Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal infrared”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Analysis of effective radiant temperatures in a Pacific Northwest forest using Thermal Infrared Multispectral Scanner data

Analysis of Thermal Infrared Multispectral Scanner data collected over H. J. Andrews experimental forest in western Oregon indicated that aspect and slope gradient had a greater effect on the thermal emission of younger reforested clearcuts than of older stands. Older forest stands (older than 25 years) with greater amounts of green biomass and closed canopies, had lower effective radiant temperatures than younger, less dense stands. Aspect and slope had little effect on the effective radiant temperature of these older stands. Canopy temperature recorded at approximately 1:30 pm local time July 29, 1983 were nearly equal to maximum daily air temperature recorded at eight reference stands. The investigation provided some insights into the utility of the thermal sensor for detecting surface temperature differences related to forest composition and green biomass amounts in mountain terrain.

Sader, S. A.↗

Thermal Infrared Multispectral Scanner (TIMS): An investigator's guide to TIMS data

The Thermal Infrared Multispectral Scanner (TIMS) is a NASA aircraft scanner providing six channel spectral capability in the thermal infrared region of the electromagnetic spectrum. Operating in the atmospheric window region (8 to 12 micrometers) with a channel sensitivity of approximately 0.1 C, TIMS may be used whenever an accurate measure of the Earth's surface is needed. A description of this scanner is provided as well as a discussion of data acquisition and reduction.

Palluconi, F. D.↗

Thermal Infrared Geologic Remote Sensing Research at the Jet Propulsion Laboratory

Remotely sensed thermal infrared spectral data have great potential to improve rock type discrimination if the factors that control thermal infrared spectral reflection and emission can be better understood. Improved rock type discrimination in turn leads to better and more efficient geologic mapping which is carried out in the exploration, assessment and documentation of mineral resources and geologic hazards. Geologic maps also contribute significantly to the understanding of the natural history of the Earth and neighboring planetary bodies.

Bartholomew, M. J.↗

First Use of an Airborne Thermal Infrared Hyperspectral Scanner for Compositional Mapping

In May 1999, the airborne thermal infrared hyperspectral imaging system, Spatially Enhanced Broadband Array Spectrograph System (SEBASS), was flown over Mon-non Mesa, NV, to provide the first test of such a system for geological mapping. Several types of carbonate deposits were identified using the 11.25 microns band. However, massive calcrete outcrops exhibited weak spectral contrast, which was confirmed by field and laboratory measurements. Because the weathered calcrete surface appeared relatively smooth in hand specimen, this weak spectral contrast was unexpected. Here we show that microscopic roughness not readily apparent to the eye has introduced both a cavity effect and volume scattering to reduce spectral contrast. The macroroughness of crevices and cobbles may also have a significant cavity effect. The diminished spectral contrast is important because it places higher signal-to-noise ratio (SNR) requirements for spectroscopic detection and identification. This effect should be factored into instrumentation planning and interpretations, especially interpretations without benefit of ground truth. SEBASS had the required high SNR and spectral resolution to allow us to demonstrate for the first time the ability of an airborne hyperspectral thermal infrared scanner to detect and identify spectrally subtle materials.

Kirkland, Laurel↗

Thermal Performance Comparison and Lessons Learned for the Thermal Infrared Sensor Instruments 1 & 2

The Thermal Infrared Sensor (TIRS-1) is one of two instruments on the Landsat-8 Mission, which launched in February of 2013 and remains operational. The TIRS-2 instrument was developed for the Landsat-9 Mission, which is scheduled to launch in September of 2021. The TIRS-2 instrument design was adjusted to account for requirements changes and to include key lessons learned from its predecessor. The overall thermal subsystem design of the TIRS Sensor Unit remained comparable from mission to mission, but there were some areas that needed modifications. The general design is comprised of five thermal zones which range in temperature from less than 43 Kelvin to 320 Kelvin. Most zones are proportional heater controlled. A two-stage cryocooler provided by Ball Aerospace is used to cool the cryogenic subsystem, and excess power dissipation is rejected via ammonia transport heat pipes to a dedicated cryocooler radiator with embedded ammonia heat pipes. The cryogenic subsystem includes a series of shells used to radiatively and conductively isolate the cold stage from the warmer surroundings. The Optical System (telescope) is passively cooled to 180-195 Kelvin using a dedicated radiator with embedded dual-bore ethane heat pipes. The warmer end of the instrument includes a Scene Select Mechanism, an on-board Black Body Calibrator with a dedicated radiator, and a Focal Plane Electronics Box, all of which are attached to the Sensor Unit primary structure. The TIRS-1 thermal subsystem design was successfully verified during an extended testing campaign and during more than 8years of on-orbit operations. The TIRS-2 thermal subsystem design was successfully verified during months of ground testing prior to delivery in August of 2019and at the Observatory level in the Spring of 2021. A detailed comparison of the thermal performance of the two instruments has been made with a focus on key lessons learned during each instrument development, and with the benefit of on-orbit data acquired for the TIRS-1 instrument.

Veronica Otero↗

Tree Canopy Characterization for EO-1 Reflective and Thermal Infrared Validation Studies: Rochester, New York

The tree canopy characterization presented herein provided ground and tree canopy data for different types of tree canopies in support of EO-1 reflective and thermal infrared validation studies. These characterization efforts during August and September of 2001 included stem and trunk location surveys, tree structure geometry measurements, meteorology, and leaf area index (LAI) measurements. Measurements were also collected on thermal and reflective spectral properties of leaves, tree bark, leaf litter, soil, and grass. The data presented in this report were used to generate synthetic reflective and thermal infrared scenes and images that were used for the EO-1 Validation Program. The data also were used to evaluate whether the EO-1 ALI reflective channels can be combined with the Landsat-7 ETM+ thermal infrared channel to estimate canopy temperature, and also test the effects of separating the thermal and reflective measurements in time resulting from satellite formation flying.

Ballard, Jerrell R., Jr.↗

Thermal infrared pushbroom imagery acquisition and processing

A 9-element focal plane detector array and signal processing electronics was developed and delivered in December 1977. It was integrated into a thermal infrared imaging system using LSI microprocessor image processing and CRT display. After three years of laboratory operation, the focal plane has demonstrated high reliability and performance. On the basis of the 9-channel breadboard, the 90-element Aircraft Pushbroom IR/CCD Focal Plane Development Program was funded in October 1977. A follow-on program was awarded in July 1979, for the construction of a field test instrument and image processing facility. The objective of this project was to demonstrate thermal infrared pushbroom hard-copy imagery. It is pointed out that the successful development of the 9-element and 90-element thermal infrared hybrid imaging systems using photoconductive (Hg,Cd)Te has verified the operational concept of 8 to 14 micrometer pushbroom scanners.

Brown, T. J.↗

Landsat 9 Thermal Infrared Sensor 2 Pre-Launch Characterization: Initial Imaging & Spectral Performance Results

The Thermal Infrared Sensor-2 (TIRS-2) scheduled to launch in December 2020 aboard Landsat 9 will continue Landsat's four decade-long legacy of providing moderate resolution thermal imagery from low earth orbit (at 705 km) for environmental applications. Like the Thermal Infrared Sensor aboard Landsat 8, it is a pushbroom sensor with a cross-track field of view of 15 and provides two spectral channels at 10.8 and 12 um. To ensure radiometric, spatial, and spectral performance, a comprehensive pre-launch testing program is being conducted at NASA Goddard Space Flight Center at the component, subsystem, and instrument level. This effort will focus on the results from the subsystem level testing to assess TIRS-2 imaging performance including focus, spatial performance, and stray light rejection. It is also used to provide a preliminary assessment of spectral performance. The TIRS-2 subsystem is placed in a thermal vacuum chamber with the calibration ground support equipment, which provides a flexible blackbody illumination source and optics to assess imaging performance. Spectral performance is tested using a spectral response test setup with its own illumination source outside the chamber that propagates through the calibration ground support equipment in an optical configuration designed for this purpose. The results show that TIRS-2 performance is expected to meet all of its performance requirements with few waivers and deviations.

scatter↗

Multispectral thermal infrared mapping of the 1 October 1988 Kupaianaha flow field, Kilauea volcano, Hawaii

Multispectral thermal infrared radiance measurements of the Kupaianaha flow field were acquired with the NASA airborne Thermal Infrared Multispectral Scanner (TIMS) on the morning of 1 October 1988. The TIMS data were used to map both the temperature and emissivity of the surface of the flow field. The temperature map depicted the underground storage and transport of lava. The presence of molten lava in a tube or tumulus resulted in surface temperatures that were at least 10 C above ambient. The temperature map also clearly defined the boundaries of hydrothermal plumes which resulted from the entry of lava into the ocean. The emissivity map revealed the boundaries between individual flow units within the Kupaianaha field. Distinct spectral anomalies, indicative of silica-rich surface materials, were mapped near fumaroles and ocean entry sites. This apparent enrichment in silica may have resulted from an acid-induced leaching of cations from the surfaces of glassy flows.

Realmuto, Vincent J.↗

Thermal infrared emission spectroscopy of natural surfaces: Application to desert varnish coatings on rocks

Thermal infrared spectroscopy has become an increasingly important tool for remote compositional analysis and geologic mapping. Most published laboratory measurements have been obtained in bidirectional reflection or transmission, whereas remotely sensed thermal infrared data are obtained by measuring the emitted energy. Section 2 of this paper describes a laboratory technique for determining calibrated emissivities of natural surfaces. Equations are developed to account for the energy reflected from the environment and to determine directly the sample temperature from measurements of hot and cold blackbody targets. Two methods for determining emissivity are developed: one in which only a hot sample measurement is made and the reflected background energy is removed by modeling, and a second in which the sample is cooled and the reflected energy is measured directly. Relative emissivity can be obtained to approximately 1% and absolute emissivities can be obtained to 2-15%, depending on the validity of the assumption that the emissivity of the sample is unity at some wavelength. The emission data agree well within the hemispherically integrated reflection data but point out probelms associated with bidirectional reflectance measurements. Section 3 applies emissivity measurements to the study of layered surfaces consisting of desert varnish coatings on granite and granodiorite rock suites. Two linear models are developed: the first assumes linear mixing of independent emission from the substrate and varnish (checkerboard model); the second models tansmission through an absorbing/emitting medium. Regardless of whether the varnish is or is not relatively transparant and strongly absorptive, the spectral effect of varnish increases linearly with varnish thickness, indicating that thick patches of varnish dominate the spectral properties. As a result, medium varnish thickness can be determined from spectral measurements. In addition, the composition of a substrate can be estimated through varnish layers up to 40-50 micrometers in median thickness, and the composition of the varnish material can be determined if the substrate material is known. The varnishes studied are composed primarily of clay materials, consistent with previous studies of varnish composition.

Christensen, Philip R.↗

Thermal characteristics of mountain desert terrain derived from thermal infrared multispectral scanner measurements

The spatial and temporal variability of mountain-desert territory thermal is examined with an airborne thermal infrared multispectral scanner (TIMS). The purpose of the study is to demonstrate that inhomogeneities of the surface temperatures in the area can be adequately large to influence mesoscale circulations and the turbulence characteristics of boundary-layer flow. Ground truth measurements are compared to the TIMS imagery, with focus placed on the thermal infrared sensitivity to wet and dry soils, terrain elevation, and soil type. The results indicate that variations in the thermal features are dependent on soil type and soil moisture, and that the dependence on surface radiative temperatures on terrain elevation is apparent in daytime measurements.

Astling, E. G.↗

A comparison of techniques for extracting emissivity information from thermal infrared data for geologic studies

This article evaluates three techniques developed to extract emissivity information from multispectral thermal infrared data. The techniques are the assumed Channel 6 emittance model, thermal log residuals, and alpha residuals. These techniques were applied to calibrated, atmospherically corrected thermal infrared multispectral scanner (TIMS) data acquired over Cuprite, Nevada in September 1990. Results indicate that the two new techniques (thermal log residuals and alpha residuals) provide two distinct advantages over the assumed Channel 6 emittance model. First, they permit emissivity information to be derived from all six TIMS channels. The assumed Channel 6 emittance model only permits emissivity values to be derived from five of the six TIMS channels. Second, both techniques are less susceptible to noise than the assumed Channel 6 emittance model. The disadvantage of both techniques is that laboratory data must be converted to thermal log residuals or alpha residuals to facilitate comparison with similarly processed image data. An additional advantage of the alpha residual technique is that the processed data are scene-independent unlike those obtained with the other techniques.

Hook, Simon J.↗

Landsat 9 Thermal Infrared Sensor 2 Pre-Launch Characterization: Initial Imaging and Spectral Performance Results

The Thermal Infrared Sensor-2 (TIRS-2) scheduled to launch in December 2020 aboard Landsat 9 will continue Landsat's four decade-long legacy of providing moderate resolution thermal imagery from low earth orbit (at 705 km) for environmental applications. Like the Thermal Infrared Sensor aboard Landsat 8, it is a pushbroom sensor with a cross-track field of view of 15 and provides two spectral channels at 10.8 and 12 micrometers. To ensure radiometric, spatial, and spectral performance, a comprehensive pre-launch testing program is being conducted at NASA Goddard Space Flight Center at the component, subsystem, and instrument level. This effort will focus on the results from the subsystem level testing to assess TIRS-2 imaging performance including focus, spatial performance, and stray light rejection. It is also used to provide a preliminary assessment of spectral performance. The TIRS-2 subsystem is placed in a thermal vacuum chamber with the calibration ground support equipment, which provides a flexible blackbody illumination source and optics to assess imaging performance. Spectral performance is tested using a spectral response test setup with its own illumination source outside the chamber that propagates through the calibration ground support equipment in an optical configuration designed for this purpose. The results show that TIRS-2 performance is expected to meet all of its performance requirements with few waivers and deviations.

Landsat 9↗

Modeling thermal infrared (2-14 micrometer) reflectance spectra of frost and snow

Existing theories of radiative transfer in close-packed media assume that each particle scatters independently of its neighbors. For opaque particles, such as are common in the thermal infrared, this assumption is not valid, and these radiative transfer theories will not be accurate. A new method is proposed, called 'diffraction subtraction', which modifies the scattering cross section of close-packed large, opaque spheres to account for the effect of close packing on the diffraction cross section of a scattering particle. This method predicts the thermal infrared reflectance of coarse (greater than 50 micrometers radius), disaggregated granular snow. However, such coarse snow is typically old and metamorphosed, with adjacent grains welded together. The reflectance of such a welded block can be described as partly Fresnel in nature and cannot be predicted using Mie inputs to radiative transfer theory. Owing to the high absorption coefficient of ice in the thermal infrared, a rough surface reflectance model can be used to calculate reflectance from such a block. For very small (less than 50 micrometers), disaggregated particles, it is incorrect in principle to treat diffraction independently of reflection and refraction, and the theory fails. However, for particles larger than 50 micrometers, independent scattering is a valid assumption, and standard radiative transfer theory works.

Wald, Andrew E.↗

Tethered balloon-borne observations of thermal-infrared irradiance and cooling rate profiles in the Arctic atmospheric boundary layer

Clouds play an important role in controlling the radiative energy budget of the Arctic atmospheric boundary layer. To quantify the impact of clouds on the radiative heating or cooling of the lower atmosphere and of the surface, vertical profile observations of thermal-infrared irradiances were collected using a radiation measurement system carried by a tethered balloon. We present 70 profiles of thermal-infrared radiative quantities measured in summer 2020 during the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition and in autumn 2021 and spring 2022 in Ny-Ålesund, Svalbard. Measurements are classified into four groups: cloudless, low-level liquid-bearing cloud, elevated liquid-bearing cloud, and elevated ice cloud. Cloudless cases display an average radiative cooling rate of about —2 K d—1 throughout the atmospheric boundary layer. Instead, low-level liquid-bearing clouds are characterized by a radiative cooling up to —80 K d—1 within a shallow layer at cloud top, while no temperature tendencies are identified underneath the cloud layer. Radiative transfer simulations are performed to quantify the sensitivity of radiative cooling rates to cloud microphysical properties. In particular, cloud top cooling is strongly driven by the liquid water path, especially in optically thin clouds, while for optically thick clouds the cloud droplet number concentration has an increased influence. Additional radiative transfer simulations are used to demonstrate the enhanced radiative importance of the liquid relative to ice clouds. To analyze the temporal evolution of thermal-infrared radiation profiles during the transitions from a cloudy to a cloudless atmosphere, a respective case study is investigated.

54 ENVIRONMENTAL SCIENCES↗

Thermal Infrared Hot Spot and Dependence on Canopy Geometry

We perform theoretical calculations of the canopy thermal infrared (TIR) hot spot using a first principles 3-D model described earlier. Various theoretical canopies of varying leaf size and for differing canopy height are used to illustrate the magnitude of the TIR effect. Our results are similar to predicted behavior in the reflective hot spot as a function of canopy geometry and comparable to TIR measurements from the literature and our own simple ground experiments. We apply the MODTRAN atmospheric code to estimate the at-sensor variation in brightness temperature with view direction in the solar principal plane. For simple homogeneous canopies, we predict canopy thermal infrared hot spot variations of 2 degrees C at the surface with respect to nadir viewing. Dependence on leaf size is weak as long as the ratio of leaf size to canopy height is maintained. However, the angular width of the hot spot increases as the ratio of leaf diameter to canopy height increases. Atmospheric effects minimize but do not eliminate the TIR hot spot at satellite altitudes.

Smith, James A.↗

The new airborne Thermal Infrared Multispectral Scanner (TIMS)

A new airborne Thermal Infrared Multispectral Scanner (TIMS) with six bands between 8 and 12 microns is briefly characterized, and some results of remote sensing experiments are reported. The instrument has an instantaneous field of view of 2.5 milliradians, a total field of view of 80 deg, and a NE Delta T of approximately 0.1-0.3 C depending on the band. In the TIMS image of Death Valley, silica-rich rocks were easily separable from the nonsilicates. The Eureka Quartzite stood out in sharp contrast to other Ordovician and Cambrian metasediments, and Tertiary volcanic rocks were easily separable from both. Also distinguishable were various units in the fan gravels.

Kahle, A. B.↗