Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Conversion of spectral characteristics of laser radiation in periodic domain structures written by the electron-beam method in planar waveguides formed by Ti diffusion in Y-oriented LiNbO{sub 3}

Periodic domain structures for nonlinear conversion of spectral characteristics of laser radiation in the planar Ti : LiNbO{sub 3} waveguide have been formed by the method of electron-beam writing. Domain gratings with a spatial period of 6.50 μm formed in the Y-cut plate over a wide range of accelerating voltages have been visualised by the method of second harmonic generation microscopy (SHG-microscopy) in transmitting geometry and at waveguide excitation. It is found that the domain structure written at an accelerating voltage of 10 kV in a waveguide with an exponential refractive index profile and an effective thickness of 1.75 μm is characterised by high homogeneity. It is composed of continuous domain rows and provides near-quasi-phase-matching radiation conversion at a wavelength of 1053 nm into the second harmonic for the TE{sub 0} → TE{sub 1} waveguide process. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An amorphous phase formation at palladium / silicon oxide (Pd/SiO{sub x}) interface through electron irradiation - electronic excitation process

A Pd-Si amorphous phase was formed at a palladium/silicon oxide (Pd/SiO{sub x}) interface at room temperature by electron irradiation at acceleration voltages ranging between 25 kV and 200 kV. Solid-state amorphization was stimulated without the electron knock-on effects. The total dose required for the solid-state amorphization decreases with decreasing acceleration voltage. This is the first report on electron irradiation induced metallic amorphous formation caused by the electronic excitation at metal/silicon oxide interface.

36 MATERIALS SCIENCE↗

Si etching with reactive neutral beams of very low energy

A Si etching process has been investigated with reactive neutral beams (NBs) extracted using a low acceleration voltage of less than 100 V from CF{sub 4} and Ar mixed plasmas. The etched Si profile shows that the etching process is predominantly anisotropic. The reactive NB has a constant Si etching rate in the acceleration voltage range from 20 V to 80 V. It is considered that low-energy NBs can trigger Si etching because F radicals adsorb onto the Si surface and weaken Si–Si bonds. The etching rate per unit beam flux is 33 times higher than that with Ar NB. These results show that the low-energy reactive NB is useful for damage-free high speed Si etching.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental validation of the dual positive and negative ion beam acceleration in the plasma propulsion with electronegative gases thruster

The PEGASES (Plasma Propulsion with Electronegative Gases) thruster is a gridded ion thruster, where both positive and negative ions are accelerated to generate thrust. In this way, additional downstream neutralization by electrons is redundant. To achieve this, the thruster accelerates alternately positive and negative ions from an ion-ion plasma where the electron density is three orders of magnitude lower than the ion densities. This paper presents a first experimental study of the alternate acceleration in PEGASES, where SF{sub 6} is used as the working gas. Various electrostatic probes are used to investigate the source plasma potential and the energy, composition, and current of the extracted beams. We show here that the plasma potential control in such system is key parameter defining success of ion extraction and is sensitive to both parasitic electron current paths in the source region and deposition of sulphur containing dielectric films on the grids. In addition, large oscillations in the ion-ion plasma potential are found in the negative ion extraction phase. The oscillation occurs when the primary plasma approaches the grounded parts of the main core via sub-millimetres technological inputs. By controlling and suppressing the various undesired effects, we achieve perfect ion-ion plasma potential control with stable oscillation-free operation in the range of the available acceleration voltages (±350 V). The measured positive and negative ion currents in the beam are about 10 mA for each component at RF power of 100 W and non-optimized extraction system. Two different energy analyzers with and without magnetic electron suppression system are used to measure and compare the negative and positive ion and electron fluxes formed by the thruster. It is found that at alternate ion-ion extraction the positive and negative ion energy peaks are similar in areas and symmetrical in position with +/− ion energy corresponding to the amplitude of the applied acceleration voltage.

43 PARTICLE ACCELERATORS↗

JEFFERSON LAB 12 GEV CEBAF UPGRADE

The existing continuous electron beam accelerator facility (CEBAF) at Thomas Jefferson National Accelerator Facility (TJNAF) is a 5-pass, recirculating cw electron Linac operating at approx6 GeV and is devoted to basic research in nuclear physics. The 12 GeV CEBAF Upgrade is a $310 M project, sponsored by the Department of Energy (DOE) Office of Nuclear Physics, that will expand its research capabilities substantially by doubling the maximum energy and adding major new experimental apparatus. The project received construction approval in September 2008 and has started the major procurement process. The cryogenic aspects of the 12 GeV CEBAF Upgrade includes: doubling the accelerating voltages of the Linacs by adding ten new high-performance, superconducting radiofrequency (SRF) cryomodules (CMs) to the existing 42 1/4 cryomodules; doubling of the 2 K cryogenics plant; and the addition of eight superconducting magnets.

43 PARTICLE ACCELERATORS↗

Report on Design, Development, and Characterization of a Coaxial Resonator Based Single-gap Gridless Multiharmonic Buncher

The design of the multiharmonic buncher is determined by Facility for Rare Isotope Beam (FRIB) requirements. The buncher will bunch stable ion beams for injection into the FRIB RFQ to minimize the longitudinal beam emittance growth. The design beam energy is fixed at 12 keV/u while the beam charge state Q/A can vary from 1/3 to 1/7. The buncher operates at a fundamental frequency of 40.25 MHz. Two higher harmonics, 80.5 MHz and 120.75 MHz are used to linearize the voltage ramp. The typical accelerating voltage for a uranium beam, including the time-of-flight factor, is 1271 V, 456 V, and 150 V for 40.25 MHz, 80.5 MHz, and 120.75 MHz harmonics respectively. The voltage will be scaled with the charge state of an accelerated beam. The accelerated electrical beam current is expected to be approximately equal to 0.5 mA for all ion beams between oxygen and uranium.

43 PARTICLE ACCELERATORS↗

Freja Studies of the Current-Voltage Relation in Substorm-Related Events

Field-aligned currents and electrostatic potentials play important roles in the coupling between the magnetosphere and the ionosphere. If one assumes that the ionosphere-magnetosphere potential difference is mainly due to the mirror force, one can use the single particle adiabatic kinetic theory to describe the system. From this theory, a linear relationship j(sub II) = KV between field-aligned current density j(sub II) and potential drop V along the same field line can be derived, provided that the potential drop is not too large and not too small. With rare exceptions, observational tests of this relation have mainly concentrated on quiet magnetospheric situations, with acceleration voltages V approx. less than 5 kV. Here we use observations from the Freja satellite of precipitating auroral electrons at 1.700 km altitude to study substorm related events, with acceleration voltages up to 20 keV. The observations are found to be consistent with a linear current-voltage relation even i n these conditions, although with values of the field aligned K lower than previously reported (1-5 x 10(exp 11 S/sq m). This can be explained by lower densities and higher characteristic electron energies in the magnetospheric source region of the precipitating electrons. We analyze the data by three different methods, which are all found to be in general agreement. The results are in agreement with a previous study, where the spectra of precipitating electrons --were indirectly inferred by inversion of data from the EISCAT incoherent scatter radar, thereby validating the use of radar data for studies of auroral electrons. Comparisons with previous studies are made, emphasizing the dependence of the results on the type of auroral structure and magnetospheric conditions.

Olsson, A.↗

Features of the electrical conductivity of TlInSe{sub 2} under photoexcitation and X-ray excitation

The current–voltage characteristics of TlInSe{sub 2} crystals under photoexcitation and X-ray excitation are studied. The parameters of the trap, which are equal to N{sub t} = 5 × 10{sup 16} cm{sup –3}, n{sub t} = 4.5 × 10{sup 12} cm{sup –3}, and ΔE{sub t} = 0.42 eV, are calculated. The calculated values of N{sub t} and n{sub t} before and after X-ray excitation are equal to 3 × 10{sup 16} cm{sup –3} and 3.2 × 10{sup 12} cm{sup –3}, respectively. The dependences of the X-ray conductances on the radiation intensity are studied for TlInSe{sub 2} crystals at various accelerating voltages V{sub a} and it is determined that the X-ray conductance K{sub σ} decreases exponentially as the accelerating voltage V{sub a} and radiation dose increase.

36 MATERIALS SCIENCE↗

A compact high-resolution X-ray ion mobility spectrometer

For the ionization of gaseous samples, most ion mobility spectrometers employ radioactive ionization sources, e.g., containing {sup 63}Ni or {sup 3}H. Besides legal restrictions, radioactive materials have the disadvantage of a constant radiation with predetermined intensity. In this work, we replaced the {sup 3}H source of our previously described high-resolution ion mobility spectrometer with 75 mm drift tube length with a commercially available X-ray source. It is shown that the current configuration maintains the resolving power of R = 100 which was reported for the original setup containing a {sup 3}H source. The main advantage of an X-ray source is that the intensity of the radiation can be adjusted by varying its operating parameters, i.e., filament current and acceleration voltage. At the expense of reduced resolving power, the sensitivity of the setup can be increased by increasing the activity of the source. Therefore, the performance of the setup can be adjusted to the specific requirements of any application. To investigate the relation between operating parameters of the X-Ray source and the performance of the ion mobility spectrometer, parametric studies of filament current and acceleration voltage are performed and the influence on resolving power, peak height, and noise is analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of New Lithic Clasts in Lunar Breccia 14305 by Micro-CT and Micro-XRF Analysis

From 1969 to 1972, Apollo astronauts collected 382 kg of rocks, soils, and core samples from six locations on the surface of the Moon. The samples were initially characterized, largely by binocular examination, in a custom-built facility at Johnson Space Center (JSC), and the samples have been curated at JSC ever since. Despite over 40 years of study, demand for samples remains high (~500 subsamples per year are allocated to scientists around the world), particularly for plutonic (e.g., anorthosites, norites, etc.) and evolved (e.g., granites, KREEP basalts) lithologies. The reason for the prolonged interest is that as new scientists and new techniques examine the samples, our understanding of how the Moon, Earth, and other inner Solar System bodies formed and evolved continues to grow. Scientists continually clamor for new samples to test their emerging hypotheses. Although all of the large Apollo samples that are igneous rocks have been classified, many Apollo samples are complex polymict breccias that have previously yielded large (cm-sized) igneous clasts. In this work we present the initial efforts to use the non-destructive techniques of micro-computed tomography (micro-CT) and micro x-ray fluorescence (micro-XRF) to identify large lithic clasts in Apollo 14 polymict breccia sample 14305. The sample in this study is 14305,483, a 150 g slab of regolith breccia 14305 measuring 10x6x2 cm (Figure 1a). The sample was scanned at the University of Texas High-Resolution X-ray CT Facility on an Xradia MicroXCT scanner. Two adjacent overlapping volumes were acquired at 49.2 micrometer resolution and stitched together, resulting in 1766 slices. Each volume was acquired at 100 kV accelerating voltage and 98 mA beam current with a 1 mm CaF2 filter, with 2161 views gathered over 360deg at 3 seconds acquisition time per view. Micro-XRF analyses were done at Washington University in St. Louis, Missouri on an EDAX Orbis PC micro-XRF instrument. Multiple scans were made at 40 kV accelerating voltage, 800 mA beam current, 30 μm beam diameter, and a beam spacing of 30-120 micrometer. The micro-CT scan of 14305,483 (Figure 2) was able to identify several large lithic clasts (approx. 1 cm) within the interior of the slab. These clasts will be exposed by band-sawing or chipping of the slab, and their composition more fully characterized by subsequent micro-XRF analysis. In addition to lithic clasts, the micro-CT scans identified numerous mineral clasts, including many FeNi metal grains, as well as the prominent fractures within the slab. The micro-XRF analyses (Figure 1b,c) of the slab surfaces revealed the bulk chemical compositions (qualitative) of the different clast types observed. In particular, by looking at the ratios of major elements (e.g. Ca:Mg:Fe), differences among the many observed clast types are readily observed. Moreover, several clasts not apparent to the naked eye were revealed in the K:Al:Si ratio map. The scans are also able to identify small grains of Zr- and P-rich minerals (not shown), which could in turn yield important age dates for the samples.

Zeigler, Ryan A.↗

Surface Modification of Polymer Substrates by Oxygen Ion Irradiation

Oxygen cluster ions and/or monomer ions were used for the sputtering and the surface modification of polymers such as polycarbonate (PC) and polyethylene terephthalate (PET). For the case of oxygen cluster ion irradiation, the sputtered depth increased with increase of the acceleration voltage, and the sputtering yield was much larger than that by the monomer ion irradiation. The sputtered particles represented the polymer structure, which indicated that the bond scission by the cluster ion irradiation resulted in an ejection of monomer molecule through the intermolecular collision. On the other hand, for the oxygen monomer ion irradiation, the implanted depth increased with increase of the acceleration voltage, and the bond scission occurred at the deep region through the binary collision with the high energetic ions. Therefore, the sputtering yield for the polymer surfaces decreased, and the sputtering effect became very small. Furthermore, the simultaneous use of oxygen cluster and monomer ions was more effective for oxidation of the PET surfaces rather than the monomer ion irradiation or the cluster ion irradiation. As a result, the contact angle measurement showed that the wettability of the PET surfaces irradiated by the simultaneous use of oxygen cluster and monomer ions was much enhanced.

36 MATERIALS SCIENCE↗

Characteristics of microdomains and microdomain patterns recorded by electron beam irradiation on Y-cut LiNbO{sub 3} crystals

We present the results of investigations of planar domain patterns (isolated domains and domain gratings) fabricated by irradiation of the nonpolar Y-surface of LiNbO{sub 3} crystals by an electron beam (EB) incident normally onto the surface. The EB recorded domains were investigated using atomic force microscopy, confocal second harmonic generation microscopy, and chemical etching as an auxiliary method. The dependence of the domain characteristics on irradiation conditions (acceleration voltage U, EB current I, and irradiation time t{sub irr}) were determined. The length L{sub d} of both isolated domains and domain gratings along the polar axis Z grows linearly with t{sub irr} (at U, I = const) with no tending to saturation. The plots L{sub d}(t{sub irr}) obtained for U = 10 and 15 kV are practically identical, whereas the values of L{sub d} for U = 5 kV are essentially lower. The domain thickness T{sub d} along the Y-direction, i.e., the depth of the switched layer grows with acceleration voltage U. These results are discussed in terms of space-charge fields formation arising under EB irradiation of insulators. The linearity of L{sub d}(t{sub irr}) is accounted for by the frontal domain growth via the viscous friction law. The experimental dependence of T{sub d} on U supports the suggestion that the domain thickness is determined by the penetration depth R{sub e} of primary electrons, which in turn is governed by U. The difference in L{sub d}(t{sub irr}) plots for different U is accounted for by different electron emission σ. Indirect evidences of a defect structure modification in a thin surface layer with respect to the crystal bulk are obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advanced Surface Polishing For Accelerator Technology Using Ion Beams

A gas cluster ion beam (GCIB) technology was successfully applied to surface treatment of Cu, stainless steel, Ti, and Nb samples and to Nb rf-cavities by using accelerated cluster ion beams of Ar, O{sub 2} and combinations of them, with accelerating voltages up to 35 kV. DC field emission (dark current) measurements and electron microscopy were used to investigate metal surfaces treated by GCIB. The experimental results showed that GCIB technique can significantly reduce the number of field emitters and can change the structure of the Nb oxide layer on the surface. The RF tests of the GCIB-treated Nb rf-cavities showed improvement of the quality factor Q at 4.5 K. The superconducting gap was also enhanced by using the oxygen GCIB irradiation exposure.

36 MATERIALS SCIENCE↗

Constrained sheath optics for high thrust density, low specific impulse ion thrusters

The results of an experimental study showing that a contoured, fine wire mesh attached to the screen grid can be used to control the divergence characteristics of ion beamlets produced at low net-to-total accelerating voltage ratios are presented. The influence of free and constrained-sheath optics systems on beamlet divergence characteristics are found to be similar in the operating regime investigated, but it was found that constrained-sheath optics systems can be operated at higher perveance levels than free-sheath ones. The concept of a fine wire interference probe that can be used to study ion beamlet focusing behavior is introduced. This probe is used to demonstrate beamlet focusing to a diameter about one hundreth of the screen grid extraction aperture diameter. Additional testing is suggested to define an optimally contoured mesh that could yield well focused beamlets at net-to-total accelerating voltage ratios below about 0.1.

Wilbur, Paul J.↗

Runaway electrons and magnetic island confinement

The breakup of magnetic surfaces is a central feature of ITER planning for the avoidance of damage due to runaway electrons. Rapid thermal quenches, which lead to large accelerating voltages, are thought to be due to magnetic surface breakup. Impurity injection to avoid and to mitigate both halo and runaway electron currents utilizes massive gas injection or shattered pellets. The actual deposition is away from the plasma center, and the breakup of magnetic surfaces is thought to spread the effects of the impurities across the plasma cross section. The breakup of magnetic surfaces would prevent runaway electrons from reaching relativistic energies were it not for the persistence of non-intercepting flux tubes. These are tubes of magnetic field lines that do not intercept the walls. In simulations and in magnetic field models, non-intercepting flux tubes are found to persist near the magnetic axis and in the cores of magnetic islands even when a large scale magnetic surface breakup occurs. As long as a few magnetic surfaces reform before all of the non-intercepting flux tubes dissipate, energetic electrons confined and accelerated in these flux tubes can serve as the seed electrons for a transfer of the overall plasma current from thermal to relativistic carriers. The acceleration of electrons is particularly strong because of the sudden changes in the poloidal flux that naturally occur in a rapid magnetic relaxation. Furthermore, the physics of magnetic islands as non-intercepting flux tubes is studied. Expressions are derived for (1) the size of islands required to confine energetic runaway electrons, (2) the accelerating electric field in an island, (3) the increase or reduction in the size of an island by the runaway electron current, (4) the approximate magnitude of the runaway current in an island, and (5) the time scale for the evolution of an island.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Increased pattern transfer fidelity ZEP 520A during reactive ion etching through chemical modifications by additional dosing of the electron beam resist.

This article describes a postdevelopment, additional electron exposure to enhance the etch selectivity and improve pattern transfer fidelity of an electron beam resist, ZEP 520A, through chemical changes of the resist. After the critical features were patterned and developed, the resist was exposed at 5 kV accelerating voltage to a second dose of electrons ranging from 300 to 300,000 {micro}C/cm{sup 2}. The etch rate of the resist decreased by approximately 25% in a CHF{sub 3} and O{sub 2} plasma. More critically, the fidelity of the pattern transfer was improved. Infrared and Raman spectroscopies were used to characterize the resist before and after electron beam exposure for doses up to 3000 {micro}C/cm{sup 2}. The carbonyl bonding in the polymer showed significant changes after electron beam exposure that can be associated with improvement in the etch performance of this resist.

36 MATERIALS SCIENCE↗

Influence of ion source configuration and its operation parameters on the target sputtering and implantation process

In the work, investigation of the features and operation regimes of sputter enhanced ion-plasma source are presented. The source is based on the target sputtering with the dense plasma formed in the crossed electric and magnetic fields. It allows operation with noble or reactive gases at low pressure discharge regimes, and, the resulting ion beam is the mixture of ions from the working gas and sputtering target. Any conductive material, such as metals, alloys, or compounds, can be used as the sputtering target. Effectiveness of target sputtering process with the plasma was investigated dependently on the gun geometry, plasma parameters, and the target bias voltage. With the applied accelerating voltage from 0 to 20 kV, the source can be operated in regimes of thin film deposition, ion-beam mixing, and ion implantation. Multi-component ion beam implantation was applied to {alpha}-Fe, which leads to the surface hardness increasing from 2 GPa in the initial condition up to 3.5 GPa in case of combined N{sub 2}-C implantation. Projected range of the implanted elements is up to 20 nm with the implantation energy 20 keV that was obtained with XPS depth profiling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of the setup dependence of detector response functions for mega-voltage linear accelerators

Purpose: Accurate modeling of beam profiles is important for precise treatment planning dosimetry. Calculated beam profiles need to precisely replicate profiles measured during machine commissioning. Finite detector size introduces perturbations into the measured profiles, which, in turn, impact the resulting modeled profiles. The authors investigate a method for extracting the unperturbed beam profiles from those measured during linear accelerator commissioning. Methods: In-plane and cross-plane data were collected for an Elekta Synergy linac at 6 MV using ionization chambers of volume 0.01, 0.04, 0.13, and 0.65 cm{sup 3} and a diode of surface area 0.64 mm{sup 2}. The detectors were orientated with the stem perpendicular to the beam and pointing away from the gantry. Profiles were measured for a 10x10 cm{sup 2} field at depths ranging from 0.8 to 25.0 cm and SSDs from 90 to 110 cm. Shaping parameters of a Gaussian response function were obtained relative to the Edge detector. The Gaussian function was deconvolved from the measured ionization chamber data. The Edge detector profile was taken as an approximation to the true profile, to which deconvolved data were compared. Data were also collected with CC13 and Edge detectors for additional fields and energies on an Elekta Synergy, Varian Trilogy, and Siemens Oncor linear accelerator and response functions obtained. Response functions were compared as a function of depth, SSD, and detector scan direction. Variations in the shaping parameter were introduced and the effect on the resulting deconvolution profiles assessed. Results: Up to 10% setup dependence in the Gaussian shaping parameter occurred, for each detector for a particular plane. This translated to less than a {+-}0.7 mm variation in the 80%-20% penumbral width. For large volume ionization chambers such as the FC65 Farmer type, where the cavity length to diameter ratio is far from 1, the scan direction produced up to a 40% difference in the shaping parameter between in-plane and cross-plane measurements. This is primarily due to the directional difference in penumbral width measured by the FC65 chamber, which can more than double in profiles obtained with the detector stem parallel compared to perpendicular to the scan direction. For the more symmetric CC13 chamber the variation was only 3% between in-plane and cross-plane measurements. Conclusions: The authors have shown that the detector response varies with detector type, depth, SSD, and detector scan direction. In-plane vs cross-plane scanning can require calculation of a direction dependent response function. The effect of a 10% overall variation in the response function, for an ionization chamber, translates to a small deviation in the penumbra from that of the Edge detector measured profile when deconvolved. Due to the uncertainties introduced by deconvolution the Edge detector would be preferable in obtaining an approximation of the true profile, particularly for field sizes where the energy dependence of the diode can be neglected. However, an averaged response function could be utilized to provide a good approximation of the true profile for large ionization chambers and for larger fields for which diode detectors are not recommended.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗