Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water distribution system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Water Microgrids: A Primer for Facility Managers

A water microgrid is similar in concept to an energy microgrid, which the U.S. Department of Energy defines as “a local energy grid with control capability, which means it can disconnect from the traditional grid and operate autonomously.” Similarly, a water microgrid is a local water system that supplies, treats, and distributes water, with the primary objective to meet mission critical water demands during a disruption of the primary supply. A water microgrid has the capability to operate independently of an existing primary water system and includes a layer of sensing capability that provides the necessary monitoring and controls to operate the water microgrid. A water microgrid may offer a viable solution for a site to address resilience gaps identified through the resilience planning process. For example, a site may not have adequate and redundant water supply to meet mission critical demands with vulnerabilities in the operating systems. A water microgrid provides the ability to island the water system from the primary water supply to satisfy water demand requirements throughout an outage or disruption.

42 ENGINEERING↗

Continuous monitoring of bacterial attachment

A major concern with the Space Station Freedom (SSF) water supply system is the control of longterm microbial contamination and biofilm development in the water storage and distribution systems. These biofilms have the potential for harboring pathogens as well as microbial strains containing resistance factors that could negatively influence crew health. The proposed means for disinfecting the water system on SSF (iodine) may encourage the selection of resistant strains. In fact, biofilm bacteria were observed in water lines from the Space Shuttle Columbia (OV-102); therefore, an alternative remediation method is required to disinfect spacecraft water lines. A thorough understanding of colonization events and the physiological parameters that will influence bacteria adhesion is required. The limiting factor for development of this technology is the ability to continuously monitor adhesion events and the effects of biocides on sessile bacteria. Methods were developed to allow bacterial adhesion and subsequent biocidal treatment to be monitored continuously. This technique couples automated image analysis with a continuous flow of a bacterial suspension through an optical flow cell. A strain of Pseudomonas cepacia isolated from the water supply of the Space Shuttle Discovery (OV-103) during STS-39 was grown in a nitrogen-limited continuous culture. This culture was challenged continuously with iodine during growth, and the adhesion characteristics of this strain was measure with regard to flow rate. Various biocides (ozone, hypochlorite, and iodine) were added to the flow stream to evaluate how well each chemical removed the bacteria. After biocide treatment, a fresh bacterial suspension was introduced into the flow cell, and the attachment rate was evaluated on the previously treated surface. This secondary fouling was again treated with biocide to determine the efficacy of multiple batch chemical treatments in removing biofilm.

Koeing, D. W.↗

Colorimetric Solid Phase Extraction (CSPE): Using Color to Monitor Spacecraft Water Quality

In August 2009, an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE) technology was delivered to the International Space Station (ISS). The kit, called the Colorimetric Water Quality Monitoring Kit (CWQMK), was launched as a Station Development Test Objective (SDTO) experiment to evaluate the suitability of CSPE technology for routine use monitoring water quality on the ISS. CSPE is a sorption-spectrophotometric technique that combines colorimetric reagents, solid-phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water samples. In CSPE, a known volume of sample is metered through a membrane disk that has been impregnated with an analyte-specific colorimetric reagent and any additives required to optimize the formation of the analyte-reagent complex. As the sample flows through the membrane disk, the target analyte is selectively extracted, concentrated, and complexed. Formation of the analyte-reagent complex causes a detectable change in the color of the membrane disk that is proportional to the amount of analyte present in the sample. The analyte is then quantified by measuring the color of the membrane disk surface using a hand-held diffuse reflectance spectrophotometer (DRS). The CWQMK provides the capability to measure the ionic silver (Ag +) and molecular iodine (I2) in water samples on-orbit. These analytes were selected for the evaluation of CSPE technology because they are the biocides used in the potable water storage and distribution systems on the ISS. Biocides are added to the potable water systems on spacecraft to inhibit microbial growth. On the United States (US) segment of the ISS molecular iodine serves as the biocide, while the Russian space agency utilizes silver as a biocide in their systems. In both cases, the biocides must be maintained at a level sufficient to control bacterial growth, but low enough to avoid any negative effects on crew health. For example, the presence of high levels of iodine in water can cause taste and odor issues that result in decreased water consumption by the crew. There are also concerns about potential impacts on thyroid function following exposure to high levels of iodine. With silver, there is a risk of developing argyria, an irreversible blue-gray discoloration of the skin, associated with long term consumption of water containing high concentrations of silver. The need to ensure that safe, effective levels of biocide are maintained in the potable water systems on the ISS provides a perfect platform for evaluating the suitability of CSPE technology for in-flight water quality monitoring. This paper provides an overview of CSPE technology and details on the silver and iodine methods used in the CWQMK. It also reports results obtained during in-flight analyses performed with the CWQMK and briefly discusses other potential applications for CSPE technology in both the spacecraft and terrestrial environments.

Gazda, Daniel B.↗

Investigation of Silver Biocide as a Disinfection Technology for Spacecraft-An Early Literature Review

An ideal spacecraft water disinfection system should prevent or control microbial growth, inhibit or prevent biofilm formation, and prevent microbial-induced corrosion. In addition, the selected biocide system should be chemically compatible with materials used in the water storage and distribution system, have minimal maintenance requirements, especially for long-duration missions, and should be safe for crew consumption at levels appropriate for biocidal control. Silver ion is a proven broad spectrum biocide. There has been an increased interest in the biocidal function of silver, both due to its potential to control biocide resistant species and due to advances in silver and nanosilver biocide technologies. NASA is considering silver as the future biocide for exploration over the iodine biocide system. In order to select and design a successful silver biocide delivery system to meet NASA's requirements, it is essential to understand the advantages and disadvantages of moving to a silver disinfection system. To enhance the knowledge base for the application of silver biocides in spacecraft water systems, this paper provides a first compilation of review data related to: (1) Silver as a biocide technology, (2) Options and concepts for silver biocide delivery, and (3) Silver biocide compatibility studies for spacecraft systems.

Li, Wenyan↗

Development and Evaluation of Distributed Energy Resource Device Models: Electric Vehicles, Electric Water Heaters, and Commercial Refrigeration Systems

In order to validate distributed energy resource (DER) models operated with grid services in the GMLC 1.4.2 team’s February (GMLC 2019a) and July (GMLC 2019b) reports, a test and measurement program using actual DER devices was conducted by national laboratories for three devices: (1) electric vehicles (EVs), (2) water heaters, and (3) commercial refrigeration. Test procedures were developed and carried out to identify the mathematical models and their parameters that describe the operational function, characterize the physics, and obey transient response of the devices. This report focuses on the experimental results obtained to develop and verify simulations of three specific EV models. This section summarizes elements of the mathematical model and shows the necessity data collected from the EVs while charging and discharging (driving). In the course of the study, we found it necessary to make some modifications to the model to deal with observed transient behavior. Section 1.2 details the model assumptions and equations, Section 1.3 provides details of the EVs tested, Section 1.4 outlines the test procedures developed for the projects, and Section 1.5 presents the experimental results obtained for the three different EVs tested and how these results compare to the models running the same test profiles.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Iodine and Silver as Biocides for Potable Water in Human Missions beyond Low Earth Orbit

Chemical biocides play an important role in potable water storage and distribution systems. They provide protection against microbial growth that can negatively impact efficient water transport and crew health. Molecular iodine and ionic silver have been used on the International Space Station for decades. Future orbiting and surface habitats will have potable water systems that will require reliable potable water storage and challenging transport schemes during daily operations with potentially lengthy and repeated periods of non-use. Based on a review of literature, experimental data, and flight data this paper categorizes the advantages and disadvantages of the two heritage biocides on ISS: iodine and silver. The history of biocide practices on ISS is compared to requirements of future human missions beyond low Earth Orbit. The upstream water quality supply and downstream water uses are defined with respect to the two biocides. The methods of injection and removal of the two biocides are compared for a range of downstream water uses including drinking water, hygiene water, technical water, oxygen generation water, and extravehicular activity water. The paper provides mission planners with a technical and engineering assessment of the two biocides and identifies gaps in knowledge and on-orbit experiences.

Dean Muirhead↗

Emerging Technologies Review: Water Microgrid

Project 69643 Task 10 - The Air Force Civil Engineer Center has tasked Pacific Northwest National Laboratory with investigating emerging technologies to inform the Air Force’s understanding of the technology and to guide key considerations for implementing technologies that are resilient and alternative sources to the traditional methods used in the Air Force today. This report explores the concept of a water microgrid for deployment at Air Force installations. A water microgrid is a local water system that supplies, treats, and distributes water, with the primary objective to meet mission critical water demand during a disruption of the primary supply. A water microgrid can advance an Air Force installation’s water infrastructure and water resilience by being at the ready for meeting critical missions during a utility outage.

42 ENGINEERING↗

Ice Cloud Properties in Ice-Over-Water Cloud Systems Using TRMM VIRS and TMI Data

A multi-layered cloud retrieval system (MCRS) is updated and used to estimate ice water path in maritime ice-over-water clouds using Visible and Infrared Scanner (VIRS) and TRMM Microwave Imager (TMI) measurements from the Tropical Rainfall Measuring Mission spacecraft between January and August 1998. Lookup tables of top-of-atmosphere 0.65- m reflectance are developed for ice-over-water cloud systems using radiative transfer calculations with various combinations of ice-over-water cloud layers. The liquid and ice water paths, LWP and IWP, respectively, are determined with the MCRS using these lookup tables with a combination of microwave (MW), visible (VIS), and infrared (IR) data. LWP, determined directly from the TMI MW data, is used to define the lower-level cloud properties to select the proper lookup table. The properties of the upper-level ice clouds, such as optical depth and effective size, are then derived using the Visible Infrared Solar-infrared Split-window Technique (VISST), which matches the VIRS IR, 3.9- m, and VIS data to the multilayer-cloud lookup table reflectances and a set of emittance parameterizations. Initial comparisons with surface-based radar retrievals suggest that this enhanced MCRS can significantly improve the accuracy and decrease the IWP in overlapped clouds by 42% and 13% compared to using the single-layer VISST and an earlier simplified MW-VIS-IR (MVI) differencing method, respectively, for ice-over-water cloud systems. The tropical distribution of ice-over-water clouds is the same as derived earlier from combined TMI and VIRS data, but the new values of IWP and optical depth are slightly larger than the older MVI values, and exceed those of single-layered layered clouds by 7% and 11%, respectively. The mean IWP from the MCRS is 8-14% greater than that retrieved from radar retrievals of overlapped clouds over two surface sites and the standard deviations of the differences are similar to those for single-layered clouds. Examples of a method for applying the MCRS over land without microwave data yield similar differences with the surface retrievals. By combining the MCRS with other techniques that focus primarily on optically thin cirrus over low water clouds, it will be possible to more fully assess the IWP in all conditions over ocean except for precipitating systems.

Minnis, Patrick↗

Iodine susceptibility of pseudomonads grown attached to stainless steel surfaces

Pseudomonads were adapted to grow in phosphate-buffered water and on stainless steel surfaces to study the iodine sensitivity of attached and planktonic cells. Cultures adapted to low nutrient growth were incubated at room temperature in a circulating reactor system with stainless steel coupons to allow biofilm formation on the metal surfaces. In some experiments, the reactor was partially emptied and refilled with buffer at each sampling time to simulate a "fill-and-draw" water system. Biofilms of attached bacteria, resuspended biofilm bacteria, and reactor suspension, were exposed to 1 mg l-1 iodine for 2 min. Attached bacterial populations which established on coupons within 3 to 5 days displayed a significant increase in resistance to iodine. Increased resistance was also observed for resuspended cells from the biofilm and planktonic bacteria in the system suspension. Generally, intact biofilms and resuspended biofilm cells were most resistant, followed by planktonic bacteria and phosphate buffer cultures. Thus, biofilm formation on stainless steel surfaces within water systems can result in significantly increased disinfection resistance of commonly-occurring water-borne bacteria that may enhance their ability to colonise water treatment and distribution systems.

NASA Program Environmental Health↗

Mitigation of Biofouling in Plant Watering Systems Using AgXX, a Novel Surface Treatment

The development of plant growth systems with high yields and low maintenance for food production is a key focus area for NASA. One of the remaining technical challenges is keeping the plant watering systems clean without affecting plant growth, requiring consumables, or demanding crew time. Plant watering systems, such as the one onboard the International Space Station (ISS), provide a nutrient rich environment for biofilm formation. Frequent maintenance is necessary to prevent biofouling, which currently requires crew time and a mechanical means of cleaning. Better solutions are needed. The current ISS practices for biofilm mitigation in the water recovery and distribution system include the use of biocides (silver ion or iodine) along with regular maintenance (e.g. flushing, filter replacement). These biocide-based strategies could be problematic for plant watering systems, such as in Ohalo, the Exploration Garden, and the APH, due to incompatibilities of the biocides with plants. We propose the application of AgXX, a novel antifouling surface treatment that meets the above requirements. This paper will report on an initial study that was completed to determine whether AgXX would be effective in a plant nutrient solution, and whether it would negatively impact plant growth in a hydroponics-type system.

Tesia D. Irwin↗

Numerical simulation of iodine speciation in relation to water disinfection aboard manned spacecraft I. Equilibria

Elemental iodine (I2) is currently used as the drinking water disinfectant aboard the Shuttle Orbiter and will also be incorporated into the water recovery and distribution system for the International Space Station Alpha. Controlled release of I2 is achieved using the Microbial Check Valve (MCV), a flow-through device containing an iodinated polymer which imparts a bacteriostatic residual concentration of approximately 2mg/L to the aqueous stream. During regeneration of MCV canisters, I2 concentrations of approximately 300 mg/L are used. Dissolved iodine undergoes a series of hydrolytic disproportionation and related reactions which result in the formation of an array of inorganic species including: I-, I3-, HOI, OI-, IO3-, HIO3, I2OH-, I2O(-2), and H2OI+. Numerical estimation of the steady-state distribution of inorganic iodine containing species in pure water at 25 degrees C has been achieved by simultaneous solution of the multiple equilibrium expressions as a function of pH. The results are reported herein.

NASA Discipline Environmental Health↗

U.S. Industrial and Commercial Motor System Market Assessment Report. Volume 3: Energy Saving Opportunity

This report seeks to inform the potential for motor systems to support decarbonization by estimating their potential energy, electricity cost, and CO 2 emissions reduction potential from adoption of proven energy efficiency actions and advanced technologies. This is the third and final report in a series of reports disseminating the findings of the U.S. Department of Energy’s (DOE’s) Motor System Market Assessment (MSMA). The MSMA and this report focus on polyphase motor systems greater than or equal to 1 horsepower (hp) in the industrial and commercial sectors. In the U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base (Volume 1 report), it was determined that these motor systems consume more than 1,000 terawatt-hours (TWh) annually. This equates to 29% of the U.S. electric grid load and results in 765 million metric tons (MMT) of CO 2 emissions and $166 billion in electricity costs. This report finds that substantial reductions to these energy, cost, and emissions impacts are possible, with three areas of significant opportunity being (1) improved load matching, (2) replacing older inefficient motors with more efficient motors, and (3) improving the condition of fluid (e.g., air, water, compressed air) distribution systems. A summary of the savings potential from these three opportunities placed within the context of the overall consumption for motor systems is illustrated in Figure ES 1 (industrial) and Figure ES 2 (commercial).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Health significance and occurrence of injured bacteria in drinking water

Enteropathogenic and indicator bacteria become injured in drinking water with exposure to sublethal levels of various biological, chemical and physical factors. One manifestation of this injury is the inability to grow and form colonies on selective media containing surfactants. The resulting underestimation of indicator bacteria can lead to a false estimation of water potability. m-T7 medium was developed specifically for the recovery of injured coliforms (both "total" and fecal) in drinking water. The m-T7 method was used to survey operating drinking water treatment and distribution systems for the presence of injured coliforms that were undetected with currently used media. The mean recovery with m-Endo LES medium was less than 1/100 ml while it ranged between 6 and 68/100ml with m-T7 agar. The majority of samples giving positive results with m-T7 medium yielded no detectable coliforms with m-Endo LES agar. Over 95% of the coliform bacteria in these samples were injured. Laboratory experiments were also done to ascribe the virulence of injured waterborne pathogens. Enteropathogens including Salmonella typhimurium, Yersinia enterocolitica and Shigella spp. required up to 20 times the chlorine levels to produce the same injury in enterotoxigenic Escherichia coli (ETEC) and nonpathogenic coliforms. Similar results were seen with Y. enterocolitica exposed to copper. The recovery of ETEC was followed by delayed enterotoxin production, both in vitro and in the gut of experimental animals. This indicates that injured waterborne enteropathogenic bacteria can be virulent.

NASA Discipline Number 13-40↗

Energy Master Planning: Identifying Framing Constraints that Scope Your Technology Options

This paper addresses the framing constraints for building and community energy projects that must be considered when energy master planning (EMP) is conducted. The constraints cover emissions, sustainability, resilience, regulations and directives, and regional and local limitations such as available energy types, local conditions, and project requirements. The paper reflects development results from participants in an International Energy Agency project on energy master planning and in a U.S. Department of Defense project on technology integration to achieve resilient, low-energy use military installations. It identifies a comprehensive list of framing constraints categorized into locational threats, locational resources, energy and water distribution and storage systems, building and facility, indoor environmental, and equipment in buildings and district systems constraints. In addition, it identifies limits for these constraints that exist in seven participating countries. Some framing constraints can profoundly impact technology selection while others impact the installation of technologies (as in hardening) and have little to no impact on technology selection. Furthermore, framing constraints can be assessed in different ways and there are resources available to help EMP stakeholders evaluate them. Finally, a case is made that identifying and applying framing constraints early in EMP can bring efficiencies and better focus to the EMP process. We come to the conclusion that (1) for holistic energy planning, it is essential to identify and assess the framing constraints that bound an optimized EMP solution, (2) framing constraints limits should be evaluated as either hard or soft or promising technologies may fall out of an EMP analysis, (3) to maintain consistent quality in the EMP process, the identification of framing constraints and their limits, and perhaps their evaluation, should be standardized, (4) a standardized approach could establish a baseline that can be used, built upon, and improved, (5) as automated EMP tools are improved or developed, the resources in this paper could possibly contribute to their interworkings relative to technology screening, and (6) continued climate change and resulting aggressive goal setting will likely drive a continued and strong emphasis on EMP.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Microbial distribution in the Environmental Control and Life Support System water recovery test conducted at NASA, MSFC

NASA/MSFC is developing a physical/chemical treatment system to reclaim wastewater for reuse on Space Station Freedom (SSF). Integrated testing of hygiene and potable water subsystems assessed the capability to reclaim water to SSF specifications. The test was conducted from May through July 1990 with a total of 47 days of system test operation. Water samples were analyzed using standard cultural methods employing membrane filtration and spread plate techniques and epifluorescence microscopy. Fatty acid methyl ester and biochemical profiles were used for microbial identification. Analysis of waste and product water produced by the subsystems demonstrated the effective reduction of viable microbial populations greater than 8.0E + 06 colony forming units (CFU) per 100 mL to an average of 5 CFU/100 mL prior to distribution into storage tanks.

Gauthier, J. J.↗

Water-Vapor Raman Lidar System Reaches Higher Altitude

A Raman lidar system for measuring the vertical distribution of water vapor in the atmosphere is located at the Table Mountain Facility (TMF) in California. Raman lidar systems for obtaining vertical water-vapor profiles in the troposphere have been in use for some time. The TMF system incorporates a number of improvements over prior such systems that enable extension of the altitude range of measurements through the tropopause into the lower stratosphere. One major obstacle to extension of the altitude range is the fact that the mixing ratio of water vapor in the tropopause and the lower stratosphere is so low that Raman lidar measurements in this region are limited by noise. Therefore, the design of the TMF system incorporates several features intended to maximize the signal-to-noise ratio. These features include (1) the use of 355-nm-wavelength laser pulses having an energy (0.9 J per pulse) that is high relative to the laser-pulse energy levels of prior such systems, (2) a telescope having a large aperture (91 cm in diameter) and a narrow field of view (angular width .0.6 mrad), and (3) narrow-bandpass (wavelength bandwidth 0.6 nm) filters for the water-vapor Raman spectral channels. In addition to the large-aperture telescope, three telescopes having apertures 7.5 cm in diameter are used to collect returns from low altitudes.

Leblanc, Thierry↗

ReaxFF molecular dynamics simulations of electrolyte–water systems at supercritical temperature

We have performed ReaxFF molecular dynamics simulations of alkali metal–chlorine pairs in different water densities at supercritical temperature (700 K) to elucidate the structural and dynamical properties of the system. The radial distribution function and the angular distribution function explain the inter-ionic structural and orientational arrangements of atoms during the simulation. The coordination number of water molecules in the solvation shell of ions increases with an increase in the radius of ions. We find that the self-diffusion coefficient of metal ions increases with a decrease in density under supercritical conditions due to the formation of voids within the system. The hydrogen bond dynamics has been interpreted by the residence time distribution of various ions, which shows Li+ having the highest water retaining capability. The void distribution within the system has been analyzed by using the Voronoi polyhedra algorithm providing an estimation of void formation within the system at high temperatures. We observe the formation of salt clusters of Na+ and K+ at low densities due to the loss of dielectric constants of ions. The diffusion of ions gets altered dramatically due to the formation of voids and nucleation of ions in the system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗