of the common transport pipe or at various locations along the common transport path to achieve independent control of different bunch types. RF energy is applied by the kicker cavity kicks some portion of the electron bunches, separating the bunches in phase space to allow independent control via optics, or separating bunches into different beam pipes. The RF kicker cavity is operated at a specific frequency to enable kicking of different types of bunches in different directions. The phase of the cavity is set such that the selected type of bunch passes through the cavity when the RF field is at a node, leaving that type of bunch unaffected. Beam optics may be added downstream of the kicker cavity to cause a further separation in phase space.

43 PARTICLE ACCELERATORS↗

Conduction cooling systems for linear accelerator cavities

A conduction cooling system for linear accelerator cavities. The system conducts heat from the cavities to a refrigeration unit using at least one cavity cooler interconnected with a cooling connector. The cavity cooler and cooling connector are both made from solid material having a very high thermal conductivity of approximately 1.times.10.sup.4 W m.sup.-1 K.sup.-1 at temperatures of approximately 4 degrees K. This allows for very simple and effective conduction of waste heat from the linear accelerator cavities to the cavity cooler, along the cooling connector, and thence to the refrigeration unit.

42 ENGINEERING↗

Performance of Ferrite Vector Modulators in the LLRF System of the Fermilab HINS 6-Cavity Test

The High Intensity Neutrino Source (HINS) 6-cavity test is a part of the Fermilab HINS Linac R&D program for a low energy, high intensity proton Hsup>- linear accelerator. One of the objectives of the 6-cavity test is to demonstrate the use of high power RF Ferrite Vector Modulators(FVM) for independent control of multiple cavities driven by a single klystron. The beamline includes an RFQ and six cavities. The LLRF system provides a primary feedback loop around the RFQ and the distribution of the regulated klystron output is controlled by secondary learning feed-forward loops on the FVMs for each of the six cavities. The feed-forward loops provide pulse to pulse correction to the current waveform profiles of the FVM power supplies to compensate for beam-loading and other disturbances. The learning feed-forward loops are shown to successfully control the amplitude and phase settings for the cavities well within the 1 % and 1 degree requirements specified for the system.

79 ASTRONOMY AND ASTROPHYSICS↗

Cooling Dynamics Through Transition Temperature of Niobium SRF Cavities Captured by Temperature Mapping

Cool-down dynamics of superconducting accelerating cavities became particularly important for obtaining very high quality factors in SRF cavities. Previous studies proved that when cavity is cooled fast, the quality factor is higher than when cavity is cooled slowly. This has been discovered to derive from the fact that a fast cool-down allows better magnetic field expulsion during the superconducting transition. In this paper we describe the first experiment where the temperature all around the cavity was mapped during the cavity cool-down through transition temperature, proving the existence of two different transition dynamics: a sharp superconducting-normal conducting transition during fast cool-down which favors flux expulsion and nucleation phase transition during slow cool-down, which leads to full flux trapping.

43 PARTICLE ACCELERATORS↗

Assessment of Saturation Changes Around Cavities and the Impact on Seismic Waves.

According to theory, seismic methods should be able to identify cavities. The high impedance contrast between the rock (fast velocity, high density) and the air (slow velocity, low density) should produce strong reflections and refractions off cavity walls. In practice, however, cavities are not always easily detected. Changes in pore saturation, fracturing, and stress near the wall of the cavity may decrease the impedance contrast and diffuse the rock/air interface. To determine the impact of these effects on seismic waves, we first aim to understand the hydrological processes in the medium surrounding the cavity, a tunnel in this case. We simulate flow through the vadose zone to provide insight into how a cavity alters saturation. Next we examine how this saturation affects seismic velocities. Finally, we use a wave propagation code to simulate seismic waves through the saturation models. Results are presented from hydrology models for three cases: the tunnel far above the water table, the tunnel just above the water table and within the capillary fringe, and the tunnel below the water table with the tunnel being drained. We also present the results of seismic wave propagation through these models to determine the impact these effects have on seismic waves.

58 GEOSCIENCES↗

Progress on the Construction of the Perpendicularly Biased 2nd Harmonic Cavity for the Fermilab Booster

A perpendicularly biased tuneable 2nd harmonic cavity, designed for the Fermilab Booster, is being assembled for testing this summer (2018). The cavity will work at twice the frequency of the fundamental cavities, and will be on only during the injection and transition (or extraction) periods. The main reason for adding this cavity is to improve beam capture and reduce losses as required by Fermilab's Proton Improvement Plan (PIP). After three years optimization and study, the cavity design has now been finalized and all constituent parts have been received. We report on the cavity final design and on the status of the construction.

43 PARTICLE ACCELERATORS↗

Progress on the Construction of the Perpendicularly Biased 2nd Harmonic Cavity for the Fermilab Booster

A perpendicularly biased tuneable 2nd harmonic cavity, designed for the Fermilab Booster, is being assembled for testing this summer (2018). The cavity will work at twice the frequency of the fundamental cavities, and will be on only during the injection and transition (or extraction) periods. The main reason for adding this cavity is to improve beam capture and reduce losses as required by Fermilab's Proton Improvement Plan (PIP). After three years optimization and study, the cavity design has now been finalized and all constituent parts have been received. We report on the cavity final design and on the status of the construction

43 PARTICLE ACCELERATORS↗