Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Lattice and Local Electronic Structure Modulation Enables Ultra-Long-Life Li-Rich Cathode Materials

Effectively alleviating severe performance deterioration including rapid capacity decay and continuous voltage fading of Li-rich layered oxide (LLO) cathodes by suppressing the irreversible oxygen release and transition metal (TM) migration is a critical challenge during prolonged cycling. Herein, we report a Sb-doped LLO (SLLO) cathode with shortened TM oct –TM oct distance and modulated local electronic structure, which can significantly enhance the oxygen vacancy formation energy and TM migration energy barriers. Therefore, the SLLO cathode showcases an impressive energy density of 1052 Wh kg –1 at 0.2 C and an outstanding rate capability of 214 mAh g –1 at 5 C with a remarkable capacity retention of 79.2% even after 1000 cycles. It should be pointed out that it exhibits greatly enhanced voltage stability with an outstanding voltage retention of 86.2% after cycling 1600 times at 10 C. In conclusion, this work provides a prototype for significantly enhancing the reversibility in electrochemical reactions of high-capacity layered cathode materials.

25 ENERGY STORAGE↗

Electrolytes for Use in High Energy Lithium-Ion Batteries with Wide Operating Temperature Range

Objectives of this work are: (1) Develop advanced Li -ion electrolytes that enable cell operation over a wide temperature range (i.e., -30 to +60C). (2) Improve the high temperature stability and lifetime characteristics of wide operating temperature electrolytes. (3) Improve the high voltage stability of these candidate electrolytes systems to enable operation up to 5V with high specific energy cathode materials. (4) Define the performance limitations at low and high temperature extremes, as well as, life limiting processes. (5) Demonstrate the performance of advanced electrolytes in large capacity prototype cells.

voltage stability↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

A Polymer-in-Salt Electrolyte with Enhanced Oxidative Stability for Lithium Metal Polymer Batteries

Lithium (Li) metal polymer batteries (LMPBs) are a promising candidate of solid-state batteries with high safety. However, rare progress has been demonstrated so far in high voltage stability of polyethylene oxide (PEO) based polymer electrolytes for LMPBs. Herein, we revived the polymer-in-salt electrolyte (PISE) strategy based on the PEO-LiFSI system with EO/Li = 8 through a dry process to avoid the contamination of the residual solvent. The obtained PISEs exhibit quite different morphologies and coordination structures which greatly enhance the oxidative stability of polymer electrolytes. P(EO)1LiFSI has a low melting temperature, a high ionic conductivity at 60 ?C and an oxidative stability of ~4.5 V vs. Li/Li+ (overcoming the inherent low oxidative stability of PEO). With an effective interphase rich in inorganic species, in combination with good stability of the hybrid polymer electrolyte towards Li metal, the cycling stability of Li||LiNi1/3Co1/3Mn1/3O2 is greatly improved. The LMPB can retain 74.4% of capacity after 186 cycles at 60 ?C under the charge cutoff voltage of 4.3 V. The findings point out a promising strategy to develop high-voltage stable polymer electrolytes for high energy-density and safe LMPBs.

Polymer-in-salt electrolyte, lithium metal battery↗

Model predictive control for voltage restoration in microgrids using temporal logic specifications

Power system operation will encounter numerous voltage variabilities as the proliferation of renewable energy continues. Real-time monitoring and communication technologies can potentially improve voltage stability by enabling the rapid detection of voltage deviations and the implementation of corrective actions. These corrective actions will only be effective in restoring stability if they are chosen in a timely and scalable manner. This paper considers the problem of power systems’ load voltage control in order to simultaneously address both magnitude and time voltage specifications. In order to comply with grid codes and avoid unnecessary relay protection actions, a model predictive control (MPC)-based control strategy employing temporal logic specifications (TLSs) is proposed. The TLSs strategy is introduced as a formalism to control the voltage variation at a critical load bus against operational bounds over time. The control objective is to schedule optimal control input signals from the available supportive energy storage systems, which provide reactive power injections, leading to satisfying the specified finite-time restoration described by the TLSs with minimal control efforts. The simulation results display that the TLSs strategy for power systems’ voltage control synthesis is extremely significant.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Atomic layer deposited aluminum nitride for interface protection of lithium germanium thiophosphate solid electrolytes

Lithium germanium thiophosphate (LGPS) is an attractive solid-state electrolyte material due to its exceptionally high ionic conductivity (~1.2 × 10 –2 S cm –1 ), comparable to many organic liquid electrolytes commonly used in batteries. Despite the high conductivity of LGPS, the susceptibility of LGPS to deleterious degradation reactions has impeded its commercial adoption into solid-state batteries. In particular, the poor voltage stability of LGPS with high-voltage cathode or lithium metal potentials often results in dramatically increasing cell impedance during galvanic cycling. Here, we use aluminum nitride (AlN) as a protection layer for Li metal anode, applied directly to the LGPS at 250 °C using plasma-enhanced atomic layer deposition, to enhance cell performance by preventing LGPS-Li metal reactions. We compare the surface chemistry and electrochemical cycling performance of atomic layer-deposited AlN grown using both plasma N 2 and NH 3 precursors. Galvanostatic cycling and electrochemical impedance spectroscopy show that AlN-coated LGPS cells perform better than bare LGPS cells in contact with Li metal anodes, with the AlN able to improve cycling longevity by over a factor of 3 in certain cases. Finally, we utilize x-ray photoelectron spectroscopy (XPS) line scans to highlight the slow room-temperature reactivity between AlN and evaporated lithium metal, and a computational model is built to aid further XPS analysis.

25 ENERGY STORAGE↗

Interpretable Data-Driven Probabilistic Power System Load Margin Assessment with Uncertain Renewable Energy and Loads

The increasing uncertainties caused by the high-penetration of stochastic renewable generation resources poses a significant threat to the power system voltage stability. To address this issue, this paper proposes a probabilistic deep kernel learning enabled surrogate model to extract the hidden relationship between uncertain sources, i.e., wind power and loads, and load margin for probabilistic load margin assessment (PLMA). Unlike other deep learning approaches, a kernel SHAP provides the sensitivity analysis as well as interpretability of the inputs to outputs influences. This allows identifying the critical factors that affect load margin so that corrective control can be initiated for stability enhancement. Numerical results carried out on the IEEE 118-bus power system demonstrate the accuracy and efficiency of the proposed data-driven PLMA scheme.

deep kernel learning↗

Mitigating Voltage Instability in the Saudi Grid for a Decarbonized, Fully Solar Power System

Lately, solar photovoltaic (PV) has received significant interest due to its economic and environmental benefits. As the integration of renewable energy sources (RES) increases into existing power grids, challenges such as the decrease in short circuit ratio (SCR) are introduced. Here, this paper investigates a case study of the Saudi power grid, examining the voltage stability as the grid transitions from traditional power generation to 100% penetration of solar PV gradually. Moreover, the paper explores the relationship between the increase in solar penetration and the potential effects on the short circuit MVA (SCMVA), which could significantly impact the overall SCR of the system. To meet the North American Electric Reliability Corporation (NERC) recommendation of maintaining SCR at a particular level, synchronous condensers (SC)s were integrated into the grid. The effectiveness of utilizing SCs to maintain the system voltage at optimal levels in a fully solar grid is also considered. In addition, this paper covers the weak grid analysis via utilizing the Newton-Raphson load flow method, along with PV and QV curve analyses. The purpose behind that is to determine weak bus locations in need of voltage improvements, and to meet the amount of reactive power to be injected. Finally, the amount of power being delivered by SCs will be added progressively in three scenarios to show the enhancements on SCR more precisely.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Objective PMU Allocation for Resilient Power System Monitoring

Phasor measurement units (PMUs) enable better system monitoring and security enhancement in smart grids. In order to enhance power system resilience against outages and blackouts caused by extreme weather events or man-made attacks, it remains a major challenge to determine the optimal number and location of PMUs. In this paper, a multi-objective resilient PMU placement (MORPP) problem is formulated, and solved by a modified Teaching-Learning-Based optimization (MO-TLBO) algorithm. Three objectives are considered in the MORPP problem, minimizing the number of PMUs, maximizing the system observability, and minimizing the voltage stability index. The effectiveness of the proposed method is validated through testing on IEEE 14-bus, 30-bus, and 118-bus test systems. The advantage of the MO-TLBO-based MORPP is demonstrated through the comparison with other methods in the literature, in terms of iteration number, optimality and time of convergence.

Multi-Objective Optimization↗

Nonlinear Multiple Models Adaptive Secondary Voltage Control of Microgrids

This article proposes a model-free secondary voltage control (SVC) for microgrids (MG) using nonlinear multiple models adaptive control. Firstly, a linear robust adaptive controller is designed to guarantee the voltage stability in the bounded-input- bounded-output (BIBO) manner so as to meet the operation requirements of MGs. Secondly, a nonlinear adaptive controller is developed to improve the voltage tracking performance with the help of artificial neural networks (ANNs). A switching mechanism for coordinating such two controllers is designed to guarantee the closed-loop stability while achieving accurate voltage tracking. Here, by an online identification based on the input and output data of MGs, the proposed method does not resort to any apriori information of system model and primary control, thus exhibiting good robustness, ease of deployment and disturbance rejection.

17 WIND ENERGY↗

The internal reference source (IRS) for diffuse infrared background experiment (DIRBE)

A means is described for providing internal calibration for the detectors for DIRBE, which is the Diffuse Infrared Background Experiment (a part of the Cosmic Background Explorer). The internal reference source (IRS) that is used consists of four thermal graybody sources coupled to an integrating sphere. The relative insensitivity of the DIRBE bolometers and the linear temperature dependence of the Rayleigh-Jeans law made bolometer stimulation over five orders of magnitude difficult, so four different sources were used with emitting areas varying by a factor of 10 to the 8th. A low heat capacity design with the necessary stability appears to be thin nichrome films on a sapphire substrate. Voltage stability to 0.01 percent is required for those near infrared bands that required stimulation on the Wien portion of the blackbody curve.

Silverglate, P.↗

Sensor enabled data-driven predictive analytics for modeling and control with high penetration of DERs in distribution systems

The electric power grid is undergoing a tremendous transformation due to the increasing penetration of renewable energy resources beginning with wind and more recently with the distributed energy resources (DERs) such as solar and battery storage. DERs have dramatically changed the role of the distribution systems in the overall power grid, and they are expected to contribute a significant portion of power generation in the future. If current trends for DERs continue, system operation and control will need to change dramatically for improved grid reliability and resiliency. As renewable resources increase in penetration, new and challenging operational, planning, and design problems are expected to emerge. Some of the key challenges that arise in the planning and operation of the future grid are: 1) Quantifying the impact of high DER penetration in distribution systems on bulk grid behavior over multiple time scales. 2) Identifying whether a particular DER configuration/settings have a large impact on the overall grid behavior. These challenges can be addressed in an offline manner using detailed T&D grid models and they can also be addressed in an online manner using sensor measurements. In particular, the advancement and planned growth in sensor technology in power grid over various voltage levels provide us with a unique opportunity to tackle these challenges from a data analytic perspective without needing detailed T&D grid models. A few questions that naturally arise when addressing the challenges from DERs using sensor data are: 1) How can we use limited sensor measurements to monitor & control voltage stability and small signal stability of the bulk system? 2) How can we ensure that the developed data analytic methods are robust to data availability and quality issues? 3) How can we compute the developed analytics in a scalable manner using streaming measurements? In this project, we addressed the aforementioned challenges arising from DERs and answered the questions raised above on how to effectively use the sensor measurements to enhance the reliability and performance of the electric grid. Thus, the overarching goal of this project is to develop effective reduced/representative system models from data that make the computational complexity sufficiently manageable so as to be useful to simulate, analyze, and even control complex non-linear power systems dynamics with large penetrations of DERs. In order to achieve the objective, the project team established a four-fold technical approach 1) Formulated a combined transmission-distribution co-simulation framework for data generation and validation, 2) Derived reduced/representative models of power systems based on data-driven methods for efficient computation and appropriate representation of system behavior, 3) Developed data driven characterization of power system behavior based on transfer operator theory, machine learning and optimization for model estimation, 4) Incorporated a scalable data management and processing architecture using distributed Kafka streaming applications that coordinate input data streams to the developed data analytics. The key accomplishments of the project are: 1) Development of a scalable multi-timescale T&D co-simulation framework (both for steady state and for dynamic co-simulation) using commercial solvers (PSSE and GridLAB-D). The steady-state T&D co-simulation interface is shared with our industry partner (PJM). 2) A structured reduced order dynamic model of distribution systems that can represent partial motor stalling along with a systematic procedure to derive the model parameters. 3) A PMU based online method to monitor, localize and mitigate fault-induced delayed voltage recovery using DER reactive support and load control in distribution systems. 4) Development of linear operator based robust methodologies for dynamic state estimation, uncertainty quantification, system identification and trajectory prediction for power system dynamics. 5) An adaptive damping control for utilizing wind energy resources to provide oscillation damping and system stability. 6) Implementation of Kafka-based framework for efficient processing of streaming data using Linux-based local virtual environment.

DER integration↗

Synergistic effects of chlorine substitution in sulfide electrolyte solid state batteries

All-solid-state battery is considered as one of the most promising competitors to Li ion batteries. Two widely known performance metrics for solid electrolytes, among others, are ionic conductivity and stability. In this study, it is found that both can be improved by the synergistic effects of chlorine substitution in sulfide-based solid electrolytes. Particularly, instabilities arising from both bulk decompositions and interfacial reactions to electrodes can be better inhibited in the chlorine substituted sulfide solid electrolytes through the increased susceptibility to the mechanical constriction induced enhancement of voltage stability. As a result, the stability window of some chlorine-rich Li-argyrodites can be systematically higher than some other chlorine-deficient or chlorine-free electrolytes, especially under the implementation of the mechanical constriction battery assembly and test conditions. Thus, a solid-state battery system of 4 V to 5 V-class cathodes paired with lithium metal anode is demonstrated using these chlorine-rich Li-argyrodites without additional coatings. Furthermore, since Cl composition modulates the stability and instability of Li-argyrodite at low voltages, it allows us to design a multilayer configuration with a hierarchy of Li metal stabilities to demonstrate the stable cycling at relatively high current densities for solid-state batteries. It is found that a moderate Cl composition in the electrolyte is the best to inhibit Li dendrite penetration as the central electrolyte layer, emphasizing a slightly increased “instability” as the hidden performance metric of relevance here, in addition to the two well-known metrics of stability and ionic conductivity. The understanding of the chlorine substitution effect in sulfide electrolytes provides an important design principle for all-solid-state batteries.

25 ENERGY STORAGE↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder: Preprint

This paper focuses on the harmonic load flow study for a set of residential loads and the impacts of the harmonic contents on the distribution feeder. Owing to the increased use of the power electronic based appliances and energy efficient home equipment like the lighting loads, the percentage of non-linear loads has increased in the distribution system which can impact the system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determining possible interactions at harmonic frequencies, protection planning, and the effect of the system impedance. For this study, the household appliances include the lighting, power electronics, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split-phase at a nominal frequency of 60 Hz. The harmonic spectrum as obtained from the experimental data is used to solve the harmonic load flow for a detailed secondary network including the distribution transformer extracted from a real distribution feeder's model. Additionally, the impact of the voltage harmonic on a three phase test load is presented through experimental results. The harmonic data of the transformer terminal voltage as obtained from the former load flow study is scaled to generate the source voltage for the three phase configuration of the grid simulator to make the test setup very similar to a real scenario.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synthetic, Realistic Transmission and Distribution Co-Simulation for Voltage Control Benchmarking: Preprint

As distributed energy resources play an increasing role in generation and grid services, control and market paradigms will need to be tested with models that incorporate transmission and distribution systems. The test systems will need to be realistic and accessible for researchers to form conclusions about realistic behaviors and maintain comparability and repeatability of results. These test systems also must have high resolution models of sufficient size for realistic distribution and transmission interaction. This paper demonstrates the tightly coupled co-simulation of realistic synthetic distribution and transmission models for the Austin metropolitan area and how this framework can be used to analyze resultant behaviors from distributed resources and their controls. The comparison of a distribution system run with fixed feed-in voltage is compared to the closely tied distribution-transmission co-simulation. It is determined that even without advanced voltage controls, the feed-in voltage response of the transmission system shows a lower level of voltage excursions. Therefore, control methods for voltage stability should be benchmarked on realistic transmission and distribution co-simulations for more accurate assessment of voltage profiles.

27 ARPA - Advanced Research Projects Agency-Energy↗

Intrusion Detection for Cybersecurity of Power Electronics Dominated Grids: Inverters PQ Set-Points Manipulation

This work provides cybersecurity analytics for a high photovoltaic (PV) penetrated distribution network, representing future power electronics dominated grid (PEDG). Firstly, the impact of active and reactive power (PQ) set-points manipulation on the network is studied. Then, an intrusion detection system (IDS) is developed for identifying the potentially compromised PV inverters in the network. The proposed IDS is based on defining the normal, safe, and abnormal operation regions of the PV inverters from point of view of the steady state voltage stability of the network. These three-operation regions are identified by utilizing active power, reactive power, and voltage (PQV) limits of each specific grid-following inverter in the network. Each grid-following inverter's PQV contour includes the information of network topology, inverter ratings, and inverter controller. The developed PQ limits are integrated into the centralized secondary control layer for realization of the proposed IDS. Furthermore, the proposed secondary control layer is capable of providing remedial actions during an anomaly event to enhance the grid resiliency. The theoretical analyses are verified by several attack scenarios for a network of grid-following inverters.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Analytical Voltage Sensitivity Analysis for Unbalanced Power Distribution System

Large scale integration of distributed energy resources and electric vehicles in a transactive energy environment present new challenges in terms of voltage stability and fluctuations in a power distribution system. The impact of different level of DER/EV penetration on the voltages across the network is typically quantified through voltage sensitivity analyses. Existing methods of voltage sensitivity analysis are computationally expensive and prior efforts to develop analytical approximation lacks generality and have not been effectively validated. The objective of this work is to provide a new analytical method of voltage sensitivity analysis that has low computational cost and also allows for stochastic analysis of voltage change. This paper first derives an analytical approximation of change in voltage at a particular bus due to change in power consumption at other bus in a radial three phase unbalanced power distribution system. Then, the proposed method is shown to be valid for different load configurations, which demonstrates its generality. The results from our analytical approach is validated via classical load flow simulation of the test system based on IEEE 37 bus network. The proposed method is shown to have good accuracy, and computation complexity is of order O(1), compared to O(n3) in classical sensitivity analysis approaches.

Munikoti, Sai↗