Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “texture segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

SU-E-J-262: Variability in Texture Analysis of Gynecological Tumors in the Context of An 18F-FDG PET Adaptive Protocol

Purpose: This study examines the effect on texture analysis due to variable reconstruction of PET images in the context of an adaptive FDG PET protocol for node positive gynecologic cancer patients. By measuring variability in texture features from baseline and intra-treatment PET-CT, we can isolate unreliable texture features due to large variation. Methods: A subset of seven patients with node positive gynecological cancers visible on PET was selected for this study. Prescribed dose varied between 45–50.4Gy, with a 55–70Gy boost to the PET positive nodes. A baseline and intratreatment (between 30–36Gy) PET-CT were obtained on a Siemens Biograph mCT. Each clinical PET image set was reconstructed 6 times using a TrueX+TOF algorithm with varying iterations and Gaussian filter. Baseline and intra-treatment primary GTVs were segmented using PET Edge (MIM Software Inc., Cleveland, OH), a semi-automatic gradient-based algorithm, on the clinical PET and transferred to the other reconstructed sets. Using an in-house MATLAB program, four 3D texture matrices describing relationships between voxel intensities in the GTV were generated: co-occurrence, run length, size zone, and neighborhood difference. From these, 39 textural features characterizing texture were calculated in addition to SUV histogram features. The percent variability among parameters was first calculated. Each reconstructed texture feature from baseline and intra-treatment per patient was normalized to the clinical baseline scan and compared using the Wilcoxon signed-rank test in order to isolate variations due to reconstruction parameters. Results: For the baseline scans, 13 texture features showed a mean range greater than 10%. For the intra scans, 28 texture features showed a mean range greater than 10%. Comparing baseline to intra scans, 25 texture features showed p <0.05. Conclusion: Variability due to different reconstruction parameters increased with treatment, however, the majority of texture features showed significant changes during treatment independent of reconstruction effects.

60 APPLIED LIFE SCIENCES↗

Development and testing of texture discriminators for the analysis of trabecular bone in proximal femur radiographs

Purpose: Texture analysis of femur radiographs may serve as a potential low cost technique to predict osteoporotic fracture risk and has received considerable attention in the past years. A further application of this technique may be the measurement of the quality of specific bone compartments to provide useful information for treatment of bone fractures. Two challenges of texture analysis are the selection of the best suitable texture measure and reproducible placement of regions of interest (ROIs). The goal of this in vitro study was to automatically place ROIs in radiographs of proximal femur specimens and to calculate correlations between various different texture analysis methods and the femurs' anchorage strength. Methods: Radiographs were obtained from 14 femoral specimens and bone mineral density (BMD) was measured in the femoral neck. Biomechanical testing was performed to assess the anchorage strength in terms of failure load, breakaway torque, and number of cycles. Images were segmented using a framework that is based on the usage of level sets and statistical in-shape models. Five ROIs were automatically placed in the head, upper and lower neck, trochanteric, and shaft compartment in an atlas subject. All other subjects were registered rigidly, affinely, and nonlinearly, and the resulting transformation was used to map the five ROIs onto the individual femora. Results: In each ROI, texture features were extracted using gray level co-occurence matrices (GLCM), third-order GLCM, morphological gradients (MGs), Minkowski dimensions (MDs), Minkowski functionals (MFs), Gaussian Markov random fields, and scaling index method (SIM). Coefficients of determination for each texture feature with parameters of anchorage strength were computed. In a stepwise multiregression analysis, the most predictive parameters were identified in different models. Texture features were highly correlated with anchorage strength estimated by the failure load of up to R{sup 2}=0.61 (MF and MG features, p<0.01) and were partially independent of BMD. The correlations were dependent on the choice of the ROI and the texture measure. The best predictive multiregression model for failure load R{sub adj}{sup 2}=0.86 (p<0.001) included a set of recently developed texture methods (MF and SIM) but excluded bone mineral density and commonly used texture measures. Conclusions: The results suggest that texture information contained in trabecular bone structure visualized on radiographs may predict whether an implant anchorage can be used and may determine the local bone quality from preoperative radiographs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-CD-BRB-04: Automated Radiomic Features Complement the Prognostic Value of VASARI in the TCGA-GBM Dataset

Purpose: To compare the complementary prognostic value of automated Radiomic features to that of radiologist-annotated VASARI features in TCGA-GBM MRI dataset. Methods: For 96 GBM patients, pre-operative MRI images were obtained from The Cancer Imaging Archive. The abnormal tumor bulks were manually defined on post-contrast T1w images. The contrast-enhancing and necrotic regions were segmented using FAST. From these sub-volumes and the total abnormal tumor bulk, a set of Radiomic features quantifying phenotypic differences based on the tumor intensity, shape and texture, were extracted from the post-contrast T1w images. Minimum-redundancy-maximum-relevance (MRMR) was used to identify the most informative Radiomic, VASARI and combined Radiomic-VASARI features in 70% of the dataset (training-set). Multivariate Cox-proportional hazards models were evaluated in 30% of the dataset (validation-set) using the C-index for OS. A bootstrap procedure was used to assess significance while comparing the C-Indices of the different models. Results: Overall, the Radiomic features showed a moderate correlation with the radiologist-annotated VASARI features (r = −0.37 – 0.49); however that correlation was stronger for the Tumor Diameter and Proportion of Necrosis VASARI features (r = −0.71 – 0.69). After MRMR feature selection, the best-performing Radiomic, VASARI, and Radiomic-VASARI Cox-PH models showed a validation C-index of 0.56 (p = NS), 0.58 (p = NS) and 0.65 (p = 0.01), respectively. The combined Radiomic-VASARI model C-index was significantly higher than that obtained from either the Radiomic or VASARI model alone (p = <0.001). Conclusion: Quantitative volumetric and textural Radiomic features complement the qualitative and semi-quantitative annotated VASARI feature set. The prognostic value of informative qualitative VASARI features such as Eloquent Brain and Multifocality is increased with the addition of quantitative volumetric and textural features from the contrast-enhancing and necrotic tumor regions. These results should be further evaluated in larger validation cohorts.

60 APPLIED LIFE SCIENCES↗

SU-F-R-38: Impact of Smoothing and Noise On Robustness of CBCT Textural Features for Prediction of Response to Radiotherapy Treatment of Head and Neck Cancers

Purpose: To examine the impact of image smoothing and noise on the robustness of textural information extracted from CBCT images for prediction of radiotherapy response for patients with head/neck (H/N) cancers. Methods: CBCT image datasets for 14 patients with H/N cancer treated with radiation (70 Gy in 35 fractions) were investigated. A deformable registration algorithm was used to fuse planning CT’s to CBCT’s. Tumor volume was automatically segmented on each CBCT image dataset. Local control at 1-year was used to classify 8 patients as responders (R), and 6 as non-responders (NR). A smoothing filter [2D Adaptive Weiner (2DAW) with 3 different windows (ψ=3, 5, and 7)], and two noise models (Poisson and Gaussian, SNR=25) were implemented, and independently applied to CBCT images. Twenty-two textural features, describing the spatial arrangement of voxel intensities calculated from gray-level co-occurrence matrices, were extracted for all tumor volumes. Results: Relative to CBCT images without smoothing, none of 22 textural features extracted showed any significant differences when smoothing was applied (using the 2DAW with filtering parameters of ψ=3 and 5), in the responder and non-responder groups. When smoothing, 2DAW with ψ=7 was applied, one textural feature, Information Measure of Correlation, was significantly different relative to no smoothing. Only 4 features (Energy, Entropy, Homogeneity, and Maximum-Probability) were found to be statistically different between the R and NR groups (Table 1). These features remained statistically significant discriminators for R and NR groups in presence of noise and smoothing. Conclusion: This preliminary work suggests that textural classifiers for response prediction, extracted from H&N CBCT images, are robust to low-power noise and low-pass filtering. While other types of filters will alter the spatial frequencies differently, these results are promising. The current study is subject to Type II errors. A much larger cohort of patients is needed to confirm these results. This work was supported in part by a grant from Varian Medical Systems (Palo Alto, CA)

60 APPLIED LIFE SCIENCES↗

Remote sensing detection enhancement

Big Data in the area of Remote Sensing has been growing rapidly. Remote sensors are used in surveillance, security, traffic, environmental monitoring, and autonomous sensing. Real-time detection of small moving targets using a remote sensor is an ongoing, challenging problem. Since the object is located far away from the sensor, the object often appears too small. The object’s signal-to-noise-ratio (SNR) is often very low. Occurrences such as camera motion, moving backgrounds (e.g., rustling leaves), low contrast and resolution of foreground objects makes it difficult to segment out the targeted moving objects of interest. Due to the limited appearance of the target, it is tough to obtain the target’s characteristics such as its shape and texture. Without these characteristics, filtering out false detections can be a difficult task. Detecting these targets, would often require the detector to operate under a low detection threshold. However, lowering the detection threshold could lead to an increase of false alarms. In this paper, the author will introduce a new method that improves the probability to detect low SNR objects, while decreasing the number of false alarms as compared to using the traditional baseline detection technique.

47 OTHER INSTRUMENTATION↗

Automated Segmentation of the Parotid Gland Based on Atlas Registration and Machine Learning: A Longitudinal MRI Study in Head-and-Neck Radiation Therapy

Purpose: To develop an automated magnetic resonance imaging (MRI) parotid segmentation method to monitor radiation-induced parotid gland changes in patients after head and neck radiation therapy (RT). Methods and Materials: The proposed method combines the atlas registration method, which captures the global variation of anatomy, with a machine learning technology, which captures the local statistical features, to automatically segment the parotid glands from the MRIs. The segmentation method consists of 3 major steps. First, an atlas (pre-RT MRI and manually contoured parotid gland mask) is built for each patient. A hybrid deformable image registration is used to map the pre-RT MRI to the post-RT MRI, and the transformation is applied to the pre-RT parotid volume. Second, the kernel support vector machine (SVM) is trained with the subject-specific atlas pair consisting of multiple features (intensity, gradient, and others) from the aligned pre-RT MRI and the transformed parotid volume. Third, the well-trained kernel SVM is used to differentiate the parotid from surrounding tissues in the post-RT MRIs by statistically matching multiple texture features. A longitudinal study of 15 patients undergoing head and neck RT was conducted: baseline MRI was acquired prior to RT, and the post-RT MRIs were acquired at 3-, 6-, and 12-month follow-up examinations. The resulting segmentations were compared with the physicians' manual contours. Results: Successful parotid segmentation was achieved for all 15 patients (42 post-RT MRIs). The average percentage of volume differences between the automated segmentations and those of the physicians' manual contours were 7.98% for the left parotid and 8.12% for the right parotid. The average volume overlap was 91.1% ± 1.6% for the left parotid and 90.5% ± 2.4% for the right parotid. The parotid gland volume reduction at follow-up was 25% at 3 months, 27% at 6 months, and 16% at 12 months. Conclusions: We have validated our automated parotid segmentation algorithm in a longitudinal study. This segmentation method may be useful in future studies to address radiation-induced xerostomia in head and neck radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Iris Segmentation Algorithm based on Edge Orientation for Off-angle Iris Recognition

Iris recognition is known as one of the most accurate and reliable biometrics. However, the accuracy of iris recognition systems depends on the quality of data capture and is negatively affected by several factors such as angle, occlusion, and dilation. In this paper, we present a segmentation algorithm for off-angle iris images that uses edge detection, edge elimination, edge classification, and ellipse fitting techniques. In our approach, we first detect all candidate edges in the iris image by using the canny edge detector; this collection contains edges from the iris and pupil boundaries as well as eyelash, eyelids, iris texture etc. Edge orientation is used to eliminate the edges that cannot be part of the iris or pupil. Then, we classify the remaining edge points into two sets as pupil edges and iris edges. Finally, we randomly generate subsets of iris and pupil edge points, fit ellipses for each subset, select ellipses with similar parameters, and average to form the resultant ellipses. Based on the results from real experiments, the proposed method shows effectiveness in segmentation for off-angle iris images.

Karakaya, Mahmut↗

COE Task Order 4. Final Report: Automated Threat Recognition

Lawrence Livermore National Laboratory (LLNL) was tasked by the Department of Homeland Security (DHS) Science and Technology Directorate (S&T) with developing an automated target recognition algorithm for finding objects of interest in checked baggage at airports. The project used x-ray computed tomography (CT) data collected on a medical scanner of various simulated checked bags. Target objects of interest include clay, rubber, and saline in various concentrations. The final results are 93.9% probability of detection (P D ) with 11.9% probability of false alarm (PFA) on all targets and 100% detection for pseudo target sheets. This result is achieved by using a three-stage algorithm made up of segmentation, post-processing, and feature extraction and object classification. The segmentation proved to be the most important stage and it involves merging two distinct segmentation results followed by a set of algorithms for cleaning up the merged segmentations. The first segmentation algorithm operates on planar 10x10 voxel slabs (two- dimensional segments) in the three spatial planes. The segmenter calculates a probability that each slab in the image is a part of a target, determines if the probability was above a threshold, and then merges all connected slabs together. The second segmentation algorithm is an ensemble segmenter, which generates a set of possible segmentations through random permutations and computes an average behavior. The distinct properties of these segmenters results in a merged segmentation with superior results than either segmenter alone. The merged segmentation is “cleaned up” using post processing techniques to achieve the final labeled images. The final classification stage made use of a random forest classifier algorithm to discriminate targets from non-targets based on a set of features of the segmented objects partially from the voxel slabs and partially from the individual voxels. Features include standard statistics such as mean, median, and standard deviations of the density, features capturing some aspects of texture, and some features about the surrounding bag structure. In addition to the detection and false alarm results above, we show how the algorithms can be trained to “overfit” to the limited data set provided and achieve near perfect results (P D =100% and P FA =0%). This over-training is not recommended for long-term operation, but instead is meant to demonstrate how test design is an important factor in aviation security. Possible improvements to the algorithm and the testing methodology (including blind testing) are also presented.

42 ENGINEERING↗

WE-D-18A-05: Construction of Realistic Liver Phantoms From Patient Images and a Commercial 3D Printer

Purpose: To assess image quality and radiation dose reduction in abdominal CT imaging, physical phantoms having realistic background textures and lesions are highly desirable. The purpose of this work was to construct a liver phantom with realistic background and lesions using patient CT images and a 3D printer. Methods: Patient CT images containing liver lesions were segmented into liver tissue, contrast-enhanced vessels, and liver lesions using commercial software (Mimics, Materialise, Belgium). Stereolithography (STL) files of each segmented object were created and imported to a 3D printer (Object350 Connex, Stratasys, MN). After test scans were performed to map the eight available printing materials into CT numbers, printing materials were assigned to each object and a physical liver phantom printed. The printed phantom was scanned on a clinical CT scanner and resulting images were compared with the original patient CT images. Results: The eight available materials used to print the liver phantom had CT number ranging from 62 to 117 HU. In scans of the liver phantom, the liver lesions and veins represented in the STL files were all visible. Although the absolute value of the CT number in the background liver material (approx. 85 HU) was higher than in patients (approx. 40 HU), the difference in CT numbers between lesions and background were representative of the low contrast values needed for optimization tasks. Future work will investigate materials with contrast sufficient to emulate contrast-enhanced arteries. Conclusion: Realistic liver phantoms can be constructed from patient CT images using a commercial 3D printer. This technique may provide phantoms able to determine the effect of radiation dose reduction and noise reduction techniques on the ability to detect subtle liver lesions in the context of realistic background textures.

60 APPLIED LIFE SCIENCES↗

SU-E-J-275: Review - Computerized PET/CT Image Analysis in the Evaluation of Tumor Response to Therapy

Purpose: To review the literature in using computerized PET/CT image analysis for the evaluation of tumor response to therapy. Methods: We reviewed and summarized more than 100 papers that used computerized image analysis techniques for the evaluation of tumor response with PET/CT. This review mainly covered four aspects: image registration, tumor segmentation, image feature extraction, and response evaluation. Results: Although rigid image registration is straightforward, it has been shown to achieve good alignment between baseline and evaluation scans. Deformable image registration has been shown to improve the alignment when complex deformable distortions occur due to tumor shrinkage, weight loss or gain, and motion. Many semi-automatic tumor segmentation methods have been developed on PET. A comparative study revealed benefits of high levels of user interaction with simultaneous visualization of CT images and PET gradients. On CT, semi-automatic methods have been developed for only tumors that show marked difference in CT attenuation between the tumor and the surrounding normal tissues. Quite a few multi-modality segmentation methods have been shown to improve accuracy compared to single-modality algorithms. Advanced PET image features considering spatial information, such as tumor volume, tumor shape, total glycolytic volume, histogram distance, and texture features have been found more informative than the traditional SUVmax for the prediction of tumor response. Advanced CT features, including volumetric, attenuation, morphologic, structure, and texture descriptors, have also been found advantage over the traditional RECIST and WHO criteria in certain tumor types. Predictive models based on machine learning technique have been constructed for correlating selected image features to response. These models showed improved performance compared to current methods using cutoff value of a single measurement for tumor response. Conclusion: This review showed that computerized PET/CT image analysis holds great potential to improve the accuracy in evaluation of tumor response. This work was supported in part by the National Cancer Institute Grant R01CA172638.

60 APPLIED LIFE SCIENCES↗

Multiscale characterization and representation of variability in ceramic matrix composites

Low density, high strength, and high creep and oxidation resistance properties of ceramic matrix composites (CMCs) make them an ideal choice for use in extreme environments in space and military applications. This paper presents a detailed characterization study of structural and manufacturing flaws in Carbon fiber Silicon-Carbide-Nitride matrix (C/SiNC) CMCs at different length-scales. Energy-dispersive spectroscopy (EDS) is used for the chemical characterization of the material’s elemental constituents. High-resolution multiscale graphs obtained from scanning electron microscope (SEM) and confocal laser scanning microscope (LSM) are used to characterize the distribution and morphology of defects at different length scales. This is followed by the classification and quantification of the common manufacturing defects. An image processing algorithm based on the image segmentation process is developed to quantify the variability of various scale-dependent architectural parameters. Finally, a three-dimensional stochastic representative volume element (SRVE) generation algorithm is developed to provide precise representations of material textures at multiple length scales. The developed algorithm accurately accounts for material features and flaws based on a range of multiscale structural and defects characterization results.

36 MATERIALS SCIENCE↗

SU-F-R-46: Predicting Distant Failure in Lung SBRT Using Multi-Objective Radiomics Model

Purpose: To predict distant failure in lung stereotactic body radiation therapy (SBRT) in early stage non-small cell lung cancer (NSCLC) by using a new multi-objective radiomics model. Methods: Currently, most available radiomics models use the overall accuracy as the objective function. However, due to data imbalance, a single object may not reflect the performance of a predictive model. Therefore, we developed a multi-objective radiomics model which considers both sensitivity and specificity as the objective functions simultaneously. The new model is used to predict distant failure in lung SBRT using 52 patients treated at our institute. Quantitative imaging features of PET and CT as well as clinical parameters are utilized to build the predictive model. Image features include intensity features (9), textural features (12) and geometric features (8). Clinical parameters for each patient include demographic parameters (4), tumor characteristics (8), treatment faction schemes (4) and pretreatment medicines (6). The modelling procedure consists of two steps: extracting features from segmented tumors in PET and CT; and selecting features and training model parameters based on multi-objective. Support Vector Machine (SVM) is used as the predictive model, while a nondominated sorting-based multi-objective evolutionary computation algorithm II (NSGA-II) is used for solving the multi-objective optimization. Results: The accuracy for PET, clinical, CT, PET+clinical, PET+CT, CT+clinical, PET+CT+clinical are 71.15%, 84.62%, 84.62%, 85.54%, 82.69%, 84.62%, 86.54%, respectively. The sensitivities for the above seven combinations are 41.76%, 58.33%, 50.00%, 50.00%, 41.67%, 41.67%, 58.33%, while the specificities are 80.00%, 92.50%, 90.00%, 97.50%, 92.50%, 97.50%, 97.50%. Conclusion: A new multi-objective radiomics model for predicting distant failure in NSCLC treated with SBRT was developed. The experimental results show that the best performance can be obtained by combining all features.

60 APPLIED LIFE SCIENCES↗

Correlative feature analysis on FFDM

Identifying the corresponding images of a lesion in different views is an essential step in improving the diagnostic ability of both radiologists and computer-aided diagnosis (CAD) systems. Because of the nonrigidity of the breasts and the 2D projective property of mammograms, this task is not trivial. In this pilot study, we present a computerized framework that differentiates between corresponding images of the same lesion in different views and noncorresponding images, i.e., images of different lesions. A dual-stage segmentation method, which employs an initial radial gradient index (RGI) based segmentation and an active contour model, is applied to extract mass lesions from the surrounding parenchyma. Then various lesion features are automatically extracted from each of the two views of each lesion to quantify the characteristics of density, size, texture and the neighborhood of the lesion, as well as its distance to the nipple. A two-step scheme is employed to estimate the probability that the two lesion images from different mammographic views are of the same physical lesion. In the first step, a correspondence metric for each pairwise feature is estimated by a Bayesian artificial neural network (BANN). Then, these pairwise correspondence metrics are combined using another BANN to yield an overall probability of correspondence. Receiver operating characteristic (ROC) analysis was used to evaluate the performance of the individual features and the selected feature subset in the task of distinguishing corresponding pairs from noncorresponding pairs. Using a FFDM database with 123 corresponding image pairs and 82 noncorresponding pairs, the distance feature yielded an area under the ROC curve (AUC) of 0.81{+-}0.02 with leave-one-out (by physical lesion) evaluation, and the feature metric subset, which included distance, gradient texture, and ROI-based correlation, yielded an AUC of 0.87{+-}0.02. The improvement by using multiple feature metrics was statistically significant compared to single feature performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-202-02: Quantitative Imaging: Correlation Between Image Feature Analysis and the Accuracy of Manually Drawn Contours On PET Images

Purpose: To evaluate the correlation between image features and the accuracy of manually drawn target contours on synthetic PET images Methods: A digital PET phantom was used in combination with Monte Carlo simulation to create a set of 26 simulated PET images featuring a variety of tumor shapes and activity heterogeneity. These tumor volumes were used as a gold standard in comparisons with manual contours delineated by 10 radiation oncologist on the simulated PET images. Metrics used to evaluate segmentation accuracy included the dice coefficient, false positive dice, false negative dice, symmetric mean absolute surface distance, and absolute volumetric difference. Image features extracted from the simulated tumors consisted of volume, shape complexity, mean curvature, and intensity contrast along with five texture features derived from the gray-level neighborhood difference matrices including contrast, coarseness, busyness, strength, and complexity. Correlation between these features and contouring accuracy were examined. Results: Contour accuracy was reasonably well correlated with a variety of image features. Dice coefficient ranged from 0.7 to 0.90 and was correlated closely with contrast (r=0.43, p=0.02) and complexity (r=0.5, p<0.001). False negative dice ranged from 0.10 to 0.50 and was correlated closely with contrast (r=0.68, p<0.001) and complexity (r=0.66, p<0.001). Absolute volumetric difference ranged from 0.0002 to 0.67 and was correlated closely with coarseness (r=0.46, p=0.02) and complexity (r=0.49, p=0.008). Symmetric mean absolute difference ranged from 0.02 to 1 and was correlated closely with mean curvature (r=0.57, p=0.02) and contrast (r=0.6, p=0.001). Conclusion: The long term goal of this study is to assess whether contouring variability can be reduced by providing feedback to the practitioner based on image feature analysis. The results are encouraging and will be used to develop a statistical model which will enable a prediction of contour accuracy based purely on image feature analysis.

60 APPLIED LIFE SCIENCES↗

A region-based segmentation method for ultrasound images in HIFU therapy

Purpose: Precisely and efficiently locating a tumor with less manual intervention in ultrasound-guided high-intensity focused ultrasound (HIFU) therapy is one of the keys to guaranteeing the therapeutic result and improving the efficiency of the treatment. The segmentation of ultrasound images has always been difficult due to the influences of speckle, acoustic shadows, and signal attenuation as well as the variety of tumor appearance. The quality of HIFU guidance images is even poorer than that of conventional diagnostic ultrasound images because the ultrasonic probe used for HIFU guidance usually obtains images without making contact with the patient’s body. Therefore, the segmentation becomes more difficult. To solve the segmentation problem of ultrasound guidance image in the treatment planning procedure for HIFU therapy, a novel region-based segmentation method for uterine fibroids in HIFU guidance images is proposed. Methods: Tumor partitioning in HIFU guidance image without manual intervention is achieved by a region-based split-and-merge framework. A new iterative multiple region growing algorithm is proposed to first split the image into homogenous regions (superpixels). The features extracted within these homogenous regions will be more stable than those extracted within the conventional neighborhood of a pixel. The split regions are then merged by a superpixel-based adaptive spectral clustering algorithm. To ensure the superpixels that belong to the same tumor can be clustered together in the merging process, a particular construction strategy for the similarity matrix is adopted for the spectral clustering, and the similarity matrix is constructed by taking advantage of a combination of specifically selected first-order and second-order texture features computed from the gray levels and the gray level co-occurrence matrixes, respectively. The tumor region is picked out automatically from the background regions by an algorithm according to a priori information about the tumor position, shape, and size. Additionally, an appropriate cluster number for spectral clustering can be determined by the same algorithm, thus the automatic segmentation of the tumor region is achieved. Results: To evaluate the performance of the proposed method, 50 uterine fibroid ultrasound images from different patients receiving HIFU therapy were segmented, and the obtained tumor contours were compared with those delineated by an experienced radiologist. For area-based evaluation results, the mean values of the true positive ratio, the false positive ratio, and the similarity were 94.42%, 4.71%, and 90.21%, respectively, and the corresponding standard deviations were 2.54%, 3.12%, and 3.50%, respectively. For distance-based evaluation results, the mean values of the normalized Hausdorff distance and the normalized mean absolute distance were 4.93% and 0.90%, respectively, and the corresponding standard deviations were 2.22% and 0.34%, respectively. The running time of the segmentation process was 12.9 s for a 318 × 333 (pixels) image. Conclusions: Experiments show that the proposed method can segment the tumor region accurately and efficiently with less manual intervention, which provides for the possibility of automatic segmentation and real-time guidance in HIFU therapy.

60 APPLIED LIFE SCIENCES↗

The correlation study of parallel feature extractor and noise reduction approaches

This paper presents literature reviews that show variety of techniques to develop parallel feature extractor and finding its correlation with noise reduction approaches for low light intensity images. Low light intensity images are normally displayed as darker images and low contrast. Without proper handling techniques, those images regularly become evidences of misperception of objects and textures, the incapability to section them. The visual illusions regularly clues to disorientation, user fatigue, poor detection and classification performance of humans and computer algorithms. Noise reduction approaches (NR) therefore is an essential step for other image processing steps such as edge detection, image segmentation, image compression, etc. Parallel Feature Extractor (PFE) meant to capture visual contents of images involves partitioning images into segments, detecting image overlaps if any, and controlling distributed and redistributed segments to extract the features. Working on low light intensity images make the PFE face challenges and closely depend on the quality of its pre-processing steps. Some papers have suggested many well established NR as well as PFE strategies however only few resources have suggested or mentioned the correlation between them. This paper reviews best approaches of the NR and the PFE with detailed explanation on the suggested correlation. This finding may suggest relevant strategies of the PFE development. With the help of knowledge based reasoning, computational approaches and algorithms, we present the correlation study between the NR and the PFE that can be useful for the development and enhancement of other existing PFE.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

STRUCTURAL ANNOTATION OF EM IMAGES BY GRAPH CUT

Biological images have the potential to reveal complex signatures that may not be amenable to morphological modeling in terms of shape, location, texture, and color. An effective analytical method is to characterize the composition of a specimen based on user-defined patterns of texture and contrast formation. However, such a simple requirement demands an improved model for stability and robustness. Here, an interactive computational model is introduced for learning patterns of interest by example. The learned patterns bound an active contour model in which the traditional gradient descent optimization is replaced by the more efficient optimization of the graph cut methods. First, the energy function is defined according to the curve evolution. Next, a graph is constructed with weighted edges on the energy function and is optimized with the graph cut algorithm. As a result, the method combines the advantages of the level set method and graph cut algorithm, i.e.,"topological" invariance and computational efficiency. The technique is extended to the multi-phase segmentation problem; the method is validated on synthetic images and then applied to specimens imaged by transmission electron microscopy(TEM).

60 APPLIED LIFE SCIENCES↗

Variational and Shape Prior-based Level Set Model for Image Segmentation

A new image segmentation model based on level sets approach is presented herein. We deal with radiographic medical images where boundaries are not salient, and objects of interest have the same gray level as other structures in the image. Thus, an a priori information about the shape we look for is integrated in the level set evolution for good segmentation results. The proposed model also accounts a penalization term that forces the level set to be close to a signed distance function (SDF), which then avoids the re-initialization procedure. In addition, a variant and complete Mumford-Shah model is used in our functional; the added Hausdorff measure helps to better handle zones where boundaries are occluded or not salient. Finally, a weighted area term is added to the functional to make the level set drive rapidly to object's boundaries. The segmentation model is formulated in a variational framework, which, thanks to calculus of variations, yields to partial differential equations (PDEs) to guide the level set evolution. Results obtained on both synthetic and digital radiographs reconstruction (DRR) show that the proposed model improves on existing prior and non-prior shape based image segmentation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗