Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Heat Pump Water Heater Guide for Small Businesses

This guide is intended for building owners and facility managers interested in electrifying commercial building water heating systems via new building systems or system retrofits. This guide is also a resource for contractors becoming familiar with commercial heat pump water heaters (HPWHs). This guide focuses on integrated air-source HPWH equipment, and background information, best practices, and key considerations are included here. A building owner or facility manager should review project considerations with an engineer or contractor.

decarbonization↗

Field Performance of R-1234yf Heat Pump Water Heaters

Heat pump water heaters (HPWH) provide a resource for increasing water heating efficiency in U.S. residences. Electric HPWHs have traditionally utilized R-134a as the refrigerant in the vapor-compression cycle; however, this refrigerant is undesirable long-term due to its high global warming potential. For HPWHs, low global warming potential refrigerants such as R-1234yf may offer comparable performance, but the evaluation of these systems has been limited to laboratory settings. This study provides field evaluations of off-the-shelf HPWHs that had their factory R-134a refrigerant replaced with an optimized charge of R-1234yf. The field evaluation consisted of R-1234yf HPWHs at two occupied field sites and two unoccupied, simulated lab homes. At the two residential field sites with occupants, the R-1234yf HPWHs operated issue-free for the 18-month field trial, and the home occupants perceived no change in HPWH performance relative to their prior R-134a HPWHs. At the lab homes, under simulated hot water draws, the average daily operating efficiency of the R-1234yf HPWH was within 2% of the baseline R-134a HPWHs.

42 ENGINEERING↗

Global Heat Uptake by Inland Waters

Heat uptake is a key variable for understanding the Earth system response to greenhouse gas forcing. Despite the importance of this heat budget, heat uptake by inland waters has so far not been quantified. Here we use a unique combination of global-scale lake models, global hydrological models and Earth system models to quantify global heat uptake by natural lakes, reservoirs and rivers. The total net heat uptake by inland waters amounts to 2.6+/-3.2x10 20 J over the period 1900-2020, corresponding to 3.6% of the energy stored on land. The overall uptake is dominated by natural lakes (111.7%), followed by reservoir warming (2.3%). Rivers contribute negatively (-14%) due to a decreasing water volume. The thermal energy of water trapped on land due to reservoir construction exceeds inland water heat uptake by a factor ~10.4. This first quantification underlines that the heat uptake by inland waters is small, but not negligible.

58 GEOSCIENCES↗

Thermodynamic analysis of a two-stage binary-fluid ejector heat pump water heater

Ejector heat pump water heaters (EHPWHs) could significantly increase the thermal efficiency of domestic water heating and reduce greenhouse gas emissions. This study addresses two major technical barriers to using EHPWHs in domestic water heating—low heating cycle coefficient of performance (COP) and low condensation temperatures—using binary fluid pairs as a working fluid in a two-stage ejector system. A comprehensive, geometry-free model of binary-fluid ejectors was built and validated to predict the entrainment ratios of binary-fluid ejectors. A thermodynamic model of a two-stage binary-fluid ejector EHPWH was built to predict the heating cycle COP of EHPWHs. The performance of the EHPWH was theoretically evaluated using HFE7000 and Novec649 as primary fluids and R600 and R1234ze(Z) as secondary fluids. HFE7000/R600 gave the highest heating cycle COP (i.e., 1.356) in producing domestic hot water at 60.0 °C. An optimum evaporation temperature of the primary fluid was identified for the maximum effective entrainment ratio and effective pressure lift ratio of two-stage ejectors. Here, the effective entrainment ratio of the two-stage ejector dominated the heating cycle COP of the EHPWH. Primary fluids with lower latent heats of evaporation and/or secondary fluids with higher latent heats of evaporation yielded higher heating cycle COPs of EHPWHs.

42 ENGINEERING↗

Peak Reduction Using Mode Adjustment of Heat Pump Water Heaters in a Residential Neighborhood

Building electrification is putting pressure on distribution grid worldwide. Peak reduction is an important concern that can help reduce the growing stress and allow to defer investments in new capacity. Water heaters represent a convenient way of reducing peak because they are less dependent on weather, and their storage volume allows for asynchronous water heating and hot water use. Previous empirical studies investigated the ability of water heaters to reduce peak through the adjustment of the temperature setpoint. However, not all equipment vendors offer this option. This study aims at understanding the feasibility of peak reduction with an alternative configuration available in the market - by adjusting the device mode rather than temperature setpoint. The peak reduction methodology is tested in an occupied 46-townhome neighborhood located in Atlanta, GA. We find that peak shifting is possible with the adjustable mode approach, with the change in the peak load by 30-60%.

demand response↗

Decarbonization Technology Snapshot: Heat Pump Water Heaters

Heat pump water heaters use electricity to move heat from one place to another instead of generating heat directly. In many cases they replace gas-fired water heaters and are significantly more energy efficient, reducing on-site Scope 1 emissions and often resulting in reduced total emissions.

building decarbonization↗

Development and field demonstration of residential air source integrated heat pump using a three-stage compressor

To promote decarbonization and all electrification at residential sectors, it is necessary to use air source heat pumps (ASHPs) to replace natural gas for space heating and water heating. ASHPs are widely utilized for residential space cooling, heating, and water heating due to their simplicity and cost-effectiveness. However, their performance can be compromised in cold climates, where they may experience reduced heating capacity. A multi-functional heat pump, using a single compressor, to meet all home space conditioning and water heating demands, is an emerging technology. To address this limitation, we have developed and demonstrated an air source integrated heat pump to fulfill comprehensive home comfort requirements. This system employs a three-stage compressor and a single set of heat exchangers and valves, optimizing functionality while minimizing costs. The performance of the developed system was rigorously evaluated in both laboratory and field settings. In laboratory conditions, the system achieved a Seasonal Energy Efficiency Ratio of 17.0 (average COP of 4.98) and a Heating Seasonal Performance Factor of 11.0 (3.22). Additionally, in its most efficient operational mode—combining space cooling and water heating—the unit attained a total energy efficiency exceeding 7.0 seasonal COP in the field and could heat a 189-liter tank of water in just 25 min. The field study corroborated the laboratory findings, validating the system’s performance in real-world conditions. Here, this integrated heat pump represents an ideal solution for decarbonizing homes in northern climates by providing efficient space heating and water heating, thereby replacing the need for natural gas.

Integrated heat pump↗

Performance Evaluation of Low-Cost Condensers Immersed in the Water Tank of a Heat Pump Water Heater

This paper reports the effect of low-cost immersed condensers on the performance of a heat pump water heater (HPWH) that does not require a water-circulating pump. The proposed design is based on the immersion of an L-style condenser coil through an opening in the top of the water tank. The novel design aims to eliminate the need for the water-circulating pumps, thereby substantially improving efficiency and reducing costs and maintenance of the HPWH system. Comprehensive computational fluid dynamics (CFD) simulations and experimental tests were performed, and the results showed that the CFD simulations were close to the experimental data. Further results confirm that the L-style condenser can introduce buoyancy-driven flow and eliminate temperature stratification in the studied HPWH water tank, thereby improving the heat transfer coefficient and coefficient of performance of the HPWH. The testing results further showed that the L-style condenser enabled more than 53% higher coefficient of performance and 400% higher heat transfer coefficient compared with the straight vertical condenser, and achieved much faster water heating. Furthermore, the effects of immersed condensers with different circuits on the HPWH performance were evaluated and compared. All results indicate that the current energy-saving and inexpensive HPWH technology is technically valid, and the benefits of performance improvement and low cost are attractive in future HPWH design.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Construction and testing of ceramic fabric heat pipe with water working fluid

A prototype ceramic fabric/titanium water heat pipe has been constructed and tested; it transported 25 to 80 W of power at 423 K. Component development and testing is continuing with the aim of providing an improved prototype, with a 38 micron stainless steel liner covered by a biaxially-braided Nextel (trademark) sleeve that is approximately 300 microns thick. This fabric has been tested to 800 K, and its emittance is about 0.5 at that temperature. Advanced versions of the water heat pipe will probably require a coating over the ceramic fabric in order to increase this emittance to the 0.8 to 0.9 range.

Antoniak, Zenen I.↗

Cold Climate Integrated Heat Pump

This paper introduces development of a residential air-source integrated heat pump for cold climates (CCIHP). The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating and energy storage. The CCIHP is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance in heat pumps, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency of 35.0 EER and required only 25 minutes to heat a 50-gallon tank of water. The CCIHP can heat 1.7 GPM water from 58 to 125°F in a direct flow-through, when the ambient temperature is above 47°F. In a dedicated water heating mode using outdoor air source, the heat pump operated down to 17°F, achieving a COP > 2.6, and heated 50-gallon water within 1 hour.

Shen, Bo↗

Making Small-Volume Heat Pump Water Heaters Larger: A Design Framework for Integrated Phase Change Material Heat Exchangers

Those that use electricity for water heating, the majority use resistive elements rather than heat pump water heaters (HPWHs), the latter of which use 60-70% less energy than the former. One major barrier to wider HPWH adoption is the added equipment required, which prevents current 50-80-gallon tanks on the market from fitting into smaller utility closets sized for 30-40 gallons, such as those found in manufactured housing. Additionally, these smaller HPWHs tend to underperform relative to their larger counterparts. One solution that addresses both space and performance concerns is thermal energy storage, and in particular, phase change materials (PCMs). PCMs have been studied extensively in building envelope and HVAC systems, but remain a nascent technology in residential water heating. While water itself has a uniquely high energy storage capacity, PCMs have an even higher energy storage density, thus providing the potential to elevate the performance of 40-gallon HPWHs to that of 50-gallon or larger tanks. This research is part of a larger project that seeks to utilize thermal energy storage to enable decarbonized water heating in low-income communities. In this study, we outline the design process used to produce novel PCM heat exchangers for use in small-volume HPWH tanks, including the identification of design constraints and performance targets relevant to real-world applications. In order to ensure optimal PCM utilization and tank storage capacity, we focus here on co-maximizing surface area and PCM volume in the heat exchangers; therefore, this research targets triply periodic minimal surface (TPMS) lattices. TPMS lattices boast enhanced heat transfer capabilities compared to traditional heat exchanger geometries and offer highly tailorable designs; thus, they pair well with the growing field of additive manufacturing, or 3D printing. Starting with a suite of TPMS lattices, we demonstrate a systematic approach for narrowing down feasible designs that comply with identified constraints while meeting PCM performance objectives.

25 ENERGY STORAGE↗

Residential Integrated Heat Pump to Meet All the Home Comfort Needs

This paper will introduce development and field trial of a residential air-source integrated heat pump for cold climates. The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating. The integrated heat pump is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency > 30.0 EER and required only 25 minutes to heat a 50-gallon tank of water. One heat pump prototype is going through a field trial since April, 2023 in Syracuse, New York. The one-year field test results are summarized.

Shen, Bo↗

Solar heating and hot water system installed at Arlington Raquetball Club, Arlington, Virginia

A solar space and water heating system is described. The solar energy system consists of 2,520 sq. ft. of flat plate solar collectors and a 4,000 gallon solar storage tank. The transfer medium in the forced closed loop is a nontoxic antifreeze solution (50 percent water, 50 percent propylene glycol). The service hot water system consists of a preheat coil (60 ft. of 1 1/4 in copper tubing) located in the upper third of the solar storage tank and a recirculation loop between the preheat coil and the existing electric water heaters. The space heating system consists of two separate water to air heat exchangers located in the ducts of the existing space heating/cooling systems. The heating water is supplied from the solar storage tank. Extracts from site files, specification references for solar modifications to existing building heating and hot water systems, and installation, operation and maintenance instructions are included.

Source record↗

Heat transfer in water under laser heating through fibres for endovenous laser coagulation

We report the results of studying heat transfer in water heated by a cw laser with wavelengths of 1.55 and 1.94 μm through optical fibres with end-face and radial outputs. It is shown that, depending on the power and wavelength of the radiation, heat transfer is implemented via convection, bubble boiling, or explosive boiling and occurs asymmetrically, mainly in the forward − upward direction for the fibre with the end-face output and upward for the radial output. (laser medicine)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dirty dishes or dirty laundry? Comparing two methods for quantifying American consumers' preferences for load management in a smart home

One challenge of transitioning to renewable energy is that household electricity use and renewable generation are often misaligned. Smart home energy management systems hold promise for shifting usage to match generation, but these systems need to be designed with the occupants’ preferences in mind. The purpose of the present research is to compare two approaches for collecting and modeling consumers’ load management preferences, both of which are amenable to use in a home energy management system. Specifically, we examine the performance of Simple Multi-Attribute Rating Technique Exploiting Ranks (SMARTER) and Analytic Hierarchy Process (AHP) in quantifying consumers’ preferences regarding air temperature (air conditioning and heating), water heating, dishwashing, clothes washing and drying, monetary costs, environmental impacts, and comfort/convenience. Two studies are presented: Study 1 examines the SMARTER approach, and Study 2 focuses on the AHP approach. In both studies, online surveys (N SMARTER = 956 and N AHP = 1023) were conducted to elicit preferences from participants across the United States. The preferences modeled by both approaches were validated based on (a) their ability to predict participants’ choices in a Discrete Choice Experiment and (b) their convergence with previous research on load-shifting behavior. The validation procedure suggests that the SMARTER approach is superior in modeling consumers’ preferences for load management. Overall, this research lays the groundwork for designing a smart home interface capable of collecting occupants’ preferences and using those preferences to deliver improved occupant comfort, lower operating costs, reduced environmental impact, and more significant demand response than exists today.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗