Engineering PapersSearch

SEARCH · Engineering Papers

Results for “tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

X-Ray Computed Tomography of Apollo Drive Tube 73001 as Part of the Apollo Next Generation Sample Analysis Program

Introduction: Starting in 2019, the Apollo Next Generation Sample Analysis (ANGSA) Program has enabled consortium studies of specially curated Apollo samples that were previously unstudied (or under studied). This program was intended as a participating scientist program for these Apollo samples, as well as a preparation for upcoming lunar sample return missions (e.g., Artemis). The work began with studies of unsealed core tube 73002 [1,2] that is the upper ~35 cm of an Apollo 17 double drive tube (~70 cm total depth) collected on the landslide deposit near Lara Crater at Station 3 in the Taurus Littrow Valley. More recently the program extended to the study of a variety of frozen Apollo 17 samples [3], as well as the gas extraction [4] and dissection [5] of 73001, the lower half of the station 3 double drive tube. Sample 73001 was sealed under vacuum on the Moon in a Core Sample Vacuum Container (CSVC). In this abstract we will examine the role of X-ray Computed Tomography (XCT) during the preliminary examination process for sealed core 73001, including: (1) engineering scans to aid in understanding the gas extraction process, (2) whole-core scanning prior to opening to inform extrusion and dissection work, and (3) individual particle scanning to characterize rock fragment lithologies for follow on studies. Methodology: Sample 73001 is a 33 cm long, 4 cm diameter regolith sample collected inside a lunar drive tube (~1 mm aluminum walls). That drive tube was sealed inside a 0.5 mm thick stainless steel (SS) CSVC. XCT scans for engineering purposes were done on the Nikon XTH 320 system at Johnson Space Center using the 225 kV multi-metal reflection source at 215 kV, 179 A, and a 38.49 m voxel size. Individual >4 mm particles separated from the core during processing (then triply sealed in Teflon bags) were also scanned at JSC using the 180 kV source at 90 kV, 33 A, and a 2.98 – 10.65 m voxel size. Whole-core scans were done at the University of Texas High-Resolution X-ray Computed Tomography Facility (UTCT) on the 225 kV reflection source on the North Star Imaging cabinet XCT system. These scans included: (1) a series of 9 overlapping super-resolution scans each covering a ~4 cm length of the tube at 190 kV, 180 µA, and a 12.9 µm voxel size and (2) a lower resolution continuous helical scan of the entire core at 190 kV, 180 µA, and a 51.8 µm voxel size. Progress and Results: Before piercing and extracting the gas from sample 73001, an XCT scan of the bottom portion of the CSVC was used to confirm the location of the Teflon cap on the inner drive tube and whether there was an “air” gap between the Teflon cap and the CSVC. This was to ensure the Teflon cap (which immobilized the soil inside the drive tube) was not accidentally pierced during gas extraction. Similarly, after piercing, the bottom and top portions of the CSVC were scanned in order to capture engineering knowledge about the results of the piercing process, as well as the metal knife edge vacuum seal (SS into an In-Ag alloy). Both scans will provide constraints on future work of this type, both for the design of tools used on the lunar surface during Artemis, as well as how we open future samples of this type. An unexpected finding from these engineering scans was that the device in the drive tube that immobilizes the regolith (the keeper) was not seated in the tube properly. This meant that (1) the drive tube could not be removed from the CSVC for the trip to UTCT, and (2) the procedure for opening and extruding the drive tube had to be modified. Had either of these things not been known prior to opening the CSVC, it could have led to an inability to XCT scan the whole core at high resolution and/or potential disruption of the core stratigraphy during extrusion. At UTCT, the entire length of the core was scanned at high resolution (12.9 microns per voxel). This scan serves multiple purposes: (1) A lower resolution (and uncorrected) version of these scans stitched together was used to help inform the processors of potential pitfalls during extrusion and dissection (voids, angular fragments at the edges of the sample, etc.); and (2) the full resolution corrected data will serve as the permanent in situ record of the stratigraphy of the sample and will enable future researchers to perform a variety of analyses. All 121 >4 mm particles separated during dissection pass 1 of sample 73001 have been individually scanned. These scans clearly show the lithology of each particle while keeping the particles in pristine condition (they are individually triply bagged in Teflon within our N2 purged processing cabinets). Because of the dust adhering to particle exteriors, it would otherwise be impossible to determine lithologies in a non-contaminating way. Thus far the types of lithologies seen in sample 73001 (e.g., regolith breccias, impact-melt breccias, agglutinates, and bas-alts) are similar to those previously identified in sample 73002 [2]. By the time of the meeting, all particles from all 3 dissection passes will have been scanned and statistics on the different lithologies in 73001 compiled. References: [1] Shearer et al. (2020) 51st LPSC, abstract 1181. [2] Zeigler et al. (2020) 51st LPSC, abstract 3023. [3] Kent et al. (2022) This Volume. [4] McDonald et al. (2022) European Lunar Symposium. [5] Gross et al (2022) This volume.

Moon

3D pore structure reconstruction of fluff region in top of EBR-II irradiated fuel by X-ray micro-computed tomography

Metallic fuels comprised of U-Zr binary and U-Pu-Zr ternary alloys are a promising fuel candidate for sodium-cooled fast reactors and possess many advantages over ceramic fuels such as higher uranium density and improved thermal conductivity. Fluff is a highly porous structure forming at the top of metallic fuel slugs during irradiation and was extensively observed in past sodium-cooled fast reactor (SFR) experiments such as Idaho National Laboratory’s Experimental Breeder Reactor II (EBR-II). Previous investigations have shown that fluff is rich in fissile atoms and hence could have neutronics implications, but its formation mechanisms are not understood. In this work, two cube-shaped lift outs were taken from the fluff and bulk fuel regions of a high burnup U-19Pu-10Zr composition EBR-II fuel slug and characterized by micro computed tomography (Micro-CT) and energy dispersive x-ray spectroscopy (EDS). This was used to characterize differences in microscale porosity and composition between fluff and bulk fuel, and to support or oppose postulated fluff formation mechanisms. Surface EDS showed minimal differences between the elemental compositions of the fluff and fuel cubes. However, three-dimensional (3D) pore analysis from the tomography scans showed significant differences between the fluff and fuel cube pore size distributions at the microscale level. The high porosity and irregular pore distribution seen in macroscale fluff was also present within the micro-scale fluff cube, having a much higher porosity than the fuel cube which was concentrated in a few large pore networks. In conclusion, these results indicate support for a creep driven mechanism of fluff formation.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Tomography of entangling two-qubit logic operations in exchange-coupled donor electron spin qubits

Scalable quantum processors require high-fidelity universal quantum logic operations in a manufacturable physical platform. Donors in silicon provide atomic size, excellent quantum coherence and compatibility with standard semiconductor processing, but no entanglement between donor-bound electron spins has been demonstrated to date. Here we present the experimental demonstration and tomography of universal one- and two-qubit gates in a system of two weakly exchange-coupled electrons, bound to single phosphorus donors introduced in silicon by ion implantation. We observe that the exchange interaction has no effect on the qubit coherence. We quantify the fidelity of the quantum operations using gate set tomography (GST), and we use the universal gate set to create entangled Bell states of the electrons spins, with fidelity 91.3 ± 3.0%, and concurrence 0.87 ± 0.05. These results form the necessary basis for scaling up donor-based quantum computers.

42 ENGINEERING

Optimal 3D chemical imaging with multimodal electron tomography

Accurate mapping of nanoscale chemistry in three dimensions (3D) has been a longstanding challenge. Modern electron microscopy provides chemical images by electron energy loss spectroscopy (EELS) and energy dispersive x-ray spectrometry (EDX) but requires high fluences that damage specimens. In 3D, the requirements are worse; electron tomography demands many high-fluence chemical maps for reconstruction, creating a tradeoff between resolution, accuracy, and sample survival. Fused multimodal electron tomography (MM-ET) alleviates this requirement by leveraging lower-fluence high-angle annular dark-field (HAADF) images alongside a few chemical maps to dramatically improve chemical resolution. Here, experimental and computational parameter space is systematically explored to determine when MM-ET performs best. Ideal imaging conditions balance sample survival with resolution and chemical specificity; we recommend a tilt range of at least ± 70°, acquiring 40 equally spaced HAADF projections (signal-to-noise > 10), and 7 EELS/EDX maps of each chemistry (signal-to-noise > 4).

36 MATERIALS SCIENCE

X-ray tomography of damage dynamics in advanced materials using a laser wakefield accelerator

Additively manufactured (AM) metals offer the potential for customizable, cost-effective components, but qualification and certification are crucial. Key to this process is understanding pore dynamics under stress, typically analyzed using micro-computed tomography. This study introduces laboratory-scale “betatron” x-rays from laser wakefield acceleration as a high-throughput alternative for x-ray tomography of advanced materials, such as AM AlSi10Mg alloys. Coupled with 3D finite element modeling, this method provides detailed insights into stress-porosity interactions. The approach delivers high-resolution scans, revealing that pore shape and local triaxiality significantly influence fracture dynamics, supporting advanced material characterization. This work also demonstrates the potential and versatility of laser-betatron x-ray μCT for generating large datasets to accelerate our understanding of the stochastic, process-specific nature of pore formation in AM alloys.

Senthilkumaran, Vigneshvar

Use of Constrained Gamma Emission Computed Tomography to Evaluate Fission Product Distributions in High-Temperature Materials from a TRISO Fuel Irradiation

An image reconstruction technique was developed to overcome problems with earlier methods of gamma emission computed tomography of graphite rings surrounding the AGR-3/4 TRISO fission product transport experiment. The profiles obtained from the tomography are compared with sampling done via radially resolved destructive sampling techniques. Generally, there is good agreement between profiles measured via destructive sampling of the rings and the tomographic profiles, though at low signal strengths, the tomographic profiles appear elevated.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Strategies for preparing and analyzing thin passive films with atom probe tomography

Atom probe tomography provides a unique, three-dimensional map of elemental and isotopic distributions over a wide range of materials with near-atomic scale resolution and is particularly strong at analyzing buried interfaces within materials. However, it is much more difficult to apply atom probe to the analysis of nanoscale surface films, such as those formed during alloy passivation, where unique challenges persist for sample preparation and data collection. Here, we present sample preparation strategies involving the deposition of a < 100 nm capping layer that enables reliable characterization of thin passive films approximately 2–5 nm thick formed on binary and multi-principal element alloys via atom probe tomography. Several capping layer materials (Pt, Ti, Ni/Cr bi-layer) and deposition methods are contrasted. Our results indicate a sputtered Ni/Cr bi-layer enables the characterization of the entire passive film and concentration profiles that can easily be interpreted to clearly distinguish base alloy/passive film/capping layer interfaces. Lastly, we highlight ongoing challenges and opportunities for this experimental approach.

Kautz, Elizabeth J. [University of Florida]

ATom (Acoustic Tomography Processing Suite) [SWR-24-120]

Acoustic tomography seeks the best-fit fluctuating velocity and temperature fields that explain a collection of signal travel times in a region of interest. This codebase defines an end-to-end framework for executing turbulent field retrievals from acoustic signals, acoustic signal design and processing tools for the physical array, and analysis tool that leverage virtual acoustic tomography arrays based on large-eddy simulations of the atmospheric boundary layer.

Hamilton, Nicholas

Evaluating multi-slice ptychography tomography for X-ray imaging

X-ray ptychography typically relies on single-slice reconstruction approaches that assume minimal beam propagation through the specimen. However, this approximation breaks down for thick samples or when using high numerical aperture optics, leading to reconstruction artifacts due to multiple scattering. Multi-slice ptychographic tomography (MSPT) addresses this limitation by explicitly modeling beam propagation through the specimen while reducing angular sampling requirements for tomography, but its performance depends critically on reconstruction parameters and experimental conditions. Here, we systematically evaluate MSPT using numerical simulations and experimental X-ray datasets to understand how factors such as object thickness, optical parameters, and initialization strategies affect reconstruction accuracy. We demonstrate that informed object initialization significantly improves depth resolution and enables accurate projection extension, reducing the angular sampling requirements for tomographic reconstruction. Experimental demonstration confirms that MSPT produces reconstructions with reduced artifacts, establishing it as a robust approach for nanoscale imaging at modern synchrotron facilities.

Luktuke, Amey [Argonne National Laboratory (ANL),

Deployed quantum link characterization via Bayesian ancilla-assisted process tomography

The development of large-scale quantum networks requires reliable quantum channels, the quality of which can be quantified by the framework of quantum process tomography. Here, in this work, we leverage ancilla-assisted process tomography (AAPT) and Bayesian inference to probe a 1.6 km deployed fiber-optic link. We send one of the two polarization-entangled photons at Alice in one building to Bob in another, exploiting the local qubit as an ancilla system to characterize the corresponding quantum channel. Monitoring over a 24 h period returns a steady process fidelity of 97.6(1)%, while controllable spectral filtering with passbands from 0.025 to 4.38 THz finds fidelities that first increase, and then level off with bandwidth, suggesting both stable operation with time and minimal polarization mode dispersion. To our knowledge, these results represent the first AAPT of a deployed quantum link, revealing a valuable tool for in situ analysis of entanglement-based quantum networks.

Rahman, Arefur [Arizona State Univ., Tempe, AZ (Un

Laser-driven high-resolution MeV x-ray tomography

The need for high-resolution MeV x-ray tomography to observe the three-dimensional structure of dense, large-sized objects is rapidly increasing for the non-destructive evaluation of critical additively manufactured parts, national security, and other applications. We report a demonstration of high-resolution MeV computed tomography of a dense, large object with a laser-driven x-ray source. A record detector-limited MeV radiograph resolution of < 200 µm as determined with the Bennett approximation of the point spread function was achieved by irradiating millimeter-thick tungsten targets with 300 TW femtosecond laser pulses at a 0.5 Hz repetition rate. A tungsten alloy step wedge spectrometer indicates that the peak of the x-ray emission is between 1 and 2 MeV, with an endpoint energy of 19 MeV. To illustrate the radiographic imaging capability of the system, a tomographic reconstruction of a nickel superalloy turbine blade ( maximum $ρr$ = 139 g/cm 2 ) with sub-millimeter resolution was performed using 2160 individual radiographs. The small x-ray source size opens the prospect of extremely high-resolution tomographs of large, dense objects. This laser-driven approach has major advantages for non-destructive evaluation.

47 OTHER INSTRUMENTATION

Improved Regional Moment Tensor Inversion for Moderately Large Earthquakes in the Western United States Using a 3D Earth Model Based on Full Waveform Tomography

The nature of seismic sources for moderately large (moment magnitude, M w 5.0–6.5) events are commonly characterized by their moment tensor (MT) solutions and obtained by inversion of regional distance (200–1600 km) long‐period (20–50 s) waveforms. Regional MT estimates are often calculated from average plane‐layered, one‐dimensional (1D) velocity models. However, 1D model calculations can produce misfits in the arrival times and waveform shapes that introduce errors, particularly at longer distances or for shorter periods, which are necessary for analyzing lower magnitude events. Approximate Earth models (e.g., 1D) representing broad areas may be inadequate, particularly in the crust and uppermost mantle of tectonically complex regions. In this study, we show how a three‐dimensional (3D) Earth model obtained from full waveform inversion tomography can improve waveform fits and decrease phase errors. We developed a platform and workflow to perform routine 3D MT inversions and inverted MTs for 25 earthquakes in the western United States and seven nuclear explosions using an average 1D and a recent 3D Earth model, WUS256 (Rodgers et al., 2022). Using the 3D model improves waveform fits (variance reduction and phase time shifts) compared with the 1D model, and the 3D MT solutions are stable across large distances. This study shows that 3D models obtained from full waveform tomography can improve MTs and source characterization especially at far regional distances (>800 km).

Geosciences

Adjoint waveform tomography of East Asia for improved waveform prediction

We present a preliminary version of the East Asia Tomography (EAT) model, an adjoint waveform tomography model of East and Southeast Asia. We used SPiRaL (Simmons et al., 2021) as our starting model and source parameters for 238 earthquakes from the Global Centroid Moment Tensor catalogue (Ekström et al., 2012). After 50 iterations on Lawrence Livermore National Laboratory’s Lassen supercomputer, we converge on a model with a minimum period of 50 seconds. The preliminary model shows improved slab structure compared to SPiRaL and shows significantly reduced misfit. In later versions of the model, we aim to harness techniques proposed in other studies to improve waveform predictions that travel through the ocean (e.g., Wehner et al., 2022) and use relative amplitude-based misfit functions (e.g., Tao et al., 2018) to better constrain Earth structure. We hope to iterate the current extent of the model to 25 seconds minimum period before iterating to shorter periods for a smaller subregion of the full model.

58 GEOSCIENCES

Technical Report on Adjoint Waveform Tomography of East Asia for Improved Waveform Prediction

We present a preliminary version of the East Asia Tomography (EAT) model, an adjoint waveform tomography model of East and Southeast Asia. We used SPiRaL (Simmons et al., 2021) as our starting model and source parameters for 250 earthquakes from the Global Centroid Moment Tensor catalogue (Ekström et al., 2012). Over 198 iterations, we have iterated the EAT model down to a minimum period of 35 seconds. We plan on continuing our iteration technique down to 30 seconds period before updating our misfit function to use a normalized cross correlation-based misfit functions (e.g., Tao et al., 2018) to better constrain Earth structure. We hope to iterate the current extent of the model to 25 seconds minimum period before iterating to shorter periods for a smaller subregion of the full model.

58 GEOSCIENCES

Longitudinal Phase Space Tomography for the Booster Synchrotron

Efforts in the study of the longitudinal behavior of charged particles in the Fermilab Booster can be catalyzed with an image of the two-dimensional phase space distribution. In the past, tomography has been extensively employed in the reconstruction of the phase space in accelerators such as the Recycler at Fermilab and the Proton Synchrotron Booster at CERN. However, such a capability had yet to realize for the Fermilab Booster synchrotron. In this work, the first successful tomographic phase space reconstruction of a low-energy Booster bunch is presented along with validation metrics. A numerical turn-by-turn model of the longitudinal particle dynamics in the Booster has been implemented, which utilizes a fast, map-based particle transport algorithm. Using a sinogram generated from the Wall Current Monitor, the iterative reconstruction algorithm recovers a discretized image of the original phase space distribution at variable resolution. The reconstruction result shows low root-mean-square error and a rapid convergence toward the solution, providing strong evidence of accuracy. Future and ongoing work includes modeling high-energy bunches above transition and using tomography to infer certain machine parameters such as synchronous phase, peak gap voltage, and synchronous energy in addition to the phase space distribution.

Ebeid, Safi [Unlisted]

Longitudinal Phase Space Tomography for the Booster Synchrotron (Abstract Only)

Efforts in the study of the longitudinal behavior of charged particles in the Fermilab Booster can be catalyzed with an image of the two-dimensional phase space distribution. In the past, tomography has been extensively employed in the reconstruction of the phase space in accelerators such as the Recycler at Fermilab and the Proton Synchrotron Booster at CERN. However, such a capability had yet to realize for the Fermilab Booster synchrotron. In this work, the first successful tomographic phase space reconstruction of a low-energy Booster bunch is presented along with validation metrics. A numerical turn-by-turn model of the longitudinal particle dynamics in the Booster has been implemented, which utilizes a fast, map-based particle transport algorithm. Using a sinogram generated from the Wall Current Monitor, the iterative reconstruction algorithm recovers a discretized image of the original phase space distribution at variable resolution. The reconstruction result shows low root-mean-square error and a rapid convergence toward the solution, providing strong evidence of accuracy. Future and ongoing work includes modeling high-energy bunches above transition and using tomography to infer certain machine parameters such as synchronous phase, peak gap voltage, and synchronous energy in addition to the phase space distribution.

Ebeid, Safi [Unlisted, US]

Dual-unitary shadow tomography

We introduce a classical shadow tomography scheme based on dual-unitary brick-wall circuits termed "dual-unitary shadow tomography" (DUST). For this we study operator spreading and Pauli weight dynamics in one-dimensional qubit systems, evolved by random two-local dual-unitary gates arranged in a brick-wall structure, ending with a final measurement layer. We do this by deriving general constraints on the Pauli weight transfer matrix and specializing to the case of dual-unitarity. We first show that dual-unitaries must have a minimal amount of entropy production. Remarkably, we find that operator spreading in these circuits have a rich structure resembling that of relativistic quantum field theories, with massless chiral excitations that can decay or fuse into each other, which we call left- or right-movers. We develop a mean-field description of the Pauli weight in terms of $\rho(x,t)$, which represents the probability of having nontrivial support at site $x$ and depth $t$ starting from a fixed weight distribution. We develop an equation of state for $\rho(x,t)$, and simulate it numerically using Monte Carlo simulations. Lastly, we demonstrate that the fast-thermalizing properties of dual-unitary circuits make them better at predicting large operators than shallow brick-wall Clifford circuits. Our results are robust to finite-size effects due to the chirality of dual-unitary brick-wall circuits.

97 MATHEMATICS AND COMPUTING

Neutrino tomography - Tevatron mapping versus the neutrino sky

The feasibility of neutrino tomography of the earth's interior is discussed, taking the 80-GeV W-boson mass determined by Arnison (1983) and Banner (1983) into account. The opacity of earth zones is calculated on the basis of the preliminary reference earth model of Dziewonski and Anderson (1981), and the results are presented in tables and graphs. Proposed tomography schemes are evaluated in terms of the well-posedness of the inverse-Radon-transform problems involved, the neutrino generators and detectors required, and practical and economic factors. The ill-posed schemes are shown to be infeasible; the well-posed schemes (using Tevatrons or the neutrino sky as sources) are considered feasible but impractical.

Wilson, T. L.