Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “trace gas concentration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Evaluating the SAGE III/ISS Version 5.2 Water Vapor Retrieval in the Presence of Aerosol Loading

The Stratospheric Aerosol and Gas Experiment operating on the International Space Station (SAGE III/ISS) is an occultation instrument that retrieves aerosol extinction and ozone, water vapor, and other trace gas concentrations. Water vapor in the stratosphere plays a role in ozone depletion and global temperature regulation making it an important species to monitor. The SAGE III/ISS instrument provides high quality, vertically resolved profiles of water vapor throughout the stratosphere and upper troposphere. In previous versions of SAGE water vapor products, a dry bias was noted in comparison to other satellite retrievals in the presence of elevated aerosol optical depth. Several updates for the version 5.2 water vapor algorithm will be presented and compared with previous versions of the data and other satellite products during different periods of aerosol loading.

M Heitz↗

Versatile soil gas concentration and isotope monitoring: optimization and integration of novel soil gas probes with online trace gas detection

Abstract. Gas concentrations and isotopic signatures can unveil microbial metabolisms and their responses to environmental changes in soil. Currently, few methods measure in situ soil trace gases such as the products of nitrogen and carbon cycling or volatile organic compounds (VOCs) that constrain microbial biochemical processes like nitrification, methanogenesis, respiration, and microbial communication. Versatile trace gas sampling systems that integrate soil probes with sensitive trace gas analyzers could fill this gap with in situ soil gas measurements that resolve spatial (centimeters) and temporal (minutes) patterns. We developed a system that integrates new porous and hydrophobic sintered polytetrafluoroethylene (sPTFE) diffusive soil gas probes that non-disruptively collect soil gas samples with a transfer system to direct gas from multiple probes to one or more central gas analyzer(s) such as laser and mass spectrometers. Here, we demonstrate the feasibility and versatility of this automated multiprobe system for soil gas measurements of isotopic ratios of nitrous oxide (δ18O, δ15N, and the 15N site preference of N2O), methane, carbon dioxide (δ13C), and VOCs. First, we used an inert silica matrix to challenge probe measurements under controlled gas conditions. By changing and controlling system flow parameters, including the probe flow rate, we optimized recovery of representative soil gas samples while reducing sampling artifacts on subsurface concentrations. Second, we used this system to provide a real-time window into the impact of environmental manipulation of irrigation and soil redox conditions on in situ N2O and VOC concentrations. Moreover, to reveal the dynamics in the stable isotope ratios of N2O (i.e., 14N14N16O, 14N15N16O, 15N14N16O, and 14N14N18O), we developed a new high-precision laser spectrometer with a reduced sample volume demand. Our integrated system – a tunable infrared laser direct absorption spectrometry (TILDAS) in parallel with Vocus proton transfer reaction mass spectrometry (PTR-MS), in line with sPTFE soil gas probes – successfully quantified isotopic signatures for N2O, CO2, and VOCs in real time as responses to changes in the dry–wetting cycle and redox conditions. Broadening the collection of trace gases that can be monitored in the subsurface is critical for monitoring biogeochemical cycles, ecosystem health, and management practices at scales relevant to the soil system.

54 ENVIRONMENTAL SCIENCES↗

Carbon Cycle Gas Flask Sampler at SGP

As part of the In-Situ Aerosol Profiles (IAP) campaign, non-aerosol instruments which have been incorporated into the aerosol package include a programmable flask package for obtaining samples of carbon dioxide and other trace gases at each flight level.

54 ENVIRONMENTAL SCIENCES↗

Low-background trace-gas detector

Spectrophone detects very small concentrations of trace gases. With gas in sample cell, laser is tuned to absorption line of interest. Molecular absorption in cell produces pulsed acoustical pressure at chopper frequency. Two optical paths with very different absorption lengths are used to pretune cell to balance out background absorption by cell windows.

Rosengren, L.↗

The Arctic Boundary Layer Expedition (ABLE-3B): July - August 1990

The Arctic Boundary Layer Expedition (ABLE) 3B used data from ground-based, aircraft, and satellite platforms to characterize the chemistry and dynamics of the troposphere in subarctic and Arctic regions of midcontinent and eastern Canada during July - August 1990. This paper reports the experimental design for ABLE 3B and a brief overview of results. The detailed results are presented in a series of papers in this issue. The chemical composition of the atmospheric mixed layer over remote tundra, boreal wetland, and forested environments was influenced by emissions of CH4 and nonmethane hydrocarbons from biogenic sources, emissions of gases and aerosols from local biomass burning, and transport of pollutants into the study areas from urban/industrial sources. Minimum concentrations of both trace gas and aerosol species in boundary layer air were associated with Arctic source areas. In the free troposphere the biospheric influence was undetectable, and major sources of chemical variability were related to long-range transport of pollutants into the study areas from biomass burning and industrial sources in Alaska and the Great Lakes regions, respectively. Minimum concentrations of both trace gas and aerosol species in the free troposphere were associated with a persistent, widespread air mass which both chemistry and air mass trajectory analyses suggested had originated in the tropical Pacific. Subsidence of air from the upper troposphere and lower stratosphere frequently enhanced ozone and influenced other trace gas and aerosol species at midtropospheric altitudes. The North American Arctic is a complex dynamical and chemical environment with considerable spatial and temporal variability in aerosol and trace gas concentrations. The use of atmospheric chemical indicators for climate change detection will require a much more comprehensive Arctic monitoring program than currently exists.

Harriss, R. C.↗

Miniature Tunable Laser Spectrometer for Detection of a Trace Gas

An open-path laser spectrometer (OPLS) for measuring a concentration of a trace gas, the OPLS including an open-path multi-pass analysis region including a first mirror, a second mirror at a distance and orientation from the first mirror, and a support structure for locating the mirrors, a laser coupled to the analysis region and configured to emit light of a wavelength range and to enable a plurality of reflections of the emitted light between the mirrors, a detector coupled to the analysis region and configured to detect a portion of the emitted light impinging on the detector and to generate a corresponding signal, and an electronic system coupled to the laser and the detector, and configured to adjust the wavelength range of the emitted light from the laser based on the generated signal, and to measure the concentration of the trace gas based on the generated signal.

Christensen, Lance E.↗

Soil gas probes for monitoring trace gas messengers of microbial activity

Abstract Soil microbes vigorously produce and consume gases that reflect active soil biogeochemical processes. Soil gas measurements are therefore a powerful tool to monitor microbial activity. Yet, the majority of soil gases lack non-disruptive subsurface measurement methods at spatiotemporal scales relevant to microbial processes and soil structure. To address this need, we developed a soil gas sampling system that uses novel diffusive soil probes and sample transfer approaches for high-resolution sampling from discrete subsurface regions. Probe sampling requires transferring soil gas samples to above-ground gas analyzers where concentrations and isotopologues are measured. Obtaining representative soil gas samples has historically required balancing disruption to soil gas composition with measurement frequency and analyzer volume demand. These considerations have limited attempts to quantify trace gas spatial concentration gradients and heterogeneity at scales relevant to the soil microbiome. Here, we describe our new flexible diffusive probe sampling system integrated with a modified, reduced volume trace gas analyzer and demonstrate its application for subsurface monitoring of biogeochemical cycling of nitrous oxide (N 2 O) and its site-specific isotopologues, methane, carbon dioxide, and nitric oxide in controlled soil columns. The sampling system observed reproducible responses of soil gas concentrations to manipulations of soil nutrients and redox state, providing a new window into the microbial response to these key environmental forcings. Using site-specific N 2 O isotopologues as indicators of microbial processes, we constrain the dynamics of in situ microbial activity. Unlocking trace gas messengers of microbial activity will complement -omics approaches, challenge subsurface models, and improve understanding of soil heterogeneity to disentangle interactive processes in the subsurface biome.

04 OIL SHALES AND TAR SANDS↗

EPCAPE-PT-LANL Measurements: PM Modulair 1

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Quant-AQ MODULAIR. Mounted external to the instrument container, near the GCVI inlet. The MODULAIR™ air quality monitor uses the same patent-pending PM sensor found in the MODULAIR™-PM and adds four gas-phase measurements (CO, NO, NO2, and O3) to provide an all-in-one solution. Files data_10sec_Quant_Gas.csv, data_10min_Quant_Gas.csv Header: - CO[ppb]: Concentration of carbon monoxide (CO) measured at the time of sampling, expressed in parts per billion (ppb) - NO[ppb]: Concentration of nitric oxide (NO) measured at the time of sampling, expressed in parts per billion (ppb). - O3[ppb]: Concentration of ozone (O3) measured at the time of sampling, expressed in parts per billion (ppb). - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage. Files data_10sec_Quant_PM.csv, data_10min_Quant_PM.csv Header: - PM1[ug/m3]: Concentration of particulate matter with a diameter of 1 micron or less, measured in micrograms per cubic meter (µg/m³). - PM2-5[ug/m3]: Concentration of particulate matter with a diameter of 2.5 microns or less measured in micrograms per cubic meter (µg/m³). - PM10[ug/m3]: Concentration of particulate matter with a diameter of 10 microns or less, measured in micrograms per cubic meter (µg/m³). - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage.

54 ENVIRONMENTAL SCIENCES↗

The Net Decay Time of Anomalies in Concentrations of Atmospheric Pollutants

This paper introduces a new parameter to characterize the random component in temporal variability of atmospheric pollutants and proposes a simple statistical technique for its evaluation. That parameter is the net decay time (or the time scale) of the local anomalies in concentrations of atmospheric pollutants, rather than the traditionally used chemical lifetimes of total amounts of the species. Using widely available data of hourly multi-year surface trace gas pollutant concentrations we demonstrate a simplified way to estimate the net decay time with an exponential approximation of lag-correlation functions. We assessed the decay times of fluctuations in observations of eight atmospheric pollutants (SO2, NO, NO2, NOy, O3, CO, NH3, and HNO3) at two urban sites and one cleaner rural site in the Eastern US. The time scales of temporal fluctuations (net decay times) vary from about one hour to slightly more than one day. These scales are generally much shorter in urban environments than in remote regions. We also compared day- and night-time observations in warm and cold seasons. At night in the cold season, time scales of fluctuations in atmospheric pollutants are usually the longest. Such estimates should be useful to air quality prediction, public health, and satellite remote sensing research communities.

air quality prediction↗

Time‐Series Analysis: A Cautionary Tale

Time-series analysis has often been a useful tool in atmospheric science for deriving long-term trends in various atmospherically important parameters (e.g., temperature or the concentration of trace gas species). In particular, time-series analysis has been repeatedly applied to satellite datasets in order to derive the long-term trends in stratospheric ozone, which is a critical atmospheric constituent. However, many of the potential pitfalls relating to the non-uniform sampling of the datasets were often ignored and the results presented by the scientific community have been unknowingly biased. A newly developed and more robust application of this technique is applied to the Stratospheric Aerosol and Gas Experiment (SAGE) II version 7.0 ozone dataset and the previous biases and newly derived trends are presented.

Damadeo, Robert↗

A Miniaturized Laser Heterodyne Radiometer for a Global Ground-Based Column Carbon Monitoring Network

We present progress in the development of a passive, miniaturized Laser Heterodyne Radiometer (mini-LHR) that will measure key greenhouse gases (C02, CH4, CO) in the atmospheric column as well as their respective altitude profiles, and O2 for a measure of atmospheric pressure. Laser heterodyne radiometry is a spectroscopic method that borrows from radio receiver technology. In this technique, a weak incoming signal containing information of interest is mixed with a stronger signal (local oscillator) at a nearby frequency. In this case, the weak signal is sunlight that has undergone absorption by a trace gas of interest and the local oscillator is a distributive feedback (DFB) laser that is tuned to a wavelength near the absorption feature of the trace gas. Mixing the sunlight with the laser light, in a fast photoreceiver, results in a beat signal in the RF. The amplitude of the beat signal tracks the concentration of the trace gas in the atmospheric column. The mini-LHR operates in tandem with AERONET, a global network of more than 450 aerosol sensing instruments. This partnership simplifies the instrument design and provides an established global network into which the mini-LHR can rapidly expand. This network offers coverage in key arctic regions (not covered by OCO-2) where accelerated warming due to the release of CO2 and CH4 from thawing tundra and permafrost is a concern as well as an uninterrupted data record that will both bridge gaps in data sets and offer validation for key flight missions such as OCO-2, OCO-3, and ASCENDS. Currently, the only ground global network that routinely measures multiple greenhouse gases in the atmospheric column is TCCON (Total Column Carbon Observing Network) with 18 operational sites worldwide and two in the US. Cost and size of TCCON installations will limit the potential for expansion, We offer a low-cost $30Klunit) solution to supplement these measurements with the added benefit of an established aerosol optical depth measurement. Aerosols induce a radiative effect that is an important modulator of regional carbon cycles. Changes in the diffuse radiative flux fraction (DRF) due to aerosol loading have the potential to alter the terrestrial carbon exchange.

Wilson, Emily L.↗

Automated identification of local contamination in remote atmospheric composition time series

Abstract. Atmospheric observations in remote locations offer a possibility of exploring trace gas and particle concentrations in pristine environments. However, data from remote areas are often contaminated by pollution from local sources. Detecting this contamination is thus a central and frequently encountered issue. Consequently, many different methods exist today to identify local contamination in atmospheric composition measurement time series, but no single method has been widely accepted. In this study, we present a new method to identify primary pollution in remote atmospheric datasets, e.g., from ship campaigns or stations with a low background signal compared to the contaminated signal. The pollution detection algorithm (PDA) identifies and flags periods of polluted data in five steps. The first and most important step identifies polluted periods based on the derivative (time derivative) of a concentration over time. If this derivative exceeds a given threshold, data are flagged as polluted. Further pollution identification steps are a simple concentration threshold filter, a neighboring points filter (optional), a median, and a sparse data filter (optional). The PDA only relies on the target dataset itself and is independent of ancillary datasets such as meteorological variables. All parameters of each step are adjustable so that the PDA can be “tuned” to be more or less stringent (e.g., flag more or fewer data points as contaminated). The PDA was developed and tested with a particle number concentration dataset collected during the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition in the central Arctic. Using strict settings, we identified 62 % of the data as influenced by local contamination. Using a second independent particle number concentration dataset also collected during MOSAiC, we evaluated the performance of the PDA against the same dataset cleaned by visual inspection. The two methods agreed in 94 % of the cases. Additionally, the PDA was successfully applied to a trace gas dataset (CO2), also collected during MOSAiC, and to another particle number concentration dataset, collected at the high-altitude background station Jungfraujoch, Switzerland. Thus, the PDA proves to be a useful and flexible tool to identify periods affected by local contamination in atmospheric composition datasets without the need for ancillary measurements. It is best applied to data representing primary pollution. The user-friendly and open-access code enables reproducible application to a wide suite of different datasets. It is available at https://doi.org/10.5281/zenodo.5761101 (Beck et al., 2021).

54 ENVIRONMENTAL SCIENCES↗

Analysis of atmospheric spectra for trace gases

The objective is the comprehensive analysis of high resolution atmospheric spectra recorded in the middle-infrared region to obtain simultaneous measurements of coupled parameters (gas concentrations of key trace constituents, total column amounts, pressure, and temperature) in the stratosphere and upper troposphere. Solar absorption spectra recorded at 0.002 and 0.02 cm exp -1 resolutions with the University of Denver group's balloon-borne, aircraft borne, and ground-based interferometers and 0.005 to 0.01 cm exp -1 resolution solar spectra from Kitt Peak are used in the analyses.

Rinsland, Curtis P.↗

Laser Heterodyne Radiometer for Sensitive Detection of CO2 and CH4

We propose to develop an inexpensive, miniaturized, passive laser heterodyne radiometer (LHR) using commercially available telecommunications laser components to measure two significant carbon cycle gases in the atmospheric column: carbon dioxide (CO2) and methane (CH4). This instrument would operate in tandem with the passive aerosol sensor currently used in AERONET (an established network of more than 450 ground aerosol monitoring instruments worldwide). Because aerosols induce a radiative effect that influences terrestrial carbon exchange, simultaneous detection of aerosols with these key carbon cycle gases offers a uniquely comprehensive measurement approach that supports the Decadal Survey. Laser heterodyne radiometry is a technique for detecting weak signals that was adapted from radio receiver technology. In a radio receiver, a weak input signal from a radio antenna is mixed with a stronger local oscillator signal. The mixed signal (beat note, or intermediate frequency) has a frequency equal to the difference between the input signal and the local oscillator. The intermediate frequency is amplified and sent to a detector that extracts the audio from the signal. In a laser heterodyne radiometer, the weak input signal is light that has undergone absorption by a trace gas. The local oscillator is a laser at a near-by frequency - in this case a low-cost distributed feedback (DFB) telecommunications laser. These two light waves are superimposed in either a beamsplitter or in a fiber coupler (as is the case in this design). The signals are mixed in the detector, and the RF beat frequency is extracted. Changes in concentration of the trace gas are realized through analyzing changes in the beat frequency amplitude. A schematic of the progression of the LHR development project is shown in the figure below. At the center (within the dashed line), light from the local oscillator is superimposed upon light that has undergone absorption by a trace gas, in a single mode fiber coupler. Superimposed light is mixed in a fast photoreceiver, and the beat signal is analyzed for changes in absorption. The left portion of the figure depicts a progression of light sources that pass through the trace gas, increasing in complexity in the downward direction. On the right side of the figure, RF signal processing progresses from a commercially available spectrum analyzer to a RF receiver, and finally to an RF filter bank to deconvolute portions of the beat frequency more heavily weighted for different altitudes.

Wilson, Emily L.↗

Nebulization reflux concentrator

A nebulization reflux concentrator for removing trace gas contaminants from a sample gas is described. Sample gas from a gas supply is drawn by a suction source into a vessel. The gas enters the vessel through an atomizing nozzle, thereby atomizing and entraining a scrubbing liquid solvent drawn through a siphon tube from a scrubbing liquid reservoir. The gas and entrained liquid rise through a concentrator and impinge upon a solvent phobic filter, whereby purified gas exits through the filter housing and contaminated liquid coalesces on the solvent phobic filter and falls into the reservoir.

Collins, V. G.↗

BOREAS TGB-5 Dissolved Organic Carbon Data from NSA Beaver Ponds

The BOReal Ecosystem-Atmosphere Study Trace Gas Biogeochemistry (BOREAS TGB-5) team collected several data sets related to carbon and trace gas fluxes and concentrations in the Northern Study Area (NSA). This data set contains concentrations of dissolved organic and inorganic carbon species from water samples collected at various NSA sites. In particular, this set covers the NSA Tower Beaver Pond Site and the NSA Gillam Road Beaver Pond Site, including data from all visits to open water sampling locations during the BOREAS field campaigns from April to September 1994. The data are provided in tabular ASCII files.

Bourbonniere, Rick↗

Long-range Transport of Siberian Biomass Burning Emissions to North America During FIREX-AQ

Biomass burning from wildfires is a significant global source of aerosol and trace gases which impact air quality, tropospheric and stratospheric composition, and climate. During the summer of 2019, wildfire activity in central and eastern Siberia occurred during the Fire Influence on Regional to Global Environments and Air Quality (FIREX-AQ) campaign conducted between July 24 and September 6, 2019. Ground-based lidar observations from the Autonomous Mobile Ozone Lidar for Tropospheric Experiments (AMOLITE) system in Alberta, Canada retrieved frequent anomalous ozone (O3) and aerosol lamina in the troposphere and lower stratosphere during this campaign. Data from NASA’s GEOS Composition Forecast (GEOS-CF) coupled chemistry meteorology model, TROPOspheric Monitoring Instrument (TROPOMI), Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO), and ground-based insitu data were used to define the trans-Pacific and trans-Arctic transport pathway of Siberian biomass burning emissions resulting in the enhanced O3 and aerosol lamina observed by AMOLITE in western Canada. Siberian wildfires impacted North American air quality resulting in enhancements of hourly-averaged surface carbon monoxide (CO) (total CO >150 ppb) and fine particulate matter (PM2.5) (>20 μg m-3) in western Canada, however, minimal increases in surface-level O3 were measured as well as modeled by GEOS-CF. The impact in western Canada due to Siberian wildfires was much larger in the free troposphere, demonstrated by GEOS-CF and AMOLITE O3 lamina 30–40 ppb above background values and model-predicted PM2.5 lamina >30 μg m-3. In addition to tropospheric composition effects, the large wildfire activity in Siberia may have influenced the stratosphere as data from AMOLITE, CALIPSO, and GEOS-CF all suggested aerosol layers from the fires were located 13–18 km above ground level (agl). This study shows that the Siberian biomass burning emissions in the summer of 2019 impacted tropospheric/stratospheric composition in western Canada, and potentially could have influenced areas in the vicinity of FIREX-AQ airborne measurements, and future studies of FIREX-AQ chemical composition should consider how this long-range transport could have influenced the background trace gas and aerosol concentrations being investigated.

Biomass↗

Enhanced Raman Monitor Project

Monitoring of gaseous contaminants stems from the need to ensure a healthy and safe environment. NASA/Ames needs sensors that are able to monitor common atmospheric gas concentrations as well as trace amounts of contaminant gases. To provide an accurate assessment of air quality, a monitoring system would need to be continuous and on-line with full spectrum capabilities, allowing simultaneous detection of all gas components in a sample, including both combustible and non-combustible gases. The system demands a high degree of sensitivity to detect low gas concentrations in the low-ppm and sub-ppm regions. For clean and healthy air ('good' category), criteria established by the EPA requires that contaminant concentrations not exceed 4 ppm of carbon monoxide (CO) in an 8 hour period, 60 ppb of ozone(O3) in a one hour period and 30 ppb of sulfur dioxide (SO2) in a 24 hour period. One step below this is the National Ambient Air Quality Standard ('moderate' category) which requires that contaminant concentrations not exceed 9 ppm of carbon monoxide (CO), 120 ppb of ozone (O3) and 140 ppb of sulfur dioxide (SO2) for their respective time periods. Ideally a monitor should be able to detect the concentrations specified in the 'good' category. To benchmark current abilities of Raman technology in gas phase analysis, laboratory experiments were performed to evaluate the RASCAL II anesthetic gas monitor.

Westenskow, Dwayne↗