Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vapor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development of electrostatic precipitator (ESP) technology to remove elemental mercury vapor, HG(0)

The presence of mercury vapor or other forms of mercury presents issues with worker safety, decommissioning facilities, and environmental impacts. As such, it is desired to develop a strategy to either remove or reduce mercury levels in Oak Ridge’s Y-12 Complex facilities. A testing methodology was developed to evaluate electrostatic precipitator technology for removal of mercury vapor. This methodology involved supplying mercury vapor-containing air to the ESP device by flowing air through a column containing alternating layers of sand and liquid mercury droplets. Initial attempts at quantifying the efficacy of the ESP device in removing mercury vapor were plagued with difficulties in controlling the flow of mercury into the ESP device due to poor performance of the generator column and the contamination of these experiments with mercury from an unknown source. These issues were resolved by creating a new generator column with slower air velocity and higher surface area of liquid mercury, along with moving the air intake for the ESP device to outside of the chemical hood in which testing took place. This resulted in a steady, quantified flow of mercury vapor from the generator column and no observation of unintended mercury sources. A final test of the ESP device under these controlled conditions showed that for a certain amount of time (on the order of 20-30 minutes) mercury concentrations were reduced by approximately 33 - 67% of the inlet concentration. However, episodic releases or pulses of mercury observed only at the outlet indicated that the mercury accumulated in the ESP device is periodically expelled. As a result, it was not deemed to be an efficient strategy for the removal of elemental mercury vapor.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Permeation Properties of Disordered Metal-Organic Framework Membranes Made by Vapor Phase Ligand Treatment

Zeolitic imidazolate frameworks (ZIFs) are nanoporous molecular sieves offering exciting opportunities for membrane- and adsorption-based gas separations. The Tsapatsis group developed an all-vapor-phase ligand induced permselectivation (LIPS) method for the fabrication of ZIF nanocomposite membranes. The LIPS method consists of a combination of atomic layer deposition of a dense oxide inside the mesopores of a porous support followed by transformation of the dense oxide deposit to nanoporous ZIF by exposure to sublimated vapors of an imidazolate ligand. It enables the formation of thin nanocomposite films consisting of ZIF deposited inside pores with diameters smaller than 10 nm. Vapor-phase conversion of the impermeable ZnO to ZIF increases flux of certain gases more than others. Vapor phase linker/ligand treatment (VPLT) can further modify the properties of LIPS and other membranes. The combination of LIPS with VPLT provides an all-vapor methodology for making and modifying ZIF membranes with the ability to control the ZIF deposit composition and the level of confinement in a variety of mesoporous supports. The propylene/propane separation performance of LIPS/VPLT ZIF membranes confined (entirely or partially) inside mesopores is remarkably superior to that of most conventional ZIF membranes consisting of unconfined (deposited on the external surface of porous supports) polycrystalline films. The accomplishments of this award are: (i) understanding of the LIPS process using mathematical models of atomic layer deposition (ALD), (ii) development of surface modification methods (vapor, e-beam, plasma, and X-ray treatments) to tune permeation properties, (iii) microstructural control of ZIF-8 films using ALD (support modification, direct ALD, and by use of in situ permeability monitoring), (iv) molecular simulations, and (v) thin film characterization and adsorption measurements using spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hail tower for gas-vapor separations

A device and process for removing vapors from a gas is disclosed. A tower is provided. Sub-cooled pellets are distributed by the solids distributor across a horizontal cross-section of the tower. A process gas, comprising a product vapor, passes through the gas inlet. The product vapor and the sub-cooled pellets comprise the same material. The product vapor and the sub-cooled pellets agglomerate as the product vapor desublimates onto the sub-cooled pellets, forming product pellets and a vapor-depleted gas. A crushing device, a screening device, and a solids heat exchanger are provided. A portion of the product pellets are recycled as sub-cooled pellets to the solids distributor by crushing and screening the portion of the product pellets to the size distribution of the sub-cooled pellets and cooling the portion of the product pellets to produce the sub-cooled pellets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ratiometric vapor sensor

A ratiometric vapor sensor is described that includes a first sensor and a second sensor. The first sensor includes a first semiconductor component comprising a vapor-sensitive semiconducting organic compound, while the second sensor includes a second semiconductor component comprising a modified vapor-sensitive semiconducting organic compound including a modifying organic group. The ratiometric vapor sensor can be used to detect the presence of a vapor such as nitrogen dioxide, and determine the concentration of the vapor by comparing the outputs of electrodes connected to the first and second sensor.

47 OTHER INSTRUMENTATION↗

Numerical Analysis of Water Harvesting from Saturated Vapor with the Electrospray Water Droplet Injection in The Solar-Driven Desalination Applications

Solar-driven seawater desalination systems provide freshwater through environmentally friendly and carbon-neutral processes. Air humidification and dehumidification desalination (HDD) systems extract water directly from moist air. This paper focuses on a new solar-driven seawater desalination system that shares some common traits with HDD systems but in which the air is eliminated from the process. Seawater is vaporized by solar thermal radiation in high-performance solar panels. Water vapor flows to a new electro-condensation chamber and passes through a series of electrosprays, which inject small nuclei of freshwater droplets into the vapor clouds. Here, due to dielectrophoresis and electrohydrodynamic flows, the vapor molecules are captured by the charged droplets, and vapor is condensed at the droplet surface. The water vapor condensation was modeled by using the multiphase flow numerical model. The CFD model, which was also experimentally validated, used SprayFoam solver modules available in the Open FOAM® CFD open-source software. In preliminary results, 802 grams/(hr-m2) (grams per hour per unit area) of water was harvested directly from moist air at 24C and 90% relative humidity. The simulation results indicated that freshwater productivity could increase up to 4,000 grams/(hr-m2) for fully saturated air conditions. This represents about 5 times the water productivity rate of current conventional HDD systems today. In addition, energy consumption could be reduced by 80 percent compared to conventional HDD systems.

Electrospray, electro-condensation, solar, droplet↗

Thermodynamic Model and Initial Experimental Investigation of Air Dehumidification through Electrically Charged Vapor Capturing Electrostatic Droplets

The removal of water vapor from the air to reduce relative humidity is a well known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation with the goal to reduce the energy consumption associated with dehumidification. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. In this thesis, a broad theoretical investigation to study the electrostatically enhanced condensation processes was carried out. These processes consist of the use of highly charged particles, preferably highly charged water droplets to attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. The electrical charge promotes the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation on curved surfaces and, consequently, the equilibrium between evaporation and condensation is shifted towards condensation. This investigation resulted in the development of a thermodynamics model, which was able to predict an effective size range of the charged droplets for optimal dehumidification, under ideal conditions. The range resulted in about 2 to 4 m in diameter, while the electrical charge was kept to the maximum limit predicted by the Rayleigh model. A sensitivity analysis on the variation of the size and the charge of the charged droplets was also performed. In terms of dehumidification rates, when six electrospray heads, i.e. the maximum number of heads tested in the experimental campaign, were considered, the model predicted very limited rates, way lower than the target of this research, i.e. a dehumidification rate in terms of relative humidity of 5 % with an air flow rate of 5 cfm. While ways to increase this rate existed, their implementation proved difficult for this initial investigation. According to the requirements predicted by the model, the use of electrosprays appeared the most suitable solution for the production of small but highly charged droplets. The electrospray features and operational modes were studied in detail and an electrospray assembly was designed to be tested in this initial experimental investigation. For this initial investigation, an experimental system was designed and built to validate the thermodynamics model and with the goal to achieve a dehumidification rate of 5 % in terms of relative humidity with an air flow rate of 5 cfm. The experimental system consisted of a wind tunnel test apparatus, dew point sensors, thermocouples for temperature measurements, pressure sensors and other devices. The experimental system was equipped with a computerized data acquisition and storage system. The system was suitable to evaluate the air water content differential before and after the test section where the electrospray heads were installed. The air water content differential was evaluated in terms of the ∆ω/ω_1 ratio, to eliminate the dependence on the dry bulb temperature along the test apparatus. This work presented initial experimental data for electrostatically enhanced dehumidification processes. Working parameters, such as air and water flow rates, high voltage potentials and polarity, deionized water types with different electrical conductivity, were varied to find the best combination for an improved dehumidification. With the set up used and the conditions considered, it was never possible to achieve a 5 % dehumidification rate with 5 cfm. In general, the dehumidification rate was always limited and lower than 1 % for all the air flow rates considered and mainly within the uncertainty of the dew point sensors. These results confirmed the already limited predictions of the thermodynamics model, for ideal conditions and the interesting and promising results obtained in some experimental investigations available in the open literature were not achievable in this thesis. The more probable reasons were the higher air flow rates considered and the complete absence of the use of cooling power, which was mainly implemented to facilitate the vapor condensation.

Morcelli, Stefano↗

Developments on two lithium vapor-box linear test-stand experiments

The lithium vapor-box divertor is a possible fusion power exhaust solution.It uses condensation pumping to create a gradient of vapor density in a divertor slot; this should allow a stable detachment front without active feedback.As initial explorations of the concept, two test stands which take the form of three connected cylindrical stainless steel boxes are being developed: one without plasma at PPPL, to test models of lithium evaporation and flow; and one for the linear plasma device Magnum-PSI (at DIFFER in Eindhoven, The Netherlands) to test the ability of a lithium vapor cloud to induce volumetric detachment and redistribute the plasma power.The first experiment uses boxes with diameters of 6 cm, joined by apertures with diameters of 2.2 cm. Up to 1 g of Li is placed in one box, which is heated to up to 600 degrees C. The Li evaporates, then flows to and condenses in the two other, cooler boxes over several minutes. The quantity of Li transported is assessed by weighing the boxes before and after the heating cycle, and is compared to the quantity predicted to flow for the box at its measured temperature using a Direct Simulation Monte Carlo code, SPARTA. With good experimental conditions, the two values agree to within 15%.The experiment on Magnum-PSI is in the conceptual design stage.The design is assessed by simulations using the code B2.5-Eunomia.They show that when the hydrogen-ion plasma beam, with n_e = 4e20 per cubic meter, T_e = 1.5 eV, and r = 1 cm, is passed through a 16 cm long, 12 Pa, 625 degree C Li vapor cloud, the plasma heat flux and pressure on the target are significantly reduced compared to the case without Li.With the Li present, the plasma is cooled by excitation of Li neutrals followed by radiation until it volumetrically recombines, lowering the heat flux from 3.7 MW/m^2 to 0.13 MW/m^2, and the pressure is reduced by 93%, largely by collisions of hydrogen ions with neutral Li.

divertor↗

Current Status on the Manufacturing of Nanomaterials for Proton Exchange Membrane Energy Systems by Vapor-Based Processes

Development of novel technologies for catalyst synthesis and membrane electrode assembly (MEA) fabrication is of primary importance for further improvement of the performance and economics of proton exchange membrane fuel cells (PEMFCs) and proton exchange membrane water electrolyzers (PEMWEs). While the traditional manufacturing methods are time-consuming, energy intensive, and require many processing steps, the new vapor-based methods provide many benefits including the development of improved catalysts and catalyst supports, deposition of uniform thin films, reduction of catalyst loading, and minimizing the number of manufacturing steps. Recent publications in the field identified spray pyrolysis, reactive spray deposition technology, chemical vapor deposition, and atomic layer deposition as advanced vapor-based catalyst synthesis and deposition methods used for fabrication of MEAs for PEMFCs and PEMWEs. Here, the MEAs fabricated via vapor-based processes have shown significant performance improvements in comparison to the state-of-the-art MEAs, which are attributed to better catalyst distribution, improved catalyst supports, and controlled, uniform catalyst layer microstructures. This review provides an overview of the vapor-based synthesis and deposition methods currently being used for the development of PEM-based devices. The advantages and disadvantages of these methods are critically compared and discussed while the outlook for future development is provided.

25 ENERGY STORAGE↗

Silicate Melting and Vaporization During Rocky Planet Formation

Collisions that induce melting and vaporization can have a substantial effect on the thermal and geochemical evolution of planets. However, the thermodynamics of major minerals are not well known at the extreme conditions attained during planet formation.We obtained new data at the Sandia Z Machine and use published thermodynamic data for the major mineral forsterite (Mg 2 SiO 4 ) to calculate the specific entropy in the liquid region of the principal Hugoniot.We use our calculated specific entropy of shocked forsterite, and revised entropies for shocked silica, to determine the critical impact velocities for melting or vaporization upon decompression from the shocked state to 1 bar and the triple points, which are near the pressures of the solar nebula.We also demonstrate the importance of the initial temperature on the criteria for vaporization. Applying these results to N-body simulations of terrestrial planet formation, we find that up to 20% to 40% of the total system mass is processed through collisions with velocities that exceed the criteria for incipient vaporization at the triple point. Vaporizing collisions between small bodies are an important component of terrestrial planet formation.

58 GEOSCIENCES↗

Temperature and Density on the Forsterite Liquid‐Vapor Phase Boundary

Abstract The physical processes during planet formation span a large range of pressures and temperatures. Giant impacts, such as the one that formed the Moon, achieve peak pressures of 100s of GPa. The peak shock states generate sufficient entropy such that subsequent decompression to low pressures intersects the liquid‐vapor phase boundary. The entire shock‐and‐release thermodynamic path must be calculated accurately in order to predict the post‐impact structures of planetary bodies. Forsterite (Mg 2 SiO 4 ) is a commonly used mineral to represent the mantles of differentiated bodies in hydrocode models of planetary collisions. Here, we performed shock experiments on the Sandia Z Machine to obtain the density and temperature of the liquid branch of the liquid‐vapor phase boundary of forsterite. This work is combined with previous work constraining pressure, density, temperature, and entropy of the forsterite principal Hugoniot. We find that the vapor curves in previous forsterite equation of state models used in giant impacts vary substantially from our experimental results, and we compare our results to a recently updated equation of state. We have also found that due to under‐predicted entropy production on the principal Hugoniot and elevated temperatures of the liquid vapor phase boundary of these past models, past impact studies may have underestimated vapor production. Furthermore, our results provide experimental support to the idea that giant impacts can transform much of the mantles of rocky planets into supercritical fluids.

58 GEOSCIENCES↗

FX Hg Fogging Fixative Deployment for Mercury Vapor Suppression

Idaho National Laboratory’s (INL) FX Hg fixative solution was deployed at the Y-12 Complex in Oak Ridge, Tennessee to support disposal of mercury-contaminated metal debris. The fixative was dispensed via fogging. Fogging infiltrates non-line-of-sight areas improving fixative coating on complex geometries such as debris piles. FX Hg is the mercury vapor controlling derivative of INL’s FX2 fixative. FX2 was jointly developed with the National Nuclear Laboratory of the United Kingdom, and INL developed the FX Hg derivative to suppress mercury vapor generation. The Y-12 deployment was performed in concert with cleanup contractor UCOR. A dumpster filled with debris was fogged with FX Hg. The material was acceptable as municipal landfill waste, save for the mercury vapor levels measured. If the mercury vapor generation rate could be sufficiently reduced, disposal costs for this waste would be dramatically reduced. FX Hg had previously proven effective at significantly reducing mercury vapor generation rates in bench scale testing at INL. This deployment was the first field scale deployment of the method. Efficacy results were underwhelming, but interpretation of the outcome is complicated by a paucity of hard data. Methods for improving data capture and analysis are analyzed. Operational difficulties associated with scaling the process up and process improvements for future deployments are discussed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FX Hg Fogging Fixative Deployment for Mercury Vapor Suppression - 20410

Idaho National Laboratory's (INL) FX Hg fixative solution was deployed at the Y-12 National Security Complex in Oak Ridge, Tennessee to support disposal of mercury-contaminated metal debris. The fixative was dispensed via fogging. Fogging infiltrates non-line-of-sight areas improving fixative coating on complex geometries such as debris piles. FX Hg is the mercury vapor controlling derivative of INL's FX2 fixative. FX2 was jointly developed with the National Nuclear Laboratory of the United Kingdom, and INL developed the FX Hg derivative to suppress mercury vapor generation. The Y-12 deployment was performed in concert with UCOR (URS CH2M Oak Ridge), the cleanup contractor for Y-12. A dumpster filled with debris was fogged with FX Hg. The debris was acceptable as municipal landfill waste, save for the mercury vapor levels measured. If the mercury vapor generation rate could be sufficiently reduced, disposal costs for this waste would be dramatically reduced. FX Hg had previously proven effective at significantly reducing mercury vapor generation rates in bench scale testing at INL. This deployment was the first field-scale deployment of the method. Efficacy results were underwhelming, but interpretation of the outcome is complicated by a paucity of hard data. Methods for improving data capture and analysis are analyzed. Operational difficulties associated with scaling up the process and process improvements for future deployments are discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reducing Cost of Chlorinated Volatile Organic Compound Remediation by Transitioning from Active to Passive Soil Vapor Extraction - 20157

Areas of high chlorinated volatile organic compound (cVOC) contamination at the Savannah River Site (SRS) have been undergoing remediation via soil vapor extraction, sometimes coupled with thermal treatments to enhance extraction rates. These active systems are effective in removing large amounts of contaminant mass from the subsurface and mitigating the impacts to groundwater. However, as extraction rates decline, costs must be evaluated with respect to the benefit of continued active operation. A decision framework for identifying conditions when a transition to a more passive remediation is appropriate has been developed with state and federal regulatory agencies. Two remediation areas have recently been transitioned from active soil vapor extraction (ASVE) to passive soil vapor extraction (PSVE) at the SRS. Performance evaluation goals including plume stabilization, overall mass removal trends, environmental sustainability and costs were considered in transitioning from active remediation to passive technologies at both sites. At the Dynamic Underground Stripping (DUS) project at the M-Area Settling Basin, ASVE was combined with steam injection to extract cVOCs during active operations. Steam injection occurred from September 2005 to September 2009. DUS utilized 63 steam injection wells, 34 active vapor extraction wells, and 3 active soil vapor extraction units (SVEUs). Two active SVEUs had 60 horsepower blowers; the third had a 25-horsepower blower. Mass removal was closely tracked during DUS operations; over 181,437 kilograms (400,000 pounds) of cVOCs were removed while active steam injection occurred. After steaming was stopped, ASVE continued. The 34 active wells were evaluated in 2012. The ASVE wells were grouped into categories of high, medium, and low extraction rates. High producing wells remained connected to a single active SVEU. Low producing wells were abandoned, and the medium producing wells were transitioned to PSVE (Microblowers{sup TM}). Microblowers{sup TM} utilize a dedicated blower per well and are solar powered. This passive technology provides energy, maintenance, and operation costs savings while still providing an efficient reduction in cVOC migration to groundwater. In 2018, the remaining ASVE wells were evaluated again. The purpose of this testing was to identify which wells removed the most mass. An optimal well configuration was determined. The criteria to discontinue ASVE was removal of less than 18 kilograms (40 pounds) per week of cVOCs. After 3 months of shutdown (rebound conditions), 2.7 kilograms (5.9 pounds) of cVOCs per week were being removed. Data from the rebound test justified ending ASVE and transitioning wells with higher extraction rates to PSVE. Wells that had depleted the cVOC mass within their zone of influence were abandoned. Performance data from existing PSVE wells justified ending PSVE at wells with depleted extraction rates. Currently the system has 16 PSVE wells operating. Another ASVE system was being used to treat cVOC contaminated soil at the A-Area Miscellaneous Rubble Pile (AMRP) at SRS. System operation began in 2004, with 7 ASVE wells connected to a 60- horsepower blower. Mass removal rates and contaminant concentrations remained consistently low over the ASVE lifespan at AMRP. This indicated that mass removal was diffusion limited. With this data, the 7 ASVE wells were transitioned to PSVE in 2017. Twelve pressure monitoring points were also transitioned to PSVE wells. AMRP currently has 19 PSVE wells operating. Both transitions from active to passive remediation had concurrence from the United States Environmental Protection Agency and the South Carolina Department of Health and Environmental Control. These transitions ensure that only the necessary amount of energy is being exerted to remediate the environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Evaporation on Vapor Space Flammability in DWPF Process Vessels - 20278

The Savannah River Site (SRS) Defense Waste Processing Facility (DWPF) processes liquid high-level waste (HLW) and encapsulates it in glass within stainless-steel containers suitable for safe, long-term storage and disposal. Radiolytic and chemical decomposition of the liquid waste generates hydrogen and other flammable gases creating a hazard. The rate of flammable gas generation increases by an order of magnitude as temperature increases from sub-boiling to boiling. DWPF controls this hazard in process tanks by ensuring a minimum purge flow through each tank's head space. The minimum purge flow rate is established assuming dry air and neglecting evaporation. However, this study determined that steam from boiling in a representative process tank is sufficient to dilute flammable gases and, thereby, preclude flammability. For sub-boiling, water vapor is an insufficient diluent considering hydrogen's lower flammable limit (LFL) in air. However, the upper and lower flammable limits approach each other in a hydrogen-air-water-vapor environment as the water vapor concentration increases. This effect may preclude flammable conditions if water vapor concentration is about 60 volume percent or higher. A saturated, constant-pressure air-water system would achieve 60 volume percent water vapor at 86 deg. C. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Liquid-Vapor Coexistence and Critical Point of Mg 2 SiO 4 From Ab Initio Simulations

Hypervelocity impact-driven vaporization is characteristic of late-stage planet formation. Yet the behavior and properties of liquid-vapor mixtures of planetary materials of interest are typically unknown. Multiphase equations of state used in hydrodynamic simulations of planet impacts therefore lack reliable data for this important phenomenon. Here, we present the first constraints on the liquid-vapor critical point and coexistence phase boundary of Mg2SiO4 computed from ab initio molecular dynamics simulations. We found that the vapor is depleted in magnesium and enriched in silica and oxygen, while the coexisting liquid is enriched in magnesium and depleted in oxygen, from which we infer vaporization is incongruent. The critical point was estimated from an equation of state fit to the data. The results are in line with recent calculations of MgSiO3 and together confirm that extant multiphase equation of state (EOS) models used in planetary accretion modeling significantly underestimate the amount of supercritical material postimpact.

58 GEOSCIENCES↗

Vapor kinetic energy for the detection and understanding of atmospheric rivers

Poleward water vapor transport in the midlatitudes mainly occurs in meandering filaments of intense water vapor transport, spanning thousands of kilometers long and hundreds of kilometers wide and moving eastward. The water vapor filaments are known as atmospheric rivers (ARs). They can cause extreme wind gusts, intense precipitation, and flooding along densely populated coastal regions. Many recent studies about ARs focused on the statistical analyses of ARs, but a process-level understanding of ARs remains elusive. Here we show that ARs are streams of air with enhanced vapor kinetic energy (VKE) and derive a governing equation for Integrated VKE to understand what contributes to the evolution of ARs. We find that ARs grow mainly because of potential energy conversion to kinetic energy, decay largely owing to condensation and turbulence, and the eastward movement is primarily due to horizontal advection of VKE. Our VKE framework complements the integrated vapor transport framework, which is popular for identifying ARs but lacks a prognostic equation for understanding the physical processes.

54 ENVIRONMENTAL SCIENCES↗

Non-Contact Vapor Detection of Illicit Drugs via Atmospheric Flow Tube-Mass Spectrometry

Real-time, non-contact detection of illicit drugs is a desirable goal for the interdiction of these controlled substances, but the relatively low vapor pressures of such species present a challenge for trace vapor detection technologies. The introduction of atmospheric flow tube-mass spectrometry (AFT-MS), which has previously been demonstrated to detect gas-phase analytes at low parts-per-quadrillion levels for explosives and organophosphorus compounds, also enables the potential for non-contact drug detection. With AFT-MS, direct vapor detection of cocaine and methamphetamine from ~5 µg residues at room temperature is demonstrated herein. Furthermore, thermal desorption of low- to sub-picogram levels of cocaine, methamphetamine, fentanyl, and heroin is observed via AFT-MS using a carrier flow rate of several L/min of air. These low levels can permit non-contact sampling through collection of vapor, effectively preconcentrating the analyte before desorption and analysis. Quantitative evaluation of the thermal desorption approach has yielded limits of detection (LODs) on order of 10 fg for cocaine and fentanyl, 100 fg for methamphetamine, and 1.6 pg for heroin. The LOD for heroin was lowered to 200 fg by using tributyl phosphate as a dopant to form a proton-bound heterodimer with heroin. When used with AFT-MS, the intentional formation of specific drug-dopant adducts has the potential to enhance detection limits and selectivity of additional drug species. Species that are prone to form adducts present a challenge to analysis, but that difficulty can be overcome by the intentional addition of a dopant. Molecules unlikely to form adducts will remain essentially unimpacted, but the adduct-forming species will interact with the dopant to compress the analyte signal into a single peak. This approach would be valuable in the application of non-contact screening for illicit substances via vapor collection followed by thermal desorption for analysis.

methamphetamine, cocaine, heroin, fentanyl, atmosp↗

Optimization of lithium vapor box divertor evaporator location on NSTX-U using SOLPS-ITER

Commercial fusion reactors will be faced with extremely high divertor target heat fluxes that will require mitigation. Simulations of detachment in an NSTX-U scenario projected to have 92 MW/m 2 unmitigated peak target heat flux are presented, which reaches sub-10 MW/m 2 target heat flux using a highly dissipating lithium vapor box divertor design. The lithium vapor box is a detached divertor design which employs lithium vapor evaporation and condensation to contain lithium below the X-point. Previous SOLPS modeling has indicated a lithium vapor box can reduce the heat flux down to 10 MW/m 2 via simultaneous evaporation from the Private Flux Region (PFR) and the Common Flux Region (CFR) sides of the vapor box. It is found here that PFR evaporation has improved access to the separatrix leading to significantly more efficient power dissipation than CFR evaporation. Simulations of target evaporation with an evaporation distribution that is self-consistent with the temperature of a Capillary Porous System with Fast flowing liquid lithium (CPSF) could reach n Li / n e ~ 0.025-0.030 at the Last Closed Flux Surface (LCFS) depending on the liquid metal flow speeds and lithium sputtering yield, while PFR-side evaporation can reach acceptable heat fluxes with n Li / n e ~ 0.038 at the LCFS. However, PFR evaporator performance can be improved if the target is allowed to be hot enough such that it reflects lithium, reaching n Li / n e ~ 0.028 and reducing required lithium evaporation. Ultimately PFR evaporation and target evaporation are found to have similar ability to produce acceptable heat flux solutions with minimal upstream concentration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗