Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “texture analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Crop identification of SAR data using digital textural analysis

After preprocessing SEASAT SAR data which included slant to ground range transformation, registration to LANDSAT MSS data and appropriate filtering of the raw SAR data to minimize coherent speckle, textural features were developed based upon the spatial gray level dependence method (SGLDM) to compute entropy and inertia as textural measures. It is indicated that the consideration of texture features are very important in SAR data analysis. The SEASAT SAR data are useful for the improvement of field boundary definitions and for an earlier season estimate of corn and soybean area location than is supported by LANDSAT alone.

Nuesch, D. R.↗

Texture Analysis of Inconel 718 with Different Modes During Single-Track Laser Surface Re-Melting

An in-depth understanding of the texture formation in melt pools allows for the modification of the surface layer microstructure and corresponding material properties, providing an opportunity to integrate laser surface re-melting into metal additive manufacturing. This study investigates crystallographic texture formation at different cooling rates in single melting tracks on the Inconel 718 (IN718) plate produced by laser surface re-melting. The cooling rate varies from 2.31 × 10 5 °C/s to 9.56 × 10 5 °C/s with the increase in scanning rates from 400 mm/s to 1200 mm/s, measured by recently developed real-time temperature monitoring of melt pools. Columnar grains are dominant, with distinct crystallographic textures forming in the melt pools. At a slower scanning speed, the keyhole mode shows three different textures forming at different depths (crystallographically layered structure), while, at a faster scanning speed, the conduction mode shows only random grain orientation. There are no pores/voids detected, and the columnar grain morphology and columnar grain width (8.6 μm to 12.4 μm) follow the analysis framework in terms of thermal gradient and solidification rate analysis. This implies that laser surface re-melting provides the potential to modify the surface structure from a random grain orientation to a crystallographically layered structure.

36 MATERIALS SCIENCE↗

TU-D-207B-03: Early Assessment of Response to Chemoradiotherapy Based On Textural Analysis of Pre and Mid-Treatment FDG-PET Image in Locally Advanced Head and Neck Cancer

Purpose: To evaluate whether tumor textural features extracted from both pre- and mid-treatment FDG-PET images predict early response to chemoradiotherapy in locally advanced head and neck cancer, and investigate whether they provide complementary value to conventional volume-based measurements. Methods: Ninety-four patients with locally advanced head and neck cancers were retrospectively studied. All patients received definitive chemoradiotherapy and underwent FDG-PET planning scans both before and during treatment. Within the primary tumor we extracted 6 textural features based on gray-level co-occurrence matrices (GLCM): entropy, dissimilarity, contrast, correlation, energy, and homogeneity. These image features were evaluated for their predictive power of treatment response to chemoradiotherapy in terms of local recurrence free survival (LRFS) and progression free survival (PFS). Logrank test were used to assess the statistical significance of the stratification between low- and high-risk groups. P-values were adjusted for multiple comparisons by the false discovery rate (FDR) method. Results: All six textural features extracted from pre-treatment PET images significantly differentiated low- and high-risk patient groups for LRFS (P=0.011–0.038) and PFS (P=0.029–0.034). On the other hand, none of the textural features on mid-treatment PET images was statistically significant in stratifying LRFS (P=0.212–0.445) or PFS (P=0.168–0.299). An imaging signature that combines textural feature (GLCM homogeneity) and metabolic tumor volume showed an improved performance for predicting LRFS (hazard ratio: 22.8, P<0.0001) and PFS (hazard ratio: 13.9, P=0.0005) in leave-one-out cross validation. Intra-tumor heterogeneity measured by textural features was significantly lower in mid-treatment PET images than in pre-treatment PET images (T-test: P<1.4e-6). Conclusion: Tumor textural features on pretreatment FDG-PET images are predictive for response to chemoradiotherapy in locally advanced head and neck cancer. The complementary information offered by textural features improves patient stratification and may potentially aid in personalized risk-adaptive therapy.

60 APPLIED LIFE SCIENCES↗

TU-D-207B-05: Intra-Tumor Partitioning and Texture Analysis of DCE-MRI Identifies Relevant Tumor Subregions to Predict Early Pathological Response of Breast Cancer to Neoadjuvant Chemotherapy

Purpose: To predict early pathological response of breast cancer to neoadjuvant chemotherapy (NAC) based on quantitative, multi-region analysis of dynamic contrast enhancement magnetic resonance imaging (DCE-MRI). Methods: In this institution review board-approved study, 35 patients diagnosed with stage II/III breast cancer were retrospectively investigated using DCE-MR images acquired before and after the first cycle of NAC. First, principal component analysis (PCA) was used to reduce the dimensionality of the DCE-MRI data with a high-temporal resolution. We then partitioned the whole tumor into multiple subregions using k-means clustering based on the PCA-defined eigenmaps. Within each tumor subregion, we extracted four quantitative Haralick texture features based on the gray-level co-occurrence matrix (GLCM). The change in texture features in each tumor subregion between pre- and during-NAC was used to predict pathological complete response after NAC. Results: Three tumor subregions were identified through clustering, each with distinct enhancement characteristics. In univariate analysis, all imaging predictors except one extracted from the tumor subregion associated with fast wash-out were statistically significant (p< 0.05) after correcting for multiple testing, with area under the ROC curve or AUCs between 0.75 and 0.80. In multivariate analysis, the proposed imaging predictors achieved an AUC of 0.79 (p = 0.002) in leave-one-out cross validation. This improved upon conventional imaging predictors such as tumor volume (AUC=0.53) and texture features based on whole-tumor analysis (AUC=0.65). Conclusion: The heterogeneity of the tumor subregion associated with fast wash-out on DCE-MRI predicted early pathological response to neoadjuvant chemotherapy in breast cancer.

60 APPLIED LIFE SCIENCES↗

Texture analysis of radiometric signatures of new sea ice forming in Arctic leads

Analysis of 33.6-GHz, high-resolution, passive microwave images suggests that new sea ice accumulating in open leads is characterized by a unique textural signature which can be used to discriminate new ice forming in this environment from adjacent surfaces of similar radiometric temperature. Ten training areas were selected from the data set, three of which consisted entirely of first-year ice, four entirely of multilayer ice, and three of new ice in open leads in the process of freezing. A simple gradient operator was used to characterize the radiometric texture in each training region in terms of the degree to which radiometric gradients are oriented. New ice in leads has a sufficiently high proportion of well-oriented features to distinguish it uniquely from first-year ice and multiyear ice. The predominance of well-oriented features probably reflects physical processes by which new ice accumulates in open leads. Banded structures, which are evident in aerial photographs of new ice, apparently give rise to the radiometric signature observed, in which the trend of brightness temperature gradients is aligned parallel to lead trends. First-year ice and multiyear ice, which have been subjected to a more random growth and process history, lack this banded structure and therefore are characterized by signatures in which well-aligned elements are less dominant.

Eppler, Duane T.↗

Texture Analysis for Enhancement of R-value in Asymmetrically Rolled Al Alloy Sheet

When Al alloy sheet is reduced in thickness by 84% with asymmetric rolling and heat treatment, this sheet simultaneously develops a {001}〈110〉 texture, which decreases the R-value, and a 〈111〉//normal direction (ND) texture, which enhances the R-value. To control the intensities of these {001}〈110〉 and 〈111〉//ND texture components, an 84% heavy asymmetrically rolled and heat-treated AA1050 Al alloy sheet was 20% light asymmetrically rolled and heat-treated at 500 °C for 1 h. This process increased the amount of 〈111〉//ND texture component and reduced the amount of the {001}〈110〉 texture component, resulting in an R-bar -value of 1.3. This was 2.13 times higher than the R-bar -value of 0.61 obtained for the initial specimen that had {001}〈100〉 component.

36 MATERIALS SCIENCE↗

Equal channel angular extrusion for bulk processing of Fe–Co–2V soft magnetic alloys, part II: Texture analysis and magnetic properties

In Part I, equal channel angular extrusion (ECAE) was demonstrated as a novel, simple-shear deformation process for producing bulk forms of the low ductility Fe–Co–2V (Hiperco 50A®) soft ferromagnetic alloy with refined grain sizes. Microstructures and mechanical properties were discussed. In this Part II contribution, the crystallographic textures and quasi-static magnetic properties of ECAE-processed Hiperco were characterized. The textures were of a simple-shear character defined by partial {110} and <111> fibers inclined relative to the extrusion direction, in agreement with the expectations for simple-shear deformation textures of BCC metals. These textures were observed throughout all processing conditions and only slightly reduced in intensity by subsequent recrystallization heat treatments. Characterization of the magnetic properties revealed a lower coercivity and higher permeability for ECAE-processed Hiperco specimens relative to the conventionally processed and annealed Hiperco bar. In conclusion, the effects of the resultant microstructure and texture on the coercivity and permeability magnetic properties are discussed.

36 MATERIALS SCIENCE↗

Texture Analysis of Polycrystalline Vaterite Spherulites from Lake Sturgeon Otoliths

Fish otoliths, or ear bones, are comprised of the CaCO 3 polymorphs (aragonite, calcite and vaterite), which can occur either alone or in combination. The polymorph phase abundance in an otolith depends on, as yet, unexplained genetic and environmental factors. Most fish otoliths are comprised of the densest CaCO 3 polymorph, aragonite. Sturgeon otoliths, on the other hand, contain significant amounts of the rare and the structurally enigmatic polymorph, vaterite. Sturgeon otoliths are frequently comprised of agglomerations of small microcrystalline vaterite spherulites (<300 μm in diameter), that range in shape from nearly perfect spheres to oblate spheroids. These spherulites are similar to the synthetic vaterite microspheres employed in laser trapping applications. Vaterite spherulites from both hatchery-reared (juvenile) and wild (adult) Lake Sturgeon exhibit extreme crystallographic texture as evidenced by X-ray diffraction patterns and their reconstructed pole-figures determined here. The vaterite crystallites making up the spherulites have excellent registry in both the axial and equatorial directions. Whether synthesized or natural, the texture manifested in these spherulites suggests that vaterite nucleates and grows similarly in vivo otolith formation as well as from laboratory synthesis. The uniaxial optical character of the vaterite spherulites, confirmed by these diffraction experiments and combined with their large birefringence, makes them well suited for laser trapping applications.

36 MATERIALS SCIENCE↗

Instrument and method for X-ray diffraction, fluorescence, and crystal texture analysis without sample preparation

An X-ray diffraction and X-ray fluorescence instrument for analyzing samples having no sample preparation includes a X-ray source configured to output a collimated X-ray beam comprising a continuum spectrum of X-rays to a predetermined coordinate and a photon-counting X-ray imaging spectrometer disposed to receive X-rays output from an unprepared sample disposed at the predetermined coordinate upon exposure of the unprepared sample to the collimated X-ray beam. The X-ray source and the photon-counting X-ray imaging spectrometer are arranged in a reflection geometry relative to the predetermined coordinate.

Gendreau, Keith↗