Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transient storage model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Large Scale Cryogenic Storage with Active Refrigeration

Storage and transfer of cryogenic liquefied gases on volume scales from under 10 liters for lab use, up to hundreds of millions of liters for industrial applications is of paramount importance across a vast range of industries. Traditionally, these commodities have been stored at or near the normal boiling point due to relative ease of operation and safety-related considerations; however, this also means that some percentage will always be lost due to environmental heat leaking into the vessel and causing boil-off. These losses become more concerning as scales increase, and are of particular importance for high-cost commodities such helium and hydrogen. Additionally, the normal boiling point marks the highest liquid density achievable; which becomes a strong driver of end-use system designs such as space launch vehicles. Recent development and testing of an Integrated Refrigeration and Storage (IRAS) system for liquid hydrogen has proven that next generation cryogenic storage operations such as zero boil-off and densification are feasible on a large scale. This IRAS system married an 850 Watt at 20 Kelvin reverse-Brayton cycle commercial cryogenic refrigerator with a 125,000 liter LH2 storage tank via and internal tubular heat exchanger. This allowed heat to be removed directly from the hydrogen, and by extension, provided a means to control the bulk thermodynamic state. Zero boil-off, in-situ liquefaction, and densification down to the triple point was performed during testing, and data such as fluid temperature profiles and tank pressure were gathered. Details regarding the design, setup, and testing of the IRAS system are discussed herein, and the data used to anchor various physics models created to predict the behavior of the system during transient and steady state operation. It is hoped that these efforts will provide a useful basis for the design and implementation of future large scale IRAS systems across numerous industries.

Swanger, Adam M.↗

Ventless pressure control of two-phase propellant tanks in microgravity

This work studies pressurization and pressure control of a large liquid hydrogen storage tank. A finite element model is developed that couples a lumped thermodynamic formulation for the vapor region with a complete solution of the Navier-Stokes and energy equations for the flow and temperature fields in the liquid. Numerical results show that buoyancy effects are strong, even in microgravity, and can reposition a vapor bubble that is initially at the center of the tank to a region near the tank wall in a relatively short time. Long-term tank pressurization with the vapor bubble at the tank wall shows that after an initial transient lasting about a week, the final rate of pressure increase agrees with a purely thermodynamic analysis of the entire tank. However, the final pressure levels are quite different from thermodynamic predictions. Numerical results also show that there is significant thermal stratification in the liquid due to the effects of natural convection. A subcooled jet is used to provide simultaneous cooling and mixing in order to bring the tank pressure back down to its initial value. Three different jet speeds are examined. Although the lowest jet speed is ineffective at controlling the pressure because of insufficient penetration into the liquid region, the highest jet speed is shown to be quite effective at disrupting thermal stratification and reducing the tank pressure in reasonable time.

Weightlessness↗

Spray Bar Zero-Gravity Vent System for On-Orbit Liquid Hydrogen Storage

During zero-gravity orbital cryogenic propulsion operations, a thermodynamic vent system (TVS) concept is expected to maintain tank pressure control without propellant resettling. In this case, a longitudinal spray bar mixer system, coupled with a Joule-Thompson (J-T) valve and heat exchanger, was evaluated in a series of TVS tests using the 18 cu m multipurpose hydrogen test bed. Tests performed at fill levels of 90, 50, and 25 percent, coupled with heat tank leaks of about 20 and 50 W, successfully demonstrated tank pressure control within a 7-kPa band. Based on limited testing, the presence of helium constrained the energy exchange between the gaseous and liquid hydrogen (LH2) during the mixing cycles. A transient analytical model, formulated to characterize TVS performance, was used to correlate the test data. During self-pressurization cycles following tank lockup, the model predicted faster pressure rise rates than were measured; however, once the system entered the cyclic self-pressurization/mixing/venting operational mode, the modeled and measured data were quite similar. During a special test at the 25-percent fill level, the J-T valve was allowed to remain open and successfully reduced the bulk LH2 saturation pressure from 133 to 70 kPa in 188 min.

Hastings, L. J.↗

Lubrication of nonconformal contacts

Minimum film thickness results for piezoviscous-rigid regime of lubrication are developed for a compressible Newtonian fluid with Roelands viscosity. The results provide a basis for the analysis and design of a wide range of machine elements operating in the piezoviscous-rigid regime of lubrication. A new numerical method of calculating elastic deformation in contact stresses is developed using a biquadratic polynomial to approximate the pressure distribution on the whole domain analyzed. The deformation of every node is expressed as a linear combination of the nodal pressures whose coefficients can be combined into an influence coefficient matrix. This approach has the advantages of improved numerical accuracy, less computing time and smaller storage size required for influence matrix. The ideal elastohydrodynamic lubrication is extended to real bearing systems in order to gain an understanding of failure mechanisms in machine elements. The improved elastic deformation calculation is successfully incorporated into the EHL numerical scheme. Using this revised numerical technique and the flow factor model developed by Patir and Cheng (1978) the surface roughness effects on the elastohydrodynamic lubrication of point contact is considered. Conditions typical of an EHL contact in the piezoviscous-elastic regime entrained in pure rolling are investigated. Results are compared with the smooth surface solutions. Experiments are conducted to study the transient EHL effects in instrument ball bearings.

Jeng, Y. R.↗

Validation of Cryogenic Propellant Tank Self-Pressurization

NASA’s near-future long-term space missions necessitate advancements in cryogenic fluid management (CFM), which includes safe and reliable long-term propellant storage. Consequently, NASA STMD (Space Technology Mission Directorate) has established the CFM Portfolio Project to improve CFM technologies for upcoming missions. As a part of CFM Modeling Portfolio, NASA Marshall Space Flight Center’s (MSFC) Fluid Dynamics branch within the Propulsion Systems Department is tasked with assessing and improving computational tools used to support flight projects such as Human Lander System and Commercial Lunar Payload Services. One of the challenging modeling problems is that of self-pressurization of propellant tank due to heat leakage over long time periods. Reduced order and nodal tools find it extremely difficult to accurately predict self-pressurization under transient conditions or where complex flow patterns or thermal gradients exist, and application of 3-D CFD (computational fluid dynamics) simulations is necessary to characterize these problems. Until recently, CFD simulations for these long-term processes (order of hours or days) have been too impractical to conduct due to prohibitive wall time and computational resource requirements. The requisite CFD tool need to be efficient, computationally scalable, modular with ability to incorporate various physics models, and robust enough to not accumulate conservation errors over several hours of simulated time. NASA MSFC’s Loci-Stream CFD tool along with the VOF module is a great candidate to fit this mold. In this paper, we validate Loci-Stream for predicting self-pressurization of a flight scale propellant tank so it can serve as a reliable design and analysis tool for NASA’s CFM application needs. Liquid hydrogen tank pressurization tests carried out at the K-site testing facility provide a reliable data set for this purpose. These tests were simulated using Loci-Stream solver with VOF module as well as a hybrid approach which uses a lumped model for the ullage gas domain and CFD simulation of the liquid propellant. Both are shown to have very good predictive capabilities over multiple K-site experiments.

Hong Q. Yang↗

Validation of Cryogenic Propellant Tank Self-Pressurization

NASA's near-future long-term space missions necessitate advancements in cryogenic fluid management (CFM), which includes safe and reliable long-term propellant storage. Consequently, NASA STMD (Space Technology Mission Directorate) has established the CFM Portfolio Project to improve CFM technologies for upcoming missions. As a part of CFM Modeling Portfolio, NASA Marshall Space Flight Center's (MSFC) Fluid Dynamics branch within the Propulsion Systems Department is tasked with assessing and improving computational tools used to support flight projects such as Human Lander System and Commercial Lunar Payload Services. One of the challenging modeling problems is that of self-pressurization of propellant tank due to heat leakage over long time periods. Reduced order and nodal tools find it extremely difficult to accurately predict self-pressurization under transient conditions or where complex flow patterns or thermal gradients exist, and application of 3-D CFD (computational fluid dynamics) simulations is necessary to characterize these problems. Until recently, CFD simulations for these long-term processes (order of hours or days) have been too impractical to conduct due to prohibitive wall time and computational resource requirements. The requisite CFD tool need to be efficient, computationally scalable, modular with ability to incorporate various physics models, and robust enough to not accumulate conservation errors over several hours of simulated time. NASA MSFC's Loci-Stream CFD tool along with the VOF module is a great candidate to fit this mold. In this paper, we validate Loci-Stream for predicting self-pressurization of a flight scale propellant tank so it can serve as a reliable design and analysis tool for NASA's CFM application needs. Liquid hydrogen tank pressurization tests carried out at the K-site testing facility provide a reliable data set for this purpose. These tests were simulated using Loci-Stream solver with VOF module as well as a hybrid approach which uses a lumped model for the ullage gas domain and CFD simulation of the liquid propellant. Both are shown to have very good predictive capabilities over multiple K-site experiments.

cryogenic fluid management↗

Numerical analysis of flow and heat transfer in the VAFB LOX storage Dewar tank

The present report describes numerical simulation of three-dimensional transient distributions of velocity and temperature of liquid oxygen (LOX) in the LOX Dewar tank of Vendenberg Air Force Base (VAFB). The present analyses cover the replenish time period only. Four test cases have been considered. For all four cases, the input boundary conditions are comprised of LOX facility heat loads, drain flow rates, recirculation flow rates and dewar heating. All the quantities are prescribed as functions of time. The first two test cases considered sensitivity of results to the computational grid. In Case 3, system heat load was changed, while in Case 4, a lower LOX level was specified. Cases 1 and 2 showed that the temperatures were not sensitive to the grid refinement. This provided a basic check on the numerical model. Cases 3 and 4 showed that the thermal boundary layer motion near the tank surface becomes more significant at the late time, e.g., 5 1/2 hours from replenish start. Comparison between results of Cases 3 and 4 showed, as expected, that the smaller initial LOX volume given in Case 4, results in higher temperature level. All calculated velocity and temperature distributions were found to be plausible.

Tam, L. T.↗

Numerical Determination of Critical Conditions for Thermal Ignition

The determination of ignition or thermal explosion in an oxidizing porous body of material, as described by a dimensionless reaction-diffusion equation of the form .tu = .2u + .e-1/u over the bounded region O, is critically reexamined from a modern perspective using numerical methodologies. First, the classic stationary model is revisited to establish the proper reference frame for the steady-state solution space, and it is demonstrated how the resulting nonlinear two-point boundary value problem can be reexpressed as an initial value problem for a system of first-order differential equations, which may be readily solved using standard algorithms. Then, the numerical procedure is implemented and thoroughly validated against previous computational results based on sophisticated path-following techniques. Next, the transient nonstationary model is attacked, and the full nonlinear form of the reaction-diffusion equation, including a generalized convective boundary condition, is discretized and expressed as a system of linear algebraic equations. The numerical methodology is implemented as a computer algorithm, and validation computations are carried out as a prelude to a broad-ranging evaluation of the assembly problem and identification of the watershed critical initial temperature conditions for thermal ignition. This numerical methodology is then used as the basis for studying the relationship between the shape of the critical initial temperature distribution and the corresponding spatial moments of its energy content integral and an attempt to forge a fundamental conjecture governing this relation. Finally, the effects of dynamic boundary conditions on the classic storage problem are investigated and the groundwork is laid for the development of an approximate solution methodology based on adaptation of the standard stationary model.

Luo, W.↗

Simulations of Zero Boiloff, Densification, and Solidification in a Large-Scale Liquid Hydrogen Tank

The current research utilizes an Energy of Fluid (EOF) approach to develop a finite volume-based Computation Fluid Dynamic (CFD) model to create a benchmark simulation of the densification of liquid hydrogen (LH2) in an experimental Integrated Refrigeration and Storage (IRAS) tank at the Kennedy Space Center (KSC). The computational code will incorporate the FLUENT pressure-based model with User Defined Functions (UDF) to implement the EOF model. The enhanced model will solve the energy equation in terms of internal energy and provide temperature and pressure calculations for a given tank geometry. Specifically, a convection term will be added to an already existing code for a more accurate simulation of LH2 densification. However, currently the research focuses on utilizing User Defined Scalars (UDS) with FLUENT to show the built-in solvers are as accurate as the written UDS. This will reduce the computational time down significantly by utilizing an already built in solver for the momentum equation. A custom UDF has been written to solve transient and steady state conduction, and results obtained using the UDF agree with results obtained using the built-in FLUENT solver. Currently, a convection UDF is being added and will be verified using known solutions for solidification and validated with the experimental results from the Cryogenics Test Laboratory (CTL) at KSC for the IRAS densification process.

Colin Philip Mahony↗

The Zero Boil-Off Tank Experiment Contributions to the Development of Cryogenic Fluid Management

The Zero Boil-Off Technology (ZBOT) Experiment involves performing a small scale ISS experiment to study tank pressurization and pressure control in microgravity. The ZBOT experiment consists of a vacuum jacketed test tank filled with an inert fluorocarbon simulant liquid. Heaters and thermo-electric coolers are used in conjunction with an axial jet mixer flow loop to study a range of thermal conditions within the tank. The objective is to provide a high quality database of low gravity fluid motions and thermal transients which will be used to validate Computational Fluid Dynamic (CFD) modeling. This CFD can then be used in turn to predict behavior in larger systems with cryogens. This paper will discuss the current status of the ZBOT experiment as it approaches its flight to installation on the International Space Station, how its findings can be scaled to larger and more ambitious cryogenic fluid management experiments, as well as ideas for follow-on investigations using ZBOT like hardware to study other aspects of cryogenic fluid management.

Fluid management↗

Evaluation of Electrical System Requirements for Implementing Turbine Electrified Energy Management

Turbine Electrified Energy Management (TEEM) is a concept concerned with the management of energy in an electrified propulsion system. The management of energy in the hybrid-electric architecture has potential to benefit the turbomachinery and the aircraft it powers. The concept is particularly useful for improving operability during transient operation and could be leveraged to design a better performing engine. The concept utilizes electric machines coupled to the engine shafts and an electric power distribution system that includes energy storage. A controller is used to decide when and how energy is moved around the electrified propulsion system, particularly when considering energy conversion between mechanical and electrical forms. Prior work has shown that the electric machines can be used to supply/or extract supplemental power to/from the engine shafts to improve their operability and achieve or enable propulsion efficiency and performance benefits. However, the previous studies did not consider the practical constraints of the electrical machines and energy storage devices that are required for implementing the TEEM system architecture concept. This paper presents an integrated engine and electrical system model that is used to evaluate the electrical system requirements. The model captures the physics of the conceptual, Advanced Geared Turbofan 30,000lbf (AGTF30) engine, which features advanced technologies such as a compact gas turbine and a variable area fan nozzle. For this work, the engine is augmented with electrical system components that allow for the implementation of the TEEM concept. The evaluation presented suggests the potential of the TEEM concept to provide performance benefits for a turbofan engine.

electrified↗

Evaluation of Electrical System Requirements for Implementing Turbine Electrified Energy Management

Turbine Electrified Energy Management (TEEM) is a concept concerned with the management of energy in an electrified propulsion system. The management of energy in the hybrid-electric architecture has potential to benefit the turbomachinery and the aircraft it powers. The concept is particularly useful for improving operability during transient operation and could be leveraged to design a better performing engine. The concept utilizes electric machines coupled to the engine shafts and an electric power distribution system that includes energy storage. A controller is used to decide when and how energy is moved around the electrified propulsion system, particularly when considering energy conversion between mechanical and electrical forms. Prior work has shown that the electric machines can be used to supply/or extract supplemental power to/from the engine shafts to improve their operability and achieve or enable propulsion efficiency and performance benefits. However, the previous studies did not consider the practical constraints of the electrical machines and energy storage devices that are required for implementing the TEEM system architecture concept. This paper presents an integrated engine and electrical system model that is used to evaluate the electrical system requirements. The model captures the physics of the conceptual, Advanced Geared Turbofan 30,000lbf (AGTF30) engine, which features advanced technologies such as a compact gas turbine and a variable area fan nozzle. For this work, the engine is augmented with electrical system components that allow for the implementation of the TEEM concept. The evaluation presented suggests the potential of the TEEM concept to provide performance benefits for a turbofan engine.

hybrid electric propulsion↗

Elastic-Plastic Thermal Stress Analysis of a High-Pressure Cryogenic Storage Tank

The thermal stresses on a cryogenic storage tank contribute strongly to the state of stress of the tank material and its ability to withstand operational stresses. These thermal stresses also affect the growth of any surface damage that might occur in the tank walls. These stresses are particularly of concern during the initial cooldown period for a new tank placed into service, and during any subsequent thermal cycles. A previous preliminary elastic analysis showed that the thermal stress on the inner wall would reach approximately 1,000MPa (145,000 psi). This stress far exceeds the ASTM specified room temperature values for both yield (170MPa) and ultimate (485 MPa) strength for 304L stainless steel. The present analysis determines the thermal stresses using an elastic-plastic model. The commercial software application ANSYS was used to determine the transient spatial temperature profile and the associated spatial thermal stress profiles in a segment of a thick-walled vessel during a typical cooldown process. A strictly elastic analysis using standard material properties for 304L stainless steel showed that the maximum thermal stress on the inner and outer walls was approximately 960 MPa (tensile) and - 270 MPa (compressive) respectively. These values occurred early in the cooldown process, but at different times, An elastic-plastic analysis showed significantly reducing stress, as expected due to the plastic deformation of the material. The maximum stress for the inner wall was approximately 225 MPa (tensile), while the maximum stress for the outer wall was approximately - 130 MPa (compressive).

Barker, J. Mark↗

Comparing the results of an analytical model of the no-vent fill process with no-vent fill test results for a 4.96 cu m (175 cu ft) tank

NASA-Lewis has been investigating a no-vent fill method for refilling cryogenic storage tanks in low gravity. Analytical modeling based on analyzing the heat transfer of a droplet has successfully represented the process in 0.034 and 0.142 sq m commercial dewars using liquid nitrogen and hydrogen. Recently a large tank (4.96 sq m) was tested with hydrogen. This lightweight tank is representative of spacecraft construction. This paper presents efforts to model the large tank test data. The droplet heat transfer model is found to overpredict the tank pressure level when compared to the large tank data. A new model based on equilibrium thermodynamics has been formulated. This new model is compared to the published large scale tank's test results as well as some additional test runs with the same equipment. The results are shown to match the test results within the measurement uncertainty of the test data except for the initial transient wall cooldown where it is conservative (i.e., overpredicts the initial pressure spike found in this time frame).

Taylor, William J.↗

Comparing the results of an analytical model of the no-vent fill process with no-vent fill test results for a 4.96 cubic meters (175 cubic feet) tank

The NASA Lewis Research Center (NASA/LeRC) have been investigating a no-vent fill method for refilling cryogenic storage tanks in low gravity. Analytical modeling based on analyzing the heat transfer of a droplet has successfully represented the process in 0.034 m and 0.142 cubic m commercial dewars using liquid nitrogen and hydrogen. Recently a large tank (4.96 cubic m) was tested with hydrogen. This lightweight tank is representative of spacecraft construction. This paper presents efforts to model the large tank test data. The droplet heat transfer model is found to over predict the tank pressure level when compared to the large tank data. A new model based on equilibrium thermodynamics has been formulated. This new model is compared to the published large scale tank's test results as well as some additional test runs with the same equipment. The results are shown to match the test results within the measurement uncertainty of the test data except for the initial transient wall cooldown where it is conservative (i.e., overpredicts the initial pressure spike found in this time frame).

Taylor, William J.↗

Waveform Based Acoustic Emission Detection and Location of Matrix Cracking in Composites

The operation of damage mechanisms in a material or structure under load produces transient acoustic waves. These acoustic waves are known as acoustic emission (AE). In composites they can be caused by a variety of sources including matrix cracking, fiber breakage, and delamination. AE signals can be detected and analyzed to determine the location of the acoustic source by triangulation. Attempts are also made to analyze the signals to determine the type and severity of the damage mechanism. AE monitoring has been widely used for both laboratory studies of materials, and for testing the integrity of structures in the field. In this work, an advanced, waveform based AE system was used in a study of transverse matrix cracking in cross-ply graphite/epoxy laminates. This AE system featured broad band, high fidelity sensors, and high capture rate digital acquisition and storage of acoustic signals. In addition, analysis techniques based on plate wave propagation models were employed. These features provided superior source location and noise rejection capabilities.

Prosser, W. H.↗

Autogenous Pressurization of a Cryogenic Tank Using Computational Fluid Dynamics

Well-validated simulation tools can be used to predict long-term storage and transfer of cryogenic propellants, which are essential to NASA’s mission plan to return to the Moon and continue to Mars. Autogenous pressurization of propellant tanks is used to supply rocket engine turbopumps with pressurized liquid fuel and oxidizer, preventing cavitation. Additionally, autogenous pressurization can be used to pressurize propellant tanks to support on-orbit propellant transfer. In lieu of expensive tests conducted on-orbit, accurate predictive computational models of these processes can be used to reduce system and propellant mass as well as mission risk. Using simulation tools also reduces the cost of analyzing and developing this technology. This study presents a multiphase computational fluid dynamics model capable of simulating autogenous pressurization of a large cryogenic tank using the commercial code STAR-CCM+. Experimental data from a full-scale tank pressurization test under terrestrial gravity is compared to simulation results using transient error metrics. Comparisons show good agreement and give confidence in using these and other validated simulation tools to develop cryogenic pressurization systems.

Cryogenics↗

Autogenous Pressurization of a Cryogenic Tank using Computational Fluid Dynamics

Well-validated simulation tools can be used to predict long-term storage and transfer of cryogenic propellants, which are essential to NASA’s mission plan to return to the Moon and continue to Mars. Autogenous pressurization of propellant tanks is used to supply rocket engine turbopumps with pressurized liquid fuel and oxidizer, preventing cavitation. Additionally, autogenous pressurization can be used to pressurize propellant tanks to support on-orbit propellant transfer. In lieu of expensive tests conducted on-orbit, accurate predictive computational models of these processes can be used to reduce system and propellant mass as well as mission risk. Using simulation tools also reduces the cost of analyzing and developing this technology. This study presents a multiphase computational fluid dynamics model capable of simulating autogenous pressurization of a large cryogenic tank using the commercial code STAR-CCM+. Experimental data from a full-scale tank pressurization test under terrestrial gravity is compared to simulation results using transient error metrics. Comparisons show good agreement and give confidence in using these and other validated simulation tools to develop cryogenic pressurization systems. Note: There is no audio file included or available for this presentation.

cryogenics↗