Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tilt”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Measurement of Transcranial Distance During Head-Down Tilt Using Ultrasound

Exposure to microgravity probably elevates blood pressure and flow in the head which may increase intracranial volume (ICV) and pressure (ICP). Due to the slightly compliant nature of the cranium, any increase of ICP will increase ICV and transcranial distance. We used a noninvasive ultrasound technique to measure transcranial distance (frontal to occipital) during head-down tilt. Seven subjects (ages 26-53) underwent the following tilt angles: 90 deg. upright, 30 deg., 0 deg., -6 deg., -10 deg., -6 deg., 0 deg., 30 deg., and 90 deg. Each angle was maintained for 1 min. Ultrasound wave frequency was collected continuously and transcranial distance was calculated (Delta(x) = x(Delta)f/f, where x is path length and f is frequency of the wave) for each tilt angle. Frequency decreased from 503.687 kHz (90 deg. upright) to 502.619 kHz (-10 deg.). These frequencies translated to an increased transcranial distance of 0.403 mm. Although our data suggest a significant increase in transcranial distance during head-down tilt, this apparent increase may result, in part, from head-down tilt-induced subcutaneous edema or cutaneous blood volume elevation. In three subjects, when the above protocol was repeated with an ace bandage wrapped around the head to minimize such edema, the increased transcranial distance from 90 deg. to -10 deg. was reduced by 0.174 mm. Further development of the technique to quantify bone-to-bone expansion unconfounded by cutaneous fluid is necessary. Therefore, this ultrasound technique may provide measurements of changes in cranial dimensions during microgravity.

Torikoshi, Shigeyo↗

Destabilization of Human Balance Control by Static and Dynamic Head Tilts

To better understand the effects of varying head movement frequencies on human balance control, 12 healthy adult humans were studied during static and dynamic (0.14,0.33,0.6 Hz) head tilts of +/-30deg in the pitch and roll planes. Postural sway was measured during upright stance with eyes closed and altered somatosensory inputs provided by a computerized dynamic posturography (CDP) system. Subjects were able to maintain upright stance with static head tilts, although postural sway was increased during neck extension. Postural stability was decreased during dynamic head tilts, and the degree of destabilization varied directly with increasing frequency of head tilt. In the absence of vision and accurate foot support surface inputs, postural stability may be compromised during dynamic head tilts due to a decreased ability of the vestibular system to discern the orientation of gravity.

Paloski, William H.↗

Use of Minute-by-Minute Cardiovascular Measurements During Tilt Tests to Strengthen Inference on the Effect of Long-Duration Space Flight on Orthostatic Hypotension

Typical methodology for evaluating the effects of spaceflight on orthostatic hypotension (OH) has been survival analysis of tolerance times from 80 head-up tilt tests. However when scheduled test durations are short, there may not be enough failures to allow survival analysis to adequately estimate and compare the effects of flight phase (e.g. pre-flight, number of days post-flight), flight duration, and their interaction, as well as interactions with effects of interventions or countermeasures. The problem is exacerbated in the presence of a repeated measures design, in which subjects participate in tilt tests during various flight phases. Here we show how it is possible to dramatically improve the efficiency of statistical inference in this setting by making use of the additional information contained in minute-by-minute observations of cardiovascular parameters thought to be reflective of progression towards presyncope during tilt testing. Methods: We retrospectively examined operational tilt test (OTT; 10 -min 80 head-up tilt) data from 20 International Space Station (ISS) and 66 Shuttle astronauts 10 d before launch (L-10), on landing day (R+0) and during recovery (R+1, R+3, R+6-10) depending on the level of participation. Data from 5 ISS astronauts tested on R+0 or R+1 who used non-standard countermeasures were excluded. In addition to OTT survival time, 8 cardiovascular parameters (CP: heart rate, systolic, diastolic, and mean arterial blood pressure, pulse pressure, stroke volume, cardiac output, and total peripheral resistance) that might be predictive of progression towards presyncope were measured every minute of each OTT. Statistical analysis was predicated on a two ]stage model of causation. In the first stage, flight duration and time from landing affect the astronauts' degree of OH, which is manifested in the time trends and variation of the above CPs during OTTs. In the second stage, the behavior of these parameters directly affects OTT survival time. Actual analysis proceeded in the opposite direction. First we identified those CPs or linear combinations that best predicted OTT survival regardless of what spaceflight conditions led to OTT completion or presyncope. From these, we calculated a summary statistic (one per OTT) that best predicted survival. We then used mixed ]model regression analysis to relate changes in the summary statistic to flight phase and duration. Inference on the effects of phase, duration, and their interaction on OH follows directly from this second analysis. Results: A linear combination (W) of diastolic blood pressure (DBP) and stroke volume (SV) was found to be the best predictor of OTT survival using the complete data set of minute-by-minute observations of CPs for each OTT. Furthermore, the log-transformed standard deviation of W (Z = log SW) was found to be a strong predictor of survival in the reduced data set consisting of one observation per OTT. In other words, this measure of variability of W during an OTT was the best indicator of whether or not the subject could complete the 10-min test, with higher variability (i.e. higher values of Z) being associated with greater probability of failure. In the mixed-model regression analysis where Z was now treated as a outcome with flight phase and duration groups (ISS and STS) as predictors, we found that there was a significantly more variability in W (higher values of Z) for both groups at R+0, but with no evidence of an interaction until R+3, when the ISS group still had inflated variability, but not the STS group. Conclusions: Variability of the cardiovascular index W recovers more slowly after long-compared to short-duration spaceflight. Since high variability of W has also been shown to be predictive of OTT failure, a primary manifestation of OH, a logical conclusion is that recovery from OH also is slower after long-duration compared to short-duration spaceflights.

Feiveson, Alan H.↗

Spatial Coding of Eye Movements Relative to Perceived Orientations During Roll Tilt with Different Gravitoinertial Loads

This purpose of this study was to examine the spatial coding of eye movements during roll tilt relative to perceived orientations while free-floating during the microgravity phase of parabolic flight or during head tilt in normal gravity. Binocular videographic recordings obtained in darkness from six subjects allowed us to quantify the mean deviations in gaze trajectories along both horizontal and vertical coordinates relative to the aircraft and head orientations. Both variability and curvature of gaze trajectories increased during roll tilt compared to the upright position. The saccades were less accurate during parabolic flight compared to measurements obtained in normal gravity. The trajectories of saccades along perceived horizontal orientations tended to deviate in the same direction as the head tilt, while the deviations in gaze trajectories along the perceived vertical orientations deviated in the opposite direction relative to the head tilt. Although subjects were instructed to look off in the distance while performing the eye movements, fixation distance varied with vertical gaze direction independent of whether the saccades were made along perceived aircraft or head orientations. This coupling of horizontal vergence with vertical gaze is in a consistent direction with the vertical slant of the horopter. The increased errors in gaze trajectories along both perceived orientations during microgravity can be attributed to the otolith's role in spatial coding of eye movements.

Wood, Scott↗

Feasibility Study of a Multi-Tilt-Rotor Aircraft as the Artemis Lunar Training Vehicle

The Lunar Landing Research Vehicles (LLRVs) and the Lunar Landing Training Vehicles (LLTVs) provided astronauts of the Apollo program with essential experience and confidence required to complete the missions, and contributed to six successful manned landings on the moon. The primary challenge in terrestrial training was being able to replicate the ratio of tilt angle to linear acceleration that a pilot would experience in lunar gravity. Presently, as the Artemis program seeks to return humans to the Moon by 2025, engineers are evaluating suitable platforms to serve as an In-Flight Trainer (IFT) or Artemis Lunar Training Vehicle (ALTV) for astronauts training in the task of manual landing. The program is investigating the viability of current technology in the field of electric vertical takeoff and landing (eVTOL) vehicles and is evaluating using a multi-tilt-rotor aircraft platform as a candidate for a preliminary ALTV. The tilt-rotor capability enables the vehicle attitude to be decoupled from its flight path, which is a crucial requirement in realistically simulating lunar gravity on Earth. Other key considerations include compensating for a lack of aerodynamic forces while flying through the atmosphere of Earth, as well as the ability to simulate the dynamics of multiple different lander designs for the Human Landing System (HLS) program. This paper details the feasibility study and presents a preliminary flight control architecture for an IFT based on a notional multi-tilt-rotor platform. The model-following control law, based on nonlinear dynamic inversion (NDI), removes the need for gain scheduling. The inner-loop dynamic control allocation strategy consists of a static portion that is optimized offline for trim while compensating for the difference in gravity and a dynamic portion that is computed in real time. The reference model consists of the full closed-loop dynamics of a generic HLS design. The modularity of the flight control architecture enables evaluation of multiple HLS concepts with minimal modifications to the control law. Simulation results of the multi-tilt-rotor configuration following the final portion of the Apollo 11 descent trajectory are shown.

Jing Pei↗

JWST NIRCam Defocused Imaging Photometric Stability Performance and How It Can Sense Mirror Tilts

We use JWST NIRCam short-wavelength photometry to capture a transit lightcurve of the exoplanet HAT-P-14 b to assess performance as part of instrument commissioning. The short-wavelength precision is 152 ppm per 27 s integration as measured over the full time series compared to a theoretical limit of 107 ppm, after corrections to spatially correlated 1/f noise. Persistence effects from charge trapping are well fit by an exponential function with short characteristic timescales, settling on the order of 5–15 minutes. The short-wavelength defocused photometry is also uniquely well suited to measure the real-time wave-front error of JWST. Analysis of the images and reconstructed wave-front maps indicates that two different hexagonal primary mirror segments exhibited “tilt events,” where they changed orientation rapidly in less than ∼1.4 s. In some cases, the magnitude and timing of the flux jumps caused by tilt events can be accurately predicted with a telescope model. These tilt events can be sensed by simultaneous longer-wavelength NIRCam grism spectral images alone in the form of changes to the point-spread function, diagnosed from the full width at half maximum. They can also be sensed with the fine guidance sensor instrument from difference images. Tilt events possibly from sudden releases of stress in the backplane structure behind the mirrors were expected during the commissioning period because they were found in ground-based testing. Tilt events have shown signs of decreasing in frequency but have not disappeared completely. The detectors exhibit some minor (less than 1%) deviations from linear behavior in the first few groups of each integration, potentially impacting absolute fluxes and transit depths on bright targets, where only a handful of groups are possible. Overall, the noise is within 50% of the theoretical photon noise and read noise. This bodes well for high-precision measurements of transiting exoplanets and other time variable targets.

Everett Schlawin↗

Contribution of perfusion pressure to vascular resistance response during head-up tilt

We measured brachial and femoral artery flow velocity in eight subjects and peroneal and median muscle sympathetic nerve activity (MSNA) in five subjects during tilt testing to 40 degrees. Tilt caused similar increases in MSNA in the peroneal and median nerves. Tilt caused a fall in femoral artery flow velocity, whereas no changes in flow velocity were seen in the brachial artery. Moreover, with tilt, the increase in the vascular resistance employed (blood pressure/flow velocity) was greater and more sustained in the leg than in the arm. The ratio of the percent increase in vascular resistance in leg to arm was 2.5:1. We suggest that the greater vascular resistance effects in the leg were due to an interaction between sympathetic nerve activity and the myogenic response.

NASA Discipline Cardiopulmonary↗

Human cutaneous vascular responses to whole-body tilting, Gz centrifugation, and LBNP

We hypothesized that gravitational stimuli elicit cardiovascular responses in the following order with gravitational stress equalized at the level of the feet, from lowest to highest response: short-(SAC) and long-arm centrifugation (LAC), tilt, and lower body negative pressure (LBNP). Up to 15 healthy subjects underwent graded application of the four stimuli. Laser-Doppler flowmetry measured regional skin blood flow. At 0.6 G(z) (60 mmHg LBNP), tilt and LBNP similarly reduced leg skin blood flow to approximately 36% of supine baseline levels. Flow increased back toward baseline levels at 80-100 mmHg LBNP yet remained stable during 0.8-1.0 G(z) tilt. Centrifugation usually produced less leg vasoconstriction than tilt or LBNP. Surprisingly, SAC and LAC did not differ significantly. Thigh responses were less definitive than leg responses. No gravitational vasoconstriction occurred in the neck. All conditions except SAC increased heart rate, according to our hypothesized order. LBNP may be a more effective and practical means of simulating cardiovascular effects of gravity than centrifugation.

Motor Activity/physiology↗

Wind Tunnel Testing of a 120th Scale Large Civil Tilt-Rotor Model in Airplane and Helicopter Modes

In April 2012 and October 2013, NASA and the U.S. Army jointly conducted a wind tunnel test program examining two notional large tilt rotor designs: NASA's Large Civil Tilt Rotor and the Army's High Efficiency Tilt Rotor. The approximately 6%-scale airframe models (unpowered) were tested without rotors in the U.S. Army 7- by 10-foot wind tunnel at NASA Ames Research Center. Measurements of all six forces and moments acting on the airframe were taken using the wind tunnel scale system. In addition to force and moment measurements, flow visualization using tufts, infrared thermography and oil flow were used to identify flow trajectories, boundary layer transition and areas of flow separation. The purpose of this test was to collect data for the validation of computational fluid dynamics tools, for the development of flight dynamics simulation models, and to validate performance predictions made during conceptual design. This paper focuses on the results for the Large Civil Tilt Rotor model in an airplane mode configuration up to 200 knots of wind tunnel speed. Results are presented with the full airframe model with various wing tip and nacelle configurations, and for a wing-only case also with various wing tip and nacelle configurations. Key results show that the addition of a wing extension outboard of the nacelles produces a significant increase in the lift-to-drag ratio, and interestingly decreases the drag compared to the case where the wing extension is not present. The drag decrease is likely due to complex aerodynamic interactions between the nacelle and wing extension that results in a significant drag benefit.

Wind Tunnel Testing of a 1/20th Scale↗

Comparative orthostatic responses - Standing vs. head-up tilt

In both physiologic and clinical studies, standing is often loosely equated with head-up tilt (HUT) although the cardiovascular effects of these variants of orthostasis have not been formally compared, except for heart rate. The effects of HUT and standing were measured noninvasively in male volunteers satisfying identical criteria for age and normal status. In both postures, there were significant increases in heart rate, pre-ejection period, isovolumic contraction time, and the ratio of pre-ejection to ejection period, and significant decreases in ejection period and ejection time index. All of these changes were greater for standing than for tilt. Pulse transmission time changed significantly (-14%) only with tilt. We conclude that head-up tilt and standing are rather comparable but not physiologically identical forms of orthostasis.

Spodick, D. H.↗

Experimental studies of effects of tilt and structural asymmetry on vibration characteristics of thin-wall circular cylinders partly filled with liquid

The effects of tilt and structural asymmetry on the vibration characteristics of partly liquid-filled thin-wall cylinders were experimentally studied. It was found that tilting the longitudinal axis of a partly filled axisymmetric cylinder from the vertical could markedly reduce its resonant frequencies and change significantly the shape of the circumferential modes. For the minimum frequency modes, vibratory motion occurred only on that side of the cylinder where the liquid was deepest. An empirical equation was derived that gives the equivalent liquid depth of an untilted cylinder having the same minimum resonant frequency as a tilted, partly filled cylinder. Circumferential mode shapes of an untilted asymmetric cylinder were similar to those of the tilted, partly filled axisymmetric cylinder. Vibratory motion in the minimum frequency modes occurred in most instances only on the side of minimum thickness. Correlation between test data and results from a reformulated NASTRAN hydroelastic analysis was excellent.

Herr, R. W.↗

Use of the tilt cue in a simulated heading tracking task

The task was performed with subjects using visual-only cues and combined visual and roll-axis motion cues. Half of the experimental trials were conducted with the simulator rotating about the horizontal axis; to suppress the tilt cue, the remaining trials were conducted with the simulator cab tilted 90 deg so that roll-axis motions were about earth vertical. The presence of the tilt cue allowed a substantial and statistically significant reduction in performance scores. When the tilt cue was suppressed, the availability of motion cues did not result in significant performance improvement. These effects were accounted for by the optimal-control pilot/vehicle model, wherein the presence or absence of various motion cues was represented by appropriate definition of the perceptual quantities assumed to be used by the human operator.

Levison, W. H.↗

Implications of cavity, topographic and geologic influences on tilt and strain observations

Tilt and strain observations are importantly (pathologically at the 100%, typically at the few 10s% level) affected by cavities, topography, and geological inhomogenities; gravity observation are practically unaffected. The traditional earth tide observatory and abandoned mine or tunnel is a very poor place to measure body tides because of the complicated cavities, topography and geology. Instead, the ideal site for observing the body tide is in flat terrain with horizontally layered, mechanically homogeneous geology. Strain will be measured with long surface- or trench-mounted laser strain meters and tilt with long, surface- or trench mounted liquid levels, or with borehole tiltmeters. Horizontal geological discontinuities can produce large perturbations of the tilt and strain tides, and these perturbations, using the known homogeneous tidal strains and tilts, can be used in exploring local structure in favorable cases and, through possible time variations of tidal admittances, in predicting earthquakes.

Harrison, J. C.↗

Cardiopulmonary readjustments in passive tilt

The readjustment of cardiopulmonary variables in human volunteers at various tilt angles on a tilt board is studied. Five healthy subjects (18-31 yr) with thorough knowledge of the experimental protocol are tested, passively tilted from the supine to the upright position in 15-deg increments in random sequence. The parameters measured are cardiac output (Q), heart rate (HR), stroke volume (SV), minute and alveolar ventilation /V(E) and V(A)/, functional residual capacity (FRC), and arterial-end-tidal P(CO2) pressure difference. It is found that changes in Q and FRC are linearly related to the sine of the tilt angle, indicating that either reflexes are absent or their net effect is proportional to the effects of gravity. This is clearly not the case for other variables /HR, SV, V(E), V(A)/, where it is possible to demonstrate threshold values for the appearance of secondary changes.

Matalon, S. V.↗

Performance of end-face seals with diametral tilt and coning - Hydrostatic effects

A face seal model is analyzed, taking into account both diametral tilt and coning of the primary seal ring. The Reynolds equation for incompressible fluid is solved analytically using the narrow seal approximation. The solution covers a wide range of tilt and coning angles, from complete alignment to touch-down. Seal performance like axial force, tilting moment, axial and angular stiffness, and leakage are analyzed. It is found that interaction between diametral tilt and coning strongly affects seal performance.

Etsion, I.↗

A pad perturbation method for the dynamic coefficients of tilting-pad journal bearings

A pad assembly method for analyzing tilting-pad bearings is presented. The method results in the complete coefficient matrix for a tilting-pad bearing; the matrix is independent of the pad inertia, the pitch frequency and the number of degrees of freedom of the pad. A pad assembly method is used because it allows the collection of more bearing data with less computer time than a brute force iterative procedure. The results given show the complete dynamical matrices for a five-pad tilting-pad bearing both including and ignoring the damping effects of the unloaded (top) pads. For a symmetrical tilting-pad bearing the reduced cross-coupling coefficients are zero when the moment of inertia of the pad is ignored.

Allaire, P. E.↗

An assessment of the capability to calculate tilting prop-rotor aircraft performance, loads and stability

Calculated performance, loads, and stability of the XV-15 tilt rotor research aircraft are compared with wind tunnel and flight measurements, to define the level of the current analytical capability for tilting prop rotor aircraft, and to define the requirements for additional experimental data and further analysis development. The correlation between calculated and measured behavior is generally good, although there are some significant discrepancies. Based on this correlation, the analysis is assessed overall as being adequate for the design, evaluation, and testing of tilting prop rotor aircraft. A general assessment of the state of the art of tilt rotor predictive capability is given. Specific areas are identified where improvements in the capability to calculate performance, loads, and stability are desirable. Requirements for more accurate and detailed data which support the development of improved analytical models are identified as well.

Johnson, W.↗

Tilt from a head-inverted position produces displacement of visual subjective vertical in the opposite direction

Observers who lie supine with their heads inverted report large (up to 60 deg) tilt of a light line in an otherwise dark room when their heads and/or bodies are tilted. Most observers report that visual subjective vertical is tilted in the direction opposite to the head/body tilt. The results can be interpreted by employing a model developed by Mittelstaedt (1983), which suggests that visual subjective vertical is derived from a gravity vector transduced by vestibular and somesthetic receptors combined with 'idiotropic vectors' that represent the orientation of the observer's own head and body axes.

Parker, D. E.↗