Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal response functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

PID-Regulated Heating System for PIP-II Reference Line

The Proton Improvement Project-2 centers on building a new superconducting linear particle accelerator (Linac) at Fermilab. At the heart of the accelerator is the reference line, a critical system that defines the ideal path for the particle beam as it passes through magnets, RF cavities, and other beamline elements. Temperature stability is crucial for the reliable operation of RF components, such as mixers and filters. Fluctuations affect key performance parameters like conversion loss, isolation, and linearity. To mitigate any drift caused by ambient temperature changes, a heating plate assembly is utilized to maintain key components at a controlled temperature of 40°C. The system utilizes an aluminum 36”x36”x0.5” heat plate powered by a MOSFET-based control circuit, delivering approximately 460 W of thermal energy through a resistor array. Real-time temperature feedback is provided by a PT100 Resistance Temperature Detector (RTD), which interfaces with a Proportional–Integral–Derivative (PID) control algorithm to maintain closed-loop temperature regulation. The control signal actively modulates the gate voltage of an N channel MOSFET, dynamically adjusting power delivery in response to deviations from the temperature setpoint. Simulations and LTspice models validate the functionality and responsiveness of the circuit under varying conditions. The prototype has successfully demonstrated stable thermal control, paving the way for integration into the PIP-II infrastructure. The final design will feature an expanded resistor array, as well as communication with a PLC for continuous data acquisition and diagnostics. This work directly supports Fermilab’s broader mission by contributing to the stability and reliability of core accelerator systems, enhancing the precision of particle beam delivery for future physics experiments.

Mosher, Alexander [Fermilab]↗

Response of thermal ions to electromagnetic ion cyclotron waves

Electromagnetic ion cyclotron waves generated by 10 - 50 keV protons in the Earth's equatorial magnetosphere will interact with the ambient low-energy ions also found in this region. We examine H(+) and He(+) distribution functions from approx. equals 1 to 160 eV using the Hot Plasma Composition Experiment instrument on AMPTE/CCE to investigate the thermal ion response to the waves. A total of 48 intervals were chosen on the basis of electromagnetic ion cyclotron (EMIC) wave activity: 24 with prevalent EMIC waves and 24 with no EMIC waves observed on the orbit. There is a close correlation between EMIC waves and perpendicular heated ion distributions. For protons the perpendicular temperature increase is modest, about 5 eV, and is always observed at 90 deg pitch angles. This is consistent with a nonresonant interaction near the equator. By contrast, He(+) temperatures during EMIC wave events averaged 35 eV and sometimes exceeded 100 eV, indicating stronger interaction with the waves. Furthermore, heated He(+) ions have X-type distributions with maximum fluxes occurring at pitch angles intermediate between field-aligned and perpendicular directions. The X-type He(+) distributions are consistent with a gyroresonant interaction off the equator. The concentration of He(+) relative to H(+) is found to correlate with EMIC wave activity, but it is suggested that the preferential heating of He(+) accounts for the apparent increase in relative He(+) concentration by increasing the proportion of He(+) detected by the ion instrument.

Anderson, B. J.↗

Characterization of Composite Damage Using Passive Thermography

Passive thermography is used to monitor small increases in temperature on a composite structure during loading. A rise in temperature can be attributed to damage formation due to matrix cracking and fiber breaks. An infrared camera allows for imaging the damage location, size, and shape. Recently, a technique has been developed to estimate the depth of the damage in a composite hat-stiffened panel during quasi-static loading. This technique is based on two heat generation components. The first component is an instantaneous thermoelastic response due to a strain release. The second component is mechanical heating, at the interface of failure, due to fracture damage. This second component produces a transient rise in temperature that is a function of the damage depth and thermal diffusivity. The first component defines the thermal start time for the transient response. A one-dimensional thermal model is used to determine the damage depth for a known thermal diffusivity. The results are compared to ultrasonic and X-ray CT data and show good agreement for damage depth.

Thermal nondestructive evaluation↗

Environmental loading effects on structures

The environment in which a structure vibrates influences its modal characteristics. Presented herein is experimental modal survey test results on splitter vanes under liquid nitrogen mass-pressure-thermal loading. In particular, shifts in modal frequencies are studied via frequency response functions, power spectral densities, isoplots, quadrature or imaginary plots, and vibration mode shape characteristics generated from strain and acceleration measurements. Analyses have shown that while mass loading lowers the frequencies, increased pressure and lower temperature have opposite effect. Thus, pressurization and cooling of a liquid causes the modal frequencies of the structure in which it is contained to shift upward.

Panossian, H. V.↗

A case study demonstration of the soil temperature extrema recovery rates after precipitation cooling at 10-cm soil depth

Since the invention of maximum and minimum thermometers in the 18th century, diurnal temperature extrema have been taken for air worldwide. At some stations, these extrema temperatures were collected at various soil depths also, and the behavior of these temperatures at a 10-cm depth at the Tifton Experimental Station in Georgia is presented. After a precipitation cooling event, the diurnal temperature maxima drop to a minimum value and then start a recovery to higher values (similar to thermal inertia). This recovery represents a measure of response to heating as a function of soil moisture and soil property. Eight different curves were fitted to a wide variety of data sets for different stations and years, and both power and exponential curves were fitted to a wide variety of data sets for different stations and years. Both power and exponential curve fits were consistently found to be statistically accurate least-square fit representations of the raw data recovery values. The predictive procedures used here were multivariate regression analyses, which are applicable to soils at a variety of depths besides the 10-cm depth presented.

Welker, Jean Edward↗

Structural design of the Large Deployable Reflector (LDR)

An integrated Large Deployable Reflector (LDR) analysis model was developed to enable studies of system responses to the mechanical and thermal disturbances anticipated during on-orbit operations. Functional requirements of the major subsystems of the LDR are investigated, design trades are conducted, and design options are proposed. System mass and inertia properties are computed in order to estimate environmental disturbances, and in the sizing of control system hardware. Scaled system characteristics are derived for use in evaluating launch capabilities and achievable orbits. It is concluded that a completely passive 20-m primary appears feasible for the LDR from the standpoint of both mechanical vibration and thermal distortions.

Satter, Celeste M.↗

MODIS Thermal Emissive Bands Calibration Improvements for Collection 7

The MODIS thermal emissive bands (TEB) radiometric calibration uses a quadratic function for the instrument response, and the calibration coefficients look-up tables (LUTs) are updated using the response of an on-board blackbody (BB). After more than 21 and 19 years on-orbit, the TEB performances for Terra and Aqua MODIS have been generally stable. However, contamination from electronic crosstalk, a known issue since prelaunch, has affected the L1B image quality and measurement accuracy. In addition to the photovoltaic (PV) longwave infrared (LWIR) bands crosstalk correction included in Terra MODIS Collection 6.1 (C6.1), a crosstalk correction for select detectors in the Terra and Aqua mid-wave infrared (MWIR) and Aqua PV LWIR bands are applied in C7. The mission-long crosstalk coefficients for the selected detectors are derived and populated in the form of LUTs. The crosstalk correction is applied to both on-orbit calibration and the algorithm used to generate Earth-view L1B products. Among these detectors, the Aqua MODIS band 24 detector 1 crosstalk has the largest impact on image quality, with striping observed over cold scenes for both Terra and Aqua MODIS. The images of C7 L1B and C6.1 are compared to assess the impact of the correction. Additional assessments using Earthview measurements and inter-comparison also revealed the need for improvement of calibration stability and consistence for select bands. Additional improvements for long-term stability and mirror side consistence were developed using quasideep convective clouds (qDCC), Dome-C, ocean, desert, and inter-comparison with other instruments.

MODIS↗

Entropy generation method to quantify thermal comfort

The present paper presents a thermodynamic approach to assess the quality of human-thermal environment interaction and quantify thermal comfort. The approach involves development of entropy generation term by applying second law of thermodynamics to the combined human-environment system. The entropy generation term combines both human thermal physiological responses and thermal environmental variables to provide an objective measure of thermal comfort. The original concepts and definitions form the basis for establishing the mathematical relationship between thermal comfort and entropy generation term. As a result of logic and deterministic approach, an Objective Thermal Comfort Index (OTCI) is defined and established as a function of entropy generation. In order to verify the entropy-based thermal comfort model, human thermal physiological responses due to changes in ambient conditions are simulated using a well established and validated human thermal model developed at the Institute of Environmental Research of Kansas State University (KSU). The finite element based KSU human thermal computer model is being utilized as a "Computational Environmental Chamber" to conduct series of simulations to examine the human thermal responses to different environmental conditions. The output from the simulation, which include human thermal responses and input data consisting of environmental conditions are fed into the thermal comfort model. Continuous monitoring of thermal comfort in comfortable and extreme environmental conditions is demonstrated. The Objective Thermal Comfort values obtained from the entropy-based model are validated against regression based Predicted Mean Vote (PMV) values. Using the corresponding air temperatures and vapor pressures that were used in the computer simulation in the regression equation generates the PMV values. The preliminary results indicate that the OTCI and PMV values correlate well under ideal conditions. However, an experimental study is needed in the future to fully establish the validity of the OTCI formula and the model. One of the practical applications of this index is that could it be integrated in thermal control systems to develop human-centered environmental control systems for potential use in aircraft, mass transit vehicles, intelligent building systems, and space vehicles.

Models, Biological↗

Microwave conductivity of laser ablated YBaCuO superconducting films and its relation to microstrip transmission line

The discovery of high temperature superconductor oxides has raised the possibility of a new class of millimeter and microwave devices operating at temperatures considerably higher than liquid helium temperatures. Therefore, materials properties such as conductivity, current density, and sheet resistance as a function of temperature and frequency, possible anisotropies, moisture absorption, thermal expansion, and others, have to be well characterized and understood. The millimeter wave response was studied of laser ablated YBa2Cu3O(7-x)/LaAlO3 thin films as a function of temperature and frequency. In particular, the evaluation of their microwave conductivity was emphasized, since knowledge of this parameter provides a basis for the derivation of other relevant properties of these superconducting oxides, and for using them in the fabrication of actual passive circuits. The microwave conductivity for these films was measured at frequencies from 26.5 to 40.0 GHz, in the temperature range from 20 to 300 K. The values of the conductivity are obtained from the millimeter wave power transmitted through the films, using a two fluid model.

Bhasin, K. B.↗

Microwave conductivity of laser ablated YBa2Cu3O(7-delta) superconducting films and its relation to microstrip transmission line performance

The discovery of high temperature superconductor oxides has raised the possibility of a new class of millimeter and microwave devices operating at temperatures considerably higher than liquid helium temperatures. Therefore, materials properties such as conductivity, current density, and sheet resistance as a function of temperature and frequency, possible anisotropies, moisture absorption, thermal expansion, and others, have to be well characterized and understood. The millimeter wave response of laser ablated YBa2Cu3O(7-delta)/LaAlO3 thin films was studied as a function of temperature and frequency. In particular, the evaluation of their microwave conductivity was emphasized, since knowledge of this parameter provides a basis for the derivation of other relevant properties of these superconducting oxides, and for using them in the fabrication of actual passive circuits. The microwave conductivity for these films was measured at frequencies from 26.5 to 40.0 GHz, in the temperature range from 20 to 300 K. The values of the conductivity are obtained from the millimeter wave power transmitted through the films, using a two fluid model.

Bhasin, K. B.↗

Estimation of Delamination Crack Depth Using Passive Thermography

Passive thermography is used to monitor small increases in temperature resulting from delamination damage formation in a composite hat-stiffened panel during quasi-static loading. The heating is composed of two heat generation components. The first component is an instantaneous response due to a strain release during quasi-static loading. The second component is mechanical heating, at the interface of failure, due to fracture damage. This second component produces a transient rise in temperature that is a function of the damage depth and thermal diffusivity. The first component defines the thermal start time for the transient response. A one-dimensional thermal model is used to determine the damage depth. The results are compared to ultrasonic and X-ray CT data. The advantages and limitations of the thermal technique for damage depth detection are discussed.

Zalameda, Joseph N.↗

Autonomous Strategies for Improved Performance and Reliability of Li‐Ion Batteries

Abstract The battery community has devoted significant effort to improve the performance and reliability of Li‐ion batteries through the development of new materials. The integration of autonomous function provides an alternative strategy to further extend performance. Autonomous material systems mimic the ability of biological systems to self‐protect, sense, regulate, and heal in response to damage and other environmental changes. When incorporated in batteries, these materials enable autonomic restoration of battery performance upon degradation, as well as autonomic shutdown or extinguishment in response to thermal runaway. Successful strategies for improving Li‐ion battery performance include controlled release of microencapsulated functional additives and the integration of self‐healing or adaptive interlayers and binders. These methods have been effective for stabilizing the solid electrolyte interface, preventing battery fires, restoring electrode conductivity, and suppressing Li dendrite growth. Challenges and opportunities exist in the further application of autonomous strategies in the battery environment. A greater variety of encapsulated additives with precise triggered‐release are needed to address specific battery degradation mechanisms. Incorporation of self‐healing polymers in solid‐state batteries facilitates improvement in interfacial and mechanical stability. The integration of autonomous strategies with battery management systems potentially enables enhanced control over multiple battery cycling parameters.

Zhao, Lihong↗

Radial–axial transport coordination enhances sugar translocation in the phloem vasculature of plants

Abstract Understanding mass transport of photosynthates in the phloem of plants is necessary for predicting plant carbon allocation, productivity, and responses to water and thermal stress. Several hypotheses about optimization of phloem structure and function and limitations of phloem transport under drought have been proposed and tested with models and anatomical data. However, the true impact of radial water exchange of phloem conduits with their surroundings on mass transport of photosynthates has not been addressed. Here, the physics of the Munch mechanism of sugar transport is re-evaluated to include local variations in viscosity resulting from the radial water exchange in two dimensions (axial and radial) using transient flow simulations. Model results show an increase in radial water exchange due to a decrease in sap viscosity leading to increased sugar front speed and axial mass transport across a wide range of phloem conduit lengths. This increase is around 40% for active loaders (e.g. crops) and around 20% for passive loaders (e.g. trees). Thus, sugar transport operates more efficiently than predicted by previous models that ignore these two effects. A faster front speed leads to higher phloem resiliency under drought because more sugar can be transported with a smaller pressure gradient.

58 GEOSCIENCES↗

Research study of pressure instrumentation

To obtain a more vibration resistant pressure sensor for use on the Space Shuttle Main Engine, a proximity probe based, diaphragm type pressure sensor breadboard was developed. A fiber optic proximity probe was selected as the sensor. In combination with existing electronics, a thermal stability evaluation of the entire probe system was made. Based upon the results, a breadboard design of the pressure sensor and electronics was made and fabricated. A brief series of functional experiments was made with the breadboard to calibrate, thermally compensate, and linearize its response. In these experiments, the performance obtained in the temperature range of -320 F (liquid N2) to +200 F was comparable to that of the strain gage based sensor presently in use on the engine. In tests at NASA-Marshall Space Flight Center (MSFC), after some time at or near liquid nitrogen temperatures, the sensor output varied over the entire output range. These large spurious signals were attributed to condensation of air in the sensing gap. In the next phase of development of this sensor, an evaluation of fabrication techniques toward greater thermal and mechanical stability of the fiber probe assembly must be made. In addition to this, a positive optics to metal seal must be developed to withstand the pressure that would result from a diaphragm failure.

Hoogenboom, L.↗

Multi-wavelength Observations and Modelling of a Solar Flare

Aims: The aim of this work is to investigate the dynamic behavior of a C-class solar flare through the evolution of temperature, emission measure, energy loss and velocity. In particular, the variation of these properties with time are studied using multi-wavelength observations in combination with a recently developed 0-D hydrodynamic model. Methods: The temperature and emission measure evolution were studied using several instruments covering a wide range of temperatures - the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI, >5 MK), GOES-12 (5- 30 MK), the Transition Region and Coronal Explorer (TRACE 171 A, 1 MK) and the Coronal Diagnostic Spectrometer (CDS, 0.03-8 MK). The temperature and emission measure were analysed through the systematic cooling of flare plasma through the response functions of these instruments. These parameters were then investigated using the Enthalpy Based Thermal Evolution of Loops model (EBTEL). The Doppler shifts at both flare footpoints were analysed using five emission lines seen by CDS. Results: The flare began with clear evidence for pre-flare heating. Upflows of approx.90 km/s and low level emission, both observed in Fe XIX before the main impulsive phase were explained by pre-flare gentle chromospheric evaporation. During the main impulsive phase, the flare plasma was heated to a temperature of >13 MK in approximately 10 minutes. Explosive chromospheric evaporation was observed, driving upflows of approx.80 km/s in Fe XIX and simultaneous downflows of approx.20 km/s in He I and O v. At the peak of the Rare, conduction modelled by EBTEL was found to be the dominant loss mechanism, working efficiently to both lower the temperatures and drive gentle chromospheric evaporation. As the temperature fell below approx.8 MK, radiation became the dominant loss mechanism. During the final stages of the decay phase, downflowing plasma was observed at the footpoints in He I, O v and Mg x at velocities of up to approx.40 km/s, suggesting loop draining occurred. Conclusions. This is the first extensive study of the evolution of flare plasma using both spectroscopic and broad-band instruments in conjunction with a comprehensive hydrodynamic model. The flare began with pre-flare heating and then evolved following the predictions of the standard flare model. Detailed analysis of the plasma heating mechanisms was carried out and the heating function most consistent with observations was found to be Gaussian in shape. The simulations suggested that both direct heating and heating by a non-thermal beam played significant roles in this event.

Raftery, Claire L.↗

Effect of Sample Mass, Confinement, and Preheating Time on the Thermal Response of LLM‐105: Experiments and Kinetic Analysis

Various small-scale experiments were performed to provide data for developing a model to predict the thermal response of LLM-105 over a wide range of conditions. The thermal decomposition of LLM-105 was studied as a function of sample mass, confinement of volatile products, and preheating time in both isothermal and ramped heating experiments. The thermal decomposition of LLM-105 is a two-step process, as shown by the two exothermic peaks in the heat flow profiles, which were fitted to two nth-order autocatalytic reaction models with a similar activation energy of ∼289 kJ/mol. The magnitude and shape of these peaks varied with sample mass and confinement. Increasing sample mass enhanced the second exotherm with respect to the first one, while increasing the level of confinement promoted a transition from a sublimation-dominated regime towards thermal decomposition. The effect of LLM-105 particle size on the rate of weight loss was evident for open-pan experiments, where bigger particles sublimed at lower temperatures than smaller particles. Thermal response and solid residue composition of LLM-105 samples were analyzed following preheating for different durations. Longer preheating times caused a shift of the second exotherm to lower temperatures and a decrease in the reaction enthalpy, confirming that LLM-105 decay is a consecutive reaction mechanism, probably autocatalytic. In conclusion, the kinetic model derived from ramped experiments was validated against the measured LLM-105 fraction remaining and the enthalpy remaining of the solid residue as a function of preheating times and showed good agreement.

Chemistry - Chemical explosives↗

Analysis of velocity-coupled response function data from the dual rotating valve

The results of a re-evaluation of the propellant combustion data obtained using the dual valve approach for measuring velocity-coupling characteristics of solid propellants are presented. Data analysis and testing procedures are described. The velocity response is compared to pressure-coupled response data within the context of thermal wave response theory. This comparison shows important inconsistencies which cast doubt on inferring the velocity response from pressure-coupled response functions.

Brown, R. S.↗

Probing Supercritical Phase Transition using Ultrafast X-ray Diagnostics (Final Technical Report)

Over recent years, several hypotheses have been put forward to elucidate supercritical transition states. Despite significant progress on the fundamental understanding of fluids at these supercritical conditions, important questions concerning the microstructure and dynamical processes remain. A particular research issue is hereby the fundamental understanding of the morphology of the molecular microstructure and its effect on the macroscopic behaviour and thermodynamic response functions. It is widely believed that the supercritical state is homogeneous without structural and dynamic observables to distinguish between a liquid and a vapor. However, recent investigations have identified regions of distinct liquid-like or vapor-like properties even under supercritical conditions. Specifically, it was shown that the transition between liquid-like and vapor-like states occurs across an extension to the coexistence line, marked by almost discontinuous changes in fluid properties. This transition was first identified experimentally by Nishikawa and Tanaka and stands in contrast to the classical presentation of the supercritical state space as a featureless, homogeneous domain. Structurally, the most important properties of supercritical fluids are the dynamic heterogeneities and local density fluctuations that are present within the fluid state at the microscopic level. These inhomogeneities are associated with the formation of molecular clusters of various sizes with liquid-like properties separated by voids of unbound gas-phase molecules which continuously restructure itself at picosecond timescales. By utilizing ultrafast X-ray Photon Correlation Spectroscopy (XPCS) at the Linac Coherent Light Source (LCLS) and X-ray synchrotron measurements as an experimental probe of these structural changes at the molecular level we seek to elucidate the higher-order phase transition from a liquid-like to a vapor-like state in the region extending the critical point. Open questions we seek to address particularly with XPCS are: (i) the underlying mechanisms responsible for the density fluctuations at supercritical conditions and how these dynamical processes at the molecular level affect the thermodynamic response functions and (ii) on what timescales do dynamical processes evolve that are associated with thermalization, molecular diffusion, and intermolecular cluster transfer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗