Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transition operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Utility Microgrid Controller Test Plan

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) DER. In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this first edition report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing the distribution grid resilience using cyber-physical oriented islanding strategy

The increasing penetration of distributed generations enables an innovative operation paradigm that allows islanded operation to enhance the resilience of the distribution grid. In this study, a cyber-physical oriented islanding strategy is proposed by coordinating centralised and distributed control to achieve seamless islanding transition and operational flexibility in emergency conditions. A cyber-physical control structure is developed to mitigate various disturbances (e.g. emergencies or fluctuations) according to different operation conditions. Specifically, the distributed fault isolation and seamless islanding transition are coordinated to mitigate the outage caused by unplanned islanding, while a secondary control is proposed to support primary control by reducing the power fluctuations during islanded operation. With a rapid response speed, the local cyber-physical devices are coordinated to accomplish islanding separation by selecting a feasible islanded area even under an unplanned islanding situation. A field test was conducted on a practical distribution network in China, and the results demonstrated the effectiveness and feasibility of the proposed islanding strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Adaptive Virtual Oscillator Control Structure for Grid-Forming Inverters

The electrical grid is facing unprecedented challenges due to the increasing penetration of inverter-based resources. Grid forming inverters (GFMIs) are a promising technology to address these challenges. Recently, the virtual oscillator based GFMI control is attracting more attention due to its superior performance over other control strategies. In this article, an adaptive control strategy is proposed to provide flexible operation and transition between grid-connected and islanded modes. The controller adapts the virtual oscillator's parameter values depending on the operation mode. It also provides a feedback signal using a measured frequency to account for any steady-state errors and to allow a seamless transition from grid-connected to islanded mode. Finally, to show the feasibility of the proposed controller, this article discusses the simulation results from the implementation of the controller on a single inverter system and on a group of inverters on a large practical utility feeder, the IEEE 13 node feeder, using the DIgSILENT simulation environment.

adaptive control↗

Hourly Load Profile Dataset for Electric Transit Bus Depots in the United States

Transit buses operate primarily in dense urban areas, where nearby populations face increased exposure to fine particulates, nitrogen oxides, and other harmful pollutants. Electrifying transit buses presents a clear opportunity to reduce greenhouse gas emissions and improve urban air quality. However, widespread adoption may pose significant energy and infrastructure challenges, which can be mitigated through proactive planning and investment. This report presents a robust modeling framework and an initial estimation of the hourly electricity demand at transit bus depots across the United States. The resulting depot-level dataset, available at data.nrel.gov/submissions/282, provides valuable insights for infrastructure planning and electricity demand forecasting, supporting the scalable electrification of transit bus fleets nationwide.

33 ADVANCED PROPULSION SYSTEMS↗

Neutrino Dipole Moments and Radiative Signatures from Partial Compositeness

We investigate composite neutrino models where heavy neutrinos emerge as bound states from a near-conformal strongly coupled sector. Standard Model neutrinos mix with these composite singlets via an inverse seesaw mechanism, where the anomalous scaling dimensions of the composite-sector operators naturally suppress light neutrino masses to sub-eV scales. Matching the conformal dynamics onto low-energy theory yields enhanced electromagnetic transition dipole operators with couplings $d_{μN} \sim 10^{-6}$-$10^{-8}\,\mathrm{GeV}^{-1}$, parametrically larger than the loop-level predictions of minimal Dirac or Majorana models. We carry out a dedicated event-level simulation of the production-and-decay chain $νX \to \mathcal{U} X \to νγX$ and compute the resulting event rates at MiniBooNE and MINERvA within the model, accounting for the composite production cross section and decay kinematics in detail. We further present predictions for the photon energy, angular, and multiplicity distributions. For the benchmark scenarios accessible at these experiments the radiative signal is predominantly single-photon; the composite structure additionally permits fragmentation of the up-scattered state into multiple heavy neutrinos, each decaying as $N\toνγ$, with multi-photon final states emerging for lighter compositeness scales or higher beam energies as a qualitatively new probe of the composite dynamics.

Assi, Benoît [Cincinnati U.; Fermilab] (ORCID:0000↗

Long Beach Transit Battery Electric Bus Evaluation (Final Report)

Beginning in March 2017, Long Beach Transit began operating a fleet of 10 battery electric buses (BEBs) in its service area in Southern California. These electric buses, produced by BYD, are 40-foot buses that are typically charged overnight. Long Beach Transit is collaborating with the California Air Resources Board (CARB) and the U.S. Department of Energy’s National Renewable Energy Laboratory (NREL) to evaluate the buses in revenue service. NREL evaluated the first year of Long Beach Transit’s BEB fleet under Federal Transit Administration funding and published a report covering results from January 2018 through December 2018. CARB provided funding to cover a second year of evaluation. This report provides an update to the previous reports and is focused on the second year of operation from January 2019 through December 2019. Data are provided on a selection of compressed natural gas (CNG) buses as a baseline comparison.

33 ADVANCED PROPULSION SYSTEMS↗

Is Clean Hydrogen Production a Good Fit for Questa? (Final Economic Impact Results) [Slides]

The Village of Questa, New Mexico is aiming to become a regional clean energy hub with robust and diverse employment opportunities for the local community supported by the energy sector and by other businesses inspired or attracted by abundant clean energy, outdoor recreation, and cultural opportunities. A coalition of stakeholders in the Village of Questa, comprising the Village, Kit Carson Electric Cooperative (KCEC), Questa Economic Development Fund, and Chevron, is exploring options to develop hydrogen production facilities as an opportunity to create jobs, provide reliable clean energy, and utilize former mine resources. Questa is home to a molybdenum mine owned by Chevron that closed in 2014. Several residents in Questa and surrounding communities lost their jobs when the mine closed and transitioned from active operations into environmental remediation. Although remediation efforts have been ongoing since 2014 and are expected to continue for at least 16 more years, the number of jobs with Chevron is much smaller now than it was before the closure. Between available workforce, brownfield land, and water rights formerly supporting mine operations but now in a transition period, there are considerable local resources that could be directed toward clean energy generation. Questa's electricity supply is already 100% solar during daylight hours thanks to Kit Carson Electric Cooperative's (KCEC's) strategic decision-making and partnering over the last decade. Now, Questa, KCEC, and Chevron are exploring the potential costs and benefits of siting an electrolytic hydrogen production facility and additional solar photovoltaic (PV) capacity in Questa to further advance the region's clean energy economy. In this report, we estimated the potential economic impacts (i.e., jobs, value added, gross output, tax revenue) of constructing and operating a combined hydrogen (32 MW polymer electrolyte membrane electrolizer + 7.5 MW fuel cell) and solar facility (22.5 MW) in the Village of Questa, as well as the resulting economic spillovers to Taos County and the state of New Mexico. We employ an input-output model that leverages IMPLAN's economic data for the region complemented by construction and operating expenses estimated by NREL and feedback from the local coalition to evaluate the direct, indirect and induced effects of the project construction (transient impacts) and operation (more permanent impacts). Based on the area's average trade profile, feedback from the coalition and current market conditions, these projects are expected to support 487 full-time equivalent jobs during construction, generating $\$24$ million in income for those workers and $\$82$ million in local economic activity in the state. Of those jobs, 106 are expected to be construction sector jobs. These investments are also estimated to add $\$36.5$ million to New Mexico's gross state product (GSP). In the Village of Questa, we estimate 16 jobs will be supported in construction and transportation industries, generating $\$0.9$ million in earnings. In Taos County, the construction phase is expected to support 285 jobs primarily in construction and professional services, while manufacturing jobs dominate the results for the Rest of New Mexico. The Village is also estimated to receive $\$0.9$ million in tax revenue from the construction phase alone. Once in operation, the project continues to impact the state and Questa. Around 20 jobs (full-time equivalent for each year of operation) are supported across New Mexico, with approximately 11 directly employed in Questa by both facilities. The total annual local economic activity supported by ongoing operations is just over $\$1.3$ million/yr, generating $\$1.6$ million/yr in additional income in the state. Annual operations are estimated to add $\$2.1$ million to the state's GSP. The Village is expected to receive around $\$43,000$/yr in tax revenue. Impacts vary significantly depending on which businesses are supplying materials, equipment and services, and where construction workers reside. Choosing local suppliers will most benefit Questa and the New Mexico economy, adding up to 500 jobs during construction and 13 long-term jobs. Local and state governments may consider ways to incentivize local businesses in order to maximize economic benefits.

08 HYDROGEN↗

Is Clean Hydrogen Production a Good Fit for Questa? Final Economic Impact Results

The Village of Questa, New Mexico is aiming to become a regional clean energy hub with robust and diverse employment opportunities for the local community supported by the energy sector and by other businesses inspired or attracted by abundant clean energy, outdoor recreation, and cultural opportunities. A coalition of stakeholders in the Village of Questa, comprising the Village, Kit Carson Electric Cooperative (KCEC), Questa Economic Development Fund, and Chevron, is exploring options to develop hydrogen production facilities as an opportunity to create jobs, provide reliable clean energy, and utilize former mine resources. Questa is home to a molybdenum mine owned by Chevron that closed in 2014. Several residents in Questa and surrounding communities lost their jobs when the mine closed and transitioned from active operations into environmental remediation. Although remediation efforts have been ongoing since 2014 and are expected to continue for at least 16 more years, the number of jobs with Chevron is much smaller now than it was before the closure. Between available workforce, brownfield land, and water rights formerly supporting mine operations but now in a transition period, there are considerable local resources that could be directed toward clean energy generation. Questa's electricity supply is already 100% solar during daylight hours thanks to Kit Carson Electric Cooperative's (KCEC's) strategic decision-making and partnering over the last decade. Now, Questa, KCEC, and Chevron are exploring the potential costs and benefits of siting an electrolytic hydrogen production facility and additional solar photovoltaic (PV) capacity in Questa to further advance the region's clean energy economy. In this report, we estimated the potential economic impacts (i.e., jobs, value added, gross output, tax revenue) of constructing and operating a combined hydrogen (32 MW polymer electrolyte membrane electrolizer + 7.5 MW fuel cell) and solar facility (22.5 MW) in the Village of Questa, as well as the resulting economic spillovers to Taos County and the state of New Mexico. We employ an input-output model that leverages IMPLAN's economic data for the region complemented by construction and operating expenses estimated by NREL and feedback from the local coalition to evaluate the direct, indirect and induced effects of the project construction (transient impacts) and operation (more permanent impacts). Based on the area's average trade profile, feedback from the coalition and current market conditions, these projects are expected to support 487 full-time equivalent jobs during construction, generating $\$24$ million in income for those workers and $\$82$ million in local economic activity in the state. Of those jobs, 106 are expected to be construction sector jobs. These investments are also estimated to add $\$36.5$ million to New Mexico's gross state product (GSP). In the Village of Questa, we estimate 16 jobs will be supported in construction and transportation industries, generating $\$0.9$ million in earnings. In Taos County, the construction phase is expected to support 285 jobs primarily in construction and professional services, while manufacturing jobs dominate the results for the Rest of New Mexico. The Village is also estimated to receive $\$0.9$ million in tax revenue from the construction phase alone. Once in operation, the project continues to impact the state and Questa. Around 20 jobs (full-time equivalent for each year of operation) are supported across New Mexico, with approximately 11 directly employed in Questa by both facilities. The total annual local economic activity supported by ongoing operations is just over $\$1.3$ million/yr, generating $\$1.6$ million/yr in additional income in the state. Annual operations are estimated to add $\$2.1$ million to the state's GSP. The Village is expected to receive around $\$43,000$/yr in tax revenue. Impacts vary significantly depending on which businesses are supplying materials, equipment and services, and where construction workers reside. Choosing local suppliers will most benefit Questa and the New Mexico economy, adding up to 500 jobs during construction and 13 long-term jobs. Local and state governments may consider ways to incentivize local businesses in order to maximize economic benefits.

08 HYDROGEN↗

An Innovative Energy Management System for Microgrids with Multiple Grid-Forming Inverters

As increasingly more grid-forming (GFM) inverter-based resources replace traditional fossil-fueled synchronous generators as the GFM sources in microgrids, the existing microgrid energy management systems (EMS) need to be updated to control and coordinate multiple GFM inverters that consider system control objectives under different microgrid connection states.For each state, we formulate an optimization problem and apply a real-time feedback-based control algorithm; altogether, the control algorithms seamlessly connect the states into a generic microgrid EMS that controls the nodal voltages and frequencies, becomes a virtual power plant (VPP) when connected to the main grid, and coordinates power sharing responsibility among GFM sources when islanded. We showcase the EMS on a real-world simulation of a microgrid under the different states to demonstrate its operational effectiveness.

energy management system↗

State Machine Operation of Complex Systems

Operation of complex systems which depend on one or more other systems with many process variables often operate in more than one state. For each state there may be a variety of parameters of interest, and for each of these, one may require different alarm limits, different archiving needs, and have different critical parameters. Relying on operators to reliably change 10s-1000s of parameters for each system for each state is unreasonable. Not changing these parameters results in alarms being ignored or disabled, critical changes missed, and/or possible data archiving problems. To reliably manage the operation of complex systems, such as cryomodules (CMs), Fermilab is implementing state machines for each CM and an over-arching state machine for the PIP-II superconducting linac (SCL). The state machine transitions and operating parameters are stored/restored to/from a configuration database. Proper implementation of the state machines will not only ensure safe and reliable operation of the CMs, but will help ensure reliable data quality. A description of PIP-II SCL, details of the state machines, and lessons learned from limited use of the state machines in recent CM testing will be discussed.

43 PARTICLE ACCELERATORS↗

State Machine Operation of Complex Systems

Operation of complex systems which depend on one or more other systems with many process variables often operate in more than one state. For each state there may be a variety of parameters of interest, and for each of these, one may require different alarm limits, different archiving needs, and have different critical parameters. Relying on operators to reliably change 10s-1000s of parameters for each system for each state is unreasonable.Not changing these parameters results in alarms being ignored or disabled, critical changes missed, and/or possible data archiving problems.To reliably manage the operation of complex systems, such as cryomodules (CMs), Fermilab is implementing state machines for each CM and an over-arching state machine for the PIP-II superconducting linac (SCL). The state machine transitions and operating parameters are stored/restored to/from a configuration database. Proper implementation of the state machines will not only ensure safe and reliable operation of the CMs, but will help ensure reliable data quality. A description of PIP-II SCL, details of the state machines, and lessons learned from limited use of the state machines in recent CM testing will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

State Machine Operation of Complex Systems

Operation of complex systems which depend on one, or more, sub-systems with many process variables often operate in more than one state. For each state there may be a variety of parameters of interest, and for each of these, one may require different alarm limits, different archiving needs, and have different critical parameters. Relying on operators to reliably change 102-105 parameters for each system for each state is unreasonable. Not changing these parameters results in alarms being ignored or disabled, critical changes missed, and/or data archiving inefficiencies. To reliably manage the operation of complex systems, such as cryomodules (CMs), Fermilab is implementing state machines for each CM and an over-arching state machine for the PIP-II superconducting LINAC (SCL). The state machine transitions and operating parameters are stored/restored to/from a configuration database. Proper implementation of the state machines will not only ensure safe and reliable operation of the CMs, but will help ensure reliable data quality. A description of PIP-II SCL, details of the state machines, and plans for imminent use the state machines for CM testing will be discussed.

43 PARTICLE ACCELERATORS↗

OB200-DV-1 Treatability Testing: Final Results

The Hanford Site in Washington state previously generated plutonium for nuclear weapons. During operations, radionuclide byproducts and chemical process fluids were intentionally and/or unintentionally released to the subsurface, resulting in more than 800 contaminated waste sites across the Central Plateau, where historical chemical separations and waste management activities took place. As the Hanford Site mission transitioned from operations to site cleanup, remediation of the vadose zone and groundwater became a priority. However, given the depth of the unsaturated zone contamination above the groundwater, the unique nature of the waste, and the continuing impacts on groundwater quality, technologies needed to be identified and evaluated for in situ remediation in the deep vadose zone (DVZ). A laboratory treatability study has been completed to evaluate site-relevant effectiveness for nine in situ technologies that may be used to treat continuing sources of contaminants in specific areas of the Central Plateau waste sites that are grouped into the 200-DV-1 Operable Unit (OU). The 200-DV-1 OU was established in 2010 to address 43 Central Plateau waste sites with complex DVZ remediation challenges. Eight of these technologies were identified through a prescreening effort that evaluated remedial technologies potentially applicable to DVZ contamination in the Central Plateau . These eight technologies were selected for further study based on site specific knowledge gaps about their effectiveness. A ninth technology was added to the treatability study based on new information from separate laboratory investigations (conducted following the prescreening effort) demonstrating the technology’s potential effectiveness (see Section 1.2 for more information) and value for inclusion in the treatability study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments

This study conducts hardware experiments to assess the performance of a commercial single-phase grid-forming (GFM) inverter using a purely hardware-based approach. We adhere to a testing protocol for the GFM inverter and enhance it by exploring the transient performance of GFM inverters across various grid dynamic events. Quantifiable performance metrics are established for each testing scenario to gain insights into the performance of the single-phase GFM inverters. Based on the comprehensive tests, the following observations are summarized: 1) The performance of the single-phase GFM inverter is satisfactory, and it is capable of being the islanding master for residence homes when the main grid is gone. 2) For frequency response, the inverter is able to stay connected but cannot inject the needed active power to support the grid. This may be improved by the manufacturer by using droop control. 3) The GFM inverter exhibits harmful transients in voltage and frequency during islanding operation, which can be enhanced by maintaining the same operating points before and after the breaker is open.

dynamic performance↗

Design of a Two-Body Wave Energy Converter Featuring Controllable Geometry

While the field of wave energy has been the subject of numerical simulation, scale model testing, and precommercial project testing for decades, wave energy technologies remain in the early stages of development and must continue to prove themselves as a promising modern renewable energy field. A wave energy converter (WEC) concept currently being explored is the variable-geometry WEC (VGWEC), which aims to add an extra control option to WEC design. VGWECs attempt to incorporate controllable geometric features to adjust the floating body hydrodynamics to favor either power absorption, load shedding, or other operational goals. These variable geometry components have been proposed to be controlled on a sea-state-to-sea-state or wave-to-wave time scale depending on the force (or torque) and bandwidth limitations of the actuators required to manipulate just the controllable geometric hull features. Having control over both the WEC geometry components and the power takeoff (PTO) offers the potential to improve overall system performance and reliability if a cost-effective solution can be found for a given WEC architecture. This paper will present the recent developments and results of a VGWEC concept that incorporates variable-geometry modules into a two-body WEC. In the proposed VGWEC concept, the variable-geometry modules consist of air-inflatable bags in the surface float and a water inflatable ring in the subsurface body. The surface float is tethered directly to the subsurface body through tether lines, each connected to a separate PTO. Adjusting the geometry of both the surface and subsurface bodies along with the PTO coefficients can maximize power in design sea states while reducing motion response and PTO forces when transitioning to sea states where rated power is reached and load shedding is prioritized. The ability to transition between operating condition is expected to increase the sea state operational map and power capacity.

geometry control↗

An Environmental and Societal Analysis of the US Electrical Energy Industry Based on the Water–Energy Nexus

To meet rising energy demands, power plant operations will expand, influencing the interactions between the water–energy nexus and society. However, a major challenge is integration of social dimensions within electricity generation. To address this, we generate a baseline dataset using US public data (2014–2019) from the Energy Information Administration and US Bureau of Labor Statistics. We identify the rate of energy consumed, CO 2 , SO 2 and NO x emissions generated, and water used per MWh net electricity as well as employee wellbeing per unit MW capacity during electricity generation. Rates of energy consumption (MMBtu/MWh) decreased 4.9%, but water consumption and withdrawal (m 3 /MWh) both increased 0.93% and 0.31%, respectively. Emissions of CO 2 , SO 2 and NO x decreased 22.64%, 75% and 25% MT/MWh, respectively. Thermoelectric cooling withdrawal and consumption is led by natural gas (50.07%, 38.31%), coal (29.61%, 25.07%), and nuclear energies (13.55%, 18.99%). Electric power generation contributes 0.06 injuries–illnesses/TWh and 0.001 fatalities/TWh, of which fossil fuels contributed 70% and 15%, respectively. Fossil fuels led in average annual employment (0.02 employees/MW) with low cost salaries (USD 0.09/MW) likely due to high collective capacity, which is declining. Estimated rates in this study and framework will aid power industry transition and operational decision makers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of a Microgrid System with Grid-Forming and Grid-Following Inverters with Diesel Generators: Insights From Hardware Experiments

This paper presents a comprehensive performance evaluation of a microgrid system integrating grid-forming (GFM) inverters, grid-following (GFL) inverters, and a diesel generator, focusing on their interactions and behavior under various dynamic events. The study is conducted using a pure hardware setup comprising two GFM inverters, one GFL inverter, a diesel generator, load banks, a point of common coupling (PCC), and an emulated main grid. The evaluation specifically examines dynamic scenarios, including voltage jumps, phase jumps, rate of change of frequency (ROCOF), synchronization, and islanding operations, which pose critical challenges to system stability. Among all the tests conducted, the overloading and phase jump tests proved to be the most challenging. The capacity of the DC side is crucial for withstanding overloading and grid disturbance tests; otherwise, GFM inverters frequently trip due to DC undervoltage. Throughout all grid disturbance tests, the diesel generator consistently stands out as the most robust and reliable GFM unit in the system. Overall, insights from these hardware experiments shed light on the response characteristics of different generation types during grid disturbances and identify potential stability concerns in such hybrid microgrid systems.

14 SOLAR ENERGY↗

Debunking common myths in coastal circulation modeling

Despite tremendous progress in algorithm development, computational efficiency and transition into operations over the past two decades, coastal modeling still lacks scientific rigor due to proliferation of many ‘gray’ areas related to various modeling choices made by modelers. Here, in this paper, we propose some guiding principles for the modeling community to improve performance, and we also debunk commonly held myths that make the coastal modeling lack rigor. Using our own experience in developing seamless cross-scale unstructured-grid based models for the past two decades, we describe in unprecedented detail the end-to-end modeling process (i.e., from digital elevation models (DEMs) to mesh generation to post analysis), and demonstrate that defensible modeling is within reach for any end user by following three guiding principles: (1) Bathymetry is a first order forcing in coastal domains and thus should be respected in all aspects of modeling; (2) Oceanographic processes are driven across multiple spatial scales and so models should enable appropriate resolution as needed; and (3) Model assessment should focus on physical processes. Through qualitative and quantitative model assessments, we demonstrate the fundamental role played by bathymetry/topography as embedded in DEMs in making the results defensible, which is unfortunately glossed over in many modeling studies. Focusing on process-based assessment simplifies the calibration process. A major conclusion of this work is that model developers and operators should maximize the scientific rigor for in silico oceanography by avoiding some common pitfalls that rely on error compensation at the expense of representation of physical system processes. We present some best practice procedures for defensive and trustworthy numerical modeling.

54 ENVIRONMENTAL SCIENCES↗