67 records · Page 4

Long-term, non-invasive FTIR detection of low-dose ionizing radiation exposure

Non-invasive methods of detecting radiation exposure show promise to improve upon current approaches to biological dosimetry in ease, speed, and accuracy. Here we developed a pipeline that employs Fourier transform infrared (FTIR) spectroscopy in the mid-infrared spectrum to identify a signature of low dose ionizing radiation exposure in mouse ear pinnae over time. Mice exposed to 0.1 to 2 Gy total body irradiation were repeatedly measured by FTIR at the stratum corneum of the ear pinnae. We found significant discriminative power for all doses and time-points out to 90 days after exposure. Classification accuracy was maximized when testing 14 days after exposure (specificity > 0.9 with a sensitivity threshold of 0.9) and dropped by roughly 30% sensitivity at 90 days. Infrared frequencies point towards biological changes in DNA conformation, lipid oxidation and accumulation and shifts in protein secondary structure. Since only hundreds of samples were used to learn the highly discriminative signature, developing human-relevant diagnostic capabilities is likely feasible and this non-invasive procedure points toward rapid, non-invasive, and reagent-free biodosimetry applications at population scales.

61 RADIATION PROTECTION AND DOSIMETRY↗

Methods and compositions for protection of cells and tissues from computed tomography radiation

Described are methods for preventing or inhibiting genomic instability and in cells affected by diagnostic radiology procedures employing ionizing radiation. Embodiments include methods of preventing or inhibiting genomic instability and in cells affected by computed tomography (CT) radiation. Subjects receiving ionizing radiation may be those persons suspected of having cancer, or cancer patients having received or currently receiving cancer therapy, and or those patients having received previous ionizing radiation, including those who are approaching or have exceeded the recommended total radiation dose for a person.

Grdina, David J.↗

Updates to Composite Analysis Base Case and Null Space Monte Carlo Sensitivity Based on New Unit Dose Factors

This environmental calculation file (ECF) presents the results of the exposure route-specific and total radiological dose assessments for the groundwater exposure pathway as a part of the updated Composite Analysis for Low-Level Waste Disposal in the Hanford Site Central Plateau (FY 2022), based on revised unit dose factors (UDFs) published in CA Special Studies: Updates to the Groundwater Pathway Radiological Dose. The reason for these radiological dose assessments is to estimate the cumulative radiological impacts from all screened sources of ionizing radiation and exposure routes that could potentially contribute to the projected dose to a hypothetical member of the public. Sources of ionizing radiation can include existing or future disposal facilities and other sources including past-practice discharge sites. Additionally, the results of the exposure route-specific and total radiological dose assessments have been revised for the groundwater pathway based on the null space Monte Carlo (NSMC) groundwater concentrations and the most recent updates to the UDFs as a part an uncertainty analysis for the updated Hanford Site CA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Acute total body ionizing gamma radiation induces long-term adverse effects and immediate changes in cardiac protein oxidative carbonylation in the rat

Radiation-induced heart disease presents a significant challenge in the event of an accidental radiation exposure as well as to cancer patients who receive acute doses of irradiation as part of radiation therapy. We utilized the spontaneously hypertensive Wistar-Kyoto rat model, previously shown to demonstrate drug-induced cardiomyopathy, to evaluate the acute and long-term effects of sub-lethal total body gamma irradiation at two, four, and fiftytwo weeks. We further examined irreversible oxidative protein carbonylation in the heart immediately following irradiation in the normotensive Wistar-Kyoto rat. Both males and females sustained weight loss and anemic conditions compared to untreated controls over a one-year period as reflected by reduced body weight and low red blood cell count. Increased inflammation was detected by elevated IL-6 serum levels selectively in males at four weeks. Serum cardiac troponin T and I analyses revealed signs of cardiomyopathy at earlier timepoints, but high variability was observed, especially at one year. Echocardiography at two weeks following 5.0Gy treatment revealed a significant decrease in cardiac output in females and a significant decrease in both diastolic and systolic volumes in males. Following 10.0Gy irradiation in the normotensive Wistar-Kyoto rat, the heart tissue showed an increase in total protein oxidative carbonylation accompanied by DNA damage indicated by an increase in γ-H2AX. Using proteomic analyses, we identified several novel proteins which showed a marked difference in carbonylation including those of mitochondrial origin and most notably, cardiac troponin T, one of the key proteins involved in cardiomyocyte contractility. Overall, we present findings of acute oxidative protein damage, DNA damage, cardiac troponin T carbonylation, and long-term cardiomyopathy in the irradiated animals.

59 BASIC BIOLOGICAL SCIENCES↗

Calculation of Groundwater Pathway Radiological Dose for the Hanford Site Composite Analysis Base Case

The purpose of this environmental calculation file (ECF) is to present the results of the exposure route-specific and total radiological dose assessments for the groundwater exposure pathway as a part of the updated Hanford Site Composite Analysis (CA). The purpose of these radiological dose assessments is to provide an estimate of the cumulative radiological impacts from all screened sources of ionizing radiation and exposure routes that could potentially contribute to the projected dose to a hypothetical member of the public from both existing or future disposal facilities and other sources including past-practice discharge sites.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of Proton Irradiation on the Performance of Skipper CCDs

Skipper CCDs are a mature detector technology that has been suggested for future space telescope instruments requiring sub-electron readout noise in the near-ultraviolet to the near-infrared. While modern skipper CCDs inherit from the radiation-tolerant p-channel detectors developed by LBNL, the effects of high doses of ionizing radiation on skipper CCDs (such as those expected in space) remains largely unmeasured. We report preliminary results on the performance of p-channel skipper CCDs following irradiation with 217-MeV protons at the Northwestern Medicine Proton Center. The total nonionizing energy loss (NIEL) experienced by the detectors exceeds 6 years at the Sun-Earth Lagrange Point 2 (L2). We demonstrate that the skipper amplifier continues to function as expected following this irradiation. Owing to the low readout noise of these detectors, controlled irradiation tests can be used to sensitively characterize the charge transfer inefficiency, dark current, and the density and time constants of charge traps as a function of proton fluence. We conclude with a brief outlook toward future tests of these detectors at other proton and gamma-ray facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Principal Component Analysis of Nuclear Cable Insulation Subjected to Elevated Temperature and Gamma Radiation

In nuclear power plants (NPPs), the aging of electrical cable insulation occurs due to elevated temperature, ionizing radiation, and other environmental factors. To ensure the safe and efficient operation of NPPs, determination of key indicators of cable aging is critical to predict the remaining useful lifetime of electrical cable insulation. In this work, the effects of simultaneous and sequential thermal and gamma radiation on the aging of cross-linked polyethylene (XLPE) electrical cable insulation are investigated. The chemical changes of the insulation were monitored non-destructively through the use of Fourier transform infrared (FTIR) spectroscopy. The FTIR spectra were measured stepwise after predetermined exposure intervals, with a total irradiation dose up to 320 kGy at a dose rate of 300 Gy/hr in two exposure scenarios; simultaneously aged samples were heated at 150 °C during irradiation, while sequentially aged samples were heated at 150 °C for designated durations followed by corresponding times of irradiation at ambient temperature. A data-driven approach using principal component analysis (PCA) was developed to highlight changes in the carbonyl region of the infrared spectra of the aged samples due to oxidation and to differentiate oxidation rates under the simultaneous and sequential exposure conditions. Findings indicate that the sequential aging scenario may be more conservative than the simultaneous aging scenario for XLPE electrical cable insulation.

Li, Donghui↗

Why ionizing radiation enhances surface wettability

Radiation-Induced Surface Activation is an inherent phenomenon where surfaces that are exposed to gamma irradiation are observed to undergo an increase in wettability. This increase in wettability as a result of the ionizing radiation exposure has so far been demonstrated to have a pronounced impact on Leidenfrost temperature and two-phase fluid dynamics. Test results from previous experiments have shown that incorporation of this effect on heat transfer equipment design may increase the thermal-hydraulic margin leading to higher thermal efficiency. However, the mechanism behind the increased wettability is not clearly understood. In the present work, three different materials (Zircaloy-4, 316 stainless steel, and copper) were exposed at two different dose rates with use of two different gamma irradiation facilities. A detailed surface characterization on the post-irradiated samples is carried out to understand the changes in surface chemistry, wettability and surface morphology. It is observed from the experiments that the increase in wettability upon irradiation depended on the total dose and not on the dose rate. Moreover, localized oxidation and porosity induced by radiolysis was seen to be the predominant mechanism behind increased wettability which leads to improved Leidenfrost temperature.

36 MATERIALS SCIENCE↗

Why ionizing radiation enhances surface wettability

Radiation-Induced Surface Activation is an inherent phenomenon where surfaces that are exposed to gamma irradiation are observed to undergo an increase in wettability. This increase in wettability as a result of the ionizing radiation exposure has so far been demonstrated to have a pronounced impact on Leidenfrost temperature and two-phase fluid dynamics. Test results from previous experiments have shown that incorporation of this effect on heat transfer equipment design may increase the thermal-hydraulic margin leading to higher thermal efficiency. However, the mechanism behind the increased wettability is not clearly understood. In the present work, three different materials (Zircaloy-4, 316 stainless steel, and copper) were exposed at two different dose rates with use of two different gamma irradiation facilities. A detailed surface characterization on the post-irradiated samples is carried out to understand the changes in surface chemistry, wettability and surface morphology. It is observed from the experiments that the increase in wettability upon irradiation depended on the total dose and not on the dose rate. Moreover, localized oxidation and porosity induced by radiolysis was seen to be the predominant mechanism behind increased wettability which leads to improved Leidenfrost temperature.

Seshadria, Arunkumar↗

A Million Person Study Innovation: Evaluating Cognitive Impairment and other Morbidity Outcomes from Chronic Radiation Exposure Through Linkages with the Centers for Medicaid and Medicare Services Assessment and Claims Data

Here, the study of One Million U.S. Radiation Workers and Veterans, the Million Person Study (MPS), examines the health consequences, both cancer and non-cancer, of exposure to ionizing radiation received gradually over time. Recently the MPS has focused on mortality patterns from neurological and behavioral conditions, e.g., Parkinson's disease, Alzheimer's disease, dementia, and motor neuron disease such as amyotrophic lateral sclerosis. A fuller picture of radiation-related late effects comes from studying both mortality and the occurrence (incidence) of conditions not leading to death. Accordingly, the MPS is identifying neurocognitive diagnoses from fee-for-service insurance claims from the Centers for Medicare and Medicaid Services (CMS), among Medicare beneficiaries beginning in 1999 (the earliest date claims data are available). Linkages to date have identified ∼540,000 workers with available health information. Such linkages provide individual information on important co-factor and confounding variables such as smoking, alcohol consumption, blood pressure, obesity, diabetes and many other health and demographic characteristics. The total person-level set of time-dependent variables, outcomes, organ-specific dose measures, co-factors, and demographics will be massive and much too large to be evaluated with standard software. Thus, development of specialized open-source software designed for large datasets (Colossus) is nearly complete. The wealth of information available from CMS claims data, coupled with individual dose reconstructions, will thus greatly enhance the quality and precision of health evaluations for this new field of low-dose radiation and neurocognitive effects.

Dauer, Lawrence T.↗

Impact of high-dose gamma-ray irradiation on electrical characteristics of N-polar and Ga-polar GaN p–n diodes

We investigate the impact of high-dose gamma-ray irradiation on the electrical performance of Ga-polar and N-polar GaN-based p-n diodes grown by metalorganic chemical vapor deposition. We compare the current density-voltage (J-V), capacitance-voltage (C-V), and circular transfer length method (CTLM) characteristics of the p-n diodes fabricated on Ga-polar and N-polar orientations before and after irradiation. The relative turn-on voltage increases for the Ga-polar diodes with increasing irradiation dose, while it increases initially and then starts to decrease for the N-polar diodes. The p-contact total resistance increases for Ga-polar and decreases for N-polar samples, which we attribute to the formation of point defects and additional Mg activation after irradiation. The J-V characteristics of most of the tested diodes recovered over time, suggesting the changes in the J-V characteristics are temporary and potentially due to metastable occupancy of traps after irradiation. X-ray photoelectron spectroscopy (XPS) and photoluminescence (PL) measurements reveal the existence of different types of initial defects and surface electronic states on Ga-polar and N-polar samples. Gallium vacancies (V Ga ) are dominant defects in Ga-polar samples, while nitrogen vacancies (V N ) are dominant in N-polar samples. The presence of a higher concentration of surface states on Ga-polar surfaces compared to N-polar was confirmed by calculating the band bending and the corresponding screening effect due to opposite polarization bound charge and ionized acceptors at the surface. The difference in surface stoichiometry in these two orientations is responsible for the different behavior in electrical characteristics after gamma-ray interactions.

36 MATERIALS SCIENCE↗

Peripheral Blood Transcript Signatures after Internal 131 I-mIBG Therapy in Relapsed and Refractory Neuroblastoma Patients Identifies Early and Late Biomarkers of Internal 131 I Exposures

131 I-metaiodobenzylguanidine ( 131 I-mIBG) is a targeted radiation therapy developed for the treatment of advanced neuroblastoma. We have previously shown that this patient cohort can be used to predict absorbed dose associated with early 131 I exposure, 72 h after treatment. We now expand these studies to identify gene expression differences associated with 131 I-mIBG exposure 15 days after treatment. Total RNA from peripheral blood lymphocytes was isolated from 288 whole blood samples representing 59 relapsed or refractory neuroblastoma patients before and after 131 I-mIBG treatment. We found that several transcripts predictive of early exposure returned to baseline levels by day 15, however, selected transcripts did not return to baseline. At 72 h, all 17 selected pathway-specific transcripts were differentially expressed. Transcripts CDKN1A (P < 0.000001), FDXR (P < 0.000001), DDB2 (P < 0.000001), and BBC3 (P < 0.000001) showed the highest up-regulation at 72 h after 131 I-mIBG exposure, with mean log2 fold changes of 2.55, 2.93, 1.86 and 1.85, respectively. At day 15 after 131I-mIBG, 11 of the 17 selected transcripts were differentially expressed, with XPC, STAT5B, PRKDC, MDM2, POLH, IGF1R, and SGK1 displaying significant up-regulation at 72 h and significant down-regulation at day 15. Interestingly, transcripts FDXR (P = 0.01), DDB2 (P = 0.03), BCL2 (P = 0.003), and SESN1 (P < 0.0003) maintained differential expression 15 days after 131 I-mIBG treatment. These results suggest that transcript levels for DNA repair, apoptosis, and ionizing radiation-induced cellular stress are still changing by 15 days after 131 I-mIBG treatment. Our studies showcase the use of biodosimetry gene expression panels as predictive biomarkers following early (72 h) and late (15 days) internal 131 I exposure. Our findings also demonstrate the utility of our transcript panel to differentiate exposed from non-exposed individuals up to 15 days after exposure from internal 131 I.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗