Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Test Report for the Qualification Testing of the ORNL-SFC-W-1 Special Form Capsule

Three prototypes the ORNL-SFC-W-1 special form capsules (SFCs) of the same design were evaluated to determine if the requirements of Title 49, Code of Federal Regulations (CFR), Part 173.469, Tests for Special Form Class 7 (Radioactive) Materials, were met. The results of the special form tests are documented in this test report. This report describes the special form testing activities performed on the three ORNL-SFC-W-1 capsules. The test units were designated as TU-1, TU-2 and TU-3. TU-1 was subjected to leak testing, impact testing and percussion testing. TU-1 was leak tested using the leak rate test specified in 49 CFR 173.469(a)(4)(i). The impact test was conducted according to the requirements in 49 CFR 173.469 (b)(1). The percussion test that was carried out on TU-1 was conducted in accordance with 49 CFR 173.469 (b)(2). Both TU-2 and TU-3 were subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469(b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests as specified in American National Standards Institute (ANSI) N14.5-2014.The measured leak rates were converted to standard condition leak rates as specified in American Society for Testing and Measurement (ASTM) E 493. The determined standardized leak rates obtained from the test and the calculations for all the test units met the requirements for special form certification. The testing was performed under the direction of the Oak Ridge National Laboratory (ORNL) Package Testing Program (PTP).

42 ENGINEERING↗

Test Report for the Regulatory Testing of the Welded Isotek-SFC-W-3 Special Form Capsule

Two prototypes the welded ISOTEK-SFC-W-3 special form capsules (SFCs) of the same design were evaluated to determine if the requirements of Title 49, Code of Federal Regulations (CFR), Part 173.469, Tests for Special Form Class 7 (Radioactive) Materials, were met. The results of the special form tests are documented in this test report. This report describes the special form testing activities performed on the two welded ISOTEK-SFC-W-3 capsules. The test units were designated as TU-1 and TU-2. TU-1 was subjected to leak testing, percussion testing, and impact testing. TU-1 was leak tested using the leak rate test specified in 49 CFR 173.469(a)(4)(i). The impact test on TU-1 was conducted according to the requirements in 49 CFR 173.469 (b)(1). The percussion test that was carried out on TU-1 was conducted in accordance with 49 CFR 173.469 (b)(2). TU-2 was subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469(b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests, as specified in American National Standards Institute (ANSI) N14.5-2014. The measured leak rates were converted to standard condition leak rates as specified in American Society for Testing and Measurement (ASTM) E 493. The determined standardized leak rates obtained from the test and the calculations for all the test units met the requirements for special form certification. The testing was performed under the direction of the Oak Ridge National Laboratory (ORNL) Package Testing Program (PTP).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Fano cavity test for Monte Carlo proton transport algorithms

Purpose: In the scope of reference dosimetry of radiotherapy beams, Monte Carlo (MC) simulations are widely used to compute ionization chamber dose response accurately. Uncertainties related to the transport algorithm can be verified performing self-consistency tests, i.e., the so-called “Fano cavity test.” The Fano cavity test is based on the Fano theorem, which states that under charged particle equilibrium conditions, the charged particle fluence is independent of the mass density of the media as long as the cross-sections are uniform. Such tests have not been performed yet for MC codes simulating proton transport. The objectives of this study are to design a new Fano cavity test for proton MC and to implement the methodology in two MC codes: Geant4 and PENELOPE extended to protons (PENH). Methods: The new Fano test is designed to evaluate the accuracy of proton transport. Virtual particles with an energy ofE{sub 0} and a mass macroscopic cross section of (Σ)/(ρ) are transported, having the ability to generate protons with kinetic energy E{sub 0} and to be restored after each interaction, thus providing proton equilibrium. To perform the test, the authors use a simplified simulation model and rigorously demonstrate that the computed cavity dose per incident fluence must equal (ΣE{sub 0})/(ρ) , as expected in classic Fano tests. The implementation of the test is performed in Geant4 and PENH. The geometry used for testing is a 10 × 10 cm{sup 2} parallel virtual field and a cavity (2 × 2 × 0.2 cm{sup 3} size) in a water phantom with dimensions large enough to ensure proton equilibrium. Results: For conservative user-defined simulation parameters (leading to small step sizes), both Geant4 and PENH pass the Fano cavity test within 0.1%. However, differences of 0.6% and 0.7% were observed for PENH and Geant4, respectively, using larger step sizes. For PENH, the difference is attributed to the random-hinge method that introduces an artificial energy straggling if step size is not small enough. Conclusions: Using conservative user-defined simulation parameters, both PENH and Geant4 pass the Fano cavity test for proton transport. Our methodology is applicable to any kind of charged particle, provided that the considered MC code is able to track the charged particle considered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methodology for Mechanical Property Testing on Fuel Cladding Using an Expanded Plug Wedge Test

To determine the tensile properties of irradiated fuel cladding in a hot cell, a simple test was developed at ORNL and is described fully in US Patent Application 20060070455, Expanded plug method for developing circumferential mechanical properties of tubular materials. This method is designed for testing fuel rod cladding ductility in a hot cell utilizing an expandable plug to stretch a small ring of irradiated cladding material. The specimen strain is determined using the measured diametrical expansion of the ring. This method removes many complexities associated with specimen preparation and testing. The advantages are the simplicity of measuring the test component assembly in the hot cell and the direct measurement of specimen strain. It was also found that cladding strength could be determined from the test results. The basic approach of this test method is to apply an axial compressive load to a cylindrical plug of polyurethane (or other materials) fitted inside a short ring of the test material to achieve radial expansion of the specimen. The diameter increase of the specimen is used to calculate the circumferential strain accrued during the test. The other two basic measurements are total applied load and amount of plug compression (extension). A simple procedure is used to convert the load circumferential strain data from the ring tests into material pseudo-stress-strain curves. However, several deficiencies exist in this expanded-plug loading ring test, which will impact accuracy of test results and introduce potential shear failure of the specimen due to inherited large axial compressive stress from the expansion plug test. First of all, the highly non-uniform stress and strain distribution resulted in the gage section of the clad. To ensure reliable testing and test repeatability, the potential for highly non-uniform stress distribution or displacement/strain deformation has to be eliminated at the gage section of the specimen. Second, significant compressive stresses were induced by clad bending deformation due to a clad bulging effect (or the barreling effect). The barreling effect caused very large localized shear stress in the clad and left testing material at a high risk of shear failure. The above combined effects will result in highly non-conservative predictions both in strength and ductility of the tested clad, and the associated mechanical properties as well. To overcome/mitigate the mentioned deficiencies associated with the current expansion plug test, systematic studies have been conducted. Through detailed parameter investigation on specific geometry designs, careful filtering of material for the expansion plug, as well as adding newly designed parts to the testing system, a method to reconcile the potential non-conservatism embedded in the expansion plug test system has been discovered. A modified expansion plug testing protocol has been developed based on the method. In order to closely resemble thin-wall theory, a general procedure was also developed to determine the hoop stress $\sigma_\theta$ in the tested ring specimen. A scaling factor called $\chi$-factor is defined to correlate the ring load F ring into hoop stress $\sigma_\theta$, and written as $\sigma_\theta = \chi \frac{F_{ring}} {tl}$. The generated stress-strain curve agrees very well with tensile test data in both the elastic and plastic regions.

expansion plug test↗

REGULATORY TESTING AND POSTTEST ANALYSIS OF THE DPP-3 TYPE B SHIPPING CONTAINER FOR NCT AND HAC TESTS

The safe transportation of radioactive material using appropriately designed and certified transportation packages is important to protect the public and environment. Therefore, a comprehensive and rigorous system of packaging requirements are required. The purpose of this test protocol is to determine the effects of drop testing on package performance in a Type B shipping package (DPP-3). Required physical tests for the DPP-3 package include normal conditions of transport and hypothetical accident conditions test requirements. The preparation, regulatory testing, and post-test evaluation of a Type B shipping package tested to the 10 CFR 71.71 and 10 CFR 71.73 requirements will be presented. Six packages were tested and the responses when subjected to the HAC sequence of free drop, puncture, and thermal tests according to 10 CFR 71.73 were measured. The posttest helium leak test showed a leak rate less than 1 × 10-7 He-cc/sec which means that the containment boundary was maintained after the regulatory testing, therefore maintaining a leak tight environment. To determine the amount of change in the package performance measurements, statistical analyses were conducted using SPSS version 26. The null hypothesis of the testing was that there would not be a change in the measurements from pre to post-testing large enough to find statistical significance. Therefore, a finding of statistical significance indicated too much variability in the package design and was deemed an unfavorable finding. A repeated measures t-test was used to analyze the drum lids and CV torques. A one-way ANOVA was used to analyze height and diameter packages. Results of the repeated measures t-test indicated that all six containment vessel lid torques were statistically significant. However only three out of the six drum lid torques were statistically significant. Therefore, design of the lids caused more variability than necessary when subjected to the following drop tests: 1.) horizontal and cold; 2.) vertical lid down; and 3.) corner with lid up. Results of the one-way ANOVA analysis on height indicated that four out of the six CTUs were statistically significant. Thus, design of the CTUs caused more variability then necessary when subjected to the following drop tests: 1.) horizontal hot; 2.) horizontal cold; 3.) corner lid up; and 4.) corner lid down. Results of the one-way ANOVA analysis on diameter indicated that all six CTUs were statistically significant. Thus, design of the CTUs caused more variability then necessary when subjected to all of the tests. The DPP-3 design has been shown to be an acceptable design for the transport of radioactive materials. However, results of the statistical analysis reveal a possible improvement in package and test design to reduce variability in package performance measurement before and after testing.

Martinez, Oscar↗

REGULATORY TESTING AND 3D SCANNING METHODOLOGY OF THE DPP-1 TYPE SHIPPING CONTAINER FOR NCT AND HAC TESTS

The safe transportation of radioactive material using appropriately designed and certified transportation packages is important to protect the public and environment. In the United States of America all transportation of radioactive material is regulated by the Department of Transportation (DOT) along with input by the Nuclear Regulatory Commission (NRC). All packages that contain radioactive material requires that it be transported and regulated by the requirements set by the DOT Class 7 hazardous material transportation. Federal regulations place strict administrative controls on the transport of radioactive materials. The two main goals for transporting radioactive materials are 1. Safety should be the primarily focused on the package because it is the first line of defense. 2. Package integrity should be directly related to the degree of the hazard of the radioactive material contents. The two-part goal ensures that the right package is used. Type B packages are designed to transport radioactive materials with the highest level of radioactivity. Examples of material transported in Type B packagings include spent nuclear fuel, high-level radioactive waste, and high concentrations of other radioactive materials. The purpose of this test protocol is to determine the effects of drop and thermal testing on package performance in a Type B shipping package (DPP-1). Required physical tests for the DPP-1 package include free drop, crush, puncture, penetration, compression, vibration, water spray, water immersion, and thermal. The preparation, regulatory testing, and post-test evaluation of a Type B shipping package tested to the 10 CFR 71.71 and 10 CFR 71.73 requirements will be presented. Six packages were tested and the responses when subjected to the HAC sequence of free drop, puncture, and thermal tests according to 10 CFR 71.73(c)(1), (c)(2), (c)(3) and (c)(4) were measured. The Free Drop, Crush and Puncture tests were performed at the NTRC in Knoxville, TN, and the Thermal tests were performed Southwest Research Institute in San Antonio, TX. The test units were subjected to a pre-operational leak testing before the NCT and HAC tests and a post-operational leak test and a helium leak test once regulatory testing was complete. Finally, all test units were scanned with a handheld blue light scanner to capture a 3D CAD geometry of the test units in the deformed shape. The handheld scanner provided the most effective and reliable way to acquire accurate 3D measurements of the test unit. The scanned geometry was sectioned in areas with deformation and the cross-section profile was measured to determine accurate and repeatable results of the deformed shape of the test units.

Martinez, Oscar↗

Computer Codes V and V Tests with a Large-Scale Sodium Thermal-Hydraulic Test Facility (STELLA)

The Korea Atomic Energy Research Institute (KAERI) is carrying out the design of a 'Prototype Generation IV Sodium-cooled Fast Reactor (PGSFR)' in cooperation with Argonne National Laboratory (ANL) in the US. In regard to computer codes V and V, a large-scale sodium thermal-hydraulic test program is currently being progressed in parallel with the PGSFR design, which is called STELLA (Sodium Test Loop for Safety Simulation and Assessment). The final objective of this program is to collect a separate and integral effect test database to validate the safety analysis codes and other thermal hydraulic design codes. In the first phase of the STELLA program, the sodium component test loop (hereafter called STELLA-1) was constructed at the KAERI site, and it has been used for performance tests of key sodium heat exchangers in PGSFR. Since this sodium test loop is basically for separate effects tests to verify the performance of key sodium components, the test database obtained from STELLA-1 has been used for the V and V of safety codes as well as heat exchanger design codes. The second phase of the program aiming at an integral effect test is called STELLA-2, which will be used for synthetic review of the key safety issues of PGSFR. The basic and detailed design phases of the STELLA-2 test facility are underway in accordance with the specific design requirements reflecting the whole design features of PGSFR. The facility installation is scheduled to be completed by 2018. Then the main experiments including the start-up tests will begin and the first integral effect test database will be constructed by the end of 2019. Based on the STELLA-2 platform, a simulation of the PGSFR transient will be made to evaluate the plant dynamic behaviors and demonstrate the decay heat removal performance. Multi-dimensional effects coming from a large sodium pool system will be identified as well. The test database obtained from the STELLA-2 experiment will be used for the validation of the safety analysis codes and other thermal hydraulics codes, and this project finally contributes to the specific design phase of PGSFR. This paper presents both the results of heat transfer tests for the key sodium heat exchangers using STELLA-1 and the first results of heat exchanger design codes V and V. The recent progress of the engineering design for the STELLA-2 test section is introduced and its specific design parameters are also presented in this paper with detailed evaluation results of their scaling distortions. A large-scale sodium thermal-hydraulic test program (STELLA) was introduced with the specific activities for separate and integral effects tests. The test database obtained from STELLA-1 was successfully used to validate both the heat exchanger design and safety analysis codes. Specific design features of the integral effects test facility (STELLA- 2) with a scaling ratio of 1/5 in length and 1/125 in volume were also presented. Validation of the STELLA-2 facility design is underway using system codes and CFD tools. Dedicated water-mockup experiments to verify the scaling design of key subsystems are currently being conducted as well. (authors)

42 ENGINEERING↗

Utah FORGE 2439: Well 16B(78)-32 Field-Test Data from Mini-Frac Tests

This submittal includes the field-test data collected during stress tests conducted in the Utah FORGE 16B(78)-32 wellbore to measure/characterize the stresses in the geothermal reservoir. The type of stress test performed is referred to as a mini-frac test or a micro-frac test. The test is a hydraulic fracture test that involves injecting a small volume of water into a short interval of the reservoir that is isolated by a straddle packer to create a fracture. The test provides information about the minimum and maximum horizontal stress at the test depths. A total of seven mini-frac tests were performed within the upper (vertical or nearly vertical) section of the 9-5/8-inch diameter uncased wellbore, between depths of 5,202 ft MD [5,202 ft TVD] and 5,980 ft MD [5966.18 ft TVD]. Two types of data were generated as part of the mini-frac tests. The first type of data is time-series data for each mini-frac test (e.g., injection-rate, test-interval pressure), and are contained in the "Mini-Frac Test Data.zip" file below. The second type is geophysical log data, attached below in the "Geophysical Logs.zip" file. Here, two types of image logs and acoustic logs were obtained before and after the mini-frac tests to examine each test depth for visual evidence of induced fracture(s) and to measure the azimuth (orientation) of any observed fractures. The attached Readme file includes the test depth information and contents of each data file included here. Analysis of the field-test data was conducted and is documented in the attached report below.

15 GEOTHERMAL ENERGY↗

Field Testing of a Wet FGD Additive for Enhanced Mercury Control - Task 5 Full-Scale Test Results

This Topical Report summarizes progress on Cooperative Agreement DE-FC26-04NT42309, 'Field Testing of a Wet FGD Additive'. The objective of the project is to demonstrate the use of two flue gas desulfurization (FGD) additives, Evonik Degussa Corporation's TMT-15 and Nalco Company's Nalco 8034, to prevent the re-emission of elemental mercury (Hg{sup 0}) in flue gas exiting wet FGD systems on coal-fired boilers. Furthermore, the project intends to demonstrate whether the additive can be used to precipitate most of the mercury (Hg) removed in the wet FGD system as a fine salt that can be separated from the FGD liquor and bulk solid byproducts for separate disposal. The project is conducting pilot- and full-scale tests of the additives in wet FGD absorbers. The tests are intended to determine required additive dosages to prevent Hg{sup 0} re-emissions and to separate mercury from the normal FGD byproducts for three coal types: Texas lignite/Powder River Basin (PRB) coal blend, high-sulfur Eastern bituminous coal, and low-sulfur Eastern bituminous coal. The project team consists of URS Group, Inc., EPRI, Luminant Power (was TXU Generation Company LP), Southern Company, IPL (an AES company), Evonik Degussa Corporation and the Nalco Company. Luminant Power has provided the Texas lignite/PRB co-fired test site for pilot FGD tests and cost sharing. Southern Company has provided the low-sulfur Eastern bituminous coal host site for wet scrubbing tests, as well as the pilot- and full-scale jet bubbling reactor (JBR) FGD systems tested. IPL provided the high-sulfur Eastern bituminous coal full-scale FGD test site and cost sharing. Evonik Degussa Corporation is providing the TMT-15 additive, and the Nalco Company is providing the Nalco 8034 additive. Both companies are also supplying technical support to the test program as in-kind cost sharing. The project is being conducted in six tasks. Of the six project tasks, Task 1 involves project planning and Task 6 involves management and reporting. The other four tasks involve field testing on FGD systems, either at pilot or full scale. The four tasks include: Task 2 - Pilot Additive Testing in Texas Lignite Flue Gas; Task 3 - Full-scale FGD Additive Testing in High-sulfur Eastern Bituminous Flue Gas; Task 4 - Pilot Wet Scrubber Additive Tests at Plant Yates; and Task 5 - Full-scale Additive Tests at Plant Yates. The pilot-scale tests and the full-scale test using high-sulfur coal were completed in 2005 and 2006 and have been previously reported. This topical report presents the results from the Task 5 full-scale additive tests, conducted at Southern Company's Plant Yates Unit 1. Both additives were tested there.

01 COAL, LIGNITE, AND PEAT↗

Aftertreatment protocols for catalyst characterization and performance evaluation: low-temperature oxidation, storage, three-way, and NH3-SCR catalyst test protocols

A set of standardized and realistic aftertreatment catalyst test protocols have been developed by the Advanced Combustion and Emission Control Technical Team in support of the U.S.DRIVE Partnership. The protocols are intended to accelerate the pace of aftertreatment catalyst innovation by enabling the accurate evaluation and comparison of aftertreatment catalyst performance data from various testing and research facilities to maximize the impact of discovery-phase research occurring across the nation. The protocols address a need identified by the Partnership’s industry partners for consistent and accurate metrics for aftertreatment catalyst evaluation and comparison. The protocols consist of a set of standardized requirements and test procedures that sufficiently capture the performance capability of a catalyst technology in a manner that is adaptable in various laboratories. The protocols provide a detailed description of the necessary reactor system, the steps for achieving a desired aged state of the catalyst, all necessary sample pretreatment to be performed prior to testing, and realistic test conditions for evaluating performance. This article details four low-temperature catalyst test protocols applicable to (1) oxidation catalysts, (2) passive storage (and release) catalysts, (3) three-way catalysts, and (4) NH3-SCR catalysts. The catalyst test protocol descriptions are presented in five (5) sections: protocol general guidelines and the four individual catalyst test protocol descriptions. The general guidelines plus the individual protocol description forms the complete low-temperature catalyst test protocol for the application.

Emission control, Three-way catalyst, oxidation, S↗

Test Report of Special Form Qualification Testing for the ORNL U ZipCan

This test report describes the special form testing activities performed on the two ZiPCans. One prototype test unit was subjected to the tests stipulated by 10 CFR 71.75 (d)(1)(i), ISO 2919:1999(E) Class 4 impact test, along with the leak rate test specified in 49 CFR 173.469(a)(4)(i). The other test unit was subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469 (b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests, as specified in ANSI N14.5-2014.The measured leak rates were converted to standard condition leak rates as specified in ASTM E 493. The determined standardized leak rates from the test and calculation for both test units met the requirements for special form certification.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mechanisms Engineering Test Loop (METL) Operations, Maintenance, and Testing - FY2025

This report documents the operations, maintenance, and improvements that were performed at the Mechanisms Engineering Test Loop (METL) and its supporting infrastructure during FY2024. The METL facility had a very successful seventh year of operations while supporting the testing of multiple test article experiments in the facility. The METL facility continued supporting the Gear Test Assembly (GTA) testing and the Thermal Hydraulic Experimental Test Article (THETA) with the full testing with both the primary and secondary systems. Work to accommodate two additional experiments, a flow sensor test article (F-STAr) gripper test and a fuel handling gripper test article (GrTA) continued as they are expected to undergo testing in METL in FY2025. In addition, a new 18” test article, the Sample Testing Basket (STB) was used a few times to provide screening tests for sodium service materials. A fifth test vessel was installed in the location of Test Vessel 6, and a wet vapor nitrogen sodium processing system was developed and initially tested.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of a Test Article and Test Facility to Investigate Flow-Induced Vibration of a Helical Coil Steam Generator

NuScale Power LLC (NuScale) is developing a small modular reactor (SMR) with unique design features and arrangements that require testing to provide quality data for safety analysis codes and design validation, as well as for technology maturation. A multi-phase testing program is underway at NuScale to demonstrate that its unique helical coil steam generator design is not susceptible to flow-induced vibration during operation. The phases of the testing program include modal testing of individual tubes during test article fabrication and modal and flow testing after test article completion. NuScale has contracted SIET S.p.A. in Piacenza, Italy for the design and fabrication of the test article and test facility. In-fabrication testing was performed at the site of test article build in Cremosano, Italy. Modal testing and flow testing of the completed test article will be performed at SIET’s facilities in Piacenza. This paper discusses the design of the test article and test facility, including supporting systems, required to generate the quality data required to support NuScale’s comprehensive vibration assessment program as part of the overall licensing effort for NuScale’s first-of-a-kind small modular light water reactor.

Flow-induced vibration, helical coil, steam genera↗

Advanced Test Reactor Mini-Plate Hydraulic Testing

Currently, flow testing is being performed at Oregon State University (OSU) on the hydromechanical Fuel Test Facility (HMFTF) and the Endurance Flow Loop (EFL) to aid in the qualification of low enriched plate-type Uranium fuels for use in high performance research reactors in the US, under the Global Threat Reduction Initiative (GTRI). Under this project, varying geometries of small capsules proposed for irradiation testing in the Advanced Test Reactor (ATR) are being hydraulically testing prior to being placed in the ATR. The premise of this study was to conduct a number of flow tests on these capsules to characterize the pressure loss through each as a function of flow rate and compare the results against predicted theoretical values. Two categories of flow tests were performed in the Endurance Flow Loop to supplement flow testing of proposed LEU plate-type fuel for conversion of High Performance Research Reactors: Capsule Comparison Tests and Orifice Characterization Tests. The purpose of these tests were to determine the pressure drop across each experiment as a function of flow rate and to compare the results against a simple analytical model of the pressure loss through a pipe, to support the safety basis for the in-pile experiments. The capsule comparison tests compared the pressure loss through three types of capsules: RERTR, MP-1, and EMPIRE. In this category, nine flow tests were performed to determine the effect of having one, two, and three of each type of capsule placed in series in a test section. The analytical model accurately predicted, for each case, an increase in hydraulic resistance for each capsule that was added, though the values were conservative. The orifice characterization tests compared the pressure loss through various configurations of small orifice spacers in conjunction with blank spacers and the MP-1 capsules. The analytical model predicted that adding blank spacers would slightly increase the pressure drop due to added frictional effects, but indicated no change in the pressure drop based on the orientation of the capsules. The measured results indicated that the addition of the blank spacers had no measurable effect on the pressure drop, while changing the orientation of the capsules did. In all 15 flow tests, the theoretical model provides a conservative estimate of the pressure drop through each configuration for an equivalent flow rate, over that of the measured results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Estimation of the two-dimensional presampled modulation transfer function of digital radiography devices using one-dimensional test objects

Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Methods: Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ/i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the 1D edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. Results: The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm{sup -1}) and approximate circular symmetry at frequencies below 4 mm{sup -1}. While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm{sup -1}. Slit measurement near 45 Degree-Sign revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm Multiplication-Sign 0.2 mm), a characteristic which was not necessarily appreciated with the orthogonal 1D MTF measurements. In simulation experiments, both slit- and edge-based measurements resolved the radial asymmetries in the 2D MTF. The average absolute relative accuracy error in the 2D MTF between the DC and cutoff (2.5 mm{sup -1}) frequencies was 0.13% with average relative precision error of 0.11%. Other simulation results were similar to those derived from physical data. Conclusions: Overall, the general availability, acceptance, accuracy, and ease of implementation of 1D test devices for MTF assessment make this a valuable technique for 2D MTF estimation.

60 APPLIED LIFE SCIENCES↗

OECD MCCI Project Small-Scale Water Ingression and Crust Strength Tests (SSWICS) SSWICS-10 Test Data Report (Thermal Hydraulic Results)

The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These experiments provided unique, and for the most part repeatable, indications of heat transfer mechanisms that could provide long term debris cooling. However, the results did not demonstrate definitively that a melt would always be completely quenched. This was due at least partially to the fact that the crust anchored to the test section sidewalls in every test, which led to melt/crust separation, even at the largest test section lateral span of 1.2 m. This decoupling is not expected for a typical reactor cavity where the lateral span is much larger, ~5-6 m. Instead, the crust is expected to fracture under the weight of the coolant and the crust itself so that coolant contact with the melt is maintained. However, because of a lack of knowledge of the strength of the crust, one cannot be certain that it would actually fracture under such circumstances. As part of the MCCI-1 and MCCI-2 programs, a series of separate-effects experiments has been conducted to measure corium quench rates and crust strength to investigate the various debris cooling mechanisms identified in the MACE program. Each quench test involved cooling a molten mass of UO 2 , ZrO 2 , and concrete constituents, which produced a corium ingot that was later load tested to determine its mechanical strength. The quench tests were designed to optimize measurements of heat flux from the corium surface and consequently the ingots that were formed were not of optimal thickness for the strength measurements. For the quench tests, a minimum corium depth of 150 mm was deemed necessary to obtain a satisfactory heat flux measurement. However, 150 mm is too much for optimal load testing and so the ingots were sectioned (cut in the radial direction) to increase their aspect ratio (diameter/thickness) to make them more suitable for load testing. Unfortunately, the cutting process is laborious and involves much handling of the ingot and therefore decreases the certainty that the mechanical strength of the sections is close to that of the original ingot. This uncertainty would be eliminated if the ingots produced by the quench tests could be tested without having to cut them. SSWICS-9 & 10, in contrast to previous tests, are designed to optimize the ingot for load testing. A reduced amount of corium will be used in the quench test to produce a thinner ingot. The ingot will then be load tested without sectioning. This report details the results of the SSWICS-10 quench test.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

OECD MCCI Project: Small-Scale Water Ingression and Crust Strength Tests (SSWICS), SSWICS-9 Test Data Report (Thermal Hydraulic Results)

The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These experiments provided unique, and for the most part repeatable, indications of heat transfer mechanisms that could provide long term debris cooling. However, the results did not demonstrate definitively that a melt would always be completely quenched. This was due at least partially to the fact that the crust anchored to the test section sidewalls in every test, which led to melt/crust separation, even at the largest test section lateral span of 1.2 m. This decoupling is not expected for a typical reactor cavity where the lateral span is much larger, ~5-6 m. Instead, the crust is expected to fracture under the weight of the coolant and the crust itself so that coolant contact with the melt is maintained. However, because of a lack of knowledge of the strength of the crust, one cannot be certain that it would actually fracture under such circumstances. As part of the MCCI-1 and MCCI-2 programs, a series of separate-effects experiments has been conducted to measure corium quench rates and crust strength to investigate the various debris cooling mechanisms identified in the MACE program. Each quench test involved cooling a molten mass of UO 2 , ZrO 2 , and concrete constituents, which produced a corium ingot that was later load tested to determine its mechanical strength. The quench tests were designed to optimize measurements of heat flux from the corium surface and consequently the ingots that were formed were not of optimal thickness for the strength measurements. For the quench tests, a minimum corium depth of 150 mm was deemed necessary to obtain a satisfactory heat flux measurement. However, 150 mm is too much for optimal load testing and so the ingots were sectioned (cut in the radial direction) to increase their aspect ratio (diameter/thickness) to make them more suitable for load testing. Unfortunately, the cutting process is laborious and involves much handling of the ingot and therefore decreases the certainty that the mechanical strength of the sections is close to that of the original ingot. This uncertainty would be eliminated if the ingots produced by the quench tests could be tested without having to cut them. SSWICS-9 & 10, in contrast to previous tests, are designed to optimize the ingot for load testing. A reduced amount of corium will be used in the quench test to produce a thinner ingot. The ingot will then be load tested without sectioning. This report details the results of the SSWICS-9 quench test.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗