Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Improving photovoltaic hosting capacity of distribution networks with coordinated inverter control: A case study of the EPRI J1 feeder

Abstract Adding photovoltaic (PV) systems in distribution networks, while desirable for reducing the carbon footprint, can lead to voltage violations under high solar‐low load conditions. The inability of traditional volt‐VAr control in eliminating all the violations is also well‐known. This article presents a novel coordinated inverter control methodology that leverages system‐wide situational awareness to significantly improve hosting capacity (HC). The methodology employs a real‐time voltage‐reactive power (VQ) sensitivity matrix in an iterative linear optimizer to calculate the minimum reactive power intervention from PV inverters needed for mitigating over‐voltage without resorting to active power curtailing or requiring step voltage regulator setting changes. The algorithm is validated using the EPRI J1 feeder under an extensive set of realistic use cases and is shown to provide 3x improvement in HC under all scenarios.

Dalal, Dhaval [School of Electrical, Computer, and↗

Adaptive Voltage Regulation for Solar Power Inverters on Distribution Systems

The most recent version of IEEE 1547 has incorporated four reactive power control modes, including constant power factor, voltage-reactive power (Volt-Var), active power-reactive power and constant reactive power. These modes are specified to be mutually exclusive, and they don’t include every smart inverter function proposed by industry collaboration. In earlier work, we found that Volt-Var settings could be optimized but were sensitive to changes in the normal grid voltage. This sensitivity can be mitigated by combining Volt-Var with dynamic reactive current (DRC), but neither DRC nor combined modes appear in IEEE 1547. One problem with Volt-Var is the default dead-band; it mitigates the sensitivity to setpoint, but also limits the effectiveness in managing voltage fluctuations. There has been continued interest in tuning smart inverter functions locally, and in combining central with local control, but this process still requires extensive simulations. The goal is to find a default inverter setting that will effectively mitigate voltage fluctuations even as grid conditions change. It must be compatible with the current version of IEEE 1547. It should also be compatible with advanced control methods when available. Otherwise, it should not require communications, detailed engineering studies or field commissioning of custom settings. This would facilitate the integration of distributed solar in larger amounts. Adaptive voltage regulation (AVR) is a Volt-Var implementation, but with “autonomously adjusting” setpoint as described below Table 8 in IEEE 1547. Through simulation of a test system in OpenDSS, it was shown that AVR having a high gain and a time constant of 300 seconds could work well in any location. This mode and setting should be considered for a new universal default setting on smart inverters.

McDermott, Thomas E.↗

Strategies for Enhancing Battery Life Under Fast Charging: Insights from NMC-Based Cell Cycling

Fast charging improves the usability of consumer electronics and electric vehicles (EVs) by reducing range anxiety and downtime but accelerates battery degradation and raises safety concerns. Optimizing operational conditions during fast-charging is critical to mitigating aging and ensuring safety. This study evaluated multilayer Gr/NMC811 cells under various conditions, including depths of discharge (DODs of 68%, 84%, and 100%), upper charge cutoff voltages (4.1–4.2 V), and post-charge rest periods (2–30 min), using a 20 min fast charging protocol for up to 500 cycles (up to 150,000 miles of EV use assuming 3.3 mi/kWh vehicle level energy efficiency). Surprisingly, higher DODs under fast charging improved battery life and performance compared to lower DODs. Reducing the upper charge cut-off voltage helped mitigate degradation. A brief 2 min rest period after charging further reduced aging effects. The primary aging modes were loss of lithium inventory and cathode active material. Although minor lithium plating was observed within 500 cycles, it did not affect performance significantly. These findings suggest that, with optimized conditions, cells can sustain hundreds of fast charge cycles—equivalent to over 100,000 miles of EV use—without significant adverse effects on performance or longevity.

25 - ENERGY STORAGE↗

Voltage Control Strategy for Energy Storage System in Sustainable Distribution System Operation

Due to the increasing penetration of distributed energy resources (DERs) required for the sustainable distribution system, new voltage control strategy is needed by utilities. Traditional voltage control strategy can not support the increasing number of DERs in a coordinated and scalable manner to meet the operational voltage regulation requirement. Supported by the power electronics converter, the energy storage system can provide fast, smooth, and flexible voltage control services. In this paper, an effective and easy to implement sensitivity-based voltage control strategy is developed for the energy storage system. The developed control strategy is validated using an industrial feeder data in Northwest Washington. The proposed strategy can mitigate the voltage unbalance issue, improve the voltage profile, and correct power factors while supporting sustainable distribution system operation.

Zhang, Yue (ORCID:0000000241469716)↗

Device Voltage Stress from Ground Leakage Current in Medium-Voltage Solid-State Transformer

Grounding related issues are critical for safe and reliable operation of solid-state transformer (SST) in medium-voltage (MV) applications, e.g., solar photovoltaic and energy storage integration, date center, electric vehicle fast charging, etc. This article presents for the first time the issue of additional device voltage stress due to grounding-loop current in current-source SST, using the soft-switching solid-state transformer (S4T) as an example. The S4T features single-stage isolated AC-AC, AC-DC, or DC-DC conversion with full-range ZVS, derived from flyback converter or current-source converter (CSC). However, the flyback operation for CSC-based SST means that magnetizing current flows through the reverse-blocking devices on only one side of the medium-frequency transformer (MFT) at a time. Then, the voltages across the devices, especially those on the other side of the MFT, can be influenced by parasitic current. A parasitic model of a modular S4T (M-S4T) prototype is developed from direct measurements and datasheets. Using the developed parasitic model and equivalent circuits, the causes of the voltage stress are analyzed. A voltage-stress mitigation scheme of connecting additional grounding capacitors is proposed. Damping resistors are also installed to damp out the grounding-loop resonance. A robust parameter design of the proposed scheme is given. The existence of the voltage stress issue and the effectiveness of the proposed scheme are verified experimentally on an MV SiC M-S4T prototype with inherent parameter variations among the five modules in the prototype. Here, both single-module and stacked-module operation are demonstrated during steady state and dynamic conditions up to 4 kV peak.

42 ENGINEERING↗

NREL/SCE High-Penetration PV Integration Project: Report on Field Demonstration of Advanced Inverter Functionality in Fontana, CA

The National Renewable Energy Laboratory/Southern California Edison High-Penetration PV Integration Project is (1) researching the distribution system level impacts of high-penetration photovoltaic (PV) integration, (2) determining mitigation methods to reduce or eliminate those impacts, and (3) seeking to demonstrate these mitigation methods on actual high-penetration PV distribution circuits. This report describes a field demonstration completed during the fall of 2013 on the Fontana, California, study circuit, which includes a total of 4.5 MW of interconnected utility-scale rooftop PV systems. The demonstration included operating a 2-MW PV system at an off-unity power factor that had been determined during previously completed distribution system modeling and PV impact assessment analyses. Data on the distribution circuit and PV system operations were collected during the 2-week demonstration period. This demonstration reinforces the findings of previous laboratory testing that showed that utility-scale PV inverters are capable of operating at off-unity power factor to mitigate PV impacts; however, because of difficulties setting and retaining PV inverter power factor set points during the field demonstration, it was not possible to demonstrate the effectiveness of off-unity power factor operation to mitigate the voltage impacts of high-penetration PV integration. Lessons learned from this field demonstration are presented to inform future field demonstration efforts.

14 SOLAR ENERGY↗

Sequential Mitigation Solutions to Enable Distributed PV Grid Integration: Preprint

This paper provides a method to assess the impact of multiple mitigation solutions including distribution grid upgrades and advanced control technologies on increasing distributed PV penetration in distribution feeders, and thus paves the way to estimate the costs needed for reaching certain PV penetration level. Based on three assumptions of creating increasing PV penetration scenarios, this paper first studies the distribution impact of PV power and quantifies the PV hosting capacity in distribution feeders. Then, it studies multiple mitigation solutions to increase PV penetration on distribution feeders. These mitigation solutions are implemented in a sequential manner according to their typical costs. The proposed study is demonstrated on two representative distribution feeders.

14 SOLAR ENERGY↗

Sequential Mitigation Solutions to Enable Distributed PV Grid Integration

This paper presents a method to assess the technical impacts of a series of distribution system mitigations for integrating increasing penetrations of distributed generation from solar photovoltaics (DGPV). Solutions considered include distribution grid upgrades and advanced control technologies. This study helps pave the way to estimate the distribution integration costs needed to reach various PV penetration levels. The approach uses three stream-lined, bounding scenarios for increased PV penetration patterns. It begins by studying the distribution impact of PV power and quantifying the PV hosting capacity. Then, it studies multiple mitigation solutions to increase PV penetration on distribution feeders. These mitigation solutions are implemented in a sequential manner according to their typical costs. The proposed technique is demonstrated on two representative distribution feeders.

14 SOLAR ENERGY↗

New Modulation and Impact of Transformer Leakage Inductance on Current-Source Solid-State Transformer

This article presents a novel modulation scheme for device voltage stress mitigation and comprehensive analysis of the impact of transformer leakage inductance in a current-source solid-state transformer (SST). Different from dual active bridge (DAB) SST, the operation of the current-source SST is similar to that of a flyback converter. The device bridge on only one side of the transformer is active to store energy into or release energy from the magnetizing inductance which acts as a current-source dc link. Such flyback operation with reverse-blocking switches can lead to additional device voltage stress and incomplete zero-voltage switching (ZVS) on the current-source soft-switching solid-state transformer (S4T) under conventional modulation. A new modulation scheme is proposed to address this issue. Moreover, different from the DAB, the leakage inductance of the medium-frequency transformer (MFT) in the S4T is a parasitic element similar to that in a matrix SST and can cause additional device voltage stress. Though the resonant capacitors, originally added to achieve ZVS, can absorb and recycle the leakage energy in the S4T, these capacitors need to be increased with larger leakage inductances to limit the voltage stress. However, large resonant capacitors can result in more lost duty cycles and reduced efficiency. The impact of such leakage inductance on device voltage stress is analyzed comprehensively, which is critical to guide future research and design of the S4T. Experimental results from S4T prototypes for DC-DC, multiport AC-DC, and AC-AC conversion with 1:1 and 4:1 MFT comprehensively verify the proposed concepts. Lastly, a case study of a three-phase AC-AC S4T over a power range from 1 kVA to 100 kVA each module reveals that the MFT leakage inductance should be less than 1% of the magnetizing inductance for safe operation.

14 SOLAR ENERGY↗

Optimal Discrete Net-Load Balancing in Smart Grids with High PV Penetration

Mitigating supply-demand mismatch is essential for smooth power grid operation. Traditionally, load curtailment techniques such as demand response have been used for this purpose. However, these cannot be the only component of a net-load balancing framework for smart grids with high PV penetration. These grids sometimes exhibit supply surplus, causing overvoltages. Currently, these are mitigated using voltage manipulation techniques such as Volt-Var Optimizations, which are computationally expensive, thereby increasing the complexity of grid operations. Taking advantage of recent technological developments that enable rapid selective connection of PV modules of an installation to the grid, we develop a unified net-load balancing framework that performs both load and solar curtailment. We demonstrate that when the available curtailment values are discrete, this problem is NP-hard and we develop bounded approximation algorithms. Our algorithms produce fast solutions, given the tight timing constraints required for grid operation, while ensuring that practical constraints such as fairness, network capacity limits, and so forth are satisfied. We also develop an online algorithm that performs net-load balancing using only data available for the current interval. Using both theoretical analysis and practical evaluations, we show that our net-load balancing algorithms provide solutions that are close to optimal in a small amount of time.

14 SOLAR ENERGY↗

Hybrid Ag 2 VO 2 PO 4 /CF x as a High Capacity and Energy Cathode for Primary Batteries

In this report, we describe the electrochemistry of hybrid dual silver vanadium phosphorus oxide/carbon fluoride (Ag 2 VO 2 PO 4 /CF x ) cathodes with various weight ratios. Through modification of the Ag 2 VO 2 PO 4 /CF x ratio, we can control the gravimetric and volumetric capacity, as well as mitigate the voltage drop during high current pulses. The increase in impedance caused by irreversible LiF formation in CFx was reduced by the silver reduction-displacement during electrochemical discharge of the Ag 2 VO 2 PO 4 . Moreover, the addition of graphite was shown to reduce initial voltage delay. When Ag 2 VO 2 PO 4 dominates the electrode mass (i.e. 75/25 Ag 2 VO 2 PO 4 /CF x ) in the hybrid cathode, pulse testing shows less voltage drop and delay, but at the expense of capacity and energy density. As the amount of CFx in the composite increases (i.e. Ag 2 VO 2 PO 4 /CF x ratio of to 50/50 or 25/75), charge capacity and energy density increases, but at the expense of larger voltage drops and delays early in the discharge process. Thus, controlling the Ag 2 VO 2 PO 4 /CF x ratio can be used to tune the electrochemical properties of the dual cathode, allowing for optimization of capacity and power depending on the application.

25 ENERGY STORAGE↗

An Analysis of Electrostatic Discharge Considerations in the Use of Sodium Bicarbonate Media for De-Potting Sensitive Electronic Assemblies

Sodium bicarbonate blast media offers superior performance in removing low-to-medium density polyurethane foam potting materials from electronic assemblies compared to conventional abrasive or other low-hardness blast media. This work identifies a class of processing equipment suitable for potting removal in electronic assemblies and provides a technical evaluation of appropriate process controls that significantly reduce the potential for Electrostatic Discharge (ESD) degradation or damage. Once appropriate process controls are added, the class of blast equipment demonstrated here, previously used only for non-ESD sensitive assemblies, can be safely used to provide new capabilities for component-level support. In many cases, assemblies that have been de-potted using sodium bicarbonate can be disassembled and rebuilt using normal production processes, enabling repair, reacceptance, and surveillance of assemblies that was previously impractical. This paper presents the results of a study that identifies significant process variables and their contribution to ESD generation. Data are presented to quantify process-related peak ESD voltages and mitigation methods. A discussion of how to implement practical ESD controls and de-potting process test methodologies is provided. The intent of this work is to document foundational experimental work that provides a technical basis for sodium bicarbonate as an ESD-safe material for use in de-potting processes when appropriate controls are implemented.

Kinzel, Robert L.↗

Electrochemical CO 2 Utilization: Scalable System Operation for Formic Acid Production

In recent years, research into the electrochemical reduction of CO 2 has grown exponentially. Formic acid (FA) has become a particular value product from CO 2 due to its versatility [1], optimal atom economy [2], and thermodynamic favorable [3]. FA can be produced electrochemically via a direct two-electron transfer process involving CO 2 with a proton source, requiring less energy input and fewer reaction steps than the conventional Kemira process. However, product selectivity, electrode stability, and low faradic efficiency due to increased resistance under constant current, remain key issues for CO 2 reduction to FA [4]. University of Kentucky’s Center for Applied Energy Research (UK CAER) is currently investigating reactor designs to address the challenges associated with electrochemical CO 2 conversion to FA [5]. The current reactor system employs: (1) an organic-based charge carrier which shuttles charge directly to the catalyst to enable CO 2 reduction to FA; (2) novel electrode materials to mitigate large voltages and improve conductivity; and (3) a flow system which not only allows for the volumetric scale-up of both charge carrier and catalyst, but also decouples the charger carrier re-energized and FA production processes to protect the catalyst’s stability due to overpotential. Through careful adjustment of electrode, charge carrier, and electrolyte selection, cell resistances have decreased by over 15%, facilitating conduction necessary for effective CO 2 reduction to FA. The system uses a highly specific engineered catalyst, which has produced over 100 mM FA at a rate of over 10 mM FA/hour following the aforementioned electrode/charge carrier changes. System design considerations (flow rate, bulk volume) and modeling of the system will also be discussed.

20 FOSSIL-FUELED POWER PLANTS↗

Feasibility Analyses for the Microgrid of the Mountain in the Cordillera Central Region of Puerto Rico

Distributed energy resource (DER) development can benefit communities through improvement of access to reliable electricity and a resilient energy system. Many place-specific considerations must be accounted for when designing electrical systems with co-located generation and loads. This paper presents an overview of four studies focusing on different aspects for regional DER development in the Cordillera Central region of Puerto Rico, including a grid and load stability study with the introduction of solar energy generation, microgrid design based on the solar resource in the area, resilience considerations during power outage scenarios, and qualitative risk aspects for components in the microgrid. Additionally, a conceptual substation microgrid analysis is conducted using the Microgrid Design Toolkit (MDT) to evaluate trade-offs between cost and energy availability, providing insights into optimal design strategies. A microgrid resilience assessment is performed using the Resilient Nodal Cluster Analysis Tool (ReNCAT) to identify critical loads and evaluates their accessibility during outages, emphasizing the importance of community needs. Finally, a qualitative risk assessment utilizing Hazard and Operability Analysis (HAZOP) methods highlights potential hazards and mitigations for microgrid components, ensuring robust system design and operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reverse bias protected solar array with integrated bypass battery

A method for protecting the photovoltaic cells in a photovoltaic (PV) array from reverse bias damage by utilizing a rechargeable battery for bypassing current from a shaded photovoltaic cell or group of cells, avoiding the need for a bypass diode. Further, the method mitigates the voltage degradation of a PV array caused by shaded cells.

Landis, Geoffrey A↗

Progress and Challenges in Absorber and Interface Fabrication of Polycrystalline CdTe Photovoltaics

Polycrystalline thin-film CdTe device efficiency of over 19% has been achieved at Colorado State University using a highly repeatable and scalable sublimation process. Record efficiency for research scale CdTe photovoltaics has been reported to be over 22% and highest reported module efficiency is over 18% by First Solar Inc. Use of Se alloying with CdTe to form a lower band-gap CdSexTe1-x (CST) alloy has led to higher devices efficiencies with better current collection. Recent materials characterization has revealed that Se may be responsible for more than just reduction of band-gap. With CdCl2 treatment Cl is known to very effectively passivate defects at CdTe grain boundaries. Recent materials and electrical characterization have shown that Se has a very similar behavior to Cl at the grain boundaries of polycrystalline CdTe. These include Se decorating the grain boundaries like Cl in the diffusion region between CST and CdTe while cross-section cathodoluminescence maps show substantially higher signal intensity in regions with Se. Double heterostructures fabricated using CdSeTe with Al2O3 as a passivating oxide have been measured to have several hundred nanosecond bulk recombination lifetime. These films were also measured to have surface recombination velocity of under 100 cm/s. These results among others emphasis that Se also helps in passivation of grain boundaries. High absorber quality may help in mitigating the voltage deficit that has traditionally been the largest limiting factor in CdTe photovoltaics in achieving efficiency closer to Shockley-Queisser limit. In addition to graded absorber devices and double heterostructures, replacing the traditional Cu doping with more advanced group V doping is an important research effort that maybe critical for future improvements in device efficiency. Nitrogen, Phosphorous, Arsenic and Antimony doping has been investigated by several research groups. Advanced co-sublimation hardware developed at Colorado State University provides researchers with a unique capability of depositing films for group V doping with Cd overpressure. Such deposition under Cd overpressure causes formation of CdV which is known to be favorable for incorporation of group V dopant and activation. Utilizing the high absorber and interface quality material and higher doping, efforts are in progress to fabricate polycrystalline devices with open-circuit voltage over 1V and device efficiency over 24%.

Munshi, Amit↗

Deep Reinforcement Learning Enabled Physical-Model-Free Two-Timescale Voltage Control Method for Active Distribution Systems

Active distribution networks are being challenged by frequent and rapid voltage violations due to renewable energy integration. Conventional model-based voltage control methods rely on accurate parameters of the distribution networks, which are difficult to achieve in practice. This paper proposes a novel physical-model-free two-timescale voltage control framework for active distribution systems. To achieve fast control of PV inverters, the whole network is first partitioned into several subnetworks using voltage-reactive power sensitivity. Then, the scheduling of PV inverters in the multiple sub-networks is formulated as Markov games and solved by a multi-agent soft actor-critic (MASAC) algorithm, where each subnetwork is modeled as an intelligent agent. All agents are trained in a centralized manner to learn a coordinated strategy while being executed based on only local information for fast response. For the slower time-scale control, OLTCs and switched capacitors are coordinated by a single agent-based SAC algorithm using the global information with considering control behaviors of the inverters. Particularly, the two-level agents are trained concurrently with information exchange according to the reward signal calculated from the data-driven surrogate model. Comparative tests with different benchmark methods on IEEE 33-and 123-bus systems and 342-node low voltage distribution system demonstrate that the proposed method can effectively mitigate the fast voltage violations and achieve systematical coordination of different voltage regulation assets without the knowledge of accurate system model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

State-of-the-Art Medium- and High-Voltage Silicon Carbide Power Modules, Challenges and Mitigation Techniques: A Review

Silicon carbide (SiC) power modules have been demonstrated potential for improving power density and efficiency for low-voltage power electronics systems. This has resulted in a paradigm shift toward development of medium-voltage and high-voltage (MV/HV) SiC power modules to revolutionize the future power grid and transportation systems. However, designing MV/HV SiC power modules involves significant design challenges due to higher blocking voltage and exacerbation of side effects due to high switching dv/dt and di/dt of SiC devices-concerns that may not be as critical as in low-voltage module development. This article reviews the development of state-of-the-art MV/HV SiC power modules, ranging from 3.3 kV to 40 kV, from both industry and academia. First, a discussion on SiC modules based on voltage level is presented. This is followed by a discussion of challenges associated with designing and testing MV/HV modules- including parasitic controls, electromagnetic interference (EMI), partial discharge, and thermal management-and the corresponding mitigation approaches from various perspectives. We conclude with a summary of major findings and future directions for the development of MV/HV modules.

EMI↗