Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Error analysis and corrections to pupil diameter measurements with Langley Research Center's oculometer

Factors that can affect oculometer measurements of pupil diameter are: horizontal (azimuth) and vertical (elevation) viewing angle of the pilot; refraction of the eye and cornea; changes in distance of eye to camera; illumination intensity of light on the eye; and counting sensitivity of scan lines used to measure diameter, and output voltage. To estimate the accuracy of the measurements, an artificial eye was designed and a series of runs performed with the oculometer system. When refraction effects are included, results show that pupil diameter is a parabolic function of the azimuth angle similar to the cosine function predicted by theory: this error can be accounted for by using a correction equation, reducing the error from 6% to 1.5% of the actual diameter. Elevation angle and illumination effects were found to be negligible. The effects of counting sensitivity and output voltage can be calculated directly from system documentation. The overall accuracy of the unmodified system is about 6%. After correcting for the azimuth angle errors, the overall accuracy is approximately 2%.

Fulton, C. L.↗

Grid-Forming Control Using TAPAS Software Defined Inverters

Here, this paper discusses the design and hardware implementation aspects of state-feedback primary control for grid forming inverters. The primary control consists of two tracking control laws: voltage tracking and frequency/angle tracking. The voltage tracking control requires voltage and current at the inverter's switch terminal (i.e. before the filter). The fundamental component of switch terminal voltage is estimated using the inverter's average model while the switch terminal current is estimated using an observer, thus obviating the need for sensors at the switch terminals. The measurements of frequency and angle(s) needed for frequency/angle tracking are noisy due to measurement noises and inherent delays in the phase locked loop (PLL). Conditioning of these feedback signals is discussed in detail, and the corresponding changes in the control design are provided to better attenuate the impact of noises. Effectiveness of the proposed design and implementation is demonstrated by the implementation results from TAPAS software defined inverter (SDI).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Power Flow With State Estimation in the Loop for Distribution Networks

Here in this article, we propose a framework for running optimal control-estimation synthesis in distribution networks. Our approach combines a primal-dual gradient-based optimal power flow solver with a state estimation feedback loop based on a limited set of sensors for system monitoring, instead of assuming exact knowledge of all states. The estimation algorithm reduces uncertainty on unmeasured grid states based on certain online state measurements and noisy "pseudomeasurements." We analyze the convergence of the proposed algorithm and quantify the statistical estimation errors based on a weighted least-squares estimator. The numerical results on a 4521-node network demonstrate that this approach can scale to extremely large networks and provide robustness to both large pseudomeasurement variability and inherent sensor measurement noise.

24 POWER TRANSMISSION AND DISTRIBUTION↗

H 2 O absorption spectroscopy via focused laser differential interferometry

A modification of focused laser differential interferometry (FLDI) is demonstrated with an infrared tunable diode laser (TDL) to achieve simultaneous absorption spectroscopy (AS) measurements. Measurements from this absorbing-FLDI (A-FLDI) are shown for a Hencken burner plume. Initial comparison measurements are recorded using TDLAS and an electrical hygrometer. Raw voltage and estimated absorbance measurements illustrate that the technique detects five distinct absorbance peaks of the methane–air flame while retaining the expected behavior of typical FLDI. This modification furthers efforts to enable FLDI to conduct analysis of the pressures, temperatures, and molecular densities of flows. It also explores the potential for reducing path-integration (PI) effects in absorption spectroscopy and potentially enabling spatially and temporally resolved local flow measurements. Reductions in PI length as high as 82%–84% are observed.

Holladay, Seth (ORCID:0009000650875421)↗

Optimal Electrification Using Renewable Energies: Microgrid Installation Model with Combined Mixture k-Means Clustering Algorithm, Mixed Integer Linear Programming, and Onsset Method

Optimal planning and design of microgrids are priorities in the electrification of off-grid areas. Indeed, in one of the Sustainable Development Goals (SDG 7), the UN recommends universal access to electricity for all at the lowest cost. Several optimization methods with different strategies have been proposed in the literature as ways to achieve this goal. This paper proposes a microgrid installation and planning model based on a combination of several techniques. The programming language Python 3.10 was used in conjunction with machine learning techniques such as unsupervised learning based on K-means clustering and deterministic optimization methods based on mixed linear programming. These methods were complemented by the open-source spatial method for optimal electrification planning: onsset. Four levels of study were carried out. The first level consisted of simulating the model obtained with a cluster, which is considered based on the elbow and k-means clustering method as a case study. The second level involved sizing the microgrid with a capacity of 40 kW and optimizing all the resources available on site. The example of the different resources in the Togo case was considered. At the third level, the work consisted of proposing an optimal connection model for the microgrid based on voltage stability constraints and considering, above all, the capacity limit of the source substation. Finally, the fourth level involved a planning study of electrification strategies based mainly on microgrids according to the study scenario. The results of the first level of study enabled us to obtain an optimal location for the centroid of the cluster under consideration, according to the different load positions of this cluster. Then, the results of the second level of study were used to highlight the optimal resources obtained and proposed by the optimization model formulated based on the various technology costs, such as investment, maintenance, and operating costs, which were based on the technical limits of the various technologies. In these results, solar systems account for 80% of the maximum load considered, compared to 7.5% for wind systems and 12.5% for battery systems. Next, an optimal microgrid connection model was proposed based on the constraints of a voltage stability limit estimated to be 10% of the maximum voltage drop. The results obtained for the third level of study enabled us to present selective results for load nodes in relation to the source station node. Finally, the last results made it possible to plan electrification using different network technologies and systems in the short and long term. The case study of Togo was taken into account. The various results obtained from the different techniques provide the necessary leads for a feasibility study for optimal electrification of off-grid areas using microgrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Current Observer Based Predictive Decoupled Power Control Grid-Interactive Inverter

This paper presents a sensor-less current model predictive control (MPC) scheme via a full state observer based current estimator. The grid interactive inverters’ control schemes require current and voltage sensors. Elimination of current sensor enhances the inverter reliability. This paper leverages the inherent characteristics of MPC towards robust current sensor-less grid interactive inverter with LC filter. The observer for inductor current is developed based on the existing capacitor voltage measurement. The estimator dynamic state-space matrices are then obtained through reconstruction of the inverter model with the capacitor voltage and inductor current being the state variables. The controller objectives are to regulate active and reactive power in a decoupled manner. The theoretical expectation, controller performance, and accuracy of the current estimation are verified by conducting a real-time simulation via Typhoon HIL.

Zhang, Zhen↗

Model-Free Probabilistic Forecasting of Nodal Voltages in Distribution Systems

As the penetration of distributed energy resources (DERs) into distribution systems increases, so does the interest in forecasting relevant system variables to help mitigate the associated challenges. One such challenge is the more frequent occurrence of excessive voltages in distribution systems with higher shares of DERs. Accurate and reliable estimates together with forecasts of system states (i.e., nodal voltages) will therefore play a key role in improving the utilization of these variable and uncertain sources while mitigating potential operational risks. Whilst recent literature has explored machine learning (ML) methods for voltage estimation and their extrapolation for a short-time period into the future, few have taken uncertainty quantification into account, and these methods have not yet been translated into operations. This paper discusses the advantages offered by probabilistic voltage forecasts and proposes a non-parametric Bayesian method suitable for forecasting nodal voltages at short-term time horizons while accounting for uncertainties in load and distributed photovoltaic (PV) generation. We demonstrate the value of the proposed Gaussian process (GP) model for a case study using historical forecasts and observation data.

distribution system↗

Speed Sensorless Induction Motor Drives for Electrical Actuators: Schemes, Trends and Tradeoffs

For a decade, induction motor drive-based electrical actuators have been under investigation as potential replacement for the conventional hydraulic and pneumatic actuators in aircraft. Advantages of electric actuator include lower weight and size, reduced maintenance and operating costs, improved safety due to the elimination of hazardous fluids and high pressure hydraulic and pneumatic actuators, and increased efficiency. Recently, the emphasis of research on induction motor drives has been on sensorless vector control which eliminates flux and speed sensors mounted on the motor. Also, the development of effective speed and flux estimators has allowed good rotor flux-oriented (RFO) performance at all speeds except those close to zero. Sensorless control has improved the motor performance, compared to the Volts/Hertz (or constant flux) controls. This report evaluates documented schemes for speed sensorless drives, and discusses the trends and tradeoffs involved in selecting a particular scheme. These schemes combine the attributes of the direct and indirect field-oriented control (FOC) or use model adaptive reference systems (MRAS) with a speed-dependent current model for flux estimation which tracks the voltage model-based flux estimator. Many factors are important in comparing the effectiveness of a speed sensorless scheme. Among them are the wide speed range capability, motor parameter insensitivity and noise reduction. Although a number of schemes have been proposed for solving the speed estimation, zero-speed FOC with robustness against parameter variations still remains an area of research for speed sensorless control.

Elbuluk, Malik E.↗

Physics-constrained deep neural network method for estimating parameters in a redox flow battery

Here, in this paper, we present a physics-constrained deep neural network (PCDNN) method for parameter estimation in the zero-dimensional (0D) model of the vanadium redox flow battery (VRFB). In this approach, we use deep neural networks to approximate the model parameters as functions of the operating conditions. This method allows the integration of VRFB computational models as the physical constraints in the parameter learning process, leading to enhanced accuracy of parameter estimation and cell voltage prediction. Using an experimental dataset, we demonstrate that the PCDNN method can estimate model parameters for a range of operating conditions and improve the 0D model prediction of voltage compared to the 0D model prediction with constant operation-condition-independent parameters estimated with traditional inverse methods. We also demonstrate that the PCDNN approach has an improved generalization ability for estimating parameter values for operating conditions not used in the training process.

25 ENERGY STORAGE↗

Performance of Two Battery Prognostic Applications used by Two Octocopters for Safe Low Altitude Autonomous Flight Operations

This paper addresses the problem of building trust in online predictions of the remaining available flying time for two different electric Unmanned Aerial Vehicles (eUAVs) powered by lithium-ion-polymer batteries. Flight tests for various automation research missions for the two vehicles were monitored using two on-board battery health management applications to make predictions of the remaining flying time (RFT) for each eUAV and to predict the state of the battery. Playback of the voltage, current and temperature profiles of the battery discharge were used to assess the accuracy of the estimation of the voltage and the charge states of the models as well as the estimate of the RFT. The reference ground truth values were the observed landing time and the measured battery pack resting pack voltage 20 minutes after the flight. The predicted RFT, state of charge (SoC), and state of energy (SoE) were compared with the observed results. Noise values of one standard deviation from the mean values of the internal charge states of the battery model during a reference run were used to vary the states during simulation. One application used an equivalent circuit model of the electrical dynamics of the battery pack, and the other application used a reduced-order electrochemistry model. The variation of the model state components was compared to the variation in the estimate of the RFT and the variation in the SoE to estimate a confidence factor. Variation in the estimates caused by factors affecting the off-line laboratory parameter identification experiments is considered. Variation in the estimates due to environmental factors are discussed.

Assurance↗

Isothermal Microcalorimetric Analysis of Li/CF x Battery Discharge

Lithium/carbon monofluoride (Li/CF x ) batteries generate substantial amounts of heat during discharge in part due to the large deviation of the loaded voltage from the measured and thermodynamically predicted open circuit voltage. Here, in this study, we further analyze this system by estimating the equilibrium voltage (V eq ) and its temperature dependence (dV eq /dT) over the entire discharge range. Based on these results, the ohmic and entropic heat contributions to the overall heat flow are calculated from experimental data. The ohmic heat flow is consistent with an electrochemical impedance spectroscopy model and electrode density measurements, indicating decreasing porosity of the electrode during discharge. Entropic heating increases during discharge as the cell reaction becomes increasingly entropically unfavorable. The total energy dissipated by the cell (electrical and thermal) remains similar over the entire discharge, evidence for a two-phase reaction with a constant, and rate-independent, ΔG rxn of about -465 kJ mol -1 . However, near the end of discharge (>90% DOD), ΔG rxn changes significantly indicating possible secondary reactions.

25 ENERGY STORAGE↗

State Estimation-Based Distributed Energy Resource Optimization for Distribution Voltage Regulation in Telemetry-Sparse Environments Using a Real-Time Digital Twin

Real-time state estimation using a digital twin can overcome the lack of in-field measurements inside an electric feeder to optimize grid services provided by distributed energy resources (DERs). Optimal reactive power control of DERs can be used to mitigate distribution system voltage violations caused by increased penetrations of photovoltaic (PV) systems. In this work, a new technology called the Programmable Distribution Resource Open Management Optimization System (ProDROMOS) issued optimized DER reactive power setpoints based-on results from a particle swarm optimization (PSO) algorithm wrapped around OpenDSS time-series feeder simulations. This paper demonstrates the use of the ProDROMOS in a RT simulated environment using a power hardware-in-the-loop PV inverter and in a field demonstration, using a 678 kW PV system in Grafton (MA, USA). The primary contribution of the work is demonstrating a RT digital twin effectively provides state estimation pseudo-measurements that can be used to optimize DER operations for distribution voltage regulation.

Darbali-Zamora, Rachid↗

A Software/Hardware Framework for Efficient and Safe Emergency Response in Post-Crash Scenarios of Battery Electric Vehicles

The adoption rate of battery electric vehicles (EVs) is rapidly increasing. Electric vehicles differ significantly from conventional internal combustion engine vehicles and vary widely across different manufacturers. Emergency responders (ERs) and recovery personnel may have less experience with EVs and lack timely access to critical information such as the extent of the stranded energy present, high-voltage safety hazards, and post-crash handling procedures in a user-friendly manner. This paper presents a software/hardware interactive tool named Electric Vehicle Information for Incident Response Solutions (EVIRS) to aid in the quick access to emergency response and recovery information. The current prototype of EVIRS identifies EVs using the VIN or Make, Model, and Year, and offers several useful features for ERs and recovery personnel. These features include integration and easy access to emergency response procedures tailored to an identified EV, vehicle structural schematics, the quick identification of battery pack specifications, and more. For EVs that are not severely damaged, EVIRS can perform calculations to estimate stranded energy in the EV’s battery and discharge time for various power loads using either EV dashboard information or operational data accessed through the CAN interface. Knowledge of this information may be helpful in the post-crash handling, management, and storage of an EV. The functionality and accuracy of EVIRS were demonstrated through laboratory tests using a 2021 Ford Mach-E and associated data acquisition system. The results indicated that when the remaining driving range was used as an input, EVIRS was able to estimate the pack voltage with an error of less than 3 V. Conversely, when pack voltage was used as an input, the estimated state of charge (SOC) error was less than 5% within the range of 30–90% SOC. Additionally, other features, such as retrieving emergency response guides for identified EVs and accessing lessons learned from archived incidents, have been successfully demonstrated through EVIRS for quick access. EVIRS can be a valuable tool for emergency responders and recovery personnel, both in action and during offline training, by providing crucial information related to assessing EV/battery safety risks, appropriate handling, de-energizing, transport, and storage in an integrated and user-friendly manner.

25 ENERGY STORAGE↗