Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Chemistry of Ionic Silver and Implications for Design of Potable Water Systems

Ionic silver (Ag+) at approximately 400 µg/L is proposed as an ingestible biocide for potable water systems in future human spacecraft. This paper investigates the underlying chemistry of the silver ion at potable concentrations and its interactions with other solutes and surfaces. This chemistry evaluation will elucidate ionic silver behavior in potable water systems and enable design optimization to minimize ionic silver depletion during long duration crewed and uncrewed segments of missions. Ionic silver can be lost from the water phase to the water-solid interface via adsorption as the cation and oxidation-reduction reactions with passivation defects. The adsorption and oxidation-reduction reactions of heritage piping materials used on spacecraft – stainless steel 316L, titanium, Inconel 718, and Teflon flex hoses – are considered. Conceptual models of adsorption isotherms and pH adsorption edges are applied to understand the role of pH and the surface-to-volume ratio of pipes and tanks on the partitioning of ionic silver between the aqueous and the solid phase during aging. The effect of repeated exposure-aging to an Ag+ containing solution of two passivated alloys (316L and Inconel 718) is evaluated to determine if an equilibrium concentration of ionic silver in the potable range is attainable for a given alloy and surface-to-volume ratio. Aging unpassivated and passivated 316L reduced the ionic silver depletion rate relative to first time exposures, but the same beneficial effect was not observed for Inconel 718.

Water↗

Corrosion control and disinfection studies in spacecraft water systems

Disinfection and corrosion control in the water systems of the Saturn 5 Orbital Workshop Program are considered. Within this framework, the problem areas of concern are classified into four general areas: disinfection; corrosion; membrane-associated problems of disinfectant uptake and diffusion; and taste and odor problems arising from membrane-disinfectant interaction.

Shea, T. G.↗

Editorial: Themed issue on data-intensive water systems management and operation

The water sector increasingly looks at intensified instrumentation, data collection and automation as tools for daily use. Still, a massive opportunity remains to fully embrace emerging methods and technologies, such as artificial intelligence, data analytics, low-cost sensor hardware, and cloud computing. Indeed, sensing and automation technology has already infiltrated many facets of society. As such, the time is ripe to evaluate the role of novel technologies for systems monitoring, diagnostics, and automation of aquatic processes and large-scale water systems. When leveraged, the water sector will do more with less.

54 ENVIRONMENTAL SCIENCES↗

Calorimetric studies of the ammonia-water system with application to the outer solar system

A series of heating experiments was performed on the condensed ammonia-water system using a differential scanning calorimeter (DSC). The water-rich samples were cooled quickly to below 130 K, then heated at a variety of rates. Rather than a single peritectic melt at 176 K, expected for the equilibrium system of water ice and ammonia dihydrate, four enthalpic transitions were repeatedly seen in the temperature range 150-176 K. These transitions are generally consistent with the earlier calorimetric results of Van Kasteren (1973), who interpreted the lowest temperature exotherm as crystallization of an amorphous ammonia-water compound formed during cooling. We propose that both sets of experiments are seeing the crystallization of ammonia monohydrate, which is metastable relative to the dihydrate, followed by partial remelting and crystallization of dihydrate upon further heating. The apparent stability of the monohydrate in the dihydrate equilibrium field implies a potentially complex behavior of ammonia-water ices in satellites. Possible self-heating of the mixture by several tens of degrees up to the 170 K eutectic could make mobilization of ammonia-water liquids in icy satellite interiors energetically easier than previously thought.

Yarger, Jeffery↗

Tritium Production Estimates in EIC Cooling Water Systems

Annual tritium production in EIC cooling water has been estimated in one sextant cooling system from expected electron beam and proton beam losses in the tunnel. Beam losses and the secondary particles they produce are the only source within the RHIC Tunnel for producing radioactivity in cooling water, including tritium. The need to estimate tritium production supports decisions on whether cooling water systems are required to meet Suffolk County Article 12 requirements (e.g., double-walled piping, leak detection and containment, etc.). Results are extended to the remaining sextant cooling water systems because of the similarity in tunnel cooling water loads and system volumes.

43 PARTICLE ACCELERATORS↗

A Review of Resilience and Long-Term Planning in Power and Water Systems in the United States

There is recognition among power and water utilities that the frequency and magnitude of high consequence and low probability events could increase as a result of climate change. The interconnected nature of energy-water systems raises the possibility of cascading failures, increasing complexity and risks. Resilience and long-term planning are important ways of weathering the effects of climate change. First, to understand more about resilience, we reviewed existing literature on resilience definitions, metrics, and modeling, focusing on integrated water-power systems. Second, to understand how resilience and planning are being applied in practice, we interviewed utilities and organized, curated, and synthesized the interview data to arrive at several key findings, which are presented here. We found that there is not a consistent definition for resilience, yet it is something that utilities regularly plan for, often with different names and varying methods/measures. However, there is a tangible shift in the industry towards defining and determining measurable resilience metrics. While the exact metrics are a work in progress, utilities are taking steps forward by (1) putting people and culture at the center of resilience, (2) recognizing their own interdependencies, and (3) pursuing better cross-sector collaboration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advanced Exploration Systems Water Architecture Study Interim Results

The mission of the Advanced Exploration System (AES) Water Recovery Project (WRP) is to develop advanced water recovery systems that enable NASA human exploration missions beyond low Earth orbit (LEO). The primary objective of the AES WRP is to develop water recovery technologies critical to near-term missions beyond LEO. The secondary objective is to continue to advance mid-readiness-level technologies to support future NASA missions. An effort is being undertaken to establish the architecture for the AES Water Recovery System (WRS) that meets both near- and long-term objectives. The resultant architecture will be used to guide future technical planning, establish a baseline development roadmap for technology infusion, and establish baseline assumptions for integrated ground and on-orbit Environmental Control and Life Support Systems definition. This study is being performed in three phases. Phase I established the scope of the study through definition of the mission requirements and constraints, as well as identifying all possible WRS configurations that meet the mission requirements. Phase II focused on the near-term space exploration objectives by establishing an International Space Station-derived reference schematic for long-duration (>180 day) in-space habitation. Phase III will focus on the long-term space exploration objectives, trading the viable WRS configurations identified in Phase I to identify the ideal exploration WRS. The results of Phases I and II are discussed in this paper.

Sargusingh, Miriam J.↗

Solar hot water system installed at Day's Lodge, Atlanta, Georgia

The solar energy hot water system installed in the Days Inns of America, Inc., Atlanta, Georgia is described. This system provides for 81 percent of the total hot water demand. There are two separate systems, each serving one building of the lodge (total of 65 suites). The entire system contains only potable city water. The 1024 square feet of Grumman Sunstream Model 332 liquid flat plate collectors and the outside piping drain whenever the collector plates approach freezing or when power is interrupted. Solar heated water from the two above ground cement lined steel tanks (1000 gallon tank) is drawn into the electric Domestic Hot Water (DHW) tanks as hot water is drawn. Electric resistance units in the DHW tanks top off the solar heated water, if needed, to reach thermostat setting.

Source record↗

Solar heating and hot water system installed at Arlington Raquetball Club, Arlington, Virginia

A solar space and water heating system is described. The solar energy system consists of 2,520 sq. ft. of flat plate solar collectors and a 4,000 gallon solar storage tank. The transfer medium in the forced closed loop is a nontoxic antifreeze solution (50 percent water, 50 percent propylene glycol). The service hot water system consists of a preheat coil (60 ft. of 1 1/4 in copper tubing) located in the upper third of the solar storage tank and a recirculation loop between the preheat coil and the existing electric water heaters. The space heating system consists of two separate water to air heat exchangers located in the ducts of the existing space heating/cooling systems. The heating water is supplied from the solar storage tank. Extracts from site files, specification references for solar modifications to existing building heating and hot water systems, and installation, operation and maintenance instructions are included.

Source record↗

AI Automated Discovery of New Climate Water System Knowledge from Models and Observations

This paper addresses focus area 3, “Insight gleaned from complex data.” Science Challenge: The climate-water system is highly complex, containing a multitude of positive and negative feedbacks, time scales stretching many orders-of-magnitudes, and non-linear, connected processes. Powerful artificial intelligence (AI) methods can revolutionize and automate the discovery of new knowledge and relationships in the climate-water system, which will improve understanding and predictability of extreme hydrological events.

54 ENVIRONMENTAL SCIENCES↗

Prototype solar heating and hot water systems

Alternative approaches to solar heating and hot water system configurations were studied, parametrizing the number and location of the dampers, the number and location of the fans, the interface locations with the furnace, the size and type of subsystems, and operating modes. A two-pass air-heating collector was selected based on efficiency and ease of installation. Also, an energy transport module was designed to compactly contain all the mechanical and electrical control components. System performance calculations were carried out over a heating season for the tentative site location at Tunkhnana, Pa. Results illustrate the effect of collector size, storage capacity, and use of a reflector. Factors which affected system performance include site location, insulative quality of the house, and of the system components. A preliminary system performance specification is given.

Source record↗

Thermal performance of a photographic laboratory process: Solar Hot Water System

The thermal performance of a solar process hot water system is described. The system was designed to supply 22,000 liters (5,500 gallons) per day of 66 C (150 F) process water for photographic processing. The 328 sq m (3,528 sq. ft.) solar field has supplied 58% of the thermal energy for the system. Techniques used for analyzing various thermal values are given. Load and performance factors and the resulting solar contribution are discussed.

Walker, J. A.↗

Exploring Water System Vulnerabilities in California's Central Valley Under the Late Renaissance Megadrought and Climate Change

Abstract California faces cycles of drought and flooding that are projected to intensify, but these extremes may impact water users across the state differently due to the region's natural hydroclimate variability and complex institutional framework governing water deliveries. To assess these risks, this study introduces a novel exploratory modeling framework informed by paleo and climate‐change based scenarios to better understand how impacts propagate through the Central Valley's complex water system. A stochastic weather generator, conditioned on tree‐ring data, produces a large ensemble of daily weather sequences conditioned on drought and flood conditions under the Late Renaissance Megadrought period (1550–1580 CE). Regional climate changes are applied to this weather data and drive hydrologic projections for the Sacramento, San Joaquin, and Tulare Basins. The resulting streamflow ensembles are used in an exploratory stress test using the California Food‐Energy‐Water System model, a highly resolved, daily model of water storage and conveyance throughout California's Central Valley. Results show that megadrought conditions lead to unprecedented reductions in inflows and storage at major California reservoirs. Both junior and senior water rights holders experience multi‐year periods of curtailed water deliveries and complete drawdowns of groundwater assets. When megadrought dynamics are combined with climate change, risks for unprecedented depletion of reservoir storage and sustained curtailment of water deliveries across multiple years increase. Asymmetries in risk emerge depending on water source, rights, and access to groundwater banks.

Gupta, Rohini S. [School of Civil and Environmenta↗

Overall chilled water system energy consumption modeling and optimization

The emergence of increasingly affordable variable-speed drive technology has changed the approach used to control chilled water systems equipped with these drives. The purpose of this research was to develop an integrated chilled water modeling technique that can determine the optimal system setpoints and estimate the energy saving potential of chiller system. The chiller system equipped with Variable Frequency Drives (VFDs) on cooling tower fans and condenser water pumps. To accomplish the objective, physical component models of the centrifugal chiller, cooling tower and condenser water pump were established with the goal of incorporating the system’s condenser water flow rate and cooling tower fan speeds as optimization variables. Furthermore, a cooling load prediction algorithm was developed using a multiple non-linear regression model to approximate the building’s cooling load subject to a range of environmental conditions. The inputs and outputs of the individual component models were linked to estimate how adjusting the cooling tower fan and condenser water pump speed would influence the system’s comprehensive performance. Here, the overall system model was then optimized using a generalized reduced gradient optimization algorithm to determine the potential energy savings through speed control with VFDs and to ascertain a control logic strategy for the building automation system to operate the heating and cooling system. A case-study was performed on a single chiller system at a museum and the model was calibrated according to logged data collected over four months. Results showed that for the system analyzed, the energy saving of optimizing the cooling tower fan system was found to be 12–15%, while the energy saving potential of optimizing the condenser water pump with the cooling tower fan was negligible. Additionally, comparing different cooling tower fan control strategies showed that a wet-bulb approach-based cooling tower control strategy was shown to have the highest correlation to the optimized fan speed with an R 2 of 0.924.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar hot water system installed at Las Vegas, Nevada

A solar energy hot water system installed in a motor inn at Las Vegas, Nevada is described. The inn is a three story building with a flat roof for installation of the solar panels. The system consists of 1,200 square feet of liquid flat plate collectors, a 2,500 gallon insulated vertical steel storage tank, two heat exchangers, and pumps and controls. The system was designed to supply approximately 74 percent of the total hot water load.

Source record↗