Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKGROUND NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

SU-E-J-16: Automatic Image Contrast Enhancement Based On Automatic Parameter Optimization for Radiation Therapy Setup Verification

Purpose: In RT patient setup 2D images, tissues often cannot be seen well due to the lack of image contrast. Contrast enhancement features provided by image reviewing software, e.g. Mosaiq and ARIA, require manual selection of the image processing filters and parameters thus inefficient and cannot be automated. In this work, we developed a novel method to automatically enhance the 2D RT image contrast to allow automatic verification of patient daily setups as a prerequisite step of automatic patient safety assurance. Methods: The new method is based on contrast limited adaptive histogram equalization (CLAHE) and high-pass filtering algorithms. The most important innovation is to automatically select the optimal parameters by optimizing the image contrast. The image processing procedure includes the following steps: 1) background and noise removal, 2) hi-pass filtering by subtracting the Gaussian smoothed Result, and 3) histogram equalization using CLAHE algorithm. Three parameters were determined through an iterative optimization which was based on the interior-point constrained optimization algorithm: the Gaussian smoothing weighting factor, the CLAHE algorithm block size and clip limiting parameters. The goal of the optimization is to maximize the entropy of the processed Result. Results: A total 42 RT images were processed. The results were visually evaluated by RT physicians and physicists. About 48% of the images processed by the new method were ranked as excellent. In comparison, only 29% and 18% of the images processed by the basic CLAHE algorithm and by the basic window level adjustment process, were ranked as excellent. Conclusion: This new image contrast enhancement method is robust and automatic, and is able to significantly outperform the basic CLAHE algorithm and the manual window-level adjustment process that are currently used in clinical 2D image review software tools.

60 APPLIED LIFE SCIENCES↗

SU-E-J-215: Towards MR-Only Image Guided Identification of Calcifications and Brachytherapy Seeds: Application to Prostate and Breast LDR Implant Dosimetry

Purpose: To identify and analyze the appearance of calcifications and brachytherapy seeds on magnitude and phase MRI images and to investigate whether they can be distinguished from each other on corrected phase images for application to prostate and breast low dose rate (LDR) implant dosimetry. Methods: An agar-based gel phantom containing two LDR brachytherapy seeds (Advantage Pd-103, IsoAid, 0.8mm diameter, 4.5mm length) and two spherical calcifications (large: 7mm diameter and small: 4mm diameter) was constructed and imaged on a 3T Philips MR scanner using a 16-channel head coil and a susceptibility weighted imaging (SWI) sequence (2mm slices, 320mm FOV, TR/ TE= 26.5/5.3ms, 15 degree flip angle). The phase images were unwrapped and corrected using a 32×32, 2D Hanning high pass filter to remove background phase noise. Appearance of the seeds and calcifications was assessed visually and quantitatively using Osirix (http://www.osirix-viewer.com/). Results: As expected, calcifications and brachytherapy seeds appeared dark (hypointense) relative to the surrounding gel on the magnitude MRI images. The diameter of each seed without the surrounding artifact was measured to be 0.1 cm on the magnitude image, while diameters of 0.79 and 0.37 cm were measured for the larger and smaller calcifications, respectively. On the corrected phase images, the brachytherapy seeds and the calcifications appeared bright (hyperintense). The diameter of the seeds was larger on the phase images (0.17 cm) likely due to the dipole effect. Conclusion: MRI has the best soft tissue contrast for accurate organ delineation leading to most accurate implant dosimetry. This work demonstrated that phase images can potentially be useful in identifying brachytherapy seeds and calcifications in the prostate and breast due to their bright appearance, which helps in their visualization and quantification for accurate dosimetry using MR-only. Future work includes optimizing phase filters to best identify and delineate seeds and calcifications.

60 APPLIED LIFE SCIENCES↗

Parameter Estimation for Decoding Sensor Signals

This paper introduces a parameter estimation approach for decoding digital sensor signals in a cyber-physical system. For unknown or not fully characterized digital sensor data, it can be difficult to decipher a desired signal from background or noise. In a cyber-physical system with networked sensors, we can leverage knowledge of the physical system to inform the decoding of the digital signals. This work in progress is a case study on deciphering commercial vehicle on-board sensor networks that communicate through the Controller Area Network (CAN). By understanding the stock vehicle sensor network, a vehicle can be extended into a scalable research platform with minimal instrumentation. Our challenge was to localize desired sensor signals encoded in network traffic that included other sensor data, control messages, as well as encoding and security overhead. Due to the vehicle’s unknown sensor network, our approach developed methods to efficiently analyze and identify key signals despite the large state-space for potential signal embeddings.

Nice, Matthew↗

PhyCA-PhyloChip Analysis

PhyCA allows interpretation of a PhyloChip assay. It takes as input, a text file containing the fluorescent intensity from each feature on the microarray surface. PhyCA will determine the background and noise levels, compare probes against controls and determine response scores for each probe pair. It then summarizes a set of probe pair results to determine presence of an operational taxonomic unit as well as its abundance. The PhyCA software is novel from other microarray interpretation software from the following reasons: 1) It leverages spiked-in Quantitative Standards and non-spike-in Negative Controls to build a per-chip model of positive and non-positive responses. 2) It allows a refinement of Presence/Absence calls by evaluating each responding probe against a putative cross-hybridization network. 3) It can be used with phylogenetic microarrays designed for Bacteria, Archaea or Eukaryotes. Hardware req.: PC, MAC; Software req.: OS: Windows, Mac, Linux; Types of files: source code, control information; user guide. The software depends on other software to be installed on the same machine as PhyCA.

Desantis, Todd↗

Millisecond-long suppression of spectroscopic optical signals using laser filamentation

Ultrashort laser pulse filamentation in air can extend the delivery of focused laser energy to distances greatly exceeding the Rayleigh length. In this way, remote measurements can be conducted using many standard methods of analytical spectroscopy. The performance of spectroscopic techniques can be enhanced by temporal gating, which rejects the unwanted noise and background. In the present work, we investigate the thermal relaxation of air in the wake of single-filament plasmas using shadowgraphy. Here, we demonstrate that the transient change in refractive index associated with relaxation of the gas can be used to reject both continuous and time-varying spectroscopic signals, including emission from laser-produced plasmas. This method can augment temporal gating of simple optical detectors.

47 OTHER INSTRUMENTATION↗

T-1020: NaI Crystal Test for DM-Ice

This is a memorandum of understanding between the Fermi National Accelerator Laboratory (Fermilab) and the experimenters of the Nai Crystal Test for DM-Ice from the University of Wisconsin who have committed to participate in detector tests to be carried out during the 2011 — 2012 Fermilab Neutrino program. The memorandum is intended primarily for the purpose of recording expectations for budget estimates and work allocations for Fermilab, the funding agencies and the participating institutions. It reflects an arrangement that currently is satisfactory to the parties; however, it is recognized and anticipated that changing circumstances of the evolving research program will necessitate revisions. The parties agree to modify this memorandum to reflect such required adjustments. Actual contractual obligations will be set forth in separate documents. The DM-Ice collaboration is designing a sodium-iodide (Nai) based detector for a direct dark matter search. The detectors should have low readout noise and background levels to carry out a sensitive search. A 17-kg version of the experiment is running at the South Pole, 2500 m deep in the Antarctic ice, and a larger scale experiment is currently being designed. One of the keys to the success of the experiment is to have a good understanding of the background levels intrinsic in the Nai detectors. To measure the background level, the detectors have to be shielded against cosmic rays. The lead shielding used for DAMIC (see T-987) in the Minos Underground Areas is a well-suited location for this test since it offers enough overburden to shield against cosmic rays, lead shielding, and experimental infrastructure.

47 OTHER INSTRUMENTATION↗

Interim Report on the Optimization and Feasibility Studies for the Neutron Detection without Helium-3 Project

This report details the results of the work accomplished for the „Neutron Detection without Helium-3‟ project during the 2011 fiscal year. The primary focus of the project during this year was to develop models using alternatives to helium-3 to investigate the possibilities and optimizations for multiplicity counters in safeguards applications by computer simulations. The multiplicity counter with significant capability, the Epithermal Neutron Multiplicity Counter (ENMC), was used as the baseline requirement for alternative technologies, which, if a suitable alternative can be found, should also satisfy systems with less stringent requirements, including coincidence counters. The project is in collaboration with Los Alamos National Laboratory (LANL), and the baseline model of the ENMC that had been developed at LANL with helium-3 as the detector material was used as a starting point. The model was modified to support optimization investigations, and verified with the helium-3 base material. The model was then modified to incorporate boron-trifluoride (BF3) gas, which can be used as a proportional gas similar to helium-3. The BF3 gas however, cannot be operated at very high pressure, and therefore optimization were performed with lower pressures and involved changing the tube size and number. The simulation of this model is very similar in approach to the model with helium-3 where the simulation ends when the neutron is captured in the boron. The reaction products are easily detected in the proportional gas, and the simulation results of counting the number of reactions matches well with experimental data. Next, the tubes were replaced with boron-lined proportional tubes, where the neutron capture material is a thin boron lining inside the tube wall, and which use standard proportional counting gas. For this alternative, the simulation needs to extend beyond the neutron capture, and track the reaction products, which must exit the boron-lining into the counting gas. The reaction products do not always end up in the counting gas, depending on the boron-lining thickness and neutron capture depth. Methods to track the reaction products have been recently implemented into MCNPX and were verified by using several different approaches. The tube number and size were also varied for the boron-lined case. Finally, work has started on a model of an alternative using lithium-6, another material with a high cross-section for thermal neutron capture. The most promising approach is with lithium fluoride in a zinc sulfide (silver activated) scintillator medium. The neutron is captured in the lithium, and the reaction products trigger scintillation light in the zinc sulfide, which is subsequently detected by photo-multipliers by the use of light guides or fibers. The simulations were performed with the focus on determining the efficiency, which is critical when detecting 2 or 3 neutrons in coincidence, as well as the die-away time, which is a measure of the time required to capture neutrons in the system. The die away time is related to the coincident time gate needed for the system which drives the accidental coincident rate, the primary background or noise in this type of measurement. The usual figure of merit for coincidence type systems, the efficiency squared divided by the die-away time, was calculated for each variation simulated.

helium-3 alternatives↗

Waveform dependence on signal amplitude in the RHIC H-Jet polarimeter

A simulation of the signal waveform in the H-Jet polarimeter is discussed. The simulation includes a model of charge collection in the silicon detector and a response functions of the H-Jet front end electronics. Results of the simulation are compared with experimental data. It is shown that an analysis of the signal shape may help to suppress background in the H-Jet polarization measurements.

43 PARTICLE ACCELERATORS↗

Collaborative Research: Equipment for and Running of the PSI MUSE Experiment

The R&D funding from this award has been a significant tool to move the Muon Scattering Experiment (MUSE) at the Paul Scherrer Institute in Switzerland forward to the stage of realization. Specifically, this award has enabled Dr. Michael Kohl and his working group at Hampton University to achieve substantial progress toward the goal of providing beam particle tracking with Gas Electron Multiplier (GEM) detectors for MUSE experiment. Establishing a particle detection system that is capable of operating in a high-intensity environment, with a data acquisition system capable of running at several kHz, combined with robust tracking software providing high efficiency for track reconstruction in the presence of noise and backgrounds will have immediate application in many other experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hunting Sub-GeV Dark Matter with Diamonds and Magnetic Microcalorimeters Principle

This project is to study feasibility of a new concept for the sub-GeV dark matter (DM) detection using diamond crystals and magnetic microcalorimeters (MMCs). Diamond crystals are made of low mass carbon constituent that maximize kinetic energy of nuclear recoils from sub-GeV DM scattering due to their relatively similar masses. MMC is employed as a sensitive phonon sensor to measure athermal phonons that are produced by DM scattering in diamond crystals with 100 ns timing resolution and ~10 eV energy resolution. MMC’s fast timing resolution allows high precision phonon pulse shape analysis to separate out unwanted background or noise signals in the low energy region at E < 1 keV. Especially, the low energy excess (LEE) problems have been reported in the dark matter detection community and the proposed diamond-MMC detector might be able to provide important information to understand the origins of LEE signals in DM detectors. In this project a diamond-MMC detector has been built for proof-of-concept experiments and athermal phonon collection efficiencies have been investigated for single crystal and poly-crystal chemical-vapour-diamonds (SC and PC CVDs) as well as reference sapphire crystals are tested in the same geometries to quatify athermal phonon propagation and their collection to the MMC phonon sensors. Athermal phonon collection efficiencies and their lifetime in the diamond and sapphire crystals are successfully measured in the same geometry and experimental setup for comparison. SC CVD crystals exhibit poorer performance than the sapphire reference crystals in athermal phonon collection, while the PC CVD crystal exhibit better result than the sapphire. PC CVD with MMC phonon sensors would be feasible for sub GeV DM detection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lightning Interferometry with the Long Wavelength Array

The Long Wavelength Array is a radio telescope array located at the Sevilleta National Wildlife Refuge in La Joya, New Mexico, well suited and situated for the observation of lightning. The array consists of 256 high-sensitivity dual polarization antennas arranged in a 100 m diameter. This paper demonstrates some of the capabilities that the array brings to the study of lightning. Once 32 or more antennas are used to image lightning radio sources, virtually every integration period longer than the impulse response of the array includes at least one identifiable lightning emitter, independent of the integration period used. The use of many antennas also allows multiple simultaneous lightning radio sources to be imaged at sub-microsecond timescales; for the flash examined, 51% of the images contained more than one lightning source. Finally, by using many antennas to image lightning sources, the array is capable of locating sources fainter than the galactic background radio noise level, yielding possibly the most sensitive radio maps of lightning to date. This incredible sensitivity enables, for the first time, the emissions originating from the positive leader tips of natural in-cloud lightning to be detected and located. The tip emission is distinctly different from needle emission and is most likely due to positive breakdown.

Stock, Michael (ORCID:0000000193336790)↗

SN 1986J VLBI. III. The Central Component Becomes Dominant

We present a new 5 GHz global very-long-baseline interferometry (VLBI) image of supernova 1986J, observed in 2014 at t = 31.6 yr after the explosion, and compare it to previous images to show the evolution of the supernova. Our new image has a dynamic range of ∼100 and a background rms noise level of 5.9 μJy beam{sup −1}. There is no significant linear polarization, with the image peak <3% polarized. The latest image is dominated by a compact central component, whose flux density is now comparable to that of the extended supernova shell. This central component is marginally resolved with an FWHM of 900{sub −500}{sup +100} μas, corresponding to a radius of r{sub comp}=6.7{sub −3.7}{sup +0.7}×10{sup 16} cm for a distance of 10 Mpc. Using VLBI observations between 2002 and 2014, we measured the proper motions of both the central component and a hot spot to the NE in the shell relative to the quasar 3C 66A. The central component is stationary to within the uncertainty of 12 μas yr{sup −1}, corresponding to 570 km s{sup −1}. Our observations argue that the central component is located near the physical center of SN 1986J. The shell hot spot had a mean velocity of 2810 ± 750 km s{sup −1} to the NE, which is consistent with its taking part in the homologous expansion of the shell seen earlier. The shell emission is evolving in a non-self-similar fashion, with the brightest emission shifting inward within the structure and with only relatively faint emission seen near the outer edge and the presumed forward shock. An animation of the explosion is available.

79 ASTRONOMY AND ASTROPHYSICS↗

Variability, timescales, and nonlinearity in climate responses to black carbon emissions

Black carbon (BC) particles exert a potentially large warming influence onthe Earth system. Reductions in BC emissions have attracted attention as apossible means to moderate near-term temperature changes. For the first time,we evaluate regional climate responses, nonlinearity, and short-termtransient responses to BC emission perturbations in the Arctic, midlatitudes,and globally based on a comprehensive set of emission-driven experimentsusing the Community Earth System Model (CESM). Surface temperature responsesto BC emissions are complex, with surface warming over land from midlatitudeBC perturbations partially offset by ocean cooling. Climate responses do notscale linearly with emissions. While stronger BC emission perturbations havea higher burden efficiency, their temperature sensitivity is lower. BCimpacts temperature much faster than greenhouse gas forcing, with transienttemperature responses in the Arctic and midlatitudes approaching aquasi-equilibrium state with a timescale of 2–3 years. We find largevariability in BC-induced climate changes due to background model noise. As aresult, removing present-day BC emissions results in discernible surfacetemperature changes for only limited regions of the globe. In order to betterunderstand the climatic impacts of BC emissions, both the drivers ofnonlinear responses and response variability need to be assessed acrossclimate models.

54 ENVIRONMENTAL SCIENCES↗

Infrared Astronomical Satellite

The objective of the Infrared Astronomical Satellite is to produce an unbiased all-sky survey in the wavelength region between 8 and 120 microns. Using a 60 cm diameter helium cooled telescope and detector arrays which are essentially zodiacal light background photon noise limited, heretofore unprecedented sensitivity can be achieved. The optical design, the focal plane layout and expected performance of the current design concept are discussed.

Aumann, H. H.↗

Results from the July 1981 Workshop on Passive Remote Sensing of the Troposphere

Potential roles of passive remote sensors in the study of the chemistry and related dynamics of the lower atmosphere were defined by a Tropospheric Passive Remote Sensing Workshop, and technology advances required to implement these roles were identified. A promising role is in making global-scale, multilayer measurements of the more abundant trace tropospheric gaseous species (e.g., O3, CO, CH4, HNO3) and of aerosol thickness and size distribution. It includes both nadirand limb-viewing measurements. Technology advances focus on both scanning- and fixed-spectra, nadir-viewing techniques with resolutions of 0.1 kaysers or better. Balloon- and Shuttle-borne experiments should be performed to study the effects of instrument noise and background fluctuations on data inversion and to determine the utility of simultaneously obtained nadir- and limb-viewing data.

Keafer, L. S., Jr.↗

Differentially coherent detection of QASK for frequency-hopping systems. I - Performance in the presence of a Gaussian noise environment

Bandwidth-conserving modulation techniques, which trade average power for bandwidth in a favorable exchange, have recently found widespread application in digital radio and satellite communication systems. Quadrature amplitude-shift-keying (QASK) is a particular type of the considered techniques. QASK makes use of multilevel signals to amplitude modulate the in-phase and quadrature components of a carrier. Frequency hopping (FH) is used to protect a conventional communication system from radio frequency interference (RFI) or jamming. Differentially coherent detection provides a possible solution to the effect of phase discontinuities introduced by FH. The application of such a detection technique to QASK signals is discussed. A receiver structure is proposed and its symbol error probability performance for an additive white Gaussian noise (AWGN) background is investigated.

Simon, M. K.↗