Commissioning of the Delta Polarizing Undulator at LCLS

The Linac Coherent Light Source (LCLS) generates linearly polarized, intense, high-brightness x-ray pulses from planar fixed-gap undulators. While the fixed-gap design supports a very successful and tightly controlled alignment concept, it provides only limited taper capability (up to 1% through canted pole and horizontal position adjustability) and lacks polarization control. The latter is of great importance for soft x-ray experiments. A new 3.2-m-long compact undulator (based on the Cornell University Delta design) has been developed and installed in place of the last LCLS undulator segment (U33) in October 2014. This undulator provides full control of the polarization degree and K value. Used on its own, it produces fully polarized radiation in the selected state (linear, circular or elliptical) but at low intensity. To increase the output power by orders of magnitude, the electron beam is micro-bunched by several (~10) of the upstream LCLS undulator segments operated in the linear FEL regime. As unavoidable by-product, this microbunching process produces moderate amounts of horizontally linear polarized radiation which mixes with the radiation produced by the Delta undulator. This unwanted radiation component has been greatly reduced by the reverse taper configuration, as suggested by E. Schneidmiller and M. Yurkov. Full elimination of the linear polarized component was achieved through spatial separation combined with transverse collimation. The paper describes these and other methods tested during commissioning. It also presents results of polarization measurements showing high degrees of circular polarization in the soft x-ray wavelength range (500 eV - 1500 eV).

43 PARTICLE ACCELERATORS↗

High performance superconducting undulator

A high performance superconducting undulator magnet is provided. The superconducting undulator magnet includes inset grooves in which magnetic poles are attached. The superconducting undulator magnet also includes clips for use in winding. The superconducting wire is wound such that the each revolution of the wire has a precise position within each of the grooves, the precise position being repeated in each groove. The superconducting undulator magnet provided will have a mechanical precision to preserve uniformity of the magnetic pole width and coil grooves. The undulator system provides uniformity of the undulator gap.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray free-electron lasing in a flying-focus undulator

Laser-driven free-electron lasers (LDFELs) replace magnetostatic undulators with the electromagnetic fields of a laser pulse. Because the undulator period is half the wavelength of the laser pulse, LDFELs can amplify X rays using lower electron energies and over shorter interaction lengths than a traditional free-electron laser. In LDFELs driven by conventional laser pulses, the undulator uniformity required for high gain necessitates large laser-pulse energies. Here, we show that a flying-focus pulse provides the undulator uniformity required to reach high gain with a substantially lower energy than a conventional pulse. The flying-focus pulse features an intensity peak that travels in the opposite direction of its phase fronts. This enables an LDFEL configuration where an electron beam collides head-on with the phase fronts and experiences a near-constant undulator strength as it co-propagates with the intensity peak. Three-dimensional simulations of this configuration demonstrate the generation of megawatts of coherent X-ray radiation with 20 × less energy than a conventional laser pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Undulator beamline of the Brockhouse sector at the Canadian Light Source

The Brockhouse project at the Canadian Light Source plans the construction of three beamlines, two wiggler beamlines, and one undulator beamline, that will be dedicated to x-ray diffraction and scattering. In this work, we will describe the undulator beamline main components and performance parameters, obtained from ray tracing using XOP-SHADOW codes. The undulator beamline will operate from 4.95 to 21 keV, using a 20 mm period hybrid undulator placed upstream of the wiggler in the same straight section. The beamline optics design was developed in cooperation with the Brazilian Synchrotron - LNLS. The beamline will have a double crystal monochromator with the options of Si(111) or Si(311) crystal pairs followed by two mirrors in the KB configuration to focus the beam at the sample position. The high brilliance of the undulator source will produce a very high flux of ∼10{sup 13} photons/s and high energy resolution into a small focus of 170 μm horizontal and 20-60 μm vertical, depending on the optical configuration and energy chosen. Two multi-axis goniometer experimental stations with area detectors and analyzers are foreseen to enable diffraction, resonant and inelastic scattering experiments, and SAXS/WAXS experiments with high resolution and time resolving capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of the soft x-ray undulator beamline at the Siam Photon Laboratory

The synchrotron radiation from the first undulator at the Siam Photon Laboratory was characterized with the photon beam position monitors (BPMs) and grating monochromator. The soft x-ray undulator beamline employs a varied line-spacing plane grating monochromator with three interchangeable gratings. Since 2010, the beamline has delivered photons with energy of 40-160 and 220-1040 eV at the resolving power of 10,000 for user services at the two end- stations that utilize the photoemission electron spectroscopy and microscopy techniques. The undulator power-density distributions measured by the 0.05-mm wire-scan BPM were in good agreement with those in simulation. The flux-density distributions were evaluated in the red-shift measurements, which identify the central cone of radiation and its distribution. Since 2014, the operation of the other insertion devices in the storage ring has started, and consequently bought about the increases in the emittance from 41 to 61 nm·rad and the coupling constant from 4 to 11%. The local electron-orbit correction greatly improved the alignment of the electron beam in the undulator section resulting in the improvements of the photon flux and harmonics peaks of the undulator radiation.

43 PARTICLE ACCELERATORS↗

Status of the Development of Superconducting Undulators for Storage Rings and Free Electron Lasers at the Advanced Photon Source

Development of superconducting undulator (SCU) technology continues at the Advanced Photon Source (APS). The experience of building and successful operating the first short-length, 16-mm period length superconducting undulator SCU0 paved the way for a 1-m long, 18-mm period device— SCU18-1— which has been in operation since May 2015. The APS SCU team has also built and tested a 1.5-m long, 21-mm period length undulator as a part of the LCLS SCU R&D program, aimed at demonstration of SCU technology availability for free electron lasers. This undulator successfully achieved all the requirements including a phase error of 5° RMS. Our team has recently completed one more 1-m long, 18-mm period length undulator— SCU18-2— that is replacing the SCU0. We are also working on a helical SCU for the APS. The status of these projects will be presented.

Ivanyushenkov, Y.↗

A Study of undulator magnets characterization using the Vibrating Wire technique

The vibrating wire (VW) technique employs a stretched wire as a magnetic field sensor. Because of the wire's small diameter ({approx}0.1mm or smaller) and because the wire can be supported from outside the magnet, this technique is very appealing for field measurements in small gap/bore undulators with small good field regions and with limited access to the tested field. In addition, in the case of elliptical undulators in which Hall probe (HP) measurements can be affected by the planar Hall effect, VW technique can be used as an independent method to verify and supplement HP measurements. In this article we studied the potential of the VW technique for measurement of magnetic field errors and for prediction of beam trajectories in undulator magnets using a 3.8m long LCLS undulator as a test bench. Introducing calibrated magnetic field distortion at various locations, we measured the sensitivity and spatial resolution of the method. The method demonstrated 0.9mm spatial resolution at a distance up to a few meters and 0.37Gcm sensitivity to the field integral. To compare Hall probe and Vibrating wire measurements side-by-side, we measured field errors in an LCLS undulator previously characterized by Hall probe measurements. The field errors found with the Vibrating Wire technique appeared to be in good agreement with errors measured with the Hall probe. Beam trajectory distortions calculated from both data sets are also in a good agreement.

43 PARTICLE ACCELERATORS↗

Effects of a long low-gap in-vacuum undulator on the impedance and beam lifetime

Possible installation of a long low-gap in-vacuum undulator in the NSLS-II storage ring could result in several impedance-related and beam lifetime issues. High impedance of the low-gap undulator can result in beam instabilities and beam-induced overheating of the undulator itself. These issues have been preliminary studied using analytical formulae, computer simulations and experience of operations with existing in-vacuum undulators. Depending on the device location, the minimum gap and the overall ring-average residual gas pressure, an in-vacuum undulator (IVU) may appreciably shorten the elastic gas scattering component of the beam lifetime. When the latter becomes comparable to the Touschek lifetime, a significant reduction of the total beam lifetime will occur. Here this effect is studied by applying some well-known analytical formulas, as well as insights from NSLS-II operating experience. Finally, the issue of IVU radiation damage also needs to be looked at, and potentially addressed with a dedicated collimation system.

36 MATERIALS SCIENCE↗

Thermal Tests of Undulator Quad

Running at the nominal temperature, the undulator quadrupole has a several degree temperature increase. This note describes the test used to determine the effect on the undulator integrals from the temperature gradient caused by the heat from the quadrupole conducting down the beam pipe. The undulator quadrupoles running at their nominal current of 4 amps heat up approximately 4 degrees Celsius; this magnet in turn heats up the beampipe which goes into the undulator. The heating ends up introducing a thermal gradient across the undulator which causes small changes in the magnetic field of the heated poles. By measuring the temperature change in the poles we can model the effects on the field and determine what the magnetic errors will be.

43 PARTICLE ACCELERATORS↗

Magnetic Measurement of the Background Field in the Undulator Hall

The steel present in the construction of the undulator hall facility has the potential for changing the ambient fields present in the undulator hall. This note describes a measurement done to make a comparison between the fields in the hall and in the Magnetic Measurement Facility. In order for the undulators to have the proper tuning, the background magnetic field in the Undulator Hall should agree with the background field in the Magnetic Measurements Facility within .5 gauss. In order to verify that this was the case measurements were taken along the length of the undulator hall, and the point measurements were compared to the mean field which was measured on the MMF test bench.

36 MATERIALS SCIENCE↗

Magnetic Measurements of the Background Field in the Undulator Hall with Ductwork and Cable Trays

The duct work and cable trays present in the undulator hall facility are made out of potentially magnetically active materials. This note describes a measurement done to make a comparison between the fields in the undulator hall with the duct work and cable trays present and in the Magnetic Measurement Facility. In order for the undulators to have the proper tuning, the background magnetic field in the Undulator Hall must agree with the background field in the Magnetic Measurements Facility within 0.5 gauss. To verify that this was the case, measurements were taken along the length of the undulator hall, and the point measurements were compared to the mean field which was measured on the MMF test bench. This set of measurements was conducted with most of the cable trays and duct work in place, but without any of the magnet stands in place.

43 PARTICLE ACCELERATORS↗

Undulator Hall Air Temperature Fault Scenarios

Recent experience indicates that the LCLS undulator segments must not, at any time following tuning, be allowed to change temperature by more than about {+-}2.5 C or the magnetic center will irreversibly shift outside of acceptable tolerances. This vulnerability raises a concern that under fault conditions the ambient temperature in the Undulator Hall might go outside of the safe range and potentially could require removal and retuning of all the segments. In this note we estimate changes that can be expected in the Undulator Hall air temperature for three fault scenarios: (1) System-wide power failure; (2) Heating Ventilation and Air Conditioning (HVAC) system shutdown; and (3) HVAC system temperature regulation fault. We find that for either a system-wide power failure or an HVAC system shutdown (with the technical equipment left on), the short-term temperature changes of the air would be modest due to the ability of the walls and floor to act as a heat ballast. No action would be needed to protect the undulator system in the event of a system-wide power failure. Some action to adjust the heat balance, in the case of the HVAC power failure with the equipment left on, might be desirable but is not required. On the other hand, a temperature regulation failure of the HVAC system can quickly cause large excursions in air temperature and prompt action would be required to avoid damage to the undulator system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of Comb Fabricated Halbach Undulators

An approach to fabricating Halbach array undulators using “combs” machined from single magnets is introduced. This technique is especially relevant to the fabrication of short period micro-undulators with period lengths considerably less than the few-centimeter-scale typical of current undulators. Manual, magnet-by-magnet assembly of micro-undulators would require the manipulation and alignment of thousands of magnets smaller than a grain of rice: comb fabrication dramatically increases the size of the basic unit cell of assembly with no increase in undulator period by creating many periods from a single piece, in a single machining modality. Further, as these comb teeth are intrinsically indexed to each other, tolerances are dictated by a single manufacturing step rather than accumulating errors by assembling many tiny magnets relative to each other. Different Halbach geometries, including M ′ = 2 , M ′ = 4 , isosceles triangle, and hybrid, are examined both from a theoretical perspective and with 3D magnetostatic simulations.

Majernik, Nathan↗

Undulation and anomaly estimation using Geos-3 altimeter data without precise satellite orbits

Geos-3 altimeter data was used to obtain an approximate geoid undulation which was contaminated by long wavelength errors caused primarily by altimeter bias and orbit error. This error was reduced by fitting, with a low degree polynomial, the raw undulation data to the undulations implied by the GEM 7 potential coefficients in an adjustment process that included conditions on tracks that cross. These adjusted undulations were used to construct a geoid map in the Geos-3 calibration area using a least squares filter to remove the remaining noise in the undulations.

Rummel, R.↗

The indirect effects on the computation of geoid undulations

The indirect effects on the geoid computation due to the second method of Helmert's condensation were studied. when Helmert's anomalies are used in Stokes's equation, there are three types of corrections to the free air geoid. The first correction, the indirect effect on geoid undulation due to the potential change in Helmert's reduction, had a maximum value of 0.51 meters in the test area covering the United States. The second correction, the attraction change effect on geoid undulation, had a maximum value of 9.50 meters when the 10 deg cap was used in Stokes' equation. The last correction, the secondary indirect effect on geoid undulatin, was found negligible in the test area. The corrections were applied to uncorrected free air geoid undulations at 65 Doppler stations in the test area and compared with the Doppler undulations. Based on the assumption that the Doppler coordinate system has a z shift of 4 meters with respect to the geocenter, these comparisons showed that the corrections presented in this study yielded improved values of gravimetric undulations.

Wichiencharoen, C.↗

Spontaneous radiation from relativistic electrons in a tapered undulator

The spectrum, angular distribution, polarization, and coherence properties of the radiation emitted by relativistic electrons undulating through a quasiperiodic tapered magnetic field are studied. Tapering the wavelength and/or field strength along the undulator's axis has the effect of spreading the spectral line to higher frequencies; interference over this broader spectral range results in a more complex line shape. The angular dependence, on the other hand, is not affected by the amount of taper. The polarization of the radiation in the forward direction is determined by the transverse polarization of the undulator, but the polarization changes off axis. The radiation patterns predicted here are distinct from those of untapered undulators and their detection is now feasible. They will provide useful diagnostics of electron trajectories and threshold behavior in free-electron-laser oscillators using tapered undulators.

Bosco, P.↗

The precise computation of geoid undulation differences with comparison to results obtained from the global positioning system

Ellipsoidal height differences have been determined for 13 station pairs in the central Ohio region using measurements made with the Global Positioning System. This information was used to compute geoid undulation differences based on known orthometric heights. These differences were compared to gravimetrically-computed undulations (using a Stokes integration procedure, and least squares collocation having an internal r.m.s. agreement of plus or minus 1 cm in undulation differences). The two sets of undulation differences have an r.m.s. discrepancy of plus or minus 5 cm while the average station separation is of the order of 14 km. This good agreement suggests that gravimetric data can be used to compute accurate geoid undulation differences that can be used to convert ellipsoidal height differences obtained from GPS to orthometric height differences.

Engelis, T.↗

Geoid undulation computations at laser tracking stations

Geoid undulation computations were performed at 29 laser stations distributed around the world using a combination of terrestrial gravity data within a cap of radius 2 deg and a potential coefficient set up to 180 deg. The traditional methods of Stokes' and Meissl's modification together with the Molodenskii method and the modified Sjoberg method were applied. Performing numerical tests based on global error assumptions regarding the terrestrial data and the geopotential set it was concluded that the modified Sjoberg method is the most accurate and promising technique for geoid undulation computations. The numerical computations for the geoid undulations using all the four methods resulted in agreement with the ellipsoidal minus orthometric value of the undulations on the order of 60 cm or better for most of the laser stations in the eastern United States, Australia, Japan, Bermuda, and Europe. A systematic discrepancy of about 2 meters for most of the western United States stations was detected and verified by using two relatively independent data sets. For oceanic laser stations in the western Atlantic and Pacific oceans that have no terrestrial data available, the adjusted GEOS-3 and SEASAT altimeter data were used for the computation of the geoid undulation in a collocation method.

Despotakis, Vasilios K.↗