At least 721 records · Page 40

Optics measurement and correction during beam acceleration in the Relativistic Heavy Ion Collider

To minimize operational complexities, setup of collisions in high energy circular colliders typically involves acceleration with near constant β-functions followed by application of strong focusing quadrupoles at the interaction points (IPs) for the final beta-squeeze. At the Relativistic Heavy Ion Collider (RHIC) beam acceleration and optics squeeze are performed simultaneously. In the past, beam optics correction at RHIC has taken place at injection and at final energy with some interpolation of corrections into the acceleration cycle. Recent measurements of the beam optics during acceleration and squeeze have evidenced significant beta-beats which if corrected could minimize undesirable emittance dilutions and maximize the spin polarization of polarized proton beams by avoidance of higher-order multipole fields sampled by particles within the bunch. In this report the methodology now operational at RHIC for beam optics corrections during acceleration with simultaneous beta-squeeze will be presented together with measurements which conclusively demonstrate the superior beam control. As a valuable by-product, the corrections have minimized the beta-beat at the profile monitors so reducing the dominant error in and providing more precise measurements of the evolution of the beam emittances during acceleration.

43 PARTICLE ACCELERATORS↗

Muon Accelerator Program Simulation Fellow

Muons are fundamental particles like electrons but much more massive. Muon accelerators can provide physics opportunities similar to those of electron accelerators, but because of the larger mass muons lose less energy to radiation, allowing more compact facilities with lower operating costs. The way muon beams are produced makes them too large to fit into the vacuum chamber of a cost-effective accelerator, and the short muon lifetime means that the beams must be reduced in size rather quickly, without losing too many of the muons. This reduction in size is called "cooling." Ionization cooling is a new technique that can accomplish such cooling. Intense muon beams can then be accelerated and injected into a storage ring, where they can be used to produce neutrino beams through their decays or collided with muons of the opposite charge to produce a muon collider, similar to an electron-positron collider. We report on the research carried out at the University of California, Riverside, towards producing such muon accelerators, as part of the Muon Accelerator Program based at Fermilab. Since this research was carried out in a university environment, we were able to involve both undergraduate and graduate students.

43 PARTICLE ACCELERATORS↗

Observation of 690 MV m -1 Electron Accelerating Gradient with a Laser-Driven Dielectric Microstructure

Acceleration of electrons using laser-driven dielectric microstructures is a promising technology for the miniaturization of particle accelerators. In this work, experimental results are presented of relativistic electron acceleration with 690±100 MVm -1 gradient. This is a record-high accelerating gradient for a dielectric microstructure accelerator, nearly doubling the previous record gradient. To reach higher acceleration gradients the present experiment employs 90 fs duration laser pulses.

43 PARTICLE ACCELERATORS↗

Direct Acceleration of an Electron Beam with a Radially Polarized Long-Wave Infrared Laser

Direct laser acceleration with radially polarized lasers is an intriguing variant of laser-based particle acceleration that has the potential of offering GeV/cm-level energy while avoiding the instabilities and complex beam dynamics associated with plasma wakefield accelerators. A major limiting factor is the difficulty of generating high-power radially polarized beams. In this paper, we propose the use of CO2-based long-wave infrared (LWIR) lasers as a driver for direct laser acceleration, as the polarization insensitivity of the gain medium allows a radially polarized beam to be amplified. Additionally, the larger waist sizes, Rayleigh lengths, and pulse lengths associated with the long wavelength could improve the injection efficiency of the electron beam. By comparing acceleration simulations using a near-infrared laser and an LWIR laser, we show that the injection efficiency is indeed improved by up to an order of magnitude with the longer wavelength. Furthermore, we show that even sub-TW peak powers with an LWIR laser can provide MeV-level energy gains. Thus, radially polarized LWIR lasers show significant promise as a driver of a direct laser-driven demonstration accelerator.

43 PARTICLE ACCELERATORS↗

The research progress of some key problems about the protection of industrial electron irradiation accelerator - Paper 9

In the last decades, electronic irradiation accelerator has made great progress and been widely used in fields. Because of its distinguishing feature of reliability and safety, electronic irradiation accelerator has attracted more attention of the investors, and created a huge economic value and social benefits. It will become the mainstream equipment of irradiation processing industry in future. So the further study of the shielding design around irradiation accelerator is of great significance. Different designs of ventilation duct will greatly influence dose rate of the exit. Because of the high dose rate under the target, it is suitable to use multi-tortuous duct when duct locating under target. It will reduce the dose rate about 3 orders of magnitude at the exit that add one backscattering interface in duct. Choose reasonable diameter and angle of embedded duct so that photons scatter as much as possible. We can use multiple small diameter ducts to replace large diameter duct. The system of Mini-DDL, Gamma detector and PC give a better reflection on the running statue of accelerator, its perfect usability can produce intuitive images for analyzed, it is important and helpful for workers and researchers to know about the radiation level of machine and environment. The measured results along the maze show that the maze must be long enough in order to achieve the desired shielding thickness. In future, we will combine the different kinds and motor patterns of body models, Monte Carlo programs, real time monitoring system with theoretical calculations to explore how the radiation field around accelerator has impact on human organs, get the dose distribution of body models so that improve the radiation protection to electron accelerator. (authors)

43 PARTICLE ACCELERATORS↗

Determination of activation products and resulting decommissioning implications for the Varian TruBeam linear accelerator - Paper 52

Modern medical linear accelerators used for the treatment of cancers are capable of operating at electron energies as high as 20 MeV. Above electron energies of 6 MeV, a measurable dose rate is obtained at the isocenter after beam termination. This is attributed to the activation of linear accelerator components through photonuclear reactions and neutron capture. Photons are produced as Bremsstrahlung during the collision of high-energy electrons with a heavy metal target, typically comprised of copper or tungsten. When photons exceeding the nucleon binding energy interact with a nucleus, neutrons are ejected. In the process of neutron capture, neutrons produced through ({gamma}, n) reactions are absorbed by a nucleus and the excess energy is emitted as a photon. Over the lifetime of an accelerator many components, such as the target, flattening filter, collimators, jaws, and treatment couch, are activated through these interactions. Although dependent on operating conditions, linear accelerators have an expected lifetime of 7 to 10 years. In Canada, at the end of their service, accelerators are typically sold for scrap, returned to a remanufacturing enterprise, or if the machine is still operational it can be retasked for continued use. Since many of the accelerator components have been exposed to a neutron fluence and activated to various extents, the requirements of the Canadian Nuclear Substance and Radiation Device regulations apply prior to final removal from the hospital. For shipments to the USA, there are exemption regulations to be considered. NRC regulation 10CFR 30.71 Schedule B lists a number of common radionuclides and the specific exemption quantity. Below these levels, radioactive materials may be freely transported from Canada to the USA without prior licensing from the Canadian Nuclear Safety Commission (CNSC) or United States Nuclear Regulatory Commission (NRC). (authors)

43 PARTICLE ACCELERATORS↗

Experimental parameters for plasma wakefield acceleration in a narrow plasma column

Recent theoretical advancements propose multiple positron acceleration schemes in plasma wakefield acceleration (PWFA). One of the most promising ideas involves the creation of an electron-driven blowout wake within a finite-radius pre-ionized plasma column. This leads to the formation of an elongated region of sheath electrons at the closing of the first wake period capable of accelerating positrons while simultaneously providing a transverse focusing force. Additionally, the proposed scheme has shown to be a potential means of suppressing instabilities. We present an experimental opportunity to explore the narrow column PWFA at the Facility for Advanced Accelerator Experimental Tests II (FACET-II): the E333 experiment. As a pivotal first step towards achieving positron acceleration in PWFA, we have planned a precursor experiment utilizing the currently available single-bunch electron beam to study the physics of the narrow plasma PWFA scheme. We outline the feasible experimental parameters, including beam and ionization laser parameters, along with the required laser optics for the experiment. The primary observable signatures for this stage of the experiment are the final energy spectrum and transverse position of the electron bunch, anticipating reduced energy loss and enhanced beam guidance in the narrow plasma column compared to the nominal PWFA. Comprehensive simulations are used to detail our experimental plan.

Lee, Valentina [University of Colorado, Boulder, C↗

Plasma-wakefield accelerator simultaneously boosts electron beam energy and brightness

High-energy particle colliders and X-ray free-electron lasers demand electron beams with qualities currently achieved only in kilometer-scale radio-frequency accelerators. Plasma accelerators promise a compact alternative but have faced challenges in delivering the needed beam quality at relevant energies. Here, we demonstrate that a plasma-wakefield accelerator operating in the nonlinear regime acts as a transformer to simultaneously boost the energy and brightness of an electron bunch injected from the plasma. Using a 10-GeV drive bunch and a three-stage meter-scale plasma source, we generated electron bunches exceeding 20 GeV with sub-percent energy spread, 2 mm·mrad normalized emittance, and multi-kA peak current. A significant number of drive-bunch electrons lost over 90% of their energy, a prerequisite for high energy-conversion efficiency. This demonstration of an energy transformer ratio exceeding two and a brightness enhancement over an order of magnitude opens a path towards cost-effective accelerators for future colliders and light sources.

experimental particle physics↗

Space-Borne Electron Accelerator Design

Renewed interest in active experiments with relativistic particle beams in space has led to the development of solid-state radio-frequency (RF) linear accelerators (linac) that can deliver MeV electron beams but operate with low-voltage DC power supplies. The solid-state RF amplifiers used to drive the accelerator are known as high-electron mobility transistors (HEMTs), and at C-band (5–6 GHz) are capable of generating up to 500 watts of RF power at 10% duty factor in a small package, i.e., the size of a postage stamp. In operation, the HEMTs are powered with 50 V DC as their bias voltage; they thus can tap into the spacecraft batteries or electrical bus as the primary power source. In this paper we describe the initial testing of a compact space-borne RF accelerator consisting of individual C-band cavities, each independently powered by a gallium nitride (GaN) HEMT. We show preliminary test results that demonstrate the beam acceleration in a single C-band cavity powered by a single HEMT operating at 10% duty factor. An example of active beam experiments in space that could benefit from the HEMT-powered accelerators is the proposed Magnetosphere-Ionosphere Connection (CONNEX) experiment (Dors et al., 2017).

43 PARTICLE ACCELERATORS↗

Leveraging prior mean models for faster Bayesian optimization of particle accelerators

Tuning particle accelerators is a challenging and time-consuming task that can be automated and carried out efficiently using suitable optimization algorithms, such as model-based Bayesian optimization techniques. One of the major advantages of Bayesian algorithms is the ability to incorporate prior information about beam physics and historical behavior into the model used to make control decisions. In this work, we examine incorporating prior accelerator physics information into Bayesian optimization algorithms by utilizing fast executing, neural network models trained on simulated or historical datasets as prior mean functions in Gaussian process models. We show that in ideal cases, this technique substantially increases convergence speed to optimal solutions in high-dimensional tuning parameter spaces. Additionally, we demonstrate that even in non-ideal cases, where prior models of beam dynamics do not exactly match experimental conditions, the use of this technique can still enhance convergence speed. Finally, we demonstrate how these methods can be used to improve optimization in practical applications, such as transferring information gained from beam dynamics simulations to online control of the LCLS injector, and transferring knowledge gained from experimental measurements across different operating modes, such as accelerating different ion species at the ATLAS heavy ion accelerator.

43 PARTICLE ACCELERATORS↗

Particle Acceleration by Magnetic Reconnection in Geospace

Particles are accelerated to very high, non-thermal energies during explosive energy-release phenomena in space, solar, and astrophysical plasma environments. While it has been established that magnetic reconnection plays an important role in the dynamics of Earth’s magnetosphere, it remains unclear how magnetic reconnection can further explain particle acceleration to non-thermal energies. Here we review recent progress in our understanding of particle acceleration by magnetic reconnection in Earth’s magnetosphere. With improved resolutions, recent spacecraft missions have enabled detailed studies of particle acceleration at various structures such as the diffusion region, separatrix, jets, magnetic islands (flux ropes), and dipolarization front. With the guiding-center approximation of particle motion, many studies have discussed the relative importance of the parallel electric field as well as the Fermi and betatron effects. However, in order to fully understand the particle acceleration mechanism and further compare with particle acceleration in solar and astrophysical plasma environments, there is a need for further investigation of, for example, energy partition and the precise role of turbulence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accelerating the solution of the S N equations with highly anisotropic scattering using the Fokker-Planck approximation

The discrete ordinates method can model forward-peaked transport problems accurately. However, convergence of discrete ordinates solution can become arbitrarily slow upon use of standard iterative procedures like source iteration. Standard zeroth and first moment-based acceleration methods like nonlinear diffusion acceleration and diffusion synthetic acceleration are ineffective in accelerating such problems because these methods do not correct higher order Legendre-moments of angular flux. In this paper, we explore the idea of using the Fokker-Planck approximation as a preconditioner to accelerate the convergence of solution of forward-peaked transport problems. Finally, we observe that such preconditioning can successfully reduce the iteration count by up to four orders of magnitude, and solver runtime by up to three orders of magnitude when compared to diffusion synthetic acceleration.

42 ENGINEERING↗

Response of a uniformly accelerated detector to massless Rarita–Schwinger fields in vacuum

We study the response of a uniformly accelerated detector modeled by a two-level atom nonlinearly coupled to vacuum massless Rarita–Schwinger fields. We first generalize the formalism developed by Dalibard, Dupont-Roc, and Cohen-Tannoudji in the linear coupling case, and we then calculate the mean rate of change of the atomic energy of the accelerated atom. Our result shows that a uniformly accelerated atom in its ground state interacting with vacuum Rarita–Schwinger field fluctuations would spontaneously transition to an excited state and the unique feature in contrast to the case of the atom coupled to the scalar, electromagnetic and Dirac fields is the appearance of terms in the excitation rate which are proportional to the sixth and eighth powers of acceleration. - Highlights: • We study the response of an accelerated detector to Rarita–Schwinger fields. • Detector spontaneously transitions to an excited state in vacuum. • Excitation rate contains terms of the sixth and eighth powers of acceleration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of spraying on the early hydration of accelerated cement pastes

In practice, most of the studies about the interaction between cement and accelerators is performed with hand-mixed pastes. However, in many applications mixing occurs through spraying, which may affect accelerators reactivity and the microstructure of the hardened paste. The objective of this study is to analyze how the mixing process influences the early hydration of accelerated cement pastes. Isothermal calorimetry, X-ray diffraction, thermogravimetry and SEM imaging were performed on cement pastes produced by hand-mixing and by spraying, using equivalent doses of an alkali-free and an alkaline accelerator and two types of cement. Results showed a great influence of the spraying process on the reactivity of accelerators and on the morphology of the precipitated hydrates. Variations in hydration kinetics caused by the mixing method are explained and the results obtained might have a significant repercussion on how future research on the behavior of accelerated mixes will be performed.

36 MATERIALS SCIENCE↗

Application of laser-driven capacitor-coil to target normal sheath acceleration

A laser-driven accelerator generates protons with tens of MeV in energy by a compact, strong, and transient accelerating electric field produced as a result of laser–plasma interactions at relativistic intensities. In previous studies, two- and three-dimensional particle-in-cell simulations revealed that the application of a kT-level axial magnetic field results in an enhancement of proton acceleration via the target normal sheath acceleration mechanism due to reduced lateral electron divergence and improved electron heating efficiency. An experimental investigation of this scheme on the GEKKO-XII and the LFEX facilities found that the number and maximum energy of the accelerated protons decreased with increasing the temporal delay between the pulse driving the external magnetic-field and the pulse accelerating the protons, contrary to the theoretical and numerical expectations. Finally, we identify sources responsible for the degradation of the proton beam performance and we propose an alternative experimental setup to mitigate the degradation in future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

When and how to treat an IMRT patient on a second accelerator without replanning?

When a linear accelerator is unavailable for treatment, a clinical decision is imminent regarding whether a patient should be treated on a linear accelerator other than the machine the patient was scheduled on, or whether treatment should be postponed until the original Linac becomes available. This work investigates the feasibility of switching patients to different accelerators for intensity-modulated radiation therapy (IMRT). We have performed Monte Carlo simulations of photon beams from different Linac models and vendors. Prostate and head and neck (H&N) treatment plans for Siemens Primus, Primart, and Varian 21EX accelerators are studied in this work. Dose distributions for given plans are recalculated using different beam data with the same nominal energy from different Linacs. We have compared dose-volume histograms (DVHs) and the maximum, the minimum, and the mean doses to the target and critical structures because of switching accelerators. In the process of switching a treatment plan to a different accelerator, issues exist, including optimum penumbra compensation, dose distribution at the boundary of target and critical structures, and multileaf collimator (MLC) leaf-width effects, which need to be considered and verified with measurements. Our Monte Carlo simulation results confirm that, for the cases we tested, the dose received by 95% of the planning target volume differs by 0.2% to 1.5% between Siemens Primus and Varian 21EX Linacs. The discrepancy is within our clinical acceptance criteria of 3% for IMRT treatments. In making the final decision on whether to switch machines or not, the tumor control probabilities (TCPs) based on a linear-quadratic model are compared. Based on the analyses performed in this work, it is therapeutically more beneficial to switch a patient to a different machine than to postpone a treatment until the original machine is available, especially for fast-growing tumors such as H&N cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerated test protocols to predict service life and durability of solid oxide fuel cells

Reliable accelerated test protocols are needed for solid oxide fuel cell research to facilitate rapid learning on key durability issues, identify potential modes of failure expeditiously, and eventually predict the calendar lifetime of an electrochemical cell. In this work, solid oxide fuel cells operated at a constant current density were compared to cells undergoing accelerated measurements, which are composed of intermittent current injection to the cell. A general accelerated test profile was developed by cycling a solid oxide fuel cell from open circuit to a predetermined operating current density that is the same as the current density during a steady-state operation, to accelerate the local redox environment. The following parameters were studied: current density, operation temperature, moist level, sintering temperature, cycling current, cycling frequency, and operation time. Up to 1,320,000 cycles were generated in this work. The cell degradation was accelerated by nearly 10 times, suggesting the feasibility of using this protocol for acceleration test to predict life performance and durability of solid oxide fuel cells.

08 HYDROGEN↗

Generation and acceleration of electron bunches from a plasma photocathode

Plasma waves generated in the wake of intense, relativistic laser or particle beams can accelerate electron bunches to gigaelectronvolt energies in centimetre-scale distances. This allows the realization of compact accelerators with emerging applications ranging from modern light sources such as the free-electron laser to energy frontier lepton colliders. In a plasma wakefield accelerator, such multi-gigavolt-per-metre wakefields can accelerate witness electron bunches that are either externally injected or captured from the background plasma. Here in this work, we demonstrate optically triggered injection and acceleration of electron bunches, generated in a multi-component hydrogen and helium plasma employing a spatially aligned and synchronized laser pulse. This ‘plasma photocathode’ decouples injection from wake excitation by liberating tunnel-ionized helium electrons directly inside the plasma cavity, where these cold electrons are then rapidly boosted to relativistic velocities. The injection regime can be accessed via optical density down-ramp injection and is an important step towards the generation of electron beams with unprecedented low transverse emittance, high current and 6D-brightness. This experimental path opens numerous prospects for transformative plasma wakefield accelerator applications based on ultrahigh-brightness beams.