Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “turbine evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Active Aerodynamic Load Control for Wind Turbines

The goal of this project was to develop and demonstrate an advanced dielectric barrier discharge (DBD) plasma actuator technology. We set out to demonstrate the efficacy and impact of the new actuator technology as a key component of an active load control system for wind turbines. A DBD plasma actuator consists of a thin layer of dielectric material separating a pair of offset electrodes. One of those electrodes is embedded between the dielectric layer and a non-conductive substrate, while the other is exposed to air. When driven by an appropriate high voltage waveform, the device ionizes the air near the surface of the dielectric and adjacent to the exposed electrode. Collisions between the ions in the plasma and neutral air molecules result in a wall-jet – a region of induced air velocity that can be used to modify the flow around a lifting body. Use of the device near the trailing edge of a wind turbine blade, designed in such a way as to amplify the effects of the flow-modifying device, can result in large changes to the global forces experienced by the blade. Because of the fast response time of the device, it can allow the turbine to react in real time to changes in the wind associated with turbulence, wind shear, gusts, and the like, when paired with appropriate sensors and control algorithms. The goal of this project was to increase the capacity of the device to induce velocity on its surface at the levels required by large, utility-scale wind turbines. The first technical goal was to increase the induced velocity from the current industry-best of about 4 m/s to 10 m/s by modifying the electrical waveform used to drive the device and by introducing a semi-conductive surface coating to control electrostatic charge build-up on the surface. The second goal was to use the device to modify the lift on a representative airfoil in a wind tunnel, demonstrating a reduction in lift coefficient of 0.2 or better. The third goal was to produce an actuator-induced velocity of 20 m/s. Alongside our partners at the University of Texas at Dallas, we also applied modern, advanced design methods to optimize the impact of the technology on the design of wind turbines. We also had planned to install a segmented, active load control system on a test turbine to demonstrate the ability to reduce unsteady aerodynamic forces on the turbine associated with changes in the wind. The highest induced velocity achieved during this research was 11 m/s. However, practical design constraints limited the change in lift coefficient to about 0.12 for a representative airfoil in the wind tunnel at a Reynolds number of 400,000. The primary conclusion is that the plasma actuator control authority remains insufficient for practical purposes when extrapolated to Reynolds numbers over 1 million. The potential impact of the active lift control concept was evaluated through detailed simulations for three wind turbine sizes: a 3.4MW onshore turbine, a 10MW offshore turbine, and a 15MW offshore turbine. A feedback control system was designed for each turbine within two scenarios: one where the active lift control is used as a retrofit capability on the baseline design, and the other where the designers were permitted to “upscale” the turbines in order increase annual energy production. The levelized cost of energy was then evaluated for the range of turbine sizes and design configuration. It was found that the LCOE reduction associated with active lift control fell in the range of 0.7% to 7.2%, with the highest reduction associated with upscaling the 3.4MW turbine.

17 WIND ENERGY↗

Instantaneous mesh load factor ( K γ ) measurements in a wind turbine gearbox using fiber-optic strain sensors

The mesh load factor, K γ , describes how loads are shared between planet gears and has become one of the key design challenges in modern wind turbine gearboxes. Planet load sharing directly impacts tooth root stresses, a critical driver of torque density and gearbox reliability. Experimental evaluation of K γ is typically performed from sun gear tooth root strain gauge measurements, which are complex. Furthermore, such measurements can only provide an average value of load sharing. The present study describes an alternative method to evaluate the mesh load factor in wind turbine gearboxes based on fiber-optic strain sensors installed on the outer surface of the fixed ring gear. We present the results of an extensive measurement campaign to evaluate this novel sensing solution installed on the input planetary stage of a 2-MW wind turbine gearbox at the National Renewable Energy Laboratory's Flatirons Campus (Colorado, USA). The number of strain sensors on the ring gear was selected as an integer multiple of the number of planets, which has enabled an instantaneous evaluation of the mesh load factor. The effect of operating conditions on the planet load-sharing behavior of the gearbox has been investigated. The mesh load factor measured for operating conditions close to rated was below 1.05, well below IEC 61400-4 standard requirements.

17 WIND ENERGY↗

CFD Data on a Vertical Axis Wave Turbine

In this study January to July, 2023, different variations of the original geometry of a vertical-axis wave turbine (VAWT) were generated and evaluated for hydrodynamic power efficiency using computational fluid dynamics (CFD). The key geometrical parameters considered in this parametric study included the chord length of the rotor blades and the horizontal semi-axis length. The immersion depth of the rotor was also examined as a key deployment parameter for the wave turbine. The CFD simulation results revealed that a medium chord length of the blade (i.e., the same as that of the baseline design) and a shorter horizontal semi-axis for the guide curve of the blade than that of the baseline design resulted in higher hydrodynamic power to extract. With the most efficient turbine rotor geometry identified in this study, a deployment depth that could assure full submergence of the rotor in waves but as close to the free surface as possible led to a higher hydrodynamic power. These findings revealed a pathway for the improvement of the wave turbine energy efficiency.

16 TIDAL AND WAVE POWER↗

Implementation of a feature selection algorithm in FARM to identify important state variables and time-invariant matrices

The FARM (Feasible Actuator Range Modifier) software module is a component of the RAVEN-based FORCE framework for analysis of Integrated Energy Systems (IES). FARM aids the HERON software module in the evaluation of the optimal dispatch for the different IES components. Set-point trajectories are required to meet limits on both production variables (i.e., the variables to be optimized such as the electrical power, the hydrogen production rate, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). To evaluate the feasibility of HERON generated set-points and to do so in an acceptable time, FARM employs reduced order models to represent the dynamic behavior of the systems to be dispatched. These surrogate models take the form of a linear dynamic system with sets of Linear Parameter Varying (LPV) matrices that are mapped to the system operating space. These matrices are derived from the trajectories of system state variables and system output variables during transients. The accuracy of LPV matrices depends on the selection of state variables. In previous reports, state variables were selected by adopting a complicated workflow requiring multiple software licenses and an advanced level of user expertise. In this report, a new workflow that automates the state variable selection process is presented. It significantly reduces the frequency of user interventions and does not require multiple software licenses. Each module in the new workflow is described in detail, and the input / output examples in each step of the workflow are provided. It was demonstrated that this workflow can greatly reduce the complexity of the state variable selection process, and that the updated FARM-Gamma and FARM-Delta validators can benefit from this workflow when solving the power dispatch problem of a representative IES test case. Finally, some code improvements that can further enhance the efficiency are suggested.

42 ENGINEERING↗

Acoustic and Genetic Data Can Reduce Uncertainty Regarding Populations of Migratory Tree-Roosting Bats Impacted by Wind Energy

Wind turbine-related mortality may pose a population-level threat for migratory tree-roosting bats, such as the hoary bat (Lasiurus cinereus) in North America. These species are dispersed within their range, making it impractical to estimate census populations size using traditional survey methods. Nonetheless, understanding population size and trends is essential for evaluating and mitigating risk from wind turbine mortality. Using various sampling techniques, including systematic acoustic sampling and genetic analyses, we argue that building a weight of evidence regarding bat population status and trends is possible to (1) assess the sustainability of mortality associated with wind turbines; (2) determine the level of mitigation required; and (3) evaluate the effectiveness of mitigation measures to ensure population viability for these species. Long-term, systematic data collection remains the most viable option for reducing uncertainty regarding population trends for migratory tree-roosting bats. We recommend collecting acoustic data using the statistically robust North American Bat Monitoring Program (NABat) protocols and that genetic diversity is monitored at repeated time intervals to show species trends. There are no short-term actions to resolve these population-level questions; however, we discuss opportunities for relatively short-term investments that will lead to long-term success in reducing uncertainty.

17 WIND ENERGY↗

Validation of Computational Fluid Dynamics Simulations for Biological Performance Assessment in Hydropower units (Final Report)

The biological performance assessment (BioPA) toolset developed by Pacific Northwest National Laboratory (PNNL) estimates the relative biological performance of fish passage at a hydroelectric power turbine unit. The tool is based on the use of computational fluid dynamics (CFD) and fish biological response relationships. The recent release, BioPA-v3, is based on directly computed trajectory and collision of material Lagrangian particles using CFD simulation codes rather than the prior version that relies on Tecplot to compute streamtrace trajectories. Before modifying the toolset, a series of validation tests were performed at the various steps of modification in the toolset. Validation is a critical step of any numerical investigation that reflects the accuracy and reliability of the predicted results. It raises the confidence level of the user to use the modified version of the BioPA toolset. Several test cases were simulated and compared, where available, to observed data. The trajectory and collision of the small spherical and cylindrical particles in a water flume were compared to in-house experiments. The CFD predicted collision rate and flow field compared well with experimental observation for vane array and large cylinder as target bodies. Next, the CFD-predicted flow field and hydraulic performance of a laboratory-scale model of a Francis turbine was also successfully validated. Note that the trajectory of the particles is significantly affected by the flow field in such extreme conditions. In addition to the particle trajectories and flow field, the collision detection method employed in the CFD simulations was also successfully validated. The CFD predicted impact velocity, collision time, velocity, and trajectory of a sphere excellently matched with analytical value for a bouncing ball in the elastic collision. A similar approach was also tested and successfully validated for a collision of sphere with a 45° inclined plane. After successfully validating different cases, the BioPA toolset was modified to use direct output of the CFD prediction and the new version can be used in evaluating biological performance at hydroelectric turbines.

13 HYDRO ENERGY↗

Highly Available Nuclear Power for Mission-Critical Applications

Some energy consumers require power on an anytime, all-year-round basis with a high level of certainty, including defense installations, isolated communities, and some industrial processes. For these customers, interruptions in electricity or heat can mean substantial financial loss or even loss of life. In the absence of grid-scale energy storage, a high level of power availability can be accomplished only through the robustness and redundancy of power generators. The NuScale small modular reactor design is well suited to provide highly available power because of several features related to both the nuclear steam supply system and the overall plant design. In analogy to Redundant Array of Independent Disks (RAID) systems used to provide highly reliable data storage, a NuScale plant can assure sustained power generation by virtue of its Redundant Array of Integral Reactors (RAIR).This paper describes the NuScale RAIR plant features and summarizes the results of a rigorous analysis of RAIR availability as a function of power or, conversely, the RAIR plant output power as a function of power availability. The analysis utilized the Matrix Laboratory code (MATLAB) and included probability distributions for the frequency and duration of module outages due to planned and unplanned events. Further, the study evaluated the impact of implementing turbine bypass rather than module shutdown and using one or more modules to supply house loads in the case of loss of off-site power (LOOP). Availability results are presented for a 12-module RAIR plant with and without turbine bypass enabled during a LOOP and for different possible connections to the off-site power distribution grid and dedicated service loads. Results indicate that a very high level of availability can be achieved at relatively high power output levels, regardless of turbine bypass and dedicated load connection, compared to the operating fleet.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wind turbine gearbox fault prognosis using high-frequency SCADA data

Condition-based maintenance using routinely collected Supervisory Control and Data Acquisition (SCADA) data is a promising strategy to reduce downtime and costs associated with wind farm operations and maintenance. New approaches are continuously being developed to improve the condition monitoring for wind turbines. Development of normal behaviour models is a popular approach in studies using SCADA data. This paper first presents a data-driven framework to apply normal behaviour models using an artificial neural network approach for wind turbine gearbox prognostics. A one-class support vector machine classifier, combining different error parameters, is used to analyse the normal behaviour model error to develop a robust threshold to distinguish anomalous wind turbine operation. A detailed sensitivity study is then conducted to evaluate the potential of using high-frequency SCADA data for wind turbine gearbox prognostics. The results based on operational data from one wind turbine show that, compared to the conventionally used 10-min averaged SCADA data, the use of high-frequency data is valuable as it leads to improved prognostic predictions. High-frequency data provides more insights into the dynamics of the condition of the wind turbine components and can aid in earlier detection of faults.

17 WIND ENERGY↗

Evaluation of the potential for wake steering for U.S. land-based wind power plants

The wind power plant-wide control strategy known as wake steering involves the misalignment of upstream turbines with the wind direction to deflect wakes away from downstream turbines, increasing net wind plant power production. In this paper, we evaluate the potential of wake steering for U.S. land-based wind power plants. First, we outline a method for simulating and optimizing wake steering control for existing wind plants by combining the flow redirection and induction in steady state wake steering engineering model with the U.S. Wind Turbine Database and Wind Integration National Dataset Toolkit wind resource dataset. Next, to better understand the potential benefits of wake steering beyond those for existing wind plants, we evaluate the relative impacts of turbine specific power, turbine spacing, and mean wind speed on energy gain and levelized cost of energy (LCOE) using a model land-based wind power plant. For a subset of 60 existing wind plants, assuming a constant turbulence intensity of 8%, wake steering was found to yield an average annual energy production (AEP) gain of 0.80%, equivalent to recovering 13.85% of baseline wake losses. Further, we present a linear approximation between baseline wake losses and AEP gains that can be used to estimate wake steering gains for other wind power plants. Highlighting additional benefits of wake steering, for the model wind power plant we found that energy gains from wake steering enabled an approximate 30% reduction in turbine spacing while keeping LCOE constant.

17 WIND ENERGY↗

Assessment of Wind Energy Resource Potential for Future Human Missions to Mars

Energy sustainability and redundancy for surface habitats, life support systems and scientific instrumentation represent one of the highest-priority issues for future crewed missions to Mars. However, power sources utilized for the current class of robotic missions to Mars may be potentially dangerous near human surface habitats (for example, nuclear) or lack stability on diurnal or seasonal timescales (for example, solar) that cannot be easily compensated for by power storage. Here, we evaluate the power potential for wind turbines as an alternative energy resource on the Mars surface. Using a state-of-the-art Mars global climate model, we analyse the total planetary Martian wind potential and calculate its spatial and temporal variability. We find that wind speeds at some proposed landing sites are sufficiently fast to provide a stand-alone or complementary energy source to solar or nuclear power. While several regions show promising wind energy resource potential, other regions of scientific interest can be discarded based on the natural solar and wind energy potential alone. We demonstrate that wind energy compensates for diurnal and seasonal reductions in solar power particularly in regions of scientific merit in the midlatitudes and during regional dust storms. Critically, proposed turbines stabilize power production when combined with solar arrays, increasing the percent time that power exceeds estimated mission requirements from ~40% for solar arrays alone to greater than 60-90% across a broad fraction of the Mars surface. We encourage additional study aimed at advancing wind turbine technology to operate efficiently under Mars conditions and to extract more power from Mars winds.

atmospheric dynamics↗

Design and Evaluation of Environmental Barrier Coatings for Protection of Ceramic Matrix Composites in Hydrogen-Based Turbines

This presentation at the 2024 FECM Spring Project Review Meeting summarizes ongoing work at NETL aimed at enabling the use of ceramic matrix composite (CMC) materials in next-generation high-efficiency power generation turbines fueled by hydrogen, natural gas, or other fuels. The work broadly involves three aspects (1) phase-field damage modeling of CMCs and the environmental barrier coatings (EBCs) used to protect them (2) computational design of new and improved EBCs and (3) performance testing of EBCs using a novel gas turbine combustion simulation rig developed at NETL. An overview on current status and next steps for each aspect of the project are presented.

ceramic matrix composite (CMC)↗

Simulation of Peach Bottom turbine trip transient with RETRAN-3D using BXFGEN

The Peach Bottom 2 Turbine Trip transient is used to evaluate the capabilities and accuracy of coupled 3-D neutronics/thermal hydraulics best estimate calculations for support of safety analysis. Selected results, obtained with RETRAN-3D, are compared to available measurements and benchmark results. The comparisons are analyzed and the application of RETRAN-3D for a best estimate analysis approach within the safety analysis methodology is discussed. Overall, both the thermal-hydraulic and neutronic results show a good comparison to the experimental data, and the model is considered to accurately predict test data. In particular, the initial acoustic response of the main steam line and the subsequent main pressurization stages are well-predicted. During the main pressurization stage, the timing and magnitude of the in-core local pressurization and associated void compression are properly predicted based upon the agreement between local power range monitors (LPRM) predictions upwards, but the shift is slightly underpredicted. This indicates the methodology is well-posed for simulating this class of transient response.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TEAMER: Crossflow Turbine Fairing Geometry Optimization - Report and CFD Modeling Files

The dataset includes computational fluid dynamics (CFD) models and simulation files for crossflow turbines as well as a detailed project report. The report documents the project undertaken by the Ocean Renewable Power Company (ORPC) to design and optimize a modular fairing for the Modular RivGen Marine Hydrokinetic (MHK) turbine, which enhances the efficient deployment and operation of turbine arrays. The project focused on optimizing the hydrodynamic performance of the fairing using CFD, with an emphasis on two key geometric parameters: the fairing's cross-sectional shape and the spacing between the rotor and the fairing. The analysis aimed to maximize net power output while also assessing discretized loading to evaluate ultimate and fatigue loads on the turbine components. The numerical modeling was conducted using both the commercial CFD software Star-CCM+ and the open-source code openFOAM, with the latter utilizing the actuator line library, turbinesFOAM. This dual-code approach was intended to increase confidence in the results and demonstrate the viability of using open-source tools for high-fidelity marine energy modeling. This dataset includes all necessary files for actuator line simulations in openFOAM, as well as 2D blade-resolved CFD results, along with Python and Java scripts for setting up and post-processing simulations.

16 TIDAL AND WAVE POWER↗

Cybersecurity Center for Offshore Wind Energy (Final Project Report)

This project establishes a Cybersecurity Center for Offshore Wind Energy with the objective of designing and operating a cyber-physical testbed for wind energy farms (WEFs) that enables comprehensive cybersecurity research. The testbed incorporates a Supervisory Control and Data Acquisition (SCADA) system connected to turbine models via industrial-grade programmable logic controllers (PLCs) and remote terminal units (RTUs). It supports side-channel data acquisition, implementation and analysis of various cyberattack scenarios, and development of attack detection, mitigation, and best-practice guidance tailored to wind energy systems. During the project, the team expanded the number and fidelity of mathematical turbine models (MTMs), integrated these models with SCADA infrastructure, and deployed a scaled physical turbine and associated sensors. High-resolution operational and side-channel data streams were collected and used to refine machine-learning (ML)-based attack detection systems and to extend the WindCRAFT framework to multi-turbine threat scenarios. The project demonstrated a realistic, scalable environment for evaluating cyber threats, validated attack detection approaches using enriched datasets, and identified new multi-turbine and inter-turbine communication attack vectors. The resulting testbed, models, and security mechanisms provide a foundation for ongoing R&D and deployment of cyber-resilient offshore wind energy systems.

17 WIND ENERGY↗

Hydropower Biological Evaluation Toolset (HBET) Version 3.0: User Guide

The Hydropower Biological Evaluation Tools (HBET) software package, developed by Pacific Northwest National Laboratory (PNNL), is designed to assemble, organize, and process data collected by Sensor Fish and live fish. HBET enable users to characterize the hydraulic conditions of hydropower structures and estimate fish injury and mortality rates from various stressors. Future updates of the software may support other technologies, such as bead tracking in physical models and computational fluid dynamics. The HBET program can be customized to analyze different hydraulic applications, including turbines, spillways, weirs, pumped storage, and other user-defined functions, and therefore, help researchers, turbine designers, hydropower operators, and regulators better evaluate hydropower structures regarding their environmental sustainability and cost-effectiveness. Added content to the user guide about the new feature for predicting absolute injury rates.

13 HYDRO ENERGY↗

Advanced Laboratory and Field Arrays: Evaluating Sampling Techniques for MHK Biological Monitoring (Task 6)

The overall goal of the task was to identify cost effective biological sampling techniques for MHK environmental monitoring. Protected, demersal, and pelagic fish and selected nektonic invertebrates were surveyed using capture and remote sensing techniques at the PacWave sites. The performance of capture and remote sensing monitoring techniques were evaluated and generic nekton monitoring indices were developed for MHK technologies and sites. In parallel to data collections at the PacWave site, the ability of regression models to characterize, detect, and predict change in acoustic data was evaluated using acoustic data collected in Admiralty Inlet, WA, during a biological monitoring study of the proposed SnoPud tidal turbine project site. Expected outcomes of these efforts included an evaluation of instrumentation and techniques used to monitor biological variability; identification of data streams that can be used to detect and quantify change; and sampling requirements to ensure detection of change in monitored variables.

13 HYDRO ENERGY↗

A cross-sectional aeroelastic analysis and structural optimization tool for slender composite structures

A fully open-source available framework for the parametric cross-sectional analysis and design optimization of slender composite structures, such as helicopter or wind turbine blades, is presented. The framework—Structural Optimization and Aeroelastic Analysis (SONATA)—incorporates two structural solvers, the commercial tool VABS, and the novel open-source code ANBA4. SONATA also parameterizes the design inputs, postprocesses and visualizes the results, and generates the structural inputs to a variety of aeroelastic analysis tools. It is linked to the optimization library OpenMDAO. This work presents the methodology and explains the fundamental approaches of SONATA. Structural characteristics were successfully verified for both VABS and ANBA4 using box beam examples from literature, thereby verifying the parametric approach to generating the topology and mesh in a cross section as well as the solver integration. The framework was furthermore exercised by analyzing and evaluating a fully resolved highly flexible wind turbine blade. Computed structural characteristics correlated between VABS and ANBA4, including off-diagonal terms. Stresses, strains, and deformations were recovered from loads derived through coupling with aeroelastic analysis. The framework, therefore, proves effective in accurately analyzing and optimizing slender composite structures on a high-fidelity level that is close to a three-dimensional finite element model.

42 ENGINEERING↗