Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building Energy Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

IEA EBC Annex 66: Definition and simulation of occupant behavior in buildings

Here, more than 30% of the total primary energy in the world is consumed in buildings. It is crucial to reduce building energy consumption in order to preserve energy resources and mitigate global climate change. Building performance simulations have been widely used for the estimation and optimization of building performance, providing reference values for the assessment of building energy consumption and the effects of energy-saving technologies. Among the various factors influencing building energy consumption, occupant behavior has drawn increasing attention. Occupant behavior includes occupant presence, movement, and interaction with building energy devices and systems. However, there are gaps in occupant behavior modeling as different energy modelers have employed varied data and tools to simulate occupant behavior, therefore producing different and incomparable results. Aiming to address these gaps, the International Energy Agency (IEA) Energy in Buildings and Community (EBC) Programme Annex 66 has established a scientific methodological framework for occupant behavior research, including data collection, behavior model representation, modeling and evaluation approaches, and the integration of behavior modeling tools with building performance simulation programs. Annex 66 also includes case studies and application guidelines to assist in building design, operation, and policymaking, using interdisciplinary approaches to reduce energy use in buildings and improve occupant comfort and productivity. This paper highlights the key research issues, methods, and outcomes pertaining to Annex 66, and offers perspectives on future research needs to integrate occupant behavior with the building life cycle.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of the DNAS framework expansion to occupant population synthesis

Research in occupant behaviour is now using a more elaborate framework of building occupant interaction. Researchers often face challenges in collecting data, particularly for the data to meet the minimum number of required data points and the data interoperability requirements. Researchers address the first issue with the synthetic population and the latter with data ontologies. While synthetic population is commonly used to address the first issue, data ontology development is used to address the latter. The two solutions are complementary to each other. One of the known ontologies in building occupant behaviour research is the Drivers-Needs-Actions-Systems (DNAS) ontology, which has been used by building modelers to describe energy-related occupant behaviour. This paper describes the ontology-based synthetic population generation that can be used in the agent-based modeling (ABM) applications. This paper considers multiple data sources, including ASHRAE Thermal Comfort DB II and IEA Annex 66 data sets. A case study of an office building is used to present the workflow of DNAS framework expansion, synthetic population generation, and agent-based modeling.

Chandra Putra, Handi↗

A Flexible and Generic Functional Mock-up Unit Based Threat Injection Framework for Grid-interactive Efficient Buildings: A Case Study in Modelica

Grid-interactive efficient buildings (GEBs) have been considered as an important asset to support the power grid reliability by utilizing the demand flexibility offered by GEBs. GEBs are enabled by advances in sensors and controls, and the communication between building equipment, whole buildings, and the grid. The integration of different building technologies and network-based communication system makes GEBs vulnerable to passive threats such as equipment failure and active threats such as cyber-attacks. Modeling and simulation is an effective way to evaluate the impact of threats on the system performance. This paper proposes a generic and flexible threat injection framework for commonly-used building energy simulators such as EnergyPlus and Modelica to support threat modeling and evaluation. This framework leverages functional mock-up unit (FMU) to develop a general modeling interface for threat injection and simulation. A numerical case study using Modelica as a building energy simulator is conducted to demonstrate the capability of the framework for supporting single/multiple-order threat modeling and simulation of a GEB. Four threats and their combinations are injected on a Modelica-based threat-free building energy and control system, including operating supply fan at its full speed, remotely cycling the chiller on and off, blocking the chiller from receiving the chilled water supply temperature setpoints, and hijacking the global zone air temperature setpoint. Simulation results show that the cyber-attack that leads to short-term signal blocking has small effects on the system operation due to the "self-healing" feature of the heating, ventilation, and air-conditioning (HVAC) interactive control system. The threat that takes control of resetting the global zone air temperature setpoints has the most adverse impact on the system energy use, peak power demand, thermal comfort and the provision of demand flexibility. The combination of four threats have aggregative effects on the system but the effects are less than the additive effects of the individual threat.

Fu, Yanyang↗

Analysis of Pre-Retrofit Building and Utility Data

IBACOS analyzed pre-retrofit daily utility data to sort homes by energy consumption, allowing for better targeting of homes for physical audits. Following ASHRAE Guideline 14 normalization procedures, electricity consumption of 1,166 all electric production-built homes' was modeled. The homes were in two communities -- one built in the 1970s and the other in the mid-2000s.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance evaluation of radiant cooling system integrated with air system under different operational strategies

The paper describes a parametric study developed to estimate the energy savings potential of a radiant cooling system installed in a commercial building in India. The study is based on numerical modeling of a radiant cooling system installed in an Information Technology (IT) office building sited in the composite climate of Hyderabad. To evaluate thermal performance and energy consumption, simulations were carried out using the ANSYS FLUENT and EnergyPlus softwares, respectively. The building model was calibrated using the measured data for the installed radiant system. Then this calibrated model was used to simulate the energy consumption of a building using a conventional all-air system to determine the proportional energy savings. For proper handling of the latent load, a dedicated outside air system (DOAS) was used as an alternative to Fan Coil Unit (FCU). A comparison of energy consumption calculated that the radiant system was 17.5 % more efficient than a conventional all-air system and that a 30% savings was achieved by using a DOAS system compared with a conventional system. Computational Fluid Dynamics (CFD) simulation was performed to evaluate indoor air quality and thermal comfort. It was found that a radiant system offers more uniform temperatures, as well as a better mean air temperature range, than a conventional system. To further enhance the energy savings in the radiant system, different operational strategies were analyzed based on thermal analysis using EnergyPlus. Lastly, the energy savings achieved in this parametric run were more than 10% compared with a conventional all-air system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hood River Passive House

The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

Final Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

In 2017, New York State Energy Research and Development Authority (NYSERDA) developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code. Since2017, NYSERDA has continued to develop the 2018 edition, as part of the efforts to achieve a statewide Net Zero Energy Code by 2028. To support this effort, Pacific Northwest National Laboratory (PNNL)conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code 2018 compared to ANSI/ASHRAE/IES1 Standard 90.1-2013. Specifically, PNNL collaborated with New Buildings Institute (NBI), and developed energy-efficiency measures (EEMs) from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the ongoing NYStretch-Energy code development process. PNNL analyzed these measures using whole building energy simulation for selected prototype commercial and multifamily buildings representing buildings in New York State.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Final Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

In 2017, New York State Energy Research and Development Authority (NYSERDA) developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code. Since 2017, NYSERDA has continued to develop the 2018 edition, as part of the efforts to achieve a statewide Net Zero Energy Code by 2028. To support this effort, Pacific Northwest National Laboratory (PNNL) conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code 2018 compared to ANSI/ASHRAE/IES1 Standard 90.1-2013. Specifically, PNNL collaborated with New Buildings Institute (NBI), and developed energy-efficiency measures (EEMs) from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the ongoing NYStretch-Energy code development process. PNNL analyzed these measures using whole building energy simulation for selected prototype commercial and multifamily buildings representing buildings in New York State. This report describes the analysis methodology, explains detailed specifications of the EEMs, and summarizes the results of individual EEMs and EEM bundles by building type and climate zone. As shown in Figure ES.1, significant energy saving could be achieved by adopting the NYStretch-Energy Code 2018.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dark energy or modified gravity? An effective field theory approach

We take an Effective Field Theory (EFT) approach to unifying existing proposals for the origin of cosmic acceleration and its connection to cosmological observations. Building on earlier work where EFT methods were used with observations to constrain the background evolution, we extend this program to the level of the EFT of the cosmological perturbations — following the example from the EFT of Inflation. Within this framework, we construct the general theory around an assumed background which will typically be chosen to mimic ΛCDM, and identify the parameters of interest for constraining dark energy and modified gravity models with observations. We discuss the similarities to the EFT of Inflation, but we also identify a number of subtleties including the relationship between the scalar perturbations and the Goldstone boson of the spontaneously broken time translations. We present formulae that relate the parameters of the fundamental Lagrangian to the speed of sound, anisotropic shear stress, effective Newtonian constant, and Caldwell's varpi parameter, emphasizing the connection to observations. It is anticipated that this framework will be of use in constraining individual models, as well as for placing model-independent constraints on dark energy and modified gravity model building.

79 ASTRONOMY AND ASTROPHYSICS↗

Data and Analytics to Inform Energy Retrofit of High Performance Buildings

Buildings consume more than one-third of the world?s primary energy. Reducing energy use in buildings with energy efficient technologies is feasible and also driven by energy policies such as energy benchmarking, disclosure, rating, and labeling in both the developed and developing countries. Current energy retrofits focus on the existing building stocks, especially older buildings, but the growing number of new high performance buildings built around the world raises a question that how these buildings perform and whether there are retrofit opportunities to further reduce their energy use. This is a new and unique problem for the building industry. Traditional energy audit or analysis methods are inadequate to look deep into the energy use of the high performance buildings. This study aims to tackle this problem with a new holistic approach powered by building performance data and analytics. First, three types of measured data are introduced, including the time series energy use, building systems operating conditions, and indoor and outdoor environmental parameters. An energy data model based on the ISO Standard 12655 is used to represent the energy use in buildings in a three-level hierarchy. Secondly, a suite of analytics were proposed to analyze energy use and to identify retrofit measures for high performance buildings. The data-driven analytics are based on monitored data at short time intervals, and cover three levels of analysis ? energy profiling, benchmarking and diagnostics. Thirdly, the analytics were applied to a high performance building in California to analyze its energy use and identify retrofit opportunities, including: (1) analyzing patterns of major energy end-use categories at various time scales, (2) benchmarking the whole building total energy use as well as major end-uses against its peers, (3) benchmarking the power usage effectiveness for the data center, which is the largest electricity consumer in this building, and (4) diagnosing HVAC equipment using detailed time-series operating data. Finally, a few energy efficiency measures were identified for retrofit, and their energy savings were estimated to be 20percent of the whole-building electricity consumption. Based on the analyses, the building manager took a few steps to improve the operation of fans, chillers, and data centers, which will lead to actual energy savings. This study demonstrated that there are energy retrofit opportunities for high performance buildings and detailed measured building performance data and analytics can help identify and estimate energy savings and to inform the decision making during the retrofit process. Challenges of data collection and analytics were also discussed to shape best practice of retrofitting high performance buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy and IAQ Implications of Residential Ventilation Cooling

This study evaluates the energy, humidity and indoor air quality (IAQ) implications of residential ventilation cooling in all U.S. IECC climate zones. A computer modeling approach was adopted, using an advanced residential building simulation tool with airflow, energy and humidity models. An economizer (large supply fan) was simulated to provide ventilation cooling while outdoor air temperatures were lower than indoor air temperatures (typically at night). The simulations were performed for a full year using one-minute time steps to allow for scheduling of ventilation systems and to account for interactions between ventilation and heating/cooling systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hood River Passive House, Hood River, Oregon (Fact Sheet)

The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50%" (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupant behavior models: A critical review of implementation and representation approaches in building performance simulation programs

Occupant behavior (OB) in buildings is a leading factor influencing energy use in buildings. Quantifying this influence requires the integration of OB models with building performance simulation (BPS). This study reviews approaches to representing and implementing OB models in today’s popular BPS programs, and discusses weaknesses and strengths of these approaches and key issues in integrating of OB models with BPS programs. Two of the key findings are: (1) a common data model is needed to standardize the representation of OB models, enabling their flexibility and exchange among BPS programs and user applications; the data model can be implemented using a standard syntax (e.g., in the form of XML schema), and (2) a modular software implementation of OB models, such as functional mock-up units for co-simulation, adopting the common data model, has advantages in providing a robust and interoperable integration with multiple BPS programs. Such common OB model representation and implementation approaches help standardize the input structures of OB models, enable collaborative development of a shared library of OB models, and allow for rapid and widespread integration of OB models with BPS programs to improve the simulation of occupant behavior and quantification of their impact on building performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hood River Passive House

The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗

Hamilton: Flexible, Open Source $10 Wireless Sensor System for Energy Efficient Building Operation

Sensors for improving building performance are rapidly populating the market, driven in part by the drive to reduce greenhouse gas emissions resulting from energy production as well as improve the interior environment for healthy and more productive spaces. UC Berkeley has led wireless sensor development over the past 25 years (e.g., Telos mote), with the Hamilton (named after Alexander Hamilton on the US $10 bill) as the most recent. The Hamilton sensor was designed as a low-cost high-performance sensor that is modular and interoperable. The objective of the Hamilton project was to create, evaluate and establish the technological foundations for secure and easy to deploy building energy efficiency applications utilizing pervasive, low-cost wireless sensors integrated with traditional Building Management Systems (BMS), consumer-sector building components, and powerful data analytics. The project included iterative hardware design, incorporating a high-performance database (BTrDb, http://btrdb.io/), creating and iterating the development of secure data middleware (BOSSwave, WAVE/WAVEMQ), working with and pushing the development of an open-source tiny operating system RiotOS, and implementing and improving protocols such as Thread/OpenThread and TCP/IP. The hardware benefited from careful design to drive down the cost; the design included a System-on-a-Chip (SoC), chip antenna, single crystal and five passive components. Careful design of the operating system created a low-power design to enable a long life with small batteries. The hardware included several sensors: temperature, radiant temperature, relative humidity, magnetometer, accelerometer, and light, with an optional occupancy (Passive InfraRed) sensor. The project was the basis of several applications, both internal to the research team and other researchers and professionals at other institutions. Several applications used the sensor hardware as the basis for other complex devices. Other applications used the sensors to improve building performance through interoperating with the building Heating Ventilation and Air-Conditioning (HVAC) system, such as using occupancy and/or distributed temperature sensing to reduce HVAC zone energy while still providing thermal comfort and to reduce peak loads in small commercial buildings. We demonstrated cloud-based energy analytics, implemented a schedule and a Model Predictive Controller in a small commercial building to optimize HVAC energy, occupancy and electricity price. Initial integration of these technological innovations was performed through the creation of execution containers containing the WAVE agent and various driver, proxy, or building system function logic. The research added to the understanding of efficient sensor hardware, secure middleware, time-series data management (high performance database), efficient communication protocols, and interoperating with applications and building systems. The project showed the technical effectiveness and economic feasibility of creating a low-cost, modular, and easy-to-deploy sensor. Through conversations with multiple end users, the research team discovered that many customers wanted data management and services in addition to the sensors. HamiltonIOT developed packages of sensors, border router, and data services to provide a seamless “plug-and-play” sensor deployment. Some customers were willing to pay for higher quality sensors (such as light); some customers wanted a robust enclosure (waterproof).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗