Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “utility incentives”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

HPC Digital Twins for Evaluating Scheduling Policies, Incentive Structures and their Impact on Power and Cooling

Schedulers are critical for optimal resource utilization in high-performance computing. Traditional methods to evaluate sched- ulers are limited to post-deployment analysis, or simulators, which do not model associated infrastructure. In this work, we present the first-of-its-kind integration of scheduling and digital twins in HPC. This enables what-if studies to understand the impact of parameter configurations and scheduling decisions on the physical assets, even before deployment, or regarching changes not easily realizable in production. We (1) provide the first digital twin framework extended with scheduling capabilities, (2) integrate various top-tier HPC systems given their publicly available datasets, (3) implement extensions to integrate external scheduling simulators. Finally, we show how to (4) implement and evaluate incentive structures, as- well-as (5) evaluate machine learning based scheduling, in such novel digital-twin based meta-framework to prototype scheduling. Our work enables what-if scenarios of HPC systems to evaluate sustainability, and the impact on the simulated system.

Maiterth, Matthias [ORNL] (ORCID:000000018698460X)↗

Cost targets to achieve commercially viable thermal storage in buildings

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. In this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. Lastly, the economic value implied by different types of deferred peak power plants were reviewed. The full value of TES to the entire society consists of value to the utility, OEMs, facility installers, and other stakeholders. This report focuses on the value to the utility with emphasis on the deferred capital of peak power plant. The value from the deferred capital of peak power plant is manifested to the customer in the form of demand reduction program and Time-of-Use utility rate program. In this report, an initial proxy of the value of TES is made by assuming the deferred capital cost of power plant is the full value to reduce peak demand. Three levels of financial value of TES systems were assessed. Two are currently available to some residential customers: (1) the benefit from TOU pricing alone and (2) the benefit from TOU pricing in combination with DR incentive programs. The third level was computed as the full cost of deferred capital cost of peaking power plants. This represents the potential value that could be gained by the utilities or conceivably be offered to consumers.

25 ENERGY STORAGE↗

Electric Vehicle Adoption in Illinois

Over 1.3 million plug-in electric vehicles (PEVs) have been sold in the United States since 2010 when the first Chevy Volt and Nissan Leaf vehicles came on the market. Currently, electric vehicles account for about 2% of monthly light-duty vehicle (LDV) sales. More than 40 different electric vehicle models are actively being marketed, and most of these are LDVs. Over the last few years, automakers have brought more models, with varying mileage ranges, to the market, including medium-duty and heavy-duty trucks and buses. Government agencies at the federal, regional, and state levels, as well as utilities across the United States, have provided financial and non-financial incentives to promote electric vehicle adoption and charging infrastructure deployment. Argonne National Laboratory, sponsored by the U.S. Department of Energy, has developed tools and collected data to quantify the energy, economic, and environmental benefits of electric vehicles. This project has three objectives. First, we summarize the policies and other actions of the federal government, various states/regions, and utilities to promote PEV adoption, and evaluate their relative effectiveness based on a review of the literature. Second, we identify possible PEV adoption paths or scenarios that would result in PEVs making up 15% of all on-road vehicles in Illinois, and we quantify the resulting impacts on petroleum consumption and electricity demand. We also summarize the possible reduction in greenhouse gas (GHG) and criteria pollutant emissions due to PEV adoption. The PEV scenarios include private and public adoption of electric cars, light trucks (e.g., sports utility vehicles [SUVs], vans, pickups), medium-duty vehicles (MDVs), and heavy-duty vehicles (HDVs). Third, we estimate hourly charging loads of light-duty PEVs in 2030 associated with these scenarios, incorporating assumptions about vehicle electric range, efficiency, and travel behavior.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

First Wave of Incentive-Driven CCS Projects in North Dakota

Conference poster presented at American Association of Petroleum Geologists (AAPG) Carbon Capture, Utilization, and Storage (CCUS) Conference, Houston, Texas, March 28–30, 2022. While the central interior of North America offers a tremendous storage resource, optimization will be key to meaningfully reducing the more than 2.6 billion tons of CO 2 emitted annually from large point sources in the United States. These initial projects tend to have the most favorable economics and are often able to take advantage of the best geology, with little to no competition for resource. This initial wave of projects is informing investment in and creating the opportunity for innovation that will enable the next wave of incentive-based CCS projects. Such innovation is critical for reducing costs, enhancing the design and operability of the next wave of CCS projects, and realizing more of the 250 billion tons of storage resource in North Dakota.

01 COAL, LIGNITE, AND PEAT↗

A New Gold Mine? Achieving HVAC Energy Efficiency Through a System Metric

Washington State's Commercial Energy Code adopted a new energy metric called HVAC Total System Performance Ratio (TSPR) in 2019, a first in the codes world to regulate HVAC system efficiency. TSPR is a ratio of annual heating and cooling loads to the annual carbon emissions associated with the energy consumed by the HVAC system. TSPR provides a performance-based solution to evaluate and improve the overall HVAC design. The TSPR metric and its companion calculation tool were developed by Pacific Northwest National Laboratory (PNNL) with support from U.S. Department of Energy (DOE), Northwest Energy Efficiency Alliance (NEEA) and the City of Seattle. The new metric represents a significant shift in how HVAC design will meet code requirements. Utility programs can also leverage TSPR as a measure to determine energy savings and incentive amounts for HVAC retrofits. This paper describes the efforts by NEEA and its collaborators to prepare the market for TSPR adoption in code. This paper provides the pilot projects led by University of Washington Integrated Design Lab (IDL) to understand potential issues that could be faced by early adopters. This paper also covers how training and outreach provide engagement opportunities that can streamline code compliance, help address issues faced by early adopters and promote participation in utility programs. As Washington State works on the goals of 70% energy reduction and zero fossil-fuel greenhouse gas emission homes and buildings by the year 2031 , system level performance metrics will likely become increasingly more necessary and prevalent. This paper concludes that the HVAC TSPR requirement helps familiarize the HVAC industry with this approach and helps Washington achieve its long-term goals.

Liu, Bing↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The U.S. Accident Tolerant Fuels Program — Update on a National Initiative

In 2012 the U.S. Congress directed the Department of Energy’s (DOE) Office of Nuclear Energy to give priority to developing enhanced fuels and cladding for light water reactors to improve safety in the event of accidents in the reactor or spent fuel pools. DOE developed a plan with a goal to insert a Lead Test Assembly (LTA) into a commercial light water reactor by the end of FY 2022. Three of the leading commercial nuclear fuel vendors, in concert with several participating commercial nuclear utilities, are now seriously engaged in this initiative and have exceeded initial expectations by having met DOE’s goal this year, three years ahead of schedule. The early successes of the ATF program are due in part to a strong collaboration by the DOE national laboratories with both commercial nuclear fuel vendors and the U.S. Nuclear Regulatory Commission. This undertaking has recently been expanded to incorporate an effort to extend burnup from the current U.S. regulatory limit of 62 GWD/MTU and increase enrichment as necessary to support routine utilization of fuel at >75 GWD/MTU. This effort provides a critical economic incentive to accelerate the deployment of ATF technologies. This paper reviews the DOE-sponsored, industry-led ATF concepts currently under development and highlights the contributions made by the DOE laboratories in support of these ATF concepts, including: 1) steady-state irradiation testing in the Advanced Test Reactor (ATR) and High Flux Isotope Reactor (HFIR); 2) transient irradiation testing in the Transient Reactor Test Facility (TREAT); 3) fabrication process development and characterization of high density fuels, Cr-coated Zry cladding, FeCrAl cladding, and SiC cladding; and 4) post-irradiation examination of lead test rods irradiated in commercial reactors.

Goldner, Frank J.↗

Current status of anaerobic digestion of food waste in the United States

Utilization of food waste (FW) and food processing waste streams in waste-to-energy technologies has increased over the years in United States (US). This review paper compiled information from published literature and open data sources to obtain a holistic view of the current state of FW availability and its management using anaerobic digestion (AD). The review examined the usage of FW as a feedstock for AD by considering the feedstock composition and availability of FW in the US as well as challenges and opportunities with implementing FW in mono- and co-digestion. Also presented are global trends in FW digestion and the current status of FW codigestion in the US. FW in the US was characterized with regard to volume and composition to show a need for waste management and an opportunity for valuable resource recovery. Challenges and opportunities of processing via AcoD were presented to review best practices for successful operations. Environmental standards, economic incentives, and governmental policies in the US and around the world regarding waste management and utilization were discussed to identify barriers and sources of opportunity for large-scale implementation of AcoD. Additionally, a range of facilities throughout the US was examined for information regarding digestion type, feedstock (s), biogas production and utilization, and energy self-sufficiency to better understand the current status of FW digestion. Several US facilities were outlined as case studies that co-digest FW and produce and utilize biogas for various applications. Future strategies, perspectives, and roadmaps were discussed to elucidate the shaping of future FW management practices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Economic and operational investigation of CO 2 sequestration through enhanced oil recovery in unconventional reservoirs in Colorado, USA

The ongoing CCUS commercial projects are highly relied on the support of government incentives due to massive capital investment. Here, this study analyzes the economics of carbon capture utilization and sequestration (CCUS) projects, shows a state-wide CCUS deployment exercise, followed by simulation results of enhanced oil recovery (EOR) based CO 2 storage in unconventional reservoirs. The comprehensive economic analysis of capture, transportation, sequestration costs, enhanced 45Q tax credits, and EOR revenue implies the practicality of CO 2 -EOR to offset the high CCUS costs. With the economics understanding, we study the top CO 2 sources, existing CO 2 pipelines, and sequestration sinks in the state of Colorado, USA. This paper next presents results from EOR simulation in one section of the unconventional Denver-Julesburg (DJ) Basin Niobrara and Codell reservoirs. The simulation model is based on a geological static model, incorporated with hydraulic fracture stimulation, history matched to production, and calibrated to the microseismic and time-lapse surface seismic data. The CO 2 -EOR simulation results show that oil production can be increased and more CO 2 stored with: a longer primary production period; the presence of a shut-in period; higher injection rates; and multi-well injectors. The modeling results show that about 7–10 Mscf of CO 2 will be stored when recovering 1 stb of EOR oil. By adding the enhanced oil revenue and the carbon credits together, it is estimated that the most economic case can generate $\$13$ MM when oil price is assumed to be $\$80$/stb, and the EOR oil revenue is 3.4 times greater than that generated from 45Q incentives. It corresponds to the scenario that a five-year primary production is followed by CO 2 injection into four wells with the sequence of injection (4 MMscf/day for 6 months), shut-in (6 months) and production (12 months). The best practices in this study will provide valuable insights for similar CCUS projects in other unconventional fields. Furthermore, this study defines a term named “Carbon Neutrality Index (CNI)” by comparing the amount of CO 2 stored with that burned by EOR oil. The CNI value of 0 indicates the enhanced oil is carbon neutral; a negative CNI value implies there is a net reduction in carbon emission. The 4-year huff-n-puff (HnP) simulation leads to a positive CNI value, indicating that the EOR oil generated in this process is not carbon neutral yet.

03 NATURAL GAS↗

The impact of market design and clean energy incentives on strategic generation investments and resource adequacy in low-carbon electricity markets

Well-designed electricity markets play a crucial role in maintaining reliable electric power systems, which are critical in modern society. Here, this study examines the impact of different electricity market designs and clean energy incentive schemes on supporting renewable energy integration and achieving clean energy goals. To this end, we utilize a game-theoretical generation expansion planning model where generation companies make investment and retirement decisions to maximize their expected profit. The model is structured as an equilibrium problem with equilibrium constraints (EPEC) and solved using a diagonalization approach combined with progressive hedging. We analyze three types of electricity market designs: an energy-only market, a capacity market, and a clean energy market, and consider a wide range of market parameters resulting in 14 total scenarios. Wind and solar capacity comprise the majority of new investments in all considered scenarios, but the resultant system planning reserve margin (PRM) can differ significantly depending on market parameters. We also find that profit-driven investments lead to lower PRMs than a traditional system cost minimization approach. These individual scenario results further demonstrate how different market designs and clean energy incentive schemes may influence investor decision-making and impact resource adequacy throughout the clean energy transition.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Active and passive cooling approaches for a Southern California residential community

This study assesses cooling strategies in a low-income community in Southern California that lacks air conditioning and struggles with heat and air pollution. We used an urban building energy model and an electric distribution system model to evaluate active and passive cooling measures. The most effective space cooling measures were high-performance air-source heat pumps, cool coatings, window films, and harnessing the space cooling effect from heat pump water heaters. The results show that combining heat pump water heaters with window films and cool coatings reduces heat index hazard hours within buildings by 95 % to 99 % but increases total energy costs (equipment costs plus changes in utility bills) by 20 % to 60 % where the higher end includes building electrical upgrades. These measures also led to increased space heater use during colder months to avoid overcooling. Replacing conventional heaters with air source heat pumps eliminated unsafe indoor temperatures and reduced total energy use, but increased cost by 125 % to 150 %. In total, using heat pumps for space and water heating could reduce primary energy use by up to 57 %. The higher cost of active and passive cooling measures can be mitigated by existing and emerging incentive programs, especially those that support heat pumps. Electric distribution upgrades to support community electrification are estimated to increase utility costs by $\$$25 to $\$$40 per ratepayer per year. The results underscore the potential and challenges of adapting building infrastructure in communities at risk from climate and environmental stressors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Factors influencing recent trends in retail electricity prices in the United States

This study analyzes the primary drivers of recent state-level trends in U.S. retail electricity prices. We summarize pricing trends, explore descriptive relationships, and employ regression models to quantify the influence of various factors. Although the recent national rise in retail prices has largely tracked inflation, state-level trends vary widely. We identify a number of factors that explain trends in subsets of states. States with the greatest price increases typically exhibited shrinking customer loads—partially linked to growth in net metered behind-the-meter solar—and had renewables portfolio standards (RPS) in concert with relatively costly incremental renewable energy supplies. By contrast, recent utility-scale wind and solar deployment that occurred outside RPS programs (but that benefited from tax incentives) had no discernible impact on increased retail prices. Hurricanes, storms and wildfires also contributed to sizable price increases in some states, most notably in California, where wildfire risk mitigation and liability insurance were major cost drivers. Fluctuations in natural gas prices—particularly following the onset of the Ukraine-Russia war—further contributed to sharp price increases through 2022–2023 in many states, with moderation in 2024. The relative influence of these factors varies across states and over time, and relationships may change in the future. Nonetheless, the findings underscore the diverse set of price determinants and highlight the need for continued research to inform effective policy and ensure customer affordability.

Customer load↗

Influence of Business Models on PV-Battery Dispatch Decisions and Market Value

PV-battery hybrid projects dominate interconnection queues in some regions in the United States, but few projects have been operational long enough to assess how the hybrid capabilities may be used in practice. We interview plant operators and analyze empirical dispatch data for eleven large-scale PV-battery hybrids in three organized wholesale markets in the United States. We use the dispatch data and wholesale market prices to estimate the market value of our sample hybrids in 2020. The empirical increase in market value of a PV-battery hybrid relative to a standalone PV plant varies by project and ranges from $\$$1 to $\$$48/MWhsolar. The premium is driven by market, location, technical characteristics of the PV and battery asset, and battery dispatch strategies. In contrast to the widespread assumptions in the PV-battery hybrid modeling literature, only three of the eleven project operators optimize battery usage for wholesale market revenue as merchant plants. Instead, the majority of operators in the sample have alternate objectives. For example, load-serving entities target peak load reductions, incentive program participants focus on compliance with program requirements, and large energy consumers prioritize resiliency and utility bill minimization. Understanding prevalent dispatch signals and the degree of alignment with system-wide grid needs can increase the market value of PV-battery hybrids.

14 SOLAR ENERGY↗

Advancing Understanding of Geothermal Representation in the Power Sector to Accelerate Deployment

Driven mostly by decarbonization goals, geothermal interest in the US power sector has grown considerably, gradually evolving from being considered a niche technology, to being recognized as a viable source of clean, baseload, grid-balancing power, and renewable electric power generation. Furthermore, recent technical advances that could greatly accelerate deployment in the near future, and US federal incentives for low-carbon generation technologies, including geothermal, can enable opportunities for integrating geothermal into utilities resource planning portfolios. However, in general, utilities do not have in-house expertise to evaluate geothermal technologies and its potential role in helping decarbonize the grid as well as help them achieve their individual decarbonization goals. To date, geothermal is rarely included in Capacity Expansion Models (CEM) which utilities use in their planning activities and resource/technologies prioritization. To this end, EPRI and NREL are working together in a DOE-GTO funded research project to improve geothermal understanding (opportunities, value, risks) among the power industry to help accelerate geothermal deployment. In the present paper we describe the approach and preliminary findings of this work, focused on two topics: 1) Expand the degree of understanding on the value, opportunity, and risk of geothermal technologies among utilities and related companies/groups, specifically around geothermal for power generation. 2) Improve representation of geothermal power technologies in capacity expansion models (CEM).

capacity expansion models↗

Performance Assessment of Low-GWP Refrigerated Reach-In Display Cases

This project is part of an effort by Commonwealth Edison Company (ComEd) to evaluate the energy and peak demand savings potential of emerging technologies in the Chicago area. This document focuses on the assessment of energy-efficient, medium-temperature, self-contained refrigerated display cases utilizing environmentally friendly refrigerants. The results of this evaluation will be considered by ComEd and CLEAResult to develop a new energy efficiency rebate measure for ComEd's incentive programs. This rebate measure will become an addition to the Technical Reference Manual. In 2016, the United Nations passed the Kigali Montreal Protocol Amendment, which placed restrictions on certain types of refrigerants. In compliance with this amendment, the U.S. Environmental Protection Agency (EPA) placed a ban on the manufacture of refrigeration systems using hydrofluorocarbons including R134a starting in January 2020. Although the ban has halted manufacture, the EPA continues to allow the use of these refrigerants. Therefore, it is critical to provide incentives for replacing these refrigerants with other environmentally friendly and energy-efficient alternatives.

alternative refrigerants↗

Evaluating the Impact of Residential Solar Contract Cancellations in the United States

The residential solar photovoltaic (PV) market in the United States is growing, despite frequent customer cancellations. Contract cancellations result in lost time and costs that must be borne by installers, often in the form of higher "soft costs" (i.e., non-equipment costs). These costs are often passed on to customers who successfully install PV systems. To date, few studies have attempted to estimate national cancellation rates or model the impacts on installed system costs. In this report, we utilize an installer-provided dataset of 199,665 residential PV-only projects representing about 10% of U.S. installs each year from 2017-2019. With this data, we evaluate cancellation rates and trends from contract signing to install. Next, by leveraging NREL's soft cost model for residential solar, we estimate installer spending through each phase of the pre-install process. Applying our findings on cancellation timelines and rates, we then estimate the potential cost impacts to successful installs from contract cancellations. Our work suggests that the rates and impacts of contract cancellations have been previously underestimated. Namely, we find that cancellations/unsuccessful project are; more common than previous estimates suggest; occur earlier in project timelines, though a significant number happen even after permit/ATB approvals; and contribute significantly to customer acquisition and other soft costs. We also find that cancellation do not appear to be driven by review delays in permitting and interconnection applications.

14 SOLAR ENERGY↗

Facets of hydro power and future trends in a Nordic Context

Hydropower technologies bolster high penetration of variable renewable energies (VREs) in the net zero emissions scenarios. Nevertheless, there are various challenges to meeting the ambitious goal, such as stability, reliability, resiliency, security, lack of reactive power, voltage support and inertia, large-scale storage deployment and coordination, interconnectedness, demand-side response, higher thermal cycles with increased start/stops, and inadequate Levelized Cost of Energy (LCOE) for system-wise VRE integration and profitability. This survey conducts a bottom-up analysis to unveil the opportunities to utilize hydropower facilities and disentangle the nested problem for intertwining design features, control algorithms, operation, optimization approaches, incentives, services, and market mechanisms using a three-pillar framework perspective: grid owners, power producers, and machine designers. The survey identified emerging trends in real-time and capacity markets, flexible power systems, and enhanced grid capabilities, including advanced voltage support and updated grid codes. These developments present significant opportunities for hydropower, such as achieving super-flexibility through hybridization, expanded reactive power capabilities, and advanced operational modes like a synchronous condenser and power adequator functionalities. These opportunities require novel design philosophies — including new winding, stator, and rotor configurations, optimized ventilation, and active cooling systems — to enhance performance under stressed grid and climate conditions. Finally, integrating climate and energy models for multi-basin optimization with finer spatial and temporal granularity enhances the planning accuracy for water management of hydropower while addressing environmental challenges. The review delivers helpful prospective suggestions and tools that would serve researchers, power engineers, and stakeholders in making decisions about hydropower technologies and services in 2050 and beyond.

13 HYDRO ENERGY↗

Efficiency and Demand Flexibility in Large Office Buildings: The Potential for Cost Savings and CO 2 Reductions from Lighting and Cooling Measures

This report presents the estimated impact of lighting and cooling efficiency and demand flexibility measures in large office buildings in each state in the contiguous United States. It provides modeled results for three different metrics: bill savings, regional grid operational costs savings, and carbon dioxide (CO 2 ) emissions reductions. Lighting efficiency and demand flexibility are estimated to reduce load by up to 80 MWh/yr in a single large office building. These load reductions result in customer bill savings of up to $8,800/yr per building, with the highest savings in southern and midwestern states. Grid operating cost savings are estimated at up to $3,240/yr/building, with greatest benefit in southern and northeastern states. CO 2 emissions reduction potential is highest in the Dakotas, Nebraska, across the Midwest, in West Virginia, and in Mississippi (<48,200 kg/yr/building). Comparatively, cooling measures are found to have less load reduction potential (<28.5 MWh/yr/building), with the greatest potential in southern states including Texas, which ranks top of the list across several of the metrics studied. In numerous states, shifting cooling load to off-peak hours is found to increase costs and CO 2 emissions because precooling results in increased load during high-cost or high-CO 2 emissions periods. In general, focusing on cooling efficiency and load shedding has the potential for more savings. In all cases, the specific rate structure is a significant determinant in actual bill savings, which are up to $4,000/yr/building. To realize the full potential for bill savings through an energy measure, building operators must identify how the measure will change the building load pattern and the interaction of this load change with the applicable rate tariff. To realize CO 2 emissions reductions, industry and state coordination is needed to verify which fuel source is on the margin and then to create incentives for end users to reduce load during high-CO 2 emissions hours. Regular updates to data sets and analyses are critical. Regulators and policymakers are well positioned to facilitate the necessary coordination between the electric industry and building energy managers to develop appropriate price signals and incentives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗