Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transient faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Modeling Co2 Flow Through Faulted/Fractured Reservoirs Using Tedfm in Corner-Point Grids

Interest in underground CO2 storage has increased significantly over the last decade, driven by growing concern about global warming and rising levels of greenhouse gases in the atmosphere. Given that CO2 accounts for 80% of these greenhouse gases, carbon capture, utilization, and storage (CCUS) is considered one of the most direct approaches to achieving the net-zero carbon target. Although CO2 storage in deep saline aquifers and depleted gas reservoirs has been studied extensively, most studies use commercial simulators that model faults/fractures by simply modifying the transmissibility in the direction perpendicular to the fault surfaces. This work shows that this simplistic approach ignores the accelerated flow in the directions parallel to the fault plane, leading to significantly higher leakage along the fault surface. To accurately model CO2 flow in faulted reservoirs, we present the first transient embedded discrete-fracture model for corner-point grids (tEDFM-CPG). By comparing the tEDFM-CPG results with high-resolution reference solutions, we show that this approach is accurate and efficient at predicting CO2 flow in faulted/fractured reservoirs. In conclusion, this work presents the use of mixed reality (MR) to efficiently observe CO2 gas migration in the interior of these corner-point grid systems.

02 PETROLEUM↗

Blackstart and Fault Ride-Through Capability of DFIG-Based Wind Turbines

Grid-forming wind turbines must be able to re-energize transmission branches, motor loads, unbalanced loads, and power electronics loads following a blackout. Further, they must ride through faults that can arise during restoration. To tackle these challenges, this paper sets forth a grid-forming control strategy for wind turbines using doubly-fed induction generators (DFIGs). In particular, a special set of feedforward control loops are engineered to mitigate the impacts of restoration transients as well as symmetrical and asymmetrical faults on the regulation of DFIG rotor currents and stator voltages. This paper also leverages two-axis anti-windup regulators to bound two-axis voltage and current commands within ratings. As a result, the controller performance is demonstrated via a high-fidelity simulation model of a notional wind-dominant grid.

17 WIND ENERGY↗

Evaluation of a Reduced-Order Model for IBR Fault Response Representation via OEM Blackbox Models: Preprint

Driven by the need to capture the electromagnetic transients of transmission lines, inverter switching behavior, and detailed control systems, electromagnetic transient (EMT) studies have become increasingly important in industry, such as IBR interconnection study and fault study. However, original equipment manufacturer (OEM) inverter models typically include extensive parameters and proprietary settings that are unavailable to protection engineers. This paper introduces a data-driven, reduced-order model (ROM) developed as a PSCAD library component for use in EMT-based fault studies. The ROM replicates key OEM model behaviors without requiring detailed knowledge of control design or parameterization. The accompanying Python automation scripts streamline data generation, parameter fitting, and validation. The ROM's performance is demonstrated through comparison with both IEEE 2800-compliant and non-compliant OEM models in a real-world power system. Relay responses show nearly identical results, while simulation runtime is reduced by an average of 32.8\%, highlighting the ROM's practicality for protection engineers.

14 SOLAR ENERGY↗

Behavior of Single-Line-Ground Faults in Inverter-Based Resource Dominated Grids Explained

It has been observed by protection engineers that it is difficult for a protective relay to identify the faulted phase during a single-line-ground (SLG) fault in a power system with a high ingression of inverter-based resources (IBR) using currents (phase or sequence). Further studies using electromagnetic transient (EMT) simulation show that the initial operating conditions of the IBRs influence the response of phase currents during an SLG fault. In this letter, we conduct a quantitative analysis using sequence components. We find that the pre-fault condition determines the relative position of the current contributed by the grid versus that from the IBR, and further dictates which phase has the largest magnitude during an SLG condition. Finally, this finding is further verified by the EMT simulation results.

electromagnetic transient simulation↗

Precursory Locking Precedes Slip Events on Laboratory Fault

Earthquakes occur through repeated cycles of locking and slip. What is the relationship between transiently locked patches and the size, location, and timing of the subsequent slip events? Here we use an experimental fault made of transparent rubber to image the slip history of over 18,000 events. The soft elastic system allows for contained ruptures and thus a natural evolution of stress heterogeneity over multiple earthquake cycles. We observe a precursory locking phase preceding slip nucleation for events of all sizes. The integrated locking distance increases linearly with the moment of the eventual event. The most intense (largest slip deficit) locking events are spatially and temporally correlated with the hypocenters of the largest rupture events. These results show that the transient locking is statistically, but not deterministically, predictive of the location, timing, and size of the eventual slip event.

earthquakes↗

Effect of Accurate Modeling of Converter Interfaced Generation (CIG) on a Practical Bulk Power System

With increased penetration of converter interfaced generation (CIG) in power systems, it becomes imperative to adequately model them in both steady-state and dynamic simulations. There are several modeling approaches and simulation platforms for CIG. In addition, it is noted that suitability of modeling approaches and models is also dependent on the system conditions. However, their suitability has yet to be systematically analyzed, and this becomes a challenge in the industry without a systemic method. To tackle these challenges, in this paper, we first develop a methodology for identifying the maximum penetration of aggregated rooftop sources that can be represented as negative loads in both the steady state and dynamic analysis. Then we verify the suitability of positive-sequence performance-based model and detailed electromagnetic transient (EMT) model for utility-scale PV plants under different fault conditions. Based on the results, we perform dynamic simulations on a large practical system with both positive-sequence transient stability(TS) and EMT-TS hybrid simulation. Our study shows that positive-sequence performance based PV plant model is more suitable for study cases with faults relatively far away from the point of connection, and that positive-sequence models and TS simulation approach can produce comparable results with reference to EMT-TS hybrid simulation for normally-cleared single-line-to-ground faults, but the inadequacy of positive-sequence based model and simulation approach becomes obvious for prolonged-tripping of unbalanced faults in proximity of the PV plants.

Huang, Qiuhua↗

Improved Transient Stability Analysis of Multi-loop Droop-Controlled Grid Forming Inverters with Current Reference Limiter

Grid-forming control is regarded as a promising technology for achieving high levels of renewable energy integration in future power grids. To fulfill this role, grid-forming devices is expected to possess fault ride through capability. This paper focuses on the transient stability of a droop control-based grid-forming inverter that utilizes current reference saturation as a current limiting strategy. The objective of this work is to investigate the fault recovery process of the grid-forming inverter and analyze the criterion for transitioning the inverter out of the current limiting mode. The theoretical analysis in this study is validated through time-domain simulations, which compare the results obtained using the circuit current limiting method and the d-axis priority-based current limiting method. Various operational conditions are considered to comprehensively evaluate the performance of the grid-forming inverter during a three-phase short circuit scenario. The simulation results confirm the effectiveness of the proposed theoretical approach.

Lyu, Xue↗

Control Design and EMT Simulation Toward the Restoration of Faulted Wind-Dominant Grids

Present power engineers have been challenged to employ electromagnetic transient (EMT) simulations to study the restoration of wind-dominant grids. This paper addresses this hurdle by developing strategies to: (i) reliably control the dc-link voltage of grid-forming wind turbines with dc-coupled batteries, (ii) tune controllers to stably interconnect wind power plants into a grid under recovery, and (iii) autonomously make restoration decisions if transmission faults occur during restoration. These contributions are assessed via EMT simulations of wind-dominant versions of the WSCC 9-bus grid and a 22-bus power system. Furthermore, this paper is significant to address recommendations by the North American Electric Reliability Corporation.

17 WIND ENERGY↗

Deep learning model for fast, science-based forecasting of fluid migration along faults in geologic carbon storage scenarios

Effective long-term geologic storage depends on robust site selection and credible, science-based forecasting of subsurface behavior to ensure storage integrity. For this work, we develop a deep learning–based reduced-order model (ROM) to quantify potential carbon dioxide (CO₂) and brine migration through geological faults. The ROM combines a Transformer model for binary classification and a Stacked Ensemble for regression, trained on a comprehensive dataset generated from 1400 physics-based reservoir simulations. Key geologic and operational parameters—including fault geometry, reservoir structure, and injection conditions—were systematically varied to capture a wide range of fluid migration scenarios. The ROM accurately predicts the onset of migration, cumulative migration volumes of both CO₂ and brine, and associated migration rates, as compared to an independent set of validation simulations, while significantly reducing computational cost compared to traditional simulation methods. Model performance was evaluated across diverse fault configurations, revealing that shallow reservoir geometry and fault angle are among the most influential factors governing migration behavior. Sensitivity analysis using SHapley Additive exPlanations (SHAP) provided interpretability, revealing distinct patterns in how geological and operational features drive transient versus cumulative migration outcomes. The ROM’s ability to rapidly simulate fault migration scenarios enables efficient sensitivity analyses, scenario evaluations, and decision support for site selection and monitoring design. This approach enhances the safety, scalability, and long-term operational performance of geologic carbon storage (GCS) systems by providing a robust, interpretable tool for predicting subsurface fluid migration and assessing fault-related migration potential.

42 ENGINEERING↗

Criteria for Grid-Forming Inverters Transitioning Between Current Limiting Mode and Normal Operation

Here, this letter focuses on the fault recovery analysis of inverters using multi-loop droop based grid-forming control, taking into account different current limiting strategies. A criterion is proposed to determine when the inverter can exit the current limiting mode after fault clearance. The theoretical findings are verified through electromagnetic transient simulations using the direct (d)-axis priority-based current limiting method, circular current limiting method, and virtual impedance method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Effect of Normal Stress Oscillations on Fault Slip Behavior Near the Stability Transition From Stable to Unstable Motion

Tectonic fault zones are subject to normal stress variations with a wide range of spatio-temporal scales. Stress perturbations cover a wide range of frequencies and amplitudes from high frequency seismic waves generated by earthquakes to low frequency transients associated with solid Earth tides. These perturbations can reactivate critically stressed faults and trigger earthquakes. Here, we describe lab experiments to illuminate the physics of such changes in friction and the mechanics of earthquake triggering and fault reactivation. Friction tests were done in a double direct shear configuration for conditions near the stability transition from stable to unstable motion. We studied simulated fault gouge composed of quartz powder and conducted experiments at reference normal stress from 10 to 13.5 MPa. After shearing to steady state sliding, we applied sinusoidal normal stress oscillations of amplitude 0.5–2 MPa, and period of 0.5–50 s. We performed numerical simulations using measured values of rate and state friction (RSF) parameters to assess our data. Our results show that low frequency stress oscillations cause a Coulomb-like response of shear strength that transitions from stable slip to slow lab earthquakes as frequency increases. At the critical frequency predicted by RSF we observe periodic stick-slip behavior. Perturbations of high amplitude and short period weaken the fault, while lower amplitudes strengthen the fault. We find that a modified RSF formulation is able to accurately match our laboratory data. Our findings highlight the complex effects of stress perturbations on fault strength and the mode of fault slip.

58 GEOSCIENCES↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, ate- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

14 SOLAR ENERGY↗

A Generic and Multi-Functional Electromagnetic Transient Model for Grid-Following Inverter: Preprint

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD TM software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, aB- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

grid following inverter↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids

Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids

Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Feedback Control Strategy for Transient Stability Application

Power systems are subjected to a wide range of disturbances during daily operations. Severe disturbances, such as a loss of a large generator, a three-phase bolted fault on a generator bus, or a loss of a transmission line, can lead to the loss of synchronism of a generator or group of generators. The ability of a power system to maintain synchronism during the few seconds after being subjected to a severe disturbance is known as transient stability. Most of the modern methods of controlling transient stability involve special protection schemes or remedial action schemes. These special protection schemes sense predetermined system conditions and take corrective actions, such as generator tripping or generation re-dispatch, in real time to maintain transient stability. Another method is the use of a real-time feedback control system to modulate the output of an actuator in response to a signal. This paper provides a fundamental evaluation of the use of feedback control strategies to improve transient stability in a power system. An optimal feedback control strategy that modulates the real power injected and absorbed by distributed energy-storage devices is proposed. Its performance is evaluated on a four-machine power system and on a 34-machine reduced-order model of the Western North American Power System. The result shows that the feedback control strategy can increase the critical fault clearing time by 60%, thereby improving the transient stability of the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Per-phase Phasor Modeling of GFL and GFM Inverters for Distribution System Dynamic Studies

A significant increase in inverter-based distributed energy resources (DERs) is expected in the near future. Existing electromagnetic models and sequential electromechanical models of DERs supporting dynamic analysis cannot be extended to largescale three-phase distribution systems usually with unbalanced construction. As such, there is a need for appropriate industry models that can support distribution system dynamic studies. This paper describes the latest phasor models of grid-following (GFL) and grid-forming (GFM) inverters that can capture distribution system dynamics under grid disturbances. The overall modeling performance is examined and compared with results from other platforms such as controller hardware-in-the-loop (CHIL), MATLAB/Simulink and PSCAD with electromagnetic transient (EMT) and/or phasor simulation capabilities under balanced and unbalanced faults.

Distribution system, Grid modelling, GridLAB-D, Po↗