Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “unbalanced system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Combined Effects of Electric Vehicle Charging and Rooftop Solar Integration on Voltage Imbalance in Residential Distribution Networks

Residential electric vehicle (EV) chargers, as single phase loads, contribute to unbalanced voltage drops across phases, while rooftop solar systems, as single phase generators, can exacerbate voltage imbalance by causing unbalanced voltage increases. This paper investigates combined effects of residential EV charging and rooftop solar generation on voltage imbalance in residential distribution grids. The study examines these simultaneous impacts using the IEEE 8500-node test system, enhanced with a secondary network to realistically model the EV chargers and rooftop solar integration. To account for the variability and uncertainty in the EV charging loads and solar generation, a Monte Carlo approach is employed to capture and quantify the simultaneous impact of the EV charging and rooftop solar integration. In this approach, multiple influencing factors are considered, including state-of-charge (SOC), maximum charging power levels, and geographic distribution of chargers. The results provide practical insights for utilities and stakeholders, offering expectations for planning and operating strategies that effectively manage the increasing adoption of EVs and solar power while maintaining grid reliability.

Choi, Jongchan [ORNL] (ORCID:000000025952455X)↗

Geographically Distributed Co-Simulation for the Interplay of Integrated Energy Systems and Power Grid

The increased penetration of renewable generation induces unbalanced demand-supply on a power grid, while integrated energy systems (IES) can provide high part-load efficiency and high flexibility to support grid resilience. To study the transients and improve dynamic operability, it’s important to investigate the interplay between IES and power grid concurrently using real-time co-simulation approaches. In this presentation, we showed the previous co-simulation test between NETL and INL and discussed how this co-simulation can be beneficial for both IES and power grid research. In addition, we gave an overview about the SuperLab2.0 project, which was a federated national platform to address future power grid challenges. (Virtual presentation to the MILLENNIUM CLEAN and SUSTAINABLE POWER workshop 2025).

Co-simulation↗

An Admittance-Based Protection Scheme for Microgrids

This paper presents a novel directional protection scheme to address the unique challenges associated with protection during unbalanced faults in a distribution system with high penetration of inverter-based resources. The scheme is based on a superimposed negative sequence admittance method. A coordination approach using a unique inverse-time undervoltage element is also presented. An analysis of the scheme, the detection criteria and the coordination method are performed. Also the impact of inverter-control on the scheme is discussed. Results from extensive simulation using MATLAB/Simulink are presented to show a selective and reliable response of the scheme to unbalanced faults

Opoku, Kwasi↗

A Current Limiting Control Strategy for Single-Loop Droop-Controlled Grid-Forming Inverters Under Balanced and Unbalanced Faults

Existing studies reporting current limiting control strategies for grid-forming inverters primarily focus on grid-forming inverters that use a multi-loop control structure. This study reports a current limiting control for grid-forming inverters that uses a single-loop control structure. The proposed current limiting control was implemented at the pulse width modulation (PWM) control layer to guarantee a rapid response. Once an overcurrent caused by severe faults is detected, the proposed control strategy immediately blocks relevant insulated-gate bipolar transistors (IGBTs) using a hysteresis loop, ensuring that the overcurrent is limited within a few PWM cycles. After the fault is cleared, the inverter seamlessly transfers back to droop control mode to maintain stability. The current limiting control has been tested in a microgrid environment operating in the OPAL-RT platform. Study results show that the control strategy can effectively limit the overcurrent under both balanced and unbalanced faults and can maintain system transient stability after the fault is cleared.

Du, Wei↗

Validation of the Fault Ride-Through Response of a Generic EMT Inverter Model by Laboratory Testing

This paper presents the validation of the fault ride-through response of a large-scale inverter model using laboratory testing of a commercial inverter. First, we present the generic inverter model specifications. The generic inverter control is developed based on the fault ride-through response performance requirements of IEEE Std 2800-2022 for inverter-based resources. Next, we present laboratory tests that emulate voltages at the inverter terminal resulting from balanced and unbalanced faults on the transmission system. The tests are performed on a commercia12.2 MVA battery storage inverter at the U.S. National Renewable Energy Laboratory. Comparisons of the model's response to the laboratory measurements show the generic model presented can predict the controlled response of the commercial equipment. The differences between the model's response and the laboratory measurements during the initial transient at fault inception are discussed.

fault ride-through↗

Microgrid Service Restoration Incorporating Unmonitored Automatic Voltage Controllers and Net Metered Loads

Islanded microgrids may experience voltage and frequency instability due to uncontrolled state changes of voltage regulation devices and inaccurate demand forecasts. Uncontrolled state changes can occur if optimal microgrid restoration and dispatch algorithms, used for generating control commands for distributed energy resources, do not incorporate the behavior of automatic controllers of voltage regulation devices. Inaccurate demand forecasts may be encountered since post-outage demand of behind-the-meter net metered (NM) loads can vary significantly from their historical NM profiles. Here, this paper proposes an optimization formulation which allows optimal control of voltage regulators and capacitor banks without remote control and communication capabilities. A generalized demand model for NM loads is proposed which incorporates the cold load pickup phenomenon and their time varying post-outage demand in accordance with the IEEE 1547 standard. The time dependent optimal control formulation and the NM demand model are integrated in a sequential microgrid restoration algorithm by linearization of the involved logic propositions. A detailed case study on the unbalanced IEEE 123-node test system in OpenDSS validates the effectiveness of the proposed approach.

30 DIRECT ENERGY CONVERSION↗

Suspension system for gimbal supported scanning payloads

Gimballed scanning devices or instruments are the subject of this invention. Scanning is an important aspect of space science. To achieve a scan pattern some means must be provided which impart to the payload an oscillatory motion. Various forms of machines have been employed for controllably conferring on scanning instruments predetermined scan patterns. They include control moment gyroscopes, reaction wheels, torque motors, reaction control systems, and the like. But rotating unbalanced mass (RUM) devices are a new and efficient way to generate scans in gimballed payloads. RUM devices are superior to previous scanning apparatus, but they require power consuming and frequently complex auxiliary control systems to position and reposition the particular scan pattern relative to a target or a number of targets. Herein the control system is simplified. The most frequently employed method for achieving the various scan patterns is to gimbal the scanning device. Gimbals are suspended in such a way that they can be activated to generate the scan pattern. The suspension means described is for payloads supported in gimbals wherein the payload rotation is restricted by a flex pivot so that the payload oscillates, thereby moving in a scan pattern.

Polites, Michael E.↗

Processing of Signals from Fiber Bragg Gratings Using Unbalanced Interferometers

Fiber Bragg gratings (FBG) have become preferred sensory structures in fiber optic sensing system. High sensitivity, embedability, and multiplexing capabilities make FBGs superior to other sensor configurations. The main feature of FBGs is that they respond in the wavelength domain with the wavelength of the returned signal as the indicator of the measured parameter. The wavelength is then converted to optical intensity by a photodetector to detect corresponding changes in intensity. This wavelength-to-intensity conversion is a crucial part in any FBG-based sensing system. Among the various types of wavelength-to-intensity converters, unbalanced interferometers are especially attractive because of their small weight and volume, lack of moving parts, easy integration, and good stability. In this paper we investigate the applicability of unbalanced interferometers to analyze signals reflected from Bragg gratings. Analytical and experimental data are presented.

Adamovsky, Grigory↗

Operation and Control of a Back to Back Modular Multilevel Converter System for Grid Forming Application with Advanced Grid Support Functionalities

The main focus of this paper is to investigate the possibility of using modular multilevel converter based back-to-back system for grid forming applications. A decentralized hierarchical control architecture with a modified local controller based on nonlinear techniques for grid forming application have been investigated. Grid functionalities based on IEEE 1547-2018 for grid forming converters have been utilized. The local controllers ensure distortion free balanced sinusoidal output voltage on the grid forming side with unbalanced or nonlinear loading condition. The grid following side ensures unity power factor currents under unbalanced grid voltage condition. The dc bus voltage control ensures oscillation free voltage under balanced conditions and control of the average voltage under unbalanced condition. Efficacy of the overall system is verified by modeling the system in MATLAB/Simulink and PLECS domain and the most important case studies are presented.

advanced grid support functionalities↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters: Preprint

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

Experimental study on nanoparticle injection by using a lab-scale wellbore system

After long-term underground storage of CO 2 gas, leakage generated from the cement annulus in the wellbore system is often detected due to unbalanced pressure, chemical attack, etc. Here in this paper, nanoparticle injection technology is introduced to inject different types of nanoparticles into the cementitious material for repairing the leakage paths through electrochemical means. The pressure vessel is designed and built to provide a realistic underground environment with high pressure and high temperature. The testing results are evaluated by the saturate-drying method, charge-passed method, and X-ray microscopy (XRM) test. The results consistently show that all types of nanoparticles tested in this paper can be successfully driven into the cement annulus within the wellbore system. The pressure (6.89 MPa) and temperature (80 °C) in the pressure vessel, and the surrounding rock can directly affect the injection effectiveness. The nanoparticle injection technology is proven to be beneficial to the cracked cement annulus for preventing the leakage of CO 2 gas through the lab-scale wellbore system.

36 MATERIALS SCIENCE↗

Conceptual radiometer design studies for Earth observations from low Earth orbit

A conceptual radiometer design study was performed to determine the optimum design approach for spaceborne radiometers in low Earth orbit. Radiometric system configurations which included total power radiometers, unbalanced Dicke radiometers, and balanced Dicke, or as known as noise injection, radiometers were studied. Radiometer receiver configurations which were analyzed included the direct detection radiometer receiver, the double sideband homodyne radiometer receiver, and the single sideband heterodyne radiometer receiver. Radiometer system performance was also studied. This included radiometric sensitivity analysis of the three different radiometer system configurations studied. Both external and internal calibration techniques were analyzed. An accuracy analysis with and without mismatch losses was performed. It was determined that the balanced Dicke radiometer system configuration with direct detection receivers and external calibrations was optimum where frequent calibration such as once per minute were not feasible.

Harrington, Richard F.↗

Proposed solution methodology for the dynamically coupled nonlinear geared rotor mechanics equations

The equations which describe the three-dimensional motion of an unbalanced rigid disk in a shaft system are nonlinear and contain dynamic-coupling terms. Traditionally, investigators have used an order analysis to justify ignoring the nonlinear terms in the equations of motion, producing a set of linear equations. This paper will show that, when gears are included in such a rotor system, the nonlinear dynamic-coupling terms are potentially as large as the linear terms. Because of this, one must attempt to solve the nonlinear rotor mechanics equations. A solution methodology is investigated to obtain approximate steady-state solutions to these equations. As an example of the use of the technique, a simpler set of equations is solved and the results compared to numerical simulations. These equations represent the forced, steady-state response of a spring-supported pendulum. These equations were chosen because they contain the type of nonlinear terms found in the dynamically-coupled nonlinear rotor equations. The numerical simulations indicate this method is reasonably accurate even when the nonlinearities are large.

Mitchell, L. D.↗

A Modeling Toolkit for Comparing AC and DC Electrical Distribution Efficiency in Buildings

Recently, there has been considerable research interest in the potential for DC distribution systems in buildings instead of the traditional AC distribution systems. Due to the need for performing power conversions between DC and AC electricity, DC distribution may provide electrical efficiency advantages in some systems. To support comparative evaluations of AC-only, DC-only, and hybrid AC/DC distribution systems in buildings, a new modeling toolkit called the Building Electrical Efficiency Analysis Model (BEEAM) was developed and is described in this paper. To account for harmonics in currents or voltages arising from nonlinear devices, the toolkit implements harmonic power flow, along with nonlinear device behavioral descriptions derived from empirical measurements. This paper describes the framework, network equations, device representations, and an implementation of the toolkit in an open source software package, including a component library and graphical interface for creating circuits. Simulations of electrical behavior and device and system efficiencies using the toolkit are compared with experimental measurements of a small office environment in a variety of operating and load configurations. A detailed analysis of uncertainty estimation is also provided. Key findings were that a comparison of predicted versus measured efficiencies and power losses in the validation testbed using the initial toolkit implementation predicted device- and system-level efficiencies with reasonably good accuracy under both balanced and unbalanced AC scenarios. An uncertainty analysis also revealed that the maximum estimated error for system efficiency across all scenarios was 3%, and measured and modeled system efficiency agreed within the experimental uncertainty in approximately half of the scenarios. Based on the correspondence between simulation and measurement, the toolkit is proposed by the authors as a potentially useful tool for comparing efficiency in AC, DC, and hybrid AC/DC distribution systems in buildings.

DC distribution↗

Controls-structures-interaction dynamics during RCS control of the Orbiter/SRMS/SSF configuration

During the assembly flights of the Space Station Freedom (SSF), the Orbiter will either dock with the SSF and retract to the final berthed position, or will grapple the SSF using the Shuttle Remote Manipulator System (SRMS) and maneuver the SRMS coupled vehicles to their final berthed position. The SRMS method is expected to take approximately one to one and a half hours to complete and require periodic attitude corrections by either the Orbiter or the SSF reaction control system (RCS) or continuous control by a control moment gyro (CMG) system with RCS desaturation as required. Free drift of the attached vehicles is not currently thought to be acceptable because the desired system attitude will quickly deteriorate due to unbalanced gravity gradient and aerodynamic torques resulting in power generation problems, thermodynamic control problems, and communications problems. This paper deals with the simulation and control of the SRMS during trunnion/latch interaction dynamics and during RCS maneuvers. The SRMS servo drive joints have highly non-linear elastic characteristics which tend to degrade sensitive control strategies. In addition the system natural frequencies are extremely low and depend on the drive joint deflections and SRMS geometric position. The lowest mean period of oscillation for the Orbiter/SRMS/SSF(MB6) system in brakes hold mode positioned near the final berthed position is approximately 120 seconds. A detailed finite element model of the SRMS has been developed and used in a newly developed SRMS systems dynamics simulation to investigate the non-linear transient response dynamics of the Orbiter/SRMS/SSF systems. The present SRMS control strategy of brakes only recommended by the Charles Draper Labs is contrasted with a robust controller developed by the authors. The robust controller uses an optimal inear quadratic regulator (LQR) to optimally place the closed-loop poles of a multivariable continuous-time system within the common region of an open sector with the sector angle plus or minus 45 degrees from the negative real axis, and the left-hand side of a parallel to the imaginary axis in the complex s-plane. This guarantees that the critical damping ratio for the desired control modes is equal to or in excess of 0.707. The matrix sign function is used for solving the Riccati equations which appear in the controller design procedure. Fast and stable algorithms have recently been developed for the computation of the matrix sign function. Simulation results are given which demonstrate the potential CSI involvement for the current SRMS control system and the proposed control system.

Schliesing, J. A.↗

A Novel Grid-forming Voltage Control Strategy for Supplying Unbalanced Microgrid Loads Using Inverter-based Resources

This paper presents a novel grid-forming voltage control strategy for a battery energy storage system to maintain balanced three-phase output voltages when serving unbalanced loads. A stationary reference frame (αβ) based control scheme is proposed to regulate positive-sequence and negative-sequence voltages. Compared with the conventional rotating reference frame (dq) based control scheme, the proposed scheme shows better dynamic performance. Then, we analyze the system zero-sequence network and propose adding a grounding transformer to the Y/Yg connected output transformer to further reduce the voltage unbalance at the point of common coupling. The simulation results demonstrate the effective performance of the proposed voltage control scheme. Based on the results, the power-voltage unbalance curve is derived for different output transformer configurations to establish the relationship between the power unbalance limit and the voltage unbalance limit for microgrid power scheduling.

Xu, Bei↗