Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BYPASSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

NASA’s Efficient Quiet Integrated Propulsors (Equip) Technical Challenge

Advances in aircraft propulsor technology - ducted and unducted - are key elements to developing a sustainable aviation future. Increasing propulsive efficiency comes with significant challenges. The long-term trend in aircraft engine design has been towards higher bypass ratios to increase efficiency and decrease noise. Current designs are pushing against limits on engine size; the engine must fit under the wing and overcome the nacelle weight, aerodynamic drag, and airframe integration penalties associated with an ultra-high bypass ratio. The next-generation ducted engines will have shorter inlets and smaller rotor-stator spacing to minimize nacelle area. This increases the potential for non-uniform flow at the fan face and less area for acoustic liners. Unducted engines eliminate the nacelle penalty while presenting challenges to noise and operability in distorted flow environments. The overall diameter in both cases raises questions about engine-airframe integration to maximize efficiency gains and minimize installation penalties. The National Aeronautics and Space Administration (NASA) Advanced Air Vehicles Program (AAVP) approved the Efficient Quiet Integrated Propulsor (EQuIP) Technical Challenge (TC) under the Advanced Air Transport Technology (AATT) Project to work on next-generation propulsor technologies in collaboration with NASA’s government and industry partners in the Sustainable Flight National Partnership. The EQuIP TC leverages NASA resources with Federal Aviation Administration (FAA) and industry investments under the FAA’s Continuous Lower Energy Emissions and Noise (CLEEN) program to address technical challenges on the propulsor subject to the flow field imposed by the engine-airframe-flight environment. The EQuIP TC complements NASA Aeronautics Research Mission Directorate’s (ARMD) existing investments in sustainable aviation for the next-generation of commercial aircraft and contributes to meeting the noise and efficiency goals set by the Sustainable Flight National Partnership and U.S. Aviation Climate Action Plan. This paper introduces the EQuIP TC, describes key parts of its development, and presents the background research used to scope its impact.

Propulsion↗

Numerical and Experimental Studies of Ultra Low Profile Three-dimensional Heat Sinks (3DHS) Made using a Novel Manufacturing Approach

The continued increase in electronic device packaging densities is placing ever more challenging performance requirements on air-cooled heat sinks. In cases where the state-of-the-art heat sink technology is unable of to meet these requirements, this often results in either a relaxation of design specifications, or the exploration of other thermal management technologies better able to handle high heat density applications, such as liquid cooling. Both of these approaches provide challenges to equipment designers, as relaxing requirements does not allow for a scale-able path to increased device densities and their associated functionality, while incorporating new thermal management technologies often requires major hardware redesigns, which has significant cost implications. In this work, we explore the use of air-cooled heat sinks incorporating three-dimensional features, so-called three-dimensional heat sinks (3DHS), that enhance heat transfer through a number of different physical mechanisms, as an approach to further extending the limits of air cooling. An ultra low profile (5.7 mm) heat sink application is targeted due to the significant thermal challenges associated with restrictions on heat sink height. We also present details on a novel manufacturing method that has significant cost advantages over other fabrication methods such as investment casting and direct metal printing. Experiments on 3DHS and conventional heat sink are conducted in a wind tunnel test apparatus as a function of inlet air mass flow rate and flow bypass above the heat sinks. The experimental results show a strong correlation between heat sink permeability and thermal performance, as measured by heat sink thermal resistance versus ideal pumping power. The results also illustrate the important effects of flow bypass on heat sink performance. The best performing 3DHS design is observed to have up to a 19% improvement in thermal performance relative to a conventional parallel fin heat sink of the same form factor. Comparison of the experimental results with finite-volume simulations of the laminar, steady equations for mass, momentum and energy transport shows good agreement for heat sink thermal resistance and pressure drop across the heat sink. For the case where the fluid flow is modeled as transitional and steady, there is a greater discrepancy between simulations and experiments, suggesting that the experimental flow conditions are predominantly laminar.

42 ENGINEERING↗

SeaStar Unchained: Multiplying the Performance of the Cray SeaStar Network

The Oak Ridge Leadership Computing Facility (OLCF) supports many different systems and many differ- ent interconnects. The only common programming interfaces across these systems are BSD Sockets and MPI. Due to the design assumptions such as implicit buffering leading to extra copies, Sockets performance is almost universally lower than the native interface. Even in the cases that Sockets provides similar bandwidth as the native interface, it suffers from excessive CPU usage. MPI is the de-facto interface for intra- job communication, but is difficult to use between jobs and provides no ability to communicate with service nodes or off- system nodes (e.g. for I/O forwarding). We have developed the Common Communication Interface (CCI), a programming interface that exposes the advances in interconnect hardware, notably Remote Direct Memory Access (RDMA) and operating system (OS) bypass, while imposing as little overhead as possible. This API directly supports inter-job as well as off- system communication. CCI is a lightweight abstraction layer that provides point-to-point messaging and remote memory access. The Cray SeaStar ASIC, with its programmable embedded processor, provides an excellent platform to investigate the properties of various network protocols and programming interfaces. This paper describes our native implementation CCI on the SeaStar platform, and details how we implemented full OS bypass for common operations. We demonstrate a 30% to 50% reduction in latency, more than a six-fold increase in message injection rate, and an almost 7x improvement in bandwidth for small message sizes when compared to the generic Cray Portals implementation.

Dillow, David A↗

Combustion mode switching with a turbocharged/supercharged engine

A method for switching between low- and high-dilution combustion modes in an internal combustion engine having an intake passage with an exhaust-driven turbocharger, a crankshaft-driven positive displacement supercharger downstream of the turbocharger and having variable boost controllable with a supercharger bypass valve, and a throttle valve downstream of the supercharger. The current combustion mode and mass air flow are determined. A switch to the target combustion mode is commanded when an operating condition falls within a range of predetermined operating conditions. A target mass air flow to achieve a target air-fuel ratio corresponding to the current operating condition and the target combustion mode is determined. The degree of opening of the supercharger bypass valve and the throttle valve are controlled to achieve the target mass air flow. The amount of residual exhaust gas is manipulated.

33 ADVANCED PROPULSION SYSTEMS↗

System and method for regulating EGR cooling using a rankine cycle

This disclosure relates to a waste heat recovery (WHR) system and method for regulating exhaust gas recirculation (EGR) cooling, and more particularly, to a Rankine cycle WHR system and method, including a recuperator bypass arrangement to regulate EGR exhaust gas cooling for engine efficiency improvement and thermal management. This disclosure describes other unique bypass arrangements for increased flexibility in the ability to regulate EGR exhaust gas cooling.

42 ENGINEERING↗

System and method for regulating EGR cooling using a Rankine cycle

This disclosure relates to a waste heat recovery (WHR) system and method for regulating exhaust gas recirculation (EGR) cooling, and more particularly, to a Rankine cycle WHR system and method, including a recuperator bypass arrangement to regulate EGR exhaust gas cooling for engine efficiency improvement and thermal management. This disclosure describes other unique bypass arrangements for increased flexibility in the ability to regulate EGR exhaust gas cooling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methods for immortalization of epithelial cells

Methods for inducing non-clonal immortalization of normal epithelial cells by directly targeting the two main senescence barriers encountered by cultured epithelial cells. In finite lifespan pre-stasis human mammary epithelial cells (HMEC), the stress-associated stasis barrier was bypassed, and in post-stasis HMEC, the replicative senescence barrier, a consequence of critically shortened telomeres, was bypassed. Early passage non-clonal immortalized lines exhibited normal karyotypes. Methods of efficient HMEC immortalization, in the absence of “passenger” genomic errors, should facilitate examination of telomerase regulation and immortalization during human carcinoma progression, methods for screening for toxic and environmental effect on progression, and the development of therapeutics targeting the process of immortalization.

59 BASIC BIOLOGICAL SCIENCES↗

Additive Manufacturing of Frequency-Agile W-Band Packaging

Abstract —In this paper we demonstrate a fully additively manufactured packaged W-band amplifier with integrated bypass capacitors. This package was fabricated using a chip-first approach and aerosol jet printing. Package substrates (dielectrics), conductors and interconnects are printed around a bare die attached to a carrier. This package uses shaped ramp interconnects, allowing for frequency agnostic package performance of the interconnect with no impedance discontinuity, within the physical limits of the printer. High dielectric constant thin films of a polymer-matrix nanocomposite for bypass capacitors were printed using multi-material aerosol jet printing. The maximum measured packaged gain is 14.9 dB in the W-band, compared to the maximum bare die gain of 15.5 dB in the same frequency range. From 75 - 92 GHz, the average package loss is 1.1 dB including 3 mm transmission line, interconnects, and a GSG launch structure correlating to an average loss of 0.37 dB/mm.

Additive manufacturing, aerosol jet printing, hete↗

Diverter fittings for cooling systems of an engine

A passive diverter fitting for a cooling system of an engine includes a base defining an interior cavity, an inlet opening extending through the base that is in fluid communication with the interior cavity, an outlet opening that is in fluid communication with the interior cavity, and a bypass opening that is in fluid communication with the interior cavity. The base is configured to be removably disposed in a cavity of an engine block. The inlet opening is positioned to receive coolant when the passive diverter fitting is disposed in the cavity of the engine block. The outlet opening is in fluid communication with the area exterior to the engine block when the passive diverter fitting is disposed in the cavity of the engine block. The bypass opening is in fluid communication with an interior coolant passage of the engine block when the passive diverter fitting is disposed in the cavity of the engine block.

Chen, Allen Yao↗

Modeling prismatic HTGRs with U.S. N.R.C advanced gas reactor evaluator (AGREE)

A core fluids and heat transfer model has been developed for the prismatic high temperature gas reactor in support of the US NRC Next Generation Nuclear Plant (NGNP) evaluation model. The core fluids modeling relies on a subchannel approach in which the primary coolant flow path through the core region and vertical in-core and ex-core gaps can be modeled as individual subchannels. These subchannels are connected together to represent a three dimensional reactor. An initial validation calculation for the core fluids model has been performed using data available in literature for bypass flow. The predicted bypass flow was within 2.6% of the value reported in the literature. The core level heat transfer model is based on a triangular finite volume method, where the base triangle is one sixth of the prismatic block. In order to improve the spatial accuracy at this level, a triangular refinement method was also implemented. The fuel compact temperature is calculated by a cylindrical conduction model which is implicitly coupled to the triangular core level model. The preliminary verification of the model was performed by comparing AGREE to a finite element code COMSOL by analyzing the MHTGR core heat transfer. Further verification and validation is currently an ongoing effort. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of flow network analysis code for block type VHTR core by linear theory method

VHTR (Very High Temperature Reactor) is high-efficiency nuclear reactor which is capable of generating hydrogen with high temperature of coolant. PMR (Prismatic Modular Reactor) type reactor consists of hexagonal prismatic fuel blocks and reflector blocks. The flow paths in the prismatic VHTR core consist of coolant holes, bypass gaps and cross gaps. Complicated flow paths are formed in the core since the coolant holes and bypass gap are connected by the cross gap. Distributed coolant was mixed in the core through the cross gap so that the flow characteristics could not be modeled as a simple parallel pipe system. It requires lot of effort and takes very long time to analyze the core flow with CFD analysis. Hence, it is important to develop the code for VHTR core flow which can predict the core flow distribution fast and accurate. In this study, steady state flow network analysis code is developed using flow network algorithm. Developed flow network analysis code was named as FLASH code and it was validated with the experimental data and CFD simulation results. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal hydraulic method for whole core design analysis of an HTGR

A new thermal hydraulic method and initial results are presented for core-wide steady state analysis of prismatic High Temperature Gas-Cooled Reactors (HTGR). The method allows for the complete solution of temperature and coolant mass flow distribution by solving quasi-steady energy balances for the discretized core. Assembly blocks are discretized into unit cells for which the average temperature of each unit cell is determined. Convective heat removal is coupled to the unit cell energy balances by a 1-D axial flow model. The flow model uses established correlations for friction factor and Nusselt number. Bypass flow is explicitly calculated by using an initial guess for mass flow distribution and determining the exit pressure of each flow channel. The mass flow distribution is updated until a uniform core exit pressure condition is reached. Results are obtained for the MHTGR-350 with emphasis on the change in thermal hydraulic parameters due to various steady state power profiles and bypass gap widths. Steady state temperature distribution and its variations are discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Lessons Learned from Most Recent Chemical Decontamination for Decommissioning Projects - 19280

In 2017, Westinghouse performed a full system chemical decontamination of Units 1 and 2 of the Bohunice V1 Nuclear Power Plant. Bohunice V1 is a VVER 440 design with six loops. The application was performed two loops at a time, with the reactor core bypassed. The Pressurizer and Pressurizer Relief Tank (Bubble Tank) were decontaminated as well, in a separate application. This was a recovery decontamination that had been attempted by another company prior to Westinghouse. Several modifications to equipment and design of process were required to make the decontamination successful. The project was initiated to perform pre-dismantling chemical decontamination of primary circuits of both V1 units using Decontamination for Decommissioning (DfD) to meet the following objectives (see References 1 and 2 for process descriptions of DfD): - Remove activity from the primary circuit components; - Reduce dose rates around piping and components; - Simplify access to the installations, making it possible to use hands-on techniques for dismantling, rather than the more expensive use of robotics or manipulators; - Minimize the potential for spreading contamination during decommissioning activities - Reduce the activity of components that they may be disposed of at a lower classification, therefore more economical, waste disposal category. Several techniques were employed that were unique, or first of a kind, to aid in the decontamination, including resin regeneration and bypass of the reactor core, while still providing enough flow to to allow sufficient dispersal through all the steam generator tubes. Equipment that was already available on site was evaluated and, when possible, combined with Westinghouse equipment to minimize application cost and schedule. The lessons learned from the first unit (Unit 2) were applied to the second unit (Unit 1) application. The partial relocation of equipment allowed for the most efficient schedule to complete the second decontamination. The paper will describe in more detail the results and lessons learned from the full system chemical decontaminations performed, as well as updates on another recent decontamination project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Aging and Demand for Reliability Analysis of Degrading Components

According to the U.S Energy Information Administration (EIA), the U.S fossil fuel share of energy consumption in 2015 was 67%. Furthermore, the Ecotricity UK report based on the CIA World Factbook states that with the current rate of consumption of fossil fuels, petroleum would run out by 2052, natural gas by 2060, and coal by 2088. No fossil fuel will remain by the next century. Besides the limited reserves of fossil fuel, massive consumption of fossil fuel also raises concerns about global warming and pollution. Therefore, there has been a growing interest in reducing fossil fuel consumption in the energy structure and in increasing the proportion of clean energy. Renewable energy (e.g. wind, solar) has the potential for distributed generation. However, the availability for renewable energy fluctuates and is uncontrollable. Therefore, additional energy sources need to be coupled with renewable energy to produce a stable electricity generation profile. Nuclear energy can serve this purpose as it is a clean energy source, has low greenhouse gas emission and possesses high power density and baseload power supply with low fuel cost. It is desirable to develop a hybrid energy system that combines both renewable energy and nuclear energy to meet low carbon emission goals and to utilize renewable energy. Such a nuclear hybrid energy system, consisting of different energy subsystems such as nuclear, solar, and wind, involves frequent switching between different energy subsystems. Since the primary loop in a nuclear power plant generates constant heat, the turbine bypass line in the secondary loop is required to switch frequently to meet the gap in the energy demand and that generated by the renewables. The increased usage of the turbine bypass system is considered to be the major difference between a nuclear hybrid energy system and a traditional nuclear power plant. Reliability analysis for designing such a complex system involves both high level fault propagation analysis at the conceptual design stage and low level failure prediction for specific components. The main focus of this summary to derive a degradation model of hardware components which can later help in the high level fault propagation analysis. The degradation model is a low level failure mode model that combines the effects of natural aging and frequent switching. The model can be used for predicting components' failure due to specific failure modes. The results can serve as indicators for conducting repair actions and maintenance to minimize Operation and Maintenance (O and M) costs. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Operator Action Time Evaluation of Emergency Water Injection Strategy for Extreme SGTR Accidents

In terms of severe accidents caused by earthquakes or tsunamis that are beyond expectation, a special safety inspection for operating plants, following the Fukushima accident, has been conducted by the government of Korea to verify that nation's nuclear power plants have been adequately designed to respond to extreme accidents. The inspection results show that Korean nuclear power plants in operation have no imminent risk for an expected maximum potential earthquake or coastal flooding based on the up-to-date investigation. However, there is a need to implement long- and short-term safety improvements in order to secure the level of safety for natural beyond-design-basis events. One of the measures to increase the mitigation capability during extreme accidents is installing the injection flow paths to provide emergency cooling water of extemal sources using fire engines to the steam generators (SGs) or reactor cooling system (RCS). An emergency cooling water system consists of a fixed pipe connected from the RCS or SGs to the outside of the containment. A standby valve is installed on the pipe. Following the occurrence of an extreme accident, movable equipment (for example, a fire truck hose) can be connected to the pipe hole at the opening of the isolation valve. The emergency cooling water injection strategy was not taken into account for the steam generator tube rupture (SGTR) accident management strategy of the OPR-1000. Therefore, it is necessary to develop some guidelines or strategies to cope with an extreme SGTR scenarios using the newly installed injection flow paths and fire engines. As long as the fission products released from the core during severe accidents are kept inside the containment, there may be several ways to reduce the radionuclide release into the environment, for example, by using plant safety features. The containment bypass sequences, however, allow the fission products to be released into the environment or directly to the auxiliary building. The SGTR accidents, which are one of the containment bypass sequences, have shown during various probabilistic safety assessments (PSAs) to be contributors to plant risk, mainly because of their potential for causing a release outside containment. This paper is intended to be an investigation of the characteristics of accident progressions and assessments for the mitigative effectiveness of the external cooling water injection strategies during extreme SGTR accidents in a typical OPR-1000 plant. Analyses were performed using a MAAP computer code version 5.03. The MAAP code is a system-level computer code capable of conducting integral analyses of potential severe accident progressions in nuclear power plants, whose main purpose is to support a level 2 PSA or severe accident management strategy developments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling Advanced Strippers for CO2 Capture from Gas-Fired Power Plants using Aqueous Piperazine

Energy performance of 5 m piperazine was evaluated with an advanced stripper at the pilot scale, accounting for heat loss. Modeling studies indicated that heat loss at locations other than the heat source impacted the heat duty. For strippers with excess packing, the column was the most important source of heat loss, and values as low as 0.03 GJ/hr can cause pinch and reabsorption of CO2. Solvents like 5 m PZ are more affected by heat loss in the column due to a top-side temperature pinch at high lean loading. Heat loss impacts NGCC CO2 capture more than coal-based CO2 capture. Surface temperature measurements pilot plants showed that heat loss was 50-75% controlled by natural convection. Measured heat loss was correlated with steam flowrate and wind speed and ranged from 8126 to 219668 Btu/hr, representing 35% of the measured heat rate on average. Net heat duty linearly varied with CO2 removal at low lean loading and was similar for coal and NGCC conditions at fixed removal. At 90% removal, net heat duty was about 2.5 GJ/t with 4 and 12% CO2 in the flue gas. 7 At NGCC conditions, strippers with finite packing can benefit from a flashing feed to the top of the column by using a hot bypass. A flashing feed was linked to a reduction in irreversibility of the stripper from temperature driving forces. It also reduces heat duty by up to 6% at fixed packing height and reduces packing requirement for a fixed steam heater size compared to a warm bypass. Lean loading and lean solvent rate were effective handles to maximize profitability of a fixed stripper design at low gas price. High ambient temperature operation can benefit from low pressure stripping to about 0.18 lean loading at 150 ℃ to maintain the cyclic capacity at reduced rich loading. At low gas price, the capture plant was able to maximize profitability even with a high heat duty of 2.7-3.1 GJ/t at a lean loading of 0.2-0.22 mol/mol. Heat recovery by partial water vapor condensation in a gas-liquid exchanger can be replaced by a direct contact condenser (DCC). The DCC improved gas cooling and reduced heat duty compared to the CO2 exchanger at 0.2 lean loading. The DCC when used with a 150 ℃/5.5 bar stripper can reduce the cost of capture compared to the base case by $3- 4/tonne at 15 ft of packing (optimum) but increases cost of capture by $6/tonne with a 120 ℃/2 bar stripper and 10 ft of packing (optimum). The DCC can work effectively with a solvent with a high heat of absorption and thermal stability.

Suresh Babu, Athreya↗

Phase change based cooling for high burst mode heat loads with temperature regulation above the phase change temperature

An apparatus and method for transferring thermal energy from a heat load is disclosed. In particular, use of a phase change material and specific flow designs enables cooling with temperature regulation well above the fusion temperature of the phase change material for medium and high heat loads from devices operated intermittently (in burst mode). Exemplary heat loads include burst mode lasers and laser diodes, flight avionics, and high power space instruments. Thermal energy is transferred from the heat load to liquid phase change material from a phase change material reservoir. The liquid phase change material is split into two flows. Thermal energy is transferred from the first flow via a phase change material heat sink. The second flow bypasses the phase change material heat sink and joins with liquid phase change material exiting from the phase change material heat sink. The combined liquid phase change material is returned to the liquid phase change material reservoir. The ratio of bypass flow to flow into the phase change material heat sink can be varied to adjust the temperature of the liquid phase change material returned to the liquid phase change material reservoir. Varying the flowrate and temperature of the liquid phase change material presented to the heat load determines the magnitude of thermal energy transferred from the heat load.

47 OTHER INSTRUMENTATION↗

A macroscopic relationship for preferential flow in the vadose zone: Theory and Validation

Preferential flow commonly observed in unsaturated soils allows rapid movement of solute from the ground surface or vadose zone to the groundwater, bypassing a significant volume of unsaturated soil and increasing the risk of groundwater contamination. A variety of evidence indicates that complex preferential flow patterns observed from fields are fractals. This paper discusses a macroscopic rela-tionship for modeling preferential flow in the vadose zone. Conceptually, the flow domain can be di-vided into active and inactive regions. Flow occurs preferentially in the active region (characterized by fractals), and inactive region is simply bypassed. The portion of the active region was found to be a power function of saturation. The validity of this macroscopic relationship is demonstrated by its consistency with field observations and the related numerical experiments.

54 ENVIRONMENTAL SCIENCES↗