Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “trough”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Dynamic Wind Loading on CSP Collectors Caused by Turbulent Wind Fluctuations: Insights from a 2-Year Field Campaign

Concentrating Solar Power (CSP) is a promising solar technology for electricity generation with thermal energy storage and with the additional benefit of industrial heat production. Wind loading on CSP collector structures, such as parabolic troughs or heliostats, is one of the primary drivers of their structural design costs. In particular, dynamic wind loading is a major source of uncertainty in the collector design process, which heavily relies on wind tunnel testing. In the field, the turbulent nature of the incoming wind creates fluctuating loads (support structure loads and resulting mirror deflections) on the collectors, with impacts on fatigue lifetime and optical performance. As is well known, wind tunnel tests cannot entirely reproduce the complex turbulent wind conditions typically observed at full-scale plants. To shed light on this topic, NREL initiated a field campaign at the operational Nevada Solar One (NSO) powerplant that uses parabolic troughs as solar collectors. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs. We use the published 2-year dataset of high-resolution combined wind and structural loads measurements [1] to characterize the dynamic structural wind response. For quantifying dynamic wind loading, we apply the concept of admittance functions, which are spectral transfer functions that couple the turbulent wind to resulting structural loads (aerodynamic admittance), and to the structural response (mechanical admittance). In practice, aerodynamic admittance describes which turbulent eddy sizes are effective in creating structural loads. The mechanical admittance describes in which frequency ranges these loads are reinforced or dampened by the structure. While these functions are an established concept in civil engineering, their recent application to a single full-scale heliostat [2] proved their broader applicability to CSP collectors. Here, we present a characterization of admittance functions for full-scale parabolic trough collectors and show how wind characteristics (mean wind speed and direction, turbulent kinetic energy, turbulent length scales), the sun-tracking trough angle, and row position alter the admittance functions. Further, we study to which extent the admittance functions are universal for a specific trough geometry and how our findings compare to reported heliostat results. References [1] https://data.openei.org/submissions/5938. [2] Blume, K., Roger, M., and Pitz-Paal, R. 2023b. "Simplified analytical model to describe wind loads and wind-induced tracking deviations of heliostats." Solar Energy, 256, 96-109. https://doi.org/10.1016/j.solener.2023.03.055.

admittance functions↗

Temporal, Spatial, and Temperature Controls on Organic Carbon Mineralization and Methanogenesis in Arctic High-Centered Polygon Soils

Warming temperatures in continuous permafrost zones of the Arctic will alter both hydrological and geochemical soil conditions, which are strongly linked with heterotrophic microbial carbon (C) cycling. Heterogeneous permafrost landscapes are often dominated by polygonal features formed by expanding ice wedges: water accumulates in low centered polygons (LCPs), and water drains outward to surrounding troughs in high centered polygons (HCPs). These geospatial differences in hydrology cause gradients in biogeochemistry, soil C storage potential, and thermal properties. Presently, data quantifying carbon dioxide (CO 2 ) and methane (CH 4 ) release from HCP soils are needed to support modeling and evaluation of warming-induced CO 2 and CH 4 fluxes from tundra soils. This study quantifies the distribution of microbial CO 2 and CH 4 release in HCPs over a range of temperatures and draws comparisons to previous LCP studies. Arctic tundra soils were initially characterized for geochemical and hydraulic properties. Laboratory incubations at −2, +4, and +8°C were used to quantify temporal trends in CO 2 and CH 4 production from homogenized active layer organic and mineral soils in HCP centers and troughs, and methanogen abundance was estimated from mcrA gene measurements. Results showed that soil water availability, organic C, and redox conditions influence temporal dynamics and magnitude of gas production from HCP active layer soils during warming. At early incubation times (2–9 days), higher CO 2 emissions were observed from HCP trough soils than from HCP center soils, but increased CO 2 production occurred in center soils at later times (>20 days). HCP center soils did not support methanogenesis, but CH 4 -producing trough soils did indicate methanogen presence. Consistent with previous LCP studies, HCP organic soils showed increased CO 2 and CH 4 production with elevated water content, but HCP trough mineral soils produced more CH 4 than LCP mineral soils. HCP mineral soils also released substantial CO 2 but did not show a strong trend in CO 2 and CH 4 release with water content. Knowledge of temporal and spatial variability in microbial C mineralization rates of Arctic soils in response to warming are key to constraining uncertainties in predictive climate models.

59 BASIC BIOLOGICAL SCIENCES↗

Tornadoes in Southeast South America: Mesoscale to Planetary-Scale Environments

Abstract A multiscale analysis of the environment supporting tornadoes in southeast South America (SESA) was conducted based on a self-constructed database of 74 reports. Composites of environmental and convective parameters from ERA5 were generated relative to tornado events. The distribution of the reported tornadoes maximizes over the Argentine plains, while events are rare close to the Andes and south of Sierras de Córdoba. Events are relatively common in all seasons except in winter. Proximity environment evolution shows enhanced instability, deep-layer vertical wind shear, storm-relative helicity, reduced convective inhibition, and a lowered lifting condensation level before or during the development of tornadic storms in SESA. No consistent signal in low-level wind shear is seen during tornado occurrence. However, a curved hodograph with counterclockwise rotation is present. The Significant Tornado Parameter (STP) is also maximized prior to tornadogenesis, most strongly associated with enhanced CAPE. Differences in the convective environment between tornadoes in SESA and the U.S. Great Plains are discussed. On the synoptic scale, tornado events are associated with a strong anomalous trough crossing the southern Andes that triggers lee cyclogenesis, subsequently enhancing the South American low-level jet (SALLJ) that increases moisture advection to support deep convection. This synoptic trough also enhances vertical shear that, along with enhanced instability, sustains organized convection capable of producing tornadic storms. At planetary scales, the tornadic environment is modulated by Rossby wave trains that appear to be forced by convection near northern Australia. Madden–Julian oscillation phase 3 preferentially occurs 1–2 weeks ahead of tornado occurrence. Significance Statement The main goal of this study is to describe what atmospheric conditions (from local to global scales) are present prior to and during tornadic storms impacting southeast South America (SESA). Increasing potential for deep convection, wind shear, and potential for rotating updrafts, as well as reducing convective inhibition and cloud-base height, are predominant a few hours before and during the events in connection to low-level northerly winds enhancing moisture transport to the region. Remote convective activity near northern Australia appears to influence large-scale atmospheric circulation that subsequently triggers convective storms supporting tornadogenesis 1–2 weeks later in SESA. Our findings highlight the importance of accounting for atmospheric processes occurring at different scales to understand and predict tornado occurrences.

Meteorology & Atmospheric Sciences↗

Linking large-scale weather patterns to observed and modeled turbine hub-height winds offshore of the US West Coast

The US West Coast holds great potential for wind power generation, although its potential varies due to the complex coastal climate. Characterizing and modeling turbine hub-height winds under different weather conditions are vital for wind resource assessment and management. This study uses a two-stage machine learning algorithm to identify five large-scale meteorological patterns (LSMPs): post-trough, post-ridge, pre-ridge, pre-trough, and California high. The LSMPs are linked to offshore wind patterns, specifically at lidar buoy locations within lease areas for future wind farm development off Humboldt and Morro Bay. While each LSMP is associated with characteristic large-scale atmospheric conditions and corresponding differences in wind direction, diurnal variation, and jet features at the two lidar sites, substantial variability in wind speeds can still occur within each LSMP. Wind speeds at Humboldt increase during the post-trough, pre-ridge, and California-high LSMPs and decrease during the remaining LSMPs. Morro Bay has smaller responses in mean speeds, showing increased wind speed during the post-trough and California-high LSMPs. Besides the LSMPs, local factors, including the land–sea thermal contrast and topography, also modify mean winds and diurnal variation. The High-Resolution Rapid Refresh model analysis does a good job of capturing the mean and variation at Humboldt but produces large biases at Morro Bay, particularly during the pre-ridge and California-high LSMPs. The findings are anticipated to guide the selection of cases for studying the influence of specific large-scale and local factors on California offshore winds and to contribute to refining numerical weather prediction models, thereby enhancing the efficiency and reliability of offshore wind energy production.

17 WIND ENERGY↗

Wildfire towers drive firebrand lofting: insights from coupled fire-atmosphere model simulations

Wildfire behavior is shaped by complex fire dynamics, with firebrands playing a critical role in spot fire ignition and fire spread. While previous studies have explored firebrand generation and transport, the specific role of towers and troughs from wildland fires in the lofting of firebrands remains unquantified. This study addresses that gap by using physics-based coupled fire-atmosphere model simulations to examine how wildfire towers (updrafts) and troughs (downdrafts) influence firebrand lofting. Our results show that the majority of firebrands (78.85%) are lofted from towers, where strong updrafts drive long-range transport. In contrast, only 21.15% of firebrands are lofted within troughs, where downdrafts cause most firebrands to fall near the fireline. We also find that firebrand size significantly influences lofting behavior, with smaller particles (1 mm radius) exhibiting the strongest correlation with updraft intensity. These findings highlight the dominant role of wildfire towers in promoting long-distance firebrand dispersal—an essential factor in rapid wildfire growth and wildland-urban interface (WUI) fire risks. By quantifying the relationship between firebrand lofting and fire-induced atmospheric features, this study provides critical insights to improve spot fire modeling, support mitigation planning, and enhance firefighter and WUI community safety in spot fire-prone regions.

54 ENVIRONMENTAL SCIENCES↗

Acciona Power Plant Hydrogen Mitigation Project

In 2014, Acciona Solar Power and the National Renewable Energy Laboratory initiated discussions to identify a method to solve a long-standing efficiency loss problem at parabolic trough power plants. Parabolic trough power plants begin to show lost thermal efficiency after six years of operation, due to the presence of trace concentrations of hydrogen in the heat transfer fluid that circulates in the power plant. Trace levels of hydrogen infiltrate the collector field receivers, increasing their heat loss, and decreasing the power plants’ thermal efficiency. At the time, Acciona’s Nevada Solar One power plant in Boulder City, Nevada was starting to show this efficiency loss. After several discussions, APS and NREL agreed to a collaborative effort (CRADA) to develop and implement a method to reduce hydrogen levels in the circulating HTF at the NSO power plant. The project was planned as a three-year effort, and work started in June 2015. The CRADA’s goal was to solve the long-standing lost efficiency problem caused by the buildup of hydrogen in the HTF, which significantly impacts the efficiency, electricity generation, and revenue from parabolic trough power plants.

08 HYDROGEN↗

Hybrid Solar System (Final Scientific/Technical Report)

GTI Energy (GTI) teamed with the University of California at Merced (UCM) to scaleup the hybrid solar system (HSS) technology for demonstrating its performance at the US Gypsum (USG) plant in Plaster City, California. The technology integrates two-stage concentrating solar collector with matching particle thermal transport and storage (TSS) system to deliver cost-effective, and on-demand distributed high temperature industrial process heat up to 600°C with solar thermal, in this case to a gypsum kettle, to reduce its fuel use and carbon footprint. Current solar technologies, which reach these temperatures, are not distributable (towers) or cost-effective (dish). The research team developed a conceptual system design for host site retrofit, including preliminary heat balance, process flow diagram, particle to process heat exchanger and equipment placements at the site. Subsequently, parallel efforts were carried out at UCM to design, build and test a 12 m long commercial scale prototype concentrating thermal-only collector system and at GTI to design, build and test a matching 650°C capable particle TTS system. The nominal 50 kWth collector consists of a parabolic trough and three 4 m long two-stage receivers in series. Prior to on-sun testing, a 4 m long receiver was fabricated and successfully tested at 650 °C in a laboratory setting for 100 hrs of continuous operation showing less than 15% radiation loss. A 7 m wide x 17 m long parabolic trough was then installed at UCM for on-sun testing of the 12 m long receiver, and concurrently several 4 m long receivers were built. The optics of the parabolic trough were calibrated, and on-sun test were carried out on 12 m long receivers. During tests, the intense solar radiation (53x) caused the absorber tubes in the receivers to bend, reducing the overall optical efficiency. To address the bending issue, a self-consistent algorithm that includes ray tracing, thermal and deformation models was developed to perform thermal stress analysis on absorbers for parabolic solar collectors. Results obtained with this algorithm showed a dramatic rise in deformation as absorber tube length increases. A combined efficiency parameter that includes the occluded area for the mounts was developed to obtain an optimized tube length obtained. Based on the results, a length of 2.7 m for the absorber + 0.2 m for the coupler was chosen to minimize any bending and optimize optical efficiency while maintaining ease of mounting. The associated particle TTS system was designed, built and successfully tested at GTI. It includes storage, receiving and lock hoppers and piping that simulates the transfer of captured solar energy to an actual industrial furnace. Tests over 77 charge-discharge cycles demonstrated <2% particle degradation, with no problematic particle accumulations and no flow interruptions. The piping pressure drop was about 5 psi. The team also worked with Stanley Consultants (Stanley) to prepare conceptual and preliminary engineering packages to facilitate follow-on development and commercialization efforts. These include process and instrumentation diagram’s (P&ID’s), general arrangements, electrical one-line, project definitions document, equipment data sheets, schedule, and construction cost estimate for 2 MWth system. Updated HSS technology commercialization and customer engagement plans and detailed costs and evaluated market trade-offs and manufacturing.

03 NATURAL GAS↗

Wind Loading on CSP Collectors

The project significantly enhanced the community's understanding of the fundamental physics drivers underlying the wind-loading experienced by concentrating solar power (CSP) collector structures (i.e., parabolic troughs and heliostats) as well as their support structures. This project had two overarching objectives: (1) detailed measurements to characterize the prevailing wind conditions and resulting operational loads on collector structures, and (2) development and validation of a computationally efficient, high-fidelity modeling tool capable of predicting wind-loading in deep-array installations. Over three years, we conducted comprehensive at-scale field measurements of the atmospheric turbulent wind conditions, and the resulting wind loads on parabolic troughs and heliostats. Two at-scale measurement campaigns yielded first-of-its-kind, high-resolution, long-term datasets that are used to characterize the complex flow field and wind loading on parabolic-troughs and heliostats in operational power plants. The high-resolution measurements collected during these campaigns were used to validate the high-fidelity computational models developed at NREL. These open-source computationally efficient models were shown to be accurate in predicting wind-driven loads on collectors without the need for a large supercomputer.

14 SOLAR ENERGY↗

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects (Final Technical Report)

The number of commercial coal, gas, and nuclear projects built over the past 100 years number in the thousands. As such, there is a large database, available to a wide range of commercial engineering contractors, on proven designs. In essence, unsuccessful designs have, through generations of iterations, been identified and then deleted from further consideration. In contrast, the number of commercial parabolic trough projects using nitrate salt for the thermal storage media is perhaps 60. Further, the number of commercial central receiver projects using nitrate salt as the working fluid is on the order of 20, including estimates for China. Given the relative immaturity of salt technology, and commercial pressures to successfully bid new solar projects into a mature electricity market, solar projects often promise more than has been delivered. The Design Basis Document / Owner’s Technical Specification is a first step in the iteration process. The report describes the successful features of commercial projects, outlines a range equipment and system failures in projects that didn’t operate as intended, and provides a draft set of design changes intended to correct the known problems. The product of the study is 3 volumes of technical material; one volume is on parabolic trough technologies; a second is on central receiver technologies, and the third is on potential design changes to parabolic trough and central receiver projects. The 3 volumes, which total some 590 pages, can be found at https://www.solardynllc.com/csp-plant-technologies. One of the principal topics in the report is the use of functional or prescriptive specifications. Functional specifications describe what the equipment needs to do, consistent with the minimum legal requirements of the local jurisdictions. The details of how this is to be accomplished is developed by the engineering contractor. Prescriptive specifications, which are developed by the Owner, prescribe to the engineering contractor how the functional requirements are to be met. This arrangement ensures that the favorable experience from a previous project is repeated. One example is the design code for the hot salt tank in central receiver projects. The closest design basis is API Standard 650 Welded Steel Tanks for Oil Storage. However, the maximum design temperature in API 650 is 260 °C. As such, solar projects have typically adopted a hybrid Code approach, in which allowable material stresses are taken from ASME Section II Materials. Further, since the tanks experience daily changes in temperature and in (static) pressure, and since portions of the tank can operate at stresses beyond the elastic range, the low cycle fatigue life of the tank is conducted using the rules of Section VIII Division 2. However, in a recent study by NREL, the principal damage mechanism was identified as creep rather than fatigue. Further, design stresses permitted under Section VIII Division 2, corresponding to a fatigue life of 30 years, result in projected creep lifetimes of only 2 to 5 years. An alternate design approach, prescribed by the Owner, would be based on Code sections intended for high temperature service in the creep regime. A candidate is Section III Division 5. Granted, this is a nuclear code section, and it’s use would not likely be mandated by local jurisdictions. However, the effects of creep have been deemed to be of sufficient importance that one nuclear project developer, and one central receiver project developer, have stipulated in the tank design specification that the equipment be designed to the requirements of Section III Division 5.

14 SOLAR ENERGY↗

Linking Synoptic Patterns to Cloud Properties and Local Circulations Over Southeastern Texas

This report classifies meteorological regimes in the southeastern Texas region to identify environmental conditions that favor sea-breeze induced convection. The classification is accomplished using a Self-Organizing Map (SOM) approach. We applied SOM to 10 years of 700-hPa geopotential height anomalies during the summer months from reanalysis data to distinguish three dominant synoptic regimes, with a continuum of transitional states between those. The primary regimes include: (a) a pre-trough regime associated with a synoptic trough, (b) a post-trough regime with upper-level northerly flow, and (c) an anticyclonic regime within the westward extent of the Bermuda High. We project the data from the Geostationary Operational Environmental Satellite and the Next Generation Weather Radar system onto each SOM node to investigate the characteristics of cloud and precipitation properties in different regimes. When southeastern Texas is positioned to the southwest quadrant of a maritime high pressure system, an increased cloud frequency is observed over the region during the afternoon hours due to significant moisture advection. A confluence of synoptic southerly flow and sea-breeze circulation commonly occurs in this regime. When a high pressure system is over southeastern Texas, the area is dominated by large-scale subsidence with weak pressure gradients and moderate precipitable water vapor. This weak synoptic forcing is favorable for the formation of a sea-breeze circulation. This is confirmed by an enhanced onshore flow and a decreased temperature at the surface in the early afternoon, as well as a sharp increase in radar echo top height.

54 ENVIRONMENTAL SCIENCES↗

Role of Three-Dimensional Swirl in Forced Convection Heat Transfer Enhancement in Wavy-Plate-Fin Channels

The influence of wall-corrugation-induced swirl flow on enhanced forced convection in wavy-plate-fin cores has been investigated. Three-dimensional computational simulations were carried out for steady-state periodically developed air flow (Pr ~ 0.71; 50 ≤ Re ≤ 4000) with channel walls subject to constant-uniform temperature conditions. The recirculation that develops in the wall troughs and grows to have an axially helical character is scaled by the Swirl number Sw. As Sw increases with higher flowrate and/or corrugation severity, tornado-shaped vortices appear in the wave trough region midway of the interfin channel height, then extend longitudinally to encompass majority of the flow channel. The local wall-shear and heat transfer coefficient variations indicate that boundary-layer thinning upstream of the wave peak aids in intensifying momentum and heat transfer. However, the flow recirculation in wall trough impedes heat transfer at low Sw due to flow stagnation but promotes it at high Sw because of the vortices-induced augmented fluid mixing. The effects of this secondary flow are quantified by Φf(or j), which is seen to increase log-linearly as fin corrugation aspect ratio γ and/or fin spacing ratio ζ increases; the influence of cross section aspect ratio α is marginal. Moreover, the pressure drag penalty due to swirl critically affects overall pressure loss, and its proportion remains nearly constant when α varies, but grows as Sw, γ, and/or ζ increases and can be as much as 80% of the total pressure drop.

Engineering↗

NSO Processing Scripts (NSO wind loading data set processing scripts) [SWR-23-86]

NREL conducted comprehensive field measurements of the atmospheric turbulent wind conditions and the resulting structural wind loads on parabolic troughs at the Nevada Solar One plant from October 2021 to June, 2023. The measurement set-up included meteorological masts and structural load sensors on four trough rows. Additionally, NREL commissioned a lidar scanning the horizontal plane over the trough field. The high-resolution data set, characterizing the complex flow field and resulting structural loads, is available at https://data.openei.org/submissions/5938. The processing routines published here were used to create the data from the instruments' raw data.

Egerer, Ulrike↗

Understanding Observed Precipitation Change and the New Climate Normal from the Perspective of Daily Weather Types in the Southeast United States

Abstract Observed precipitation changes in the Southeast United States (SEUS) are spatially heterogeneous. Most of the inland SEUS and eastern Gulf Coast become drier, and the East Coast north of Charleston, South Carolina, and southern Florida become wetter from the old 30-yr period of 1961–90 to the recent period of 1991–2020. The observed climate change is examined from the perspective of daily weather types (WTs). A k -means clustering analysis has been conducted using daily 850-hPa circulation for 1948–2021. The obtained 10 WTs peak in different seasons, respectively. The frequencies and precipitation intensity of the WTs have been analyzed. A winter WT characterized by a western Appalachian trough (WAT) and a summer WT featuring North Atlantic subtropical high (NASH) have a rising trend of annual frequency from 1948 to 2021. An Appalachian high in the autumn has a decreasing frequency but becomes drier and stronger. Some precipitation intensity change and small location shift have also been observed. The drying up on the eastern Gulf Coast and the inland area of the SEUS is mainly caused by the weakened southwesterly low-level jet (LLJ) on the western flank of the NASH that reduces rain in the spring, the less frequent but stronger and drier Appalachian high in the summer and autumn, and the weaker and more western located Plains trough (PT) in the winter, spring, and autumn. The precipitation increase in the East Coast and southern Florida is majorly due to more frequent, stronger, and rainier troughs along the western Appalachian as well as the East Coast.

Qian, Jian-Hua↗

Studying Wind Loading on CSP Collectors to Improve Performance and Reliability

Electricity generation through Concentrating Solar-thermal Power (CSP) adds the advantage of thermal energy storage and heat production. CSP collector costs constitute nearly one-third of total plant costs. Managing wind loading, especially dynamic wind loading caused by the turbulent wind flow, is a significant design challenge. Traditional collector designs rely on wind tunnel experiments and numerical simulations, which do not fully capture dynamic effects. Here, we provide an overview of NREL's activities on wind loading on CSP collectors, aiming to improve their reliability and cost-efficiency. We present insights from field measurements at operational parabolic trough and power-tower CSP plants. Over two years, we measured turbulent wind fields and resulting structural loads in a parabolic trough plant, revealing wind, turbulence, and collector field interactions. Similar measurements are ongoing at the Crescent Dunes heliostat field. These campaigns show how atmospheric turbulence, wind direction, and collector orientation affect dynamic wind loading. Upwind collector structures can generate turbulent structures, causing fluctuating loads at downstream collectors, impacting fatigue lifetime and optical efficiency. Preliminary results indicate that interior collectors experience higher turning moments than those at the edges, suggesting higher drive wear. At Crescent Dunes, we use instrumented heliostats at the field's edge and interior to study the translation of turbulent wind to dynamic structural loads. The campaign is still ongoing, and we will present first findings. Another focus of our work is tying the experimental wind loading findings to optical performance of the collectors, using simulation tools. For example, we derive torsional errors of the parabolic troughs - the angular offset from the sun position along a collector row. This error is impacted by wind-induced mirror deformations. Future work will focus on continuing the measurement efforts and combining them with computational fluid dynamic simulations. By providing detailed field measurements and validated models, our efforts aim to enhance understanding of wind loading on CSP collectors, improving their structural integrity and optical performance.

CSP↗

Concentrating Solar Power Best Practices Study

The primary objective of this Concentrating Solar Power Best Practices Study is to publish best practices and lessons learned from the engineering, construction, commissioning, operations, and maintenance of existing concentrating solar power (CSP) parabolic trough and power tower systems. To accomplish this objective, information was solicited from many owners, operators, and engineering, procurement, and construction (EPC) contractors, independent engineers, and other stakeholders of parabolic trough and central receiver plants (also commonly referred to as power towers). Information was gathered through in-person or online meetings, site visits, and questionnaires sent to participants. The project team held about 50 information-gathering sessions with participants over the course this effort; and in the process, it collected information from participants representing nearly 80% of CSP plants operating worldwide.

14 SOLAR ENERGY↗

Anisotropic Optical and Frictional Properties of Langmuir–Blodgett Film Consisting of Uniaxially-Aligned Rod-Shaped Cellulose Nanocrystals

Langmuir–Blodgett (LB) film deposition gives an opportunity to control the packing density and orientation of anisotropic nanoparticles at a monolayer level, allowing accurate characterization of their anisotropic material properties. Additionally, the uniaxial deposition of rod-shaped cellulose nanocrystals (CNCs) over a macroscopically large area is achieved by aligning the long axis of CNCs on the LB trough with the direction of the maximum drag force within the meniscus during the vertical pulling of the substrate from the LB trough. On the uniaxially-aligned LB films, anisotropic linear and non-linear optical properties of CNCs are obtained using Mueller matrix spectroscopy and sum frequency generation spectroscopy, respectively, and explained with time-dependent density functional theory calculations. Also, the frictional anisotropy of the LB film is measured using atomic force microscopy and explained theoretically. The findings of this study will be valuable for preparation of anisotropic nanoparticle thin films with uniform arrangements and utilization of their anisotropic material properties.

36 MATERIALS SCIENCE↗