Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Balloon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Constraints on the Optical Depth to Reionization from Balloon-borne Cosmic Microwave Background Measurements

We assess the uncertainty with which a balloon-borne experiment, nominally called Tau Surveyor (τS), can measure the optical depth to reionization σ(τ) with given realistic constraints of instrument noise and foreground emissions. Using a τS fiducial design with six frequency bands between 150 and 380 GHz, with white and uniform map noise of 7 μK arcmin, achievable with a single midlatitude flight, and including Planck's 30 and 44 GHz data, we assess the error σ(τ) obtained with three foreground models and as a function of sky fraction f sky between 40% and 54%. We carry out the analysis using both parametric and blind foreground separation techniques. We compare the σ(τ) values to those obtained with low-frequency and high-frequency versions of the experiment called τS-lf and τS-hf, which have only four and up to eight frequency bands with narrower and wider frequency coverage, respectively. We find that with τS, the lowest constraint is σ(τ) = 0.0034, obtained for one of the foreground models with f sky = 54%. σ(τ) is larger, in some cases by more than a factor of 2, for smaller sky fractions, with τS-lf, or as a function of foreground model. The τS-hf configuration does not lead to significantly tighter constraints. The exclusion of the 30 and 44 GHz data, which give information about synchrotron emission, leads to significant τ misestimates. Decreasing noise by an ambitious factor of 10, while keeping f sky = 40%, gives σ(τ) = 0.0031. The combination of σ(τ) = 0.0034, baryon acoustic oscillation data from DESI, and future cosmic microwave background B-mode lensing data from the CMB-S3/CMB-S4 experiments could give σ(∑m v ) = 17 meV.

cosmic microwave background radiation↗

How to Fly with BPO & Requirements & Recommendations for Balloon Gondola Design

An overview of the launch process from initial solicitation through flight. The discussion will include the overall review process for balloon missions seeking flights from all launch locations, high level overview of required documentation, and specific requests for safety review. Also a presentation on the Gondola Structural Design Handbook with recommendations.

Balloon↗

2024 NASA Balloon Program Overview

Enable discovery through conduct of frequent scientific balloon flight opportunities for NASA scientific, technology development, and educational investigations.

Balloon↗

NASA Balloon Program

The NASA Balloon Program provides low-cost, quick response, near space access to NASA’s Science Community for conducting cutting edge science investigations.

Balloon↗

ARM-Related Unmanned Aerial System (UAS) and Tethered Balloon System (TBS) Operational Requirements and Approval

This procedure addresses the requirements and process for obtaining approval for Unmanned Aerial System (UAS) and Tethered Balloon System (TBS) operations at DOE Office of Science (SC) Atmospheric Radiation Measurement user facility observatories (ARM sites), ARM-supported training flights, atmospheric instrument development flights, and campaigns at non-ARM sites. ARM sites include both ARM observatories and ARM mobile facility deployments. The protection of people, property, and the environment during UAS and TBS operations is the foundation of executing a successful mission using UAS or TBS. This procedure is designed to facilitate safe mission execution. It does not address obtaining approval for ARM-supported research, which is approved through the ARM Field Campaign (AFC) or Engineering Evaluation (EE) processes. Approval of UAS and TBS operations is a prerequisite for final approval of an AFC or EE by the Infrastructure Management Board (IMB) and may be conducted in parallel with preparation and submittal of the AFC or EE proposal to the IMB. This procedure addresses UAS and TBS requirements; mission planning; documentation; maintenance; risk assessment; airworthiness determination; operation approval; training and qualification requirements and responsibilities for UAS remote pilots; TBS operators; visual observers; maintenance technicians; and A&P mechanics. It also addresses the responsibilities of ARM site managers, the Office of Science Aviation Safety Manager, principal investigators, requesting organizations, and Range Safety Officers. This procedure is derived from DOE O 440.2C, Aviation Management and Safety, and Federal Aviation Administration (FAA) Regulations (FARs), 14 CFR 107, and 14 CFR 101. It contains two sections: Section 3.0 addresses UAS operations; Section 4.0 addresses TBS operations.

unmanned aerial systems, tethered balloon systems,↗

Restenosis After Balloon Angioplasty for Cerebral Vasospasm

Transluminal balloon dilatation for symptomatic vasospasm after subarachnoid hemorrhage is effective, and clinical studies have shown that it achieves long-lasting dilatation of spastic cerebral arteries. Delayed arterial renarrowing has not been reported. Here we report the case of a 58-year-old woman who presented asymptomatic and permanent restenosis after angioplasty for cerebral vasospasm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Restoration of Failed Renal Graft Function After Successful Angioplasty of Pressure-Resistant Renal Artery Stenosis Using a Cutting Balloon: A Case Report

This study is the report of a 37-year-old male with a transplanted kidney from a 3.5-year-old donor: the graft had two arteries transplanted with an aortic patch to an external iliac artery. Four months after transplantation, the graft function deteriorated, together with the development of hypertension. Stenosis of both graft arteries was detected and the patient was referred for angioplasty. The angiographic result was suboptimal, nevertheless, the graft function improved and was more or less stable (serum creatinine, 160-200 {mu}mol/l) for 4 years, along with persistently difficult-to-control hypertension. Five years after transplantation, the graft function deteriorated again and severe graft artery restenosis was detected. The restenosis did not respond to dilatation, graft function failed, hypertension decompensated, and left ventricular failure developed. The patient required dialysis. A cutting balloon angioplasty opened the artery, and kidney function was restored after a few days: the serum creatinine level dropped to 140-160 {mu}mol/l, and the glomerular filtration rate (creatinine clearance) to 0.65 ml/min/1.73 m{sup 2}. The graft function has now been stable for more than 2 years, however, the hypertension is still difficult to control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Posttransplant Complex Inferior Venacava Balloon Dilatation After Hepatic Vein Stenting

Orthotopic and living related liver transplantation is an established mode of treatment of end-stage liver disease. One of the major causes of postoperative complications is vascular anastomotic stenosis. One such set of such complications relates to hepatic vein, inferior vena cava (IVC), or portal vein stenosis, with a reported incidence of 1-3%. The incidence of vascular complications is reported to be higher in living donor versus cadaveric liver transplants. We encountered a patient with hepatic venous outflow tract obstruction, where the hepatic vein had been previously stented, but the patient continued to have symptoms due to additional IVC obstruction. The patient required double-balloon dilatation of the IVC simultaneously from the internal jugular vein and IVC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vertebral Arteriovenous Fistula Presenting as Cervical Myelopathy: A Rapid Recovery with Balloon Embolization

A 24-year-old male presented with progressive cervical myelopathy of 2 months' duration. Magnetic resonance imaging of the cervical spine and angiography revealed a large arteriovenous fistula arising from the left vertebral artery. The present case highlights the clinical features and dramatic recovery following endovascular balloon occlusion of a giant cervical arteriovenous fistula.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Septic Complication After Balloon-Occluded Retrograde Transvenous Obliteration of Duodenal Variceal Bleeding

We report a 64-year-old woman with duodenal varices who underwent balloon-occluded retrograde transvenous obliteration (B-RTO) complicated by intraprocedural variceal rupture. The patient developed shivering and a fever higher than 40{sup o}C 3 days after the B-RTO procedure. A blood culture grew Entereobacter cloacoe. This case represents a rare septic complication of B-RTO for duodenal varices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Balloon-Occluded Retrograde Transvenous Obliteration of Gastric Varix Via the Pericardiacophrenic Vein

We encountered a case of gastric varix without a gastrorenal shunt that drained through the left pericardiacophrenic vein, which entered the left brachiocephalic vein. For this case we successfully performed balloon-occluded retrograde transvenous obliteration, in which sclerotic agents were infused via the left pericardiacophrenic vein approached from the left subclavian vein.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Experience with Computed Tomography and Fluoroscopically Guided Placement of Push-Type Gastrostomy Tubes Using a Rupture-Free Balloon Catheter

The purpose of this study was to evaluate the safety and feasibility of percutaneous radiologic gastrostomy placement of push-type gastrostomy tubes using a rupture-free balloon (RFB) catheter under computed tomography (CT) and fluoroscopic guidance. A total of 35 patients (23 men and 12 women; age range 57-93 years [mean 71.7]) underwent percutaneous CT and fluoroscopically guided gastrostomy placement of a push-type gastrostomy tube using an RFB catheter between April 2005 and July 2008. Technical success, procedure duration, and complications were analyzed. Percutaneous radiologic gastrostomy placement was considered technically successful in all patients. The median procedure time was 39 {+-} 13 (SD) min (range 24-78). The average follow-up time interval was 103 days (range 7-812). No major complications related to the procedure were encountered. No tubes failed because of blockage, and neither tube dislodgement nor intraperitoneal leakage occurred during the follow-up period. The investigators conclude that percutaneous CT and fluoroscopically guided gastrostomy placement with push-type tubes using an RFB catheter is a safe and effective means of gastric feeding when performed by radiologists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transhepatic Venous Approach for Balloon-assisted Cervical Collateral Venous Access

Central venous catheter placement is indicated in many situations, and an increasing number of patients require temporary and long-term central catheters. Frequently, patients who have undergone multiple central veins catheterizations develop complete and diffuse venous occlusion, and this constitutes a difficult-to-manage clinical problem. We report a case of a 20-year-old patient who was referred to our department for central venous line placement who manifested bilateral femoral, jugular, and subclavian veins occlusion. A central venous catheter was implanted through a cervical collateral vein, targeting on and puncturing an angioplasty balloon, and advanced into the collateral vein through a transhepatic venous access.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interlocking Detachable Coil Embolization by Technique of Dumbbell-Shaped Framing and Filling and Bridge Formation Under Balloon Dilatation for Huge Conglomerate Pulmonary Arteriovenous Malformation

A 60-year-old woman presented with a conglomerate pulmonary arteriovenous malformation (PAVM) size 8.2 Multiplication-Sign 7.2 cm on chest X-ray. Feeding arteries were A{sub a}{sup 7} and A{sub b}{sup 7}, A{sup 8}, and A{sup 10}. The diameter and length of the A{sub b}{sup 7} neck were 15.5 and 16 mm, respectively. After percutaneous transcatheter embolization of A{sup 8} and A{sup 10}, PTE of A{sub a}{sup 7} and A{sub b}{sup 7} was conducted under balloon occlusion with interlocking detachable coils using a technique of dumbbell-shaped framing and filling, making a bridge from A{sub b}{sup 7} to the trunk of A{sup 9} and A{sup 10}across A{sup 7}. Follow-up computed tomography 10 months after treatment showed marked shrinkage of the PAVM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗