Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Advancement of Commercial Intumescent Expanding Foams for Deactivation and Decommissioning in the Nuclear Sector - 20198

Florida International University (FIU), in collaboration with The Department of Energy's Office of Environmental Management (DOE-EM), Savannah River National Laboratory (SRNL), and sites across the Savannah River complex, have identified an operational requirement for a fixative technology that is intended to immobilize and/or isolate residual contamination within a 3-dimensional space. Fixation of radiological contamination can reduce worker risk and mitigate potentially hazardous conditions, however nearly every marketed contamination fixative has been found to be flammable; a significant concern in radiological facilities. Coupled with this, industry fixatives are normally used as a thin coating which can present problems when attempting to stabilize irregular geometry or areas that are difficult to access whilst ensuring full coverage. The technical evaluation and advancement of commercial-off-the-shelf (COTS) polyurethane foams has yielded a down-selected candidate that shows potential in meeting the requirements to support deactivation and decommissioning activities. Several performance criteria have been established and tested to progress the technology readiness level towards an active field demonstration (TRL-7). Such criteria include: mechanical failure limits, adhesive and cohesive properties, thermal/fire resilience, determining thermal behavior, ability to immobilize contamination, and a means of non-destructive evaluation of applications. The test scenario examined was targeted towards an application for decommissioning nuclear pipework, in which the down-selected polyurethane foam would act as a barrier to segregate pipework and mitigate the potential for release during cutting, packaging, and storage operations. Testing carried out at SRNL included: mechanical evaluation of tensile, compressive, and adhesion strength by dynamic mechanical analysis (DMA), as well as thermogravimetric analysis (TGA). FIU examined the foam's fixative properties by utilizing phosphorescent europium-dysprosium doped strontium aluminate powder to investigating the extent to which contamination can be immobilized. FIU has also exploited previous successes in the field of intumescent technologies to assess the down-selected foam's tolerance to an extreme fire scenario, while maintaining the ability to effectively mitigate a contamination release. Parallel to this, extensive thermal investigations were carried out to determine the upper boundary of anticipated heat generation during the curing process as heat generation has the potential to compromise rubber parts of contaminated enclosures. These investigations subsequently yielded a promising method for a non-destructive application evaluation by means of infrared thermography. Utilizing the high sensitivity of modern IR cameras, coupled with the heat generated during the curing process of the polyurethane foam, FIU has been exploring the concept of monitoring the external pipe surface for indications of an irregular or abnormal application, thus informing operational decision making. The testing carried out utilized several current 'best fit' ASTM standards, which serve as helpful guidelines for testing, however, a precise definition of the operational parameters and requirements is still necessary. With continued collaboration with SRNL, FIU aims refine said definitions and develop new standards by which this, and other decommissioning technologies, can be accredited by relevant standards based testing. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Infusible Thermoplastic Composites for Wind Turbine Blade Manufacturing: Fatigue Life of Thermoplastic Laminates under Ambient and Low-Temperature Conditions

Traditionally, thermoset resins such as polyesters (PE) and epoxies are used as the polymer matrix for construction of wind turbine blades. However, concern about their end-of-life treatment garners interest to use thermoplastics for increased recyclability. However, the high viscosity of molten thermoplastics inhibits their use in manufacturing wind turbine blades with injection or compression molding. A recently developed, infusible, reactive thermoplastic resin overcomes this technological barrier. Toward verifying that this recyclable resin is suitable for use in wind turbine blades, a dataset of R?=?0.1 and R?=?10 fatigue data for glass fiber-reinforced acrylic composites is provided and equal fatigue life to industry standard epoxy and unsaturated PE resin systems is demonstrated. Specifically, R?=?0.1 fatigue data for acrylic composites at room temperature and -30?degrees C for verification of low-temperature performance are tabulated. To elucidate failure mechanisms, in situ mechanical testing with X-ray computed tomography demonstrates that damage accumulation occurs by crack propagation along the fiber-matrix interface under cyclic loading. Infrared (IR) thermography predicts failure points in composites specimens with porosity defects introduced from nonideal manufacturing processes. Furthermore, these manufacturing defects are shown to compromise the fatigue life of the acrylic laminates by an order of magnitude.

effect of defects↗

Spatiotemporal Thermal Coupling in VO 2 Device Arrays

Correlated oxides such as VO 2 exhibit an electrically driven insulator–metal transition (IMT) that underlies their promise for neuromorphic and memory devices. Yet the IMT is not a uniform bulk process but a spatiotemporal phenomenon in which local heating nucleates filaments, contracts or dissolves them with the electric field, and couples to the environment. In this work, we directly image the VO 2 IMT dynamics by mid-wave infrared, thermography synchronized with electrical transport, resolving device temperature with micrometer spatial and microsecond temporal resolution. At the single-device level, we capture the full cycle of filament nucleation, contraction, and relaxation during current/voltage-driven resistive switching. At the array level, we show that heat propagates across etched gaps with an effective length scale of ∼131 µm, enabling cooperative behaviors among electrically isolated devices. Short-range distanced devices exhibit mutual filament attraction and sequential dissolution, while long-range distanced devices differentiate into distinct roles: drivers that initiate switching, cooperative responders that undergo assisted self-oscillations, and passive reporters that record the thermal field. Furthermore, these results reframe thermal crosstalk, long regarded as parasitic, as an intrinsic coupling channel and design principle for organizing collective switching behaviors, with direct implications for emergent circuit functionality in neuromorphic and unconventional computing architectures.

coupling↗

Infrared Optical Anisotropy in Quasi‐1D Hexagonal Chalcogenide BaTiSe 3

Polarimetric infrared (IR) detection bolsters IR thermography by leveraging the polarization of light. Optical anisotropy, i.e., birefringence and dichroism, can be leveraged to achieve polarimetric detection. Recently, giant optical anisotropy is discovered in quasi-1D narrow-bandgap hexagonal perovskite sulfides, A 1+x TiS 3 , specifically BaTiS 3 and Sr 9/8 TiS 3 . In these materials, the critical role of atomic-scale structure modulations in the unconventional electrical, optical, and thermal properties raises the broader question of the nature of other materials that belong to this family. To address this issue, for the first time, high-quality single crystals of a largely unexplored member of the A 1+x TiX 3 (X = S, Se) family, BaTiSe 3 are synthesized. Single-crystal X-ray diffraction determined the room-temperature structure with the P31c space group, which is a superstructure of the earlier reported P6 3 /mmc structure. The crystal structure of BaTiSe 3 features antiparallel c-axis displacements similar to but of lower symmetry than BaTiS 3 , verified by the polarization dependent Raman spectroscopy. Fourier transform infrared (FTIR) spectroscopy is used to characterize the optical anisotropy of BaTiSe 3 , whose refractive index along the ordinary (E ⊥ c) and extraordinary (E ‖ c) optical axes is quantitatively determined by combining ellipsometry studies with FTIR. With a giant birefringence Δn ∼ 0.9, BaTiSe 3 emerges as a new candidate for miniaturized birefringent optics for mid-wave infrared to long-wave infrared imaging.

optical anisotropy↗

Morphophysiological Plant Phenotyping for the Development of Plant Breeding Under Drought and Heat Conditions: A Practical Approach

ABSTRACT Currently, the breeding programs focus their efforts on identifying and developing tolerant genotypes to adverse conditions, such as drought and high temperatures. In this context, the physiological approach, which involves phenotyping several traits, is useful for breeding programs. Leaf photosynthetic traits have become one of the main objectives to be evaluated for breeders due to their relationship with improving grain yield and biomass production. Gas exchange ( Ge ) and chlorophyll “a” fluorescence ( Chf ) are the main tools to characterize the photosynthetic activity in real time at the leaf level. Consequently, several association studies using proximal and nonproximal sensing (e.g., RGB, thermography) have been developed. However, for the correct application of this breeding approach, it is essential to have a basic knowledge of both the physiological principles involved in the readings and the limitations of phenotyping due to the characteristics of the devices available on the market. This revision also covers other traits, such as the morphological and anatomical characteristics of leaves and roots, and the use of isotopes complementing Ge and Chf measurements.

Estrada, Félix [Instituto de Investigaciones Agrop↗

Failure analysis of field-failed bypass diodes

Defective bypass diodes are often found as the largest factor leading to power loss in solar modules. Here, we report on failure mechanisms by investigating shunted bypass diodes from a rooftop installation, using a combination of multiple characterizations including current–voltage analysis, thermal-runaway testing, X-ray computed tomography, lock-in thermography, focused ion-beam cross-section imaging, chemical decapsulation, optical microscopy, and scanning electron microscopy with energy-dispersive X-ray spectroscopy. Differing from static discharge typically associated with lightning strikes on modules, we found diode failure by the mechanism of thermal damage under continuous, long-term overstress in forward bias. Our conclusion is based on evidence of energy dissipated—the small to medium extent of melt-through on the Schottky diode face. The diode failure shows distortions or roughening of the Schottky diode metal-semiconductor interface with the die attach, and some failures are accompanied by die-attach solder melting. We propose that nonuniform irradiance on the modules caused diode shunting due to extended periods of heat dissipation in the modules, because modules in this string were placed in two different orientations. In contrast, a second parallel module string of the same module type on the same rooftop with a unique plane of array did not show any diode failures. The thermal damage failure of melt-through was caused by the long-term current generated by overstressing of diodes that may have had crystalline and impurity defects.

14 SOLAR ENERGY↗

What Can Plastic Flow Fields Tell Us About Heat Sources in Deformation Processing?

We characterize primary (shape-change) and secondary (friction) deformation, and associated temperature fields, in metal cutting and forming processes, using in situ imaging and simulation. The experimental configurations enable access to the deformation zones and die contact-interfaces, for measuring deformation, temperature, and frictional drag. Infra-red thermography reveals that the plastic strain-rate field is an excellent proxy for the deformation-induced heat sources. Both spatially confined and diffuse strain-rate fields occur, depending on the initial workpiece deformation state. When the strain rate is confined, as in pre-hardened material, the temperature modeling is much simplified, as the heat source is also now localized. However complex, microstructure-driven deformation modes, like sinuous flow in annealed metals, result in spatially diffuse strain-rate and body heat sources, more challenging to analyze. Furthermore, our unified measurements should be of value for accurately estimating the fraction of plastic dissipation that is converted into heat in large-strain deformation processes.

36 MATERIALS SCIENCE↗

Large-scale additive manufacturing of self-heating molds

Large-scale material extrusion additive manufacturing technology is becoming the new mainstream technology for scaled-up composite mold and die applications. This paradigm shift in composite processing technology is primarily driven by out-of-autoclave tooling applications, in which fiber reinforced composite molds with scaled-up sizes and embedded heating elements are attractive. The present research describes the design, manufacturing, and testing of self-heating composite molds fabricated via a large-scale pellet extrusion 3D printing machine with an integrated wire co-extrusion tool. Polycarbonate (PC) composites reinforced with carbon fiber (PC/CF; 20 wt.%) and glass fiber (PC/GF; 20 wt.%) were used to fabricate mold parts. Joule heating thermal test results showed that uniform temperatures (~100 °C) were achieved for both PC/CF and PC/GF mold surfaces, using a custom-made feedback control power supply and infrared thermography. Mechanical characterizations, including tensile and flexural testing were performed on the wire-embedded and un-wired PC/CF and PC/GF base specimens to investigate the impact of the fiber reinforcement as well as the embedded wires. In the direction of extrusion, the ultimate tensile stress of PC/CF was 105 MPa, and that of PC/GF was 73 MPa, while the neat PC value was 64 MPa. Inner-bead voids and interfacial gaps were observed and characterized via optical and scanning electron microscopy. The embedded wires and inner bead impacted the mechanical properties of the composites. Furthermore, the stiffness of the wire-embedded mold was still satisfactory, proving that the technology can be used to fabricate additively manufactured out-of-oven/autoclave molds.

36 MATERIALS SCIENCE↗

Capsule network-based semantic segmentation model for thermal anomaly identification on building envelopes

Thermography technology is widely used to inspect thermal anomalies in building façade systems. Computer vision-based techniques provide opportunities to autonomously detect such heat anomalies to significantly improve the efficiency of decision-making for building envelope retrofitting and maintenance. Here, in this work, we propose a novel Capsule Network-based deep learning model – CapsLab – that detects and identifies thermal anomalies by semantic segmentation. CapsLab is built based on our proposed prediction-tuning capsule (PT-Capsule) layer. Different from a traditional capsule layer, which consists of part-whole transformation and capsule-routing process, the proposed layer is composed of a prediction and tuning process, which helps decreasing the number of model parameters significantly. While the applicability of traditional Capsule Networks (CapsNets) has been limited to simpler tasks and smaller datasets due to their scalability issue, we can leverage the lightweight of the proposed PT-Capsule layer, and apply it to the semantic segmentation task. In this work, we also employ our previously presented performance metric, referred to as the Anomaly Identification Metric (AIM) (Kakillioglua et al. 2021), to evaluate the segmentation outputs. Traditional performance metrics do not accurately reflect the true performance of the segmentation models in thermal anomaly identification due to the high subjectivity in the annotation process and higher overlap ratio sensitivity of the standard metrics. AIM, on the other hand, is robust to these drawbacks. Experimental results show, both qualitatively and quantitatively, that our proposed segmentation method can effectively segment the thermal anomalies. Specifically, our model provides 9.38% and 13.53% improvements over the baseline model – DeepLabV3+ – based on traditional mIoU score and the AIM score, respectively, while requiring less model parameters and less computation at the same time. In addition, the scores that the AIM metric generates better align with the scores provided by building performance experts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhanced through-thickness electrical conductivity and lightning strike damage response of interleaved vertically aligned short carbon fiber composites

Through-thickness electrical conductivity of carbon fiber reinforced polymers (CFRPs) is a key characteristic that determines the severity of lighting strike-induced damage. Carbon Fibers (CFs) are inherently electrically conductive and therefore provide high conductivity in the direction of the fiber orientation. However, electrical conductivities through the thickness and orthogonal to the CF orientation in CFRPs are governed by the insulating polymer matrix present between CFs. Here, in this work, through the thickness alignment of short CFs in between layers of CFRP laminates is demonstrated to improve the through-thickness electrical conductivity. Composites with interleaved vertically aligned short CF fibers (<150 μm) will be referred as V-fiber composites hereafter. The effect of the V-fiber on the lightning strike damage is evaluated against an artificial lightning strike of 100 kA (modified waveform A of SAE ARP-5412B standard). The improved through-thickness electrical conductivity of CFRP laminates (1.15 S/cm) through vertical alignment of short CFs was compared to reference CFRP laminates (0.13 S/cm) and was found to dissipate the artificial lightning strike current more efficiently. The surface damage after the artificial lightning strike in the V-fiber composites was reduced to 12.69 cm 2 compared to the reference CFRP surface damage of 57.67 cm 2 , a 78% reduction. It was also demonstrated that Joule heat generated due to lightning strike on the composites was significantly less than the reference sample using infrared (IR) thermography. A high retention (up to 78%) of flexural properties (modulus and strength) was observed in V-fiber composites post lightning strike impact as compared to only 47% retention in the reference panel.

42 ENGINEERING↗

Internal arcing and lightning strike damage in short carbon fiber reinforced thermoplastic composites

Short carbon fiber reinforced thermoplastic composites (S-CFRTP) are currently used in interior parts of aircraft such as electronic circuitry and assemblies, and their usage in aircraft's exterior is also being studied. In this paper, we present a lightning strike study on S-CFRTPs. High performance thermoplastics such as a polyphenylene sulfide (PPS) reinforced with 50% weight (wt.) short carbon fiber (CF), a polyphenyl sulfone (PPSU) reinforced with 25 % wt. Short CF and a acrylonitrile butadiene styrene (ABS) with 20 % wt. short CF were tested against artificial lightning strikes. All samples were prepared using an extrusion compression molding (ECM) technique. A modified component A (100 kA) of lightning waveform, as defined by SAE ARP 5412-B, was applied. High speed imaging, thermography, scanning electron microscopy (SEM) and ultrasonic non-destructive evaluation were performed to understand the effect of lightning strikes on the thermoplastic panels. The results show that electrical conductivity of the composite, thermal stability of the polymers, and CF orientation significantly affected the damage from artificial lightning strikes. PPS composite had the highest resilience against lightning strike damage, retaining 95% and 89% residual flexural strength and modulus, respectively. CF exfoliation due to internal arcing was observed in the carbon fiber-reinforced ABS polymer (CF-ABS) composite. CF exfoliation damage has been reported for the first time.

36 MATERIALS SCIENCE↗

A scoping review of non-destructive testing (NDT) techniques in building performance diagnostic inspections

Understanding building envelope thermodynamics is an essential foundation of building sciences, mainly due to the envelope’s role as a boundary layer for exterior environments, as well as a container and regulator of internal microclimates. This paper presents a scoping literature review of select Non-destructive Testing (NDT) techniques for building envelope scanning and surveying for thermodynamic diagnostics. The investigation focuses specifically on reviewing six NDT techniques: Ground Penetrating Radar (GPR), Light Detection and Ranging (LiDAR)/Laser Scanning, Thermography, Ultrasound, Close-Range Photogrammetry and Through Wall Imaging Radar (TWIR). The aim is to identify knowledge gaps in terms of their use in accurately characterizing envelope compositions for further integration in Building Energy Modeling (BEM). Each technique was evaluated according to set categories imbibed from the American Society of Heating, Refrigerating, and Air Conditioning Engineering (ASHRAE) Standard 211P that showcase the technique’s ability to extract various relevant information. A framework is then developed to inform users on how to use hybrid NDT-based workflows applied in building envelope energy audits. The study concludes by discussing possibilities of utilizing NDT in large-scale audit automation, BEM integration, and developing built environment policies focusing on increasing existing building performance through retrofitting design.

36 MATERIALS SCIENCE↗

Thermal property characterization of phase change materials in building applications: A systematic review of fundamentals, recent progress, and future directions

Phase change materials (PCMs) can reduce building peak loads and enable demand-responsive thermal energy storage (TES), but their deployment depends on reliable measurement and interpretation of thermal properties across laboratory, intermediate, and application scales. Here, this review systematically examines characterization methods, testing protocols, and recent advances for neat PCMs and PCM composites, emphasizing thermal conductivity, enthalpy-related properties (phase change temperature, latent heat, specific heat), and cycling stability. For thermal conductivity, we compare steady-state and transient techniques and note limitations when phase transition and contact resistance affect measurements. For enthalpy–temperature characterization, we discuss differential scanning calorimetry together with intermediate- and bulk-scale methods, including T-history, heat flow meter testing, and three-layer calorimetry (3LC), to generate application-relevant enthalpy–temperature profiles. Cycling stability is organized into four experimental families: thermoelectric–air, fully thermoelectric, water-bath, and in situ chamber approaches, with attention to separating reversible supercooling from true degradation such as phase segregation. We highlight emerging noncontact diagnostics, including infrared thermography and embedded sensing, for spatially resolved validation and multiscale interpretation. Finally, we review the growing use of AI and machine learning for property prediction, inverse characterization from experimental signals, and real-time state estimation in building-integrated TES. Key needs include harmonized protocols, interlaboratory benchmarking, uncertainty reporting, and metadata-rich datasets to accelerate reproducible PCM qualification for grid-flexible buildings.

AI↗

Preliminary proof-of-concept of real-time divertor heat flux control from infrared cameras with nitrogen injection in the DIII-D tokamak

In future tokamak reactors like ITER and the Fusion Pilot Plant (FPP), real-time feedback control of heat flux to the plasma-facing components (PFC) will be critical for steady-state operation. This work presents the first experimental demonstration of real-time divertor heat flux estimation with infrared thermography and feedback control with impurity seeding on the DIII-D tokamak. The flexible infrastructure of the Plasma Control System (PCS) on DIII-D makes this new capability possible. The PCS software runs on a gateway computer system, and five real-time compute nodes. An array of low latency streaming digitizers from D-TACQ Solutions connects to these real-time computers to collect and process data, and send commands to actuators during plasma discharges. This system handles the signal IO from the tokamak and allows the PCS to utilize the diagnostic data necessary to perform control in real-time. Feedback control on heat flux was accomplished by feeding infrared camera data from the “Infrared TV” (IRTV) camera to a custom-developed User Datagram Protocol (UDP) server. This server transmits infrared data to a newly developed PCS algorithm that estimates the heat flux to PFC. Here, a proportional integral derivative (PID) controller minimizes the error between a heat flux reference and the real-time estimate by injecting nitrogen gas into the divertor.

Algorithm development↗

Visualization, understanding, and mitigation of process-induced-membrane irregularities in gas diffusion electrode-based polymer electrolyte membrane fuel cells

Polymer electrolyte membrane fuel cells (PEMFC) show substantial promise for their application in electric vehicles. For large-scale manufacturing of PEMFCs, roll-to-roll coated gas-diffusion-electrodes (GDE) offer certain advantages over other production pathways. Procedures including hot pressing and coating an ionomer overlayer may be necessary for this manufacturing pathway to enable a suitable catalyst layer/membrane interface. The same procedures may potentially introduce membrane irregularities, especially when thin membranes are used. Limited understanding exists regarding if and to what extent such irregularities impact PEMFC performance and lifetime, and therefore be considered defects. In this study, NREL's customized fuel cell hardware that enables quasi in-situ infrared (IR) thermography studies was utilized to visualize spatial hydrogen crossover and identify membrane irregularities that originated from the GDE-based MEA fabrication process. The structure of these membrane irregularities was investigated by scanning electron microscopy (SEM) and its impact on initial H2/air performance was determined. Accelerated stress testing (AST) revealed that these irregularities develop into failure point locations. These results were validated across many MEAs with identified process-induced membrane irregularities. By selecting specific gas diffusion media properties and by fine tuning the MEA hot pressing parameters, the formation of such membrane irregularities was mitigated.

08 HYDROGEN↗

Towards deep computer vision for in-line defect detection in polymer electrolyte membrane fuel cell materials

Polymer Electrolyte Membrane (PEM) fuel cells are a promising source of alternative energy. However, their production is limited by a lack of well-established methods for quality control of their constituent materials like the membrane-electrode assembly during roll-to-roll manufacturing. One potential solution is the implementation of deep learning methods to detect unwanted defects through their detection in scanned images. Here we explore the detection of defects like scratches, pinholes, and scuffs in a sample dataset of PEM optical images using two deep learning algorithms: Patch Distribution Modeling (PaDiM) for unsupervised anomaly detection and Faster-RCNN for supervised object detection. Both methods achieve scores on performance metrics (ROC-AUC and PRO-AUC for PaDiM and AP for Faster-RCNN) that are comparable to their scores on benchmark datasets. These methods also have the potential to detect a wider range of defects compared to IR thermography and previous optical inspection methods. Overall, deep learning shows promise at detecting relevant defects of interest and has the potential to achieve real-time defect detection.

30 DIRECT ENERGY CONVERSION↗

The impact of hot-press conditions on the durability of polymer electrolyte membrane fuel cells

The proton exchange membrane integrity can be compromised during hot-press fabrication of membrane electrode assemblies (MEAs) causing premature cell failures during operation. In this work, infrared (IR) thermography was used as a diagnostic tool to spatially visualize hydrogen (H 2 ) crossover and identify process-induced-membrane irregularities (PIMs). These irregularities were identified as seed locations for MEA failures. Fine tuning of hot-press conditions was used to mitigate premature cell failures informed by accelerated stress testing (AST). The impact of PIMs on the initial performance, high-frequency resistances, open-circuit voltage, and H 2 crossover are reported. Nafion XL and 212 membranes, hot-pressed with a force of 16 kg/cm 2 and temperature of 120°C, were found to be consistently irregularity-free. Irregularity-free MEAs using Nafion 211, 212, and XL membranes demonstrated AST lifetime improvements of 58, 64 and 400%, respectively, compared to those fabricated with non-optimized conditions. In conclusion, this work highlights the importance of fabrication parameters on premature cell failures.

08 HYDROGEN↗

Humidity sensitivity of large area silicon sensors: Study and implications

The production of large area sensors is one of the main challenges that the ATLAS collaboration faces for the new Inner-Tracker full-silicon detector. During the prototype fabrication phase for the High Luminosity Large Hadron Collider upgrade, several ATLAS institutes observed indications of humidity sensitivity of large area sensors, even at relative humidities well below the dew point. Specifically, prototype Barrel and End-Cap silicon strip sensors fabricated in 6-inch wafers manifest a prompt decrease of the breakdown voltage when operating under high relative humidity, adversely affecting the performance of the sensors. In addition to the investigation of these prototype sensors, a specific fabrication batch with special passivation is also studied, allowing for a deeper understanding of the responsible mechanisms. Here we present an extensive study of this behaviour on large area sensors. The locations of the hotspots at the breakdown voltage at high humidity are revealed using different infrared thermography techniques. Several palliative treatments are attempted, proving the influence of sensor cleaning methods, as well as baking, on the device performance, but no improvement on the humidity sensitivity was achieved. Furthermore, a study of the incidence of the sensitivity in different batches is also presented, introducing a hypothesis of the origins of the humidity sensitivity associated to the sensor edge design, together with passivation thickness and conformity. Several actions to be taken during sensor production and assembly are extracted from this study, in order to minimize the impact of humidity sensitivity on the performance of large area silicon sensors for High Energy Physics experiments.

47 OTHER INSTRUMENTATION↗