Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable conductance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Thermal anomalies of the transmitter experiment package on the communications technology satellite

The causes of four temporary thermal-control-system malfunctions that gave rise to unexpected temperature excursions in the 12-gigahertz, 200-watt transmitter experiment package (TEP) on the Communications Technology Satellite were investigated. The TEP consists of a nominal 200-watt output stage tube (OST), a supporting power-processing system (PPS), and a variable-conductance heat-pipe system (VCHPS). The VCHPS, which uses three heat pipes to conduct heat from the body of the OST to a radiator fin, was designed to maintain the TEP at safe operating temperatures at all operating conditions. On four occasions during 1977, all near the spring and fall equinoxes, the OST body temperature and related temperatures displayed sudden, rapid, and unexpected rises above normal levels while the TEP was operating at essentially constant, normal conditions. The temperature excursions were terminated without TEP damage by reducing the radio frequency (RF) output power of the OST. Between the anomalies and since the fourth, the thermal control system has apparently functioned as designed. The results indicate the most probable cause of the temperature anomalies is depriming of the arteries in the variable-conductance heat pipes. A mode was identified in which the TEP, as presently configured, may operate with stable temperatures and with minimum change in performance level.

Alexovich, R. E.↗

Thermal Radiator for CO2 Deposition in Deep Space Transit (FY21 XHab Final Report - University of North Texas)

This UNT Senior design team was tasked by NASA to develop a variable conductance thermal radiator prototype for CO2 deposition for deep space transit. NASA selects university teams every year to partake in the X-HAB Academic Innovation Challenge, with this year’s number of teams being six. Air Revitalization is a crucial system for any space travel, be it for Low Earth Orbit, such as the International Space Station, or for deep space transit. Current systems, such as the Carbon Dioxide Removal Apparatus aboard the ISS, require upkeep and maintenance, which cannot be done on long distance space missions. For the past several years, NASA has done research on Cryogenic systems for Carbon Dioxide removal. These systems operate on the fact that Carbon Dioxide freezes at a higher temperature than Oxygen and Nitrogen, so Carbon Dioxide can be frozen out of the cabin atmosphere without the use of filters, which degrade over time. To cool the cabin air down to a temperature where Carbon Dioxide freezes, Stirling cryocoolers have been used, which have shown promise in the hope of Carbon Dioxide deposition for Cabin Air Revitalization. Cryogenic systems are much more reliable but require significant energy input to operate. Physical systems, such as radiators, have generally not been used for this task, as there is a need to be able to “turn off” the rejection of heat to allow the frozen carbon dioxide to be collected. However, with working fluids pumped through a physical radiator, that aspect of operation can be achieved. The goal of this challenge is to determine the effectiveness of a variable conductance thermal radiator that can reject heat to deep space, without the use of a dedicated cryocooler to remove energy from the cabin air. The proposed design uses piping, hot and cold working fluids, and non-condensable gas to absorbl heat from the cabin air on one side of the radiator and reject the heat to deep space by means of thermal radiation. As well, the system will allow for the recovery of deposited Carbon Dioxide. The UNT X-HAB 2021 team will create a model radiator and test its performance with simulated heat sources and sinks and extrapolate those data points to analyze for real world conditions.

Travis Seaver↗

Thermal Vacuum Testing of a Novel Loop Heat Pipe Design for the Swift BAT Instrument

An advanced thermal control system for the Burst Alert Telescope on the Swift satellite has been designed and an engineering test unit (ETU) has been built and tested in a thermal vacuum chamber. The ETU assembly consists of a propylene loop heat pipe, two constant conductance heat pipes, a variable conductance heat pipe (VCHP), which is used for rough temperature control of the system, and a radiator. The entire assembly was tested in a thermal vacuum chamber at NASA/GSFC in early 2002. Tests were performed with thermal mass to represent the instrument and with electrical resistance heaters providing the heat to be transferred. Start-up and heat transfer of over 300 W was demonstrated with both steady and variable condenser sink temperatures. Radiator sink temperatures ranged from a high of approximately 273 K, to a low of approximately 83 K, and the system was held at a constant operating temperature of 278 K throughout most of the testing. A novel LHP temperature control methodology using both temperature-controlled electrical resistance heaters and a small VCHP was demonstrated. This paper describes the system and the tests performed and includes a discussion of the test results.

Ottenstein, Laura↗

Development of a jet pump-assisted arterial heat pipe

The development of a jet pump assisted arterial heat pipe is described. The concept utilizes a built-in capillary driven jet pump to remove vapor and gas from the artery and to prime it. The continuous pumping action also prevents depriming during operation of the heat pipe. The concept is applicable to fixed conductance and gas loaded variable conductance heat pipes. A theoretical model for the jet pump assisted arterial heat pipe is presented. The model was used to design a prototype for laboratory demonstration. The 1.2 m long heat pipe was designed to transport 500 watts and to prime at an adverse elevation of up to 1.3 cm. The test results were in good agreement with the theoretical predictions. The heat pipe carried as much as 540 watts and was able to prime up to 1.9 cm. Introduction of a considerable amount of noncondensible gas had no adverse effect on the priming capability.

Bienert, W. B.↗

Effect of variable thermal conductivity on isotherms in Bridgman growth

A change in thermal conductivity associated with melting or solidification can have a profound influence on the isotherms near the solidification interface if the material is being directionally solidified in an ampoule whose walls carry a substantial portion of the heat. This analysis was prompted by a recent discovery that the thermal conductivity of Hg(1-x)CD(x)Te increased dramatically as the material is heated above the solidus curve. An illustrative example is shown in which the sample is approximated as an infinite cylinder with constant but diffferent thermal properties in the solid and melt. The boundary conditions are fixed on the surface by a conductive ampoule in a two-zone Bridgman furnace with an adiabatic region separating the two zones. The effect of the adiabatic zone in this case is to intensify the curvature of the interface rather than to lessen it.

Naumann, R. J.↗

In-Flight Thermal Performance of the OCO-2 Instrument

The Orbiting Carbon Observatory-2 (OCO-2), launched on July 2, 2014, continues to operate nominally after successfully completing its primary mission of two years in space. It is hoped that, following a Senior Review and proposal phase, NASA will fund a two year extended mission, which would start in June 2017. The thermal design provides three temperature zones required by the instrument, specifically at 120 K, 267 K and 297 K. A single-stage pulse tube cryocooler provides refrigeration to three focal plane arrays to 120 K, via a high conductance flexible thermal strap. A variable conductance heat pipe (VCHP) based heat rejection system transports waste heat from the instrument, located inside the spacecraft, to the space-viewing radiators, providing tight temperature control of the spectrometer optics to 267 K, and maintains the electronics and cryocooler at 297 K. Soon after entering the A-Train on August 3, 2014, the optics and focal planes were cooled to their operating temperatures. Ice contamination of the cryogenic surfaces led to increased cryocooler loads and drove the need for two focal plane decontamination cycles between September 2014 and October 2014. A decrease in the radiometric gain of the O2 A-Band channel led to five additional focal plane decontamination cycles, between January 2015 and February 2017, and is now the primary driver of decontamination cycles. This paper provides a general overview of the thermal and cryogenic system design and reviews the inflight thermal performance for the mission.

Na-Nakornpanom, Arthur↗

Analysis and design of a flat central finned-tube radiator

Computer program based on fixed conductance parameter yields minimum weight design. Second program employs variable conductance parameter and variable ratio of fin length to tube outside radius, and is used for radiator designs with geometric limitations. Major outputs of the two programs are given.

Auer, B. M.↗

Alkali Metal Backup Cooling for Stirling Systems - Experimental Results

In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor. In a previous NASA SBIR Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for Stirling RPS. The operation of these VCHPs was demonstrated using Stirling heater head simulators and GPHS simulators. In the most recent effort, a sodium VCHP with a stainless steel envelope was designed, fabricated and tested at NASA Glenn Research Center (GRC) with a Stirling convertor for two concepts; one for the Advanced Stirling Radioisotope Generator (ASRG) back up cooling system and one for the Long-lived Venus Lander thermal management system. The VCHP is designed to activate and remove heat from the stopped convertor at a 19 degC temperature increase from the nominal vapor temperature. The 19 degC temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the Multi-Layer Insulation (MLI). In addition, the same backup cooling system can be applied to the Stirling convertor used for the refrigeration system of the Long-lived Venus Lander. The VCHP will allow the refrigeration system to: 1) rest during transit at a lower temperature than nominal; 2) pre-cool the modules to an even lower temperature before the entry in Venus atmosphere; 3) work at nominal temperature on Venus surface; 4) briefly stop multiple times on the Venus surface to allow scientific measurements. This paper presents the experimental results from integrating the VCHP with an operating Stirling convertor and describes the methodology used to achieve their successful combined operation.

Stirling Convertor↗

Investigation of micro-gravity effects on heat pipe thermal performance and working fluid behavior, phase B

The purpose of this experiment is to develop an in-depth understanding of the behavior of heat pipes in space. Both fixed conductance heat pipes (FCHPs) with axial grooves and variable conductance heat pipes (VCHPs) with porous wicks will be investigated. This understanding will be applied to the development of improved performance heat pipes subjected to various accelerations in space, including those encountered on a lunar base or Mars mission. More efficient, reliable, and lighter weight spacecraft thermal control systems should result from these investigations.

Gier, K. D.↗

Thermal design and test of a high power spacecraft transponder platform

The high power transponder subsystem on board the Communications Technology Satellite (CTS) requires some unique thermal control techniques to maintain the required temperature limits throughout all mission phases. The transponder subsystem includes redundant 20-W output travelling wave tubes and a single 200-W output TWT with highly concentrated thermal dissipations of 70 W and 143 W, respectively. A thermal control system which maintains all components within the required temperature ranges has been designed and verified in thermal balance testing. Included in the design are second surface quartz mirrors on an aluminum honeycomb platform, high thermal conductivity aluminum doubler plates, commandable thermal control heaters and a Variable Conductance Heat Pipe System (VCHPS).

Stipandic, E. A.↗

Thermal Technology Development Activities at the Goddard Space Flight Center: 2001

Activities include the development of two phase systems which are composed of 1) heat pipes and variable conductance heat pipes, 2)capillary pumped loops, 3) loop heat pipes, 4) vapor compression systems (heat pumps), 5) phase change materials. Also in the development phase are variable emittance surfaces, advanced coatings, high conductivity materials, and electrohydrodynamic (EHD) thermal control systems.

Butler, Dan↗

Two-Phase Thermal Switching System for a Small, Extended Duration Lunar Surface Science Platform

This paper describes a novel thermal control system for the Warm Electronics Box (WEB) on board a small lunar surface lander intended to support science activities anywhere on the lunar surface for an extended duration of up to 6 years. Virtually all lander electronics, which collectively dissipate about 60 W in the reference mission, are contained within the WEB. These devices must be maintained below 323 K (with a goal of 303 K) during the nearly 15-earth-day lunar day, when surface temperatures can reach 390K, and above 263 K during the nearly 15-earth-day lunar night, when surface temperatures can reach 100K. Because of the large temperature swing from lunar day-to-night, a novel thermal switching system was required that would be able to provide high conductance from WEB to radiator(s) during the hot lunar day and low (or negligible) conductance during the cold lunar night. The concept that was developed consists of ammonia variable conductance heat pipes (VCHPs) to collect heat from WEB components and a polymer wick propylene loop heat pipe (LHP) to transport the collected heat to the radiator(s). The VCHPs autonomously maximize transport when the WEB is warm and autonomously shut down when the WEB gets cold. The LHP autonomously shuts down when the VCHPs shut down. When the environment transitions from lunar night to day, the VCHPs and LHP autonomously turn back on. Out of 26 analyzed systems, this novel arrangement was able to best achieve the combined goals of zero control power, autonomous operation, long life, low complexity, low T, and landed tilt tolerance.

Bugby, David C.↗

The OAO heat pipes - 8 1/2 years of flight data

Heat pipe performance data taken during the 8 1/2 years of flight of the OAO-C (Copernicus) spacecraft are presented. Three fixed conductance heat pipes (FCHP), each with different wicking concepts (axial groove, pedestal artery, and self-priming spiral artery), and one variable conductance heat pipe (VCHP) are onboard. Aluminum tubes (1/2 in. diameter) rolled into a 48 in. loop containing ultra high purity ammonia as the heat transfer fluid comprise all FCHP, whose purpose is to circumferentially isothermalize the central tube housing the telescope. The VCHP is a hot, non-wicked reservoir concept including a composite artery and methanol heat transfer fluid, and is used to maintain the temperature of the onboard processor. Flight thermal data analysis reveals that no degradation in performance occurred since launch and agrees well with pre-flight data; the onboard processor still shows an offset in control range of 4 F, and the pipes perform the same after 8 1/2 years in orbit.

Harwell, W.↗

Long term performance of the advanced thermal control flight experiment

The Advanced Thermal Control Flight Experiment (ATFE) is providing the first zero-g flight data for the performance of a thermal diode heat pipe and an electrical Feedback Controlled Heat Pipe (FCHP). The temperature stability derived from the melting and freezing of octadecane is also being evaluated in this experiment. Flight data for the different operational modes are compared to ground test data, and the performance of the individual components is analyzed. Also, the ATFE's long term behavior from launch through September 30, 1975, is evaluated. The temperature control capability of a thermal diode, phase change material, and FCHP was demonstrated over more than 500 days of flight operation and each of these components should be considered in future applications. Both the diode and FCHP transport more than 20 W in the normal and passive modes during maximum conditions. Up to 30 W has been carried by the FCHP when the auxiliary heater is applied. The "OFF-conductance" of the diode has improved substantially in flight. A 1.4 W decrease in backflow has been realized by more complete blockage. The variable conductance behavior of the FCHP is essentially unchanged with time and relative to ground tests. Degradation of the radiator and reservoir surfaces have resulted in a partial loss of control by the FCHP during normal mode operation; however, manual control at an elevated set point has demonstrated the FCHP's ability to provide regulated temperature control to within + or - 2 C. The same pipe when operated as a passive VCHP controlled at 35 + or - 10 C with the same test conditions.

Brennan, P. J.↗

Performance of the 12 GHz, 200 watt Transmitter Experiment Package for the Hermes Satellite

Performance characteristics from on-orbit tests of the Transmitter Experiment Package (TEP) for the Hermes Satellite are presented. The tests were conducted from February 8, 1976 through August 8, 1977. The TEP consists of a Power Processing System (PPS), an Output Stage Tube (OST) and a Variable Conductance Heat Pipe System (VCHPS), all of which are described. The OST is a coupled-cavity traveling wave tube with a multistage depressed collector and a stepped velocity-tapered slow wave structure for efficiency enhancement. It has an RF output power of 233 W and overall efficiency of 50.75% at a center band frequency of 12.080 GHz. The PPS provides the required operating voltages, regulation, control and protection for the OST. The VCHPS consists of a fin radiator and three dual-artery stainless steel heat pipes using methanol and a mixture of inert gases. Test results presented include efficiencies, RF output power and body current. A discussion of thermal anomalies which occurred is presented.

Alexovich, R. E.↗

A variable multi-step method for transient heat conduction

A variable explicit time integration algorithm is developed for unsteady diffusion problems. The algorithm uses nodal partitioning and allows the nodal groups to be updated with different time steps. The stability of the algorithm is analyzed using energy methods and critical time steps are found in terms of element eigenvalues with no restrictions on element types. Several numerical examples are given to illustrate the accuracy of the method.

Smolinski, Patrick↗

Heat pipe heat rejection system

A prototype of a battery heat rejection system was developed which uses heat pipes for more efficient heat removal and for temperature control of the cells. The package consists of five thermal mock-ups of 100 amp-hr prismatic cells. Highly conductive spacers fabricated from honeycomb panels into which heat pipes are embedded transport the heat generated by the cells to the edge of the battery. From there it can be either rejected directly to a cold plate or the heat flow can be controlled by means of two variable conductance heat pipes. The thermal resistance between the interior of the cells and the directly attached cold plate was measured to be 0.08 F/Watt for the 5-cell battery. Compared to a conductive aluminum spacer of equal weight the honeycomb/heat pipe spacer has approximately one-fifth of the thermal resistance. In addition, the honeycomb/heat pipe spacer virtually eliminates temperature gradients along the cells.

Kroliczek, E. J.↗

Investigation of Freeze and Thaw Cycles of a Gas-Charged Heat Pipe

The traditional constant conductance heat pipes (CCHPs) currently used on most spacecraft run the risk of bursting the pipe when the working fluid is frozen and later thawed. One method to avoid pipe bursting is to use a gas-charged heat pipe (GCHP) that can sustain repeated freeze/thaw cycles. The construction of the GCHP is similar to that of the traditional CCHP except that a small amount of non-condensable gas (NCG) is introduced and a small length is added to the CCHP condenser to serve as the NCG reservoir. During the normal operation, the NCG is mostly confined to the reservoir, and the GCHP functions as a passive variable conductance heat pipe (VCHP). When the liquid begins to freeze in the condenser section, the NCG will expand to fill the central core of the heat pipe, and ice will be formed only in the grooves located on the inner surface of the heat pipe in a controlled fashion. The ice will not bridge the diameter of the heat pipe, thus avoiding the risk of pipe bursting during freeze/thaw cycles. A GCHP using ammonia as the working fluid was fabricated and then tested inside a thermal vacuum chamber. The GCHP demonstrated a heat transport capability of more than 200W at 298K as designed. Twenty-seven freeze/thaw cycles were conducted under various conditions where the evaporator temperature ranged from 163K to 253K and the condenser/reservoir temperatures ranged from 123K to 173K. In all tests, the GCHP restarted without any problem with heat loads between 10W and 100W. No performance degradation was noticed after 27 freeze/thaw cycles. The ability of the GCHP to sustain repeated freeze/thaw cycles was thus successfully demonstrated.

Ku, Jentung↗