Electrode Surface Thermometry with Ultrafast Luminescence
Poster presentation for the Gordon Research Conference
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Poster presentation for the Gordon Research Conference
Update presentation on thermographic phosphor digital image correlation for the SEM Annual meeting
Explore the source record for details and available documents.
Network for compensating electrical output of thin film resistance thermometers for deviations due to large heat-transfer rates
Thermocouple wire tested and thermoelectric measurements verified in cryogenic temperature range
Linear regression analysis of water pressure and critical temperature in plagioclase-silicate liquid equilibrium
Ultrasonic pulse techniques have been developed which, when applied to inert gases, provide temperature measurements up to 8000 K. The response time can be less than 1 msec. This is a significant feature in studying shock-heated or combusting gases. Using a momentary contact coupling technique, temperature has been measured inside steel from 300 to 1500 K. Thin-wire sensors have been used above 2000 K in nuclear and industrial applications where conditions preclude the use of thermocouples, resistance devices, or optical pyrometers. At 2500 K, temperature sensitivity of 0.1% is obtained in Re wire sensors 5 cm long by timing five round trips with an electronic instrument that resolves the time interval between selected echoes to 0.1 microsec. Sensors have been operated at rotational speeds over 2000 rpm and in noisy environments. Temperature profiling of up to ten regions using only a single guided path or beam has also been accomplished.
The possibility of standard low temperature detector(s) for use in upcoming cryogenically cooled satellite and Space Shuttle Payloads was investigated. These payloads operate from .3 Kelvin to 300 Kelvin. Standard detectors were selected and matching signal conditioning equipment were specified. This equipment will operate in a spacecraft environment and be compatible with the selected detector, typical spacecraft voltages, typical spacecraft telemetry systems, and the radiation encountered by a typical earth orbiting spacecraft. Work statements to better define and advance detector performance are presented.
Coherent anti Stokes Raman scattering (CARS) from the pure rotational Raman lines of N2 was employed to measure the instantaneous (10 nsec) rotational temperature of the gas at room temperature and below. An entire rotational CARS spectrum was generated by a single laser pulse using a broad bandwidth dye laser and was recorded on an optical multichannel analyzer. A best fit temperature obtained for individual experimental spectra by comparison with calculated spectra. Good agreement between CARS temperatures and thermocouple temperatures was observed.
The possibility of standard low temperature detector(s) for use in upcoming cryogenically cooled satellite and Space Shuttle payloads were investigated. These payloads operate from .3 kelvin to 300 kelvin. Standard detectors were selected and matching signal conditioning equipment compatible with the selected detector, typical spacecraft voltages, typical spacecraft telemetry systems, and the radiation encountered by a typical Earth orbiting spacecraft. Work statements to better define and advance detector performance were presented.
A technique suitable for measuring fluctuating temperatures in supersonic turbulent flows of N2 seeded with NO has been demonstrated in a nonflowing cell. The method relies on the two photon excitation of two selected ro-vibronic transitions in the NO gamma (alpha 2 sigma+, v prime = 0 yields ch1zp1, v double prime = 0).
A technique suitable for measuring fluctuating temperatures in supersonic turbulent flows of N2 seeded with NO has been demonstrated in a nonflowing cell. The method relies on the two photon excitation of two selected ro-vibronic transitions in the NO gamma (alpha 2 sigma+, v prime = 0 yields ch1zp1, v double prime = 0). Previously announced in STAR as N83-20079
A concept is being explored that an optical analog of the electrical Johnson noise may be used to measure temperature independently of emissivity. The concept is that a laser beam may be modulated on reflection from a hot surface by interaction of the laser photons with the thermally agitated conduction electrons or the lattice phonons, thereby adding noise to the reflected laser beam. If the reflectance noise can be detected and quantified in a background of other noise in the optical and signal processing systems, the reflectance noise may provide a noncontact measurement of the absolute surface temperature and may be independent of the surface's emissivity.
A preliminary evaluation was made by ORNL of a two-color ratio pyrometer (TCRP) for temperature control in the Modular Electromagnetic Levitation (MEL) experiment. A discussion was presented by Eric Spjut at the 1987 NASA Non-Contact Temperature Measurement Workshop (NASA Conf. Publ. 2503, pp. 182-213) in which he described the non-linear characteristics of the time response of TCPs. Researchers replicated his model and results and note that the non-linear response behavior is minimized for small temperature steps at high temperatures. They then used the predicted response in a model for a proportional or integral feedback controller and predicted the control characteristics for heating and cooling a 5-mm diameter sphere of niobium at high (1500 to 2750 K) temperatures. The analysis shows that for a slow (25-ms) time response for a commercial RCRP, overshoots of several hundred kelvins will result from a 100-K decrease in the setpoint, and temperature tracking errors of 14 to 45 K will occur for control temperature ramps of 1000K/s. For a fast (greater than 0.1 ms) time response, the overshoot and ramp response errors are largely eliminated.
The present study, which has demonstrated the feasibility of using time-resolved laser-induced fluorescence methods to ascertain boundary layer temperature distributions in real time for hypersonic vehicles in atmospheric flight, employs conventional optics in combination with novel time-resolved spectroscopy. The radiative lifetime and signal intensity involved, both of which are reduced by quenching, are adequate for measurement with state-of-the-art time-resolved fluorescence techniques, except for certain conditions associated with both the highest speeds and the lowest altitudes.
Thermodynamic properties of the alpha/beta phase transformation in terrestrial troilite (FeS), as measured by differential scanning calorimetry (DSC), vary systematically with prior thermal history of the troilite, as imposed under laboratory conditions. Both the transition temperature and enthalpy change for the alpha/beta transformation decrease with increasing maximum temperature of prior heat treatment. DSC measurements on troilite from various meteorites indicate clear differences in the alpha/beta thermodynamic properties that are consistent with differences in the natural thermal histories of the meteorites.
An optical fiber thermometer consists of an optical fiber whose sensing tip is given a metallic coating. The sensing tip of the fiber is essentially an isothermal cavity, so the emission from this cavity will be approximately equal to the emission from a blackbody. Temperature readings are obtained by measuring the spectral radiative heat flux at the end of the fiber at two wavelengths. The ratio of these measurements and Planck's Law are used to infer the temperature at the sensing tip. Optical fiber thermometers have high accuracy, excellent long-term stability and are immune to electromagnetic interference. In addition, they can be operated for extended periods without requiring re-calibration. For these reasons. it is desirable to use optical fiber thermometers in environments such as the International Space Station. However, it has recently been shown that temperature readings are corrupted by emission from the fiber when extended portions of the probe are exposed to elevated temperatures. This paper will describe several ways in which the reading from a second fiber can be used to correct the corrupted temperature measurements. The accuracy and sensitivity to measurement uncertainty will be presented for each method.
High Resolution Thermometers (HRTs) based on SQUID detection of the magnetization of a paramagnetic salt or a metal alloy has been commonly used for sub-nano Kelvin temperature resolution in low temperature physics experiments. The main applications to date have been for temperature ranges near the lambda point of He-4 (2.177 K). These thermometers made use of materials such as Cu(NH4)2Br4 *2H2O, GdCl3, or PdFe. None of these materials are suitable for EXACT, which will explore the region of the He-3/He-4 tricritical point at 0.87 K. The experiment requirements and properties of several candidate paramagnetic materials will be presented, as well as preliminary test results.