Pulsed Radiation Environments for Effects Testing and Validation.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Phases by definition in an alloy system have distinct physical and chemical properties, including thermal conductivity. The goal of this multi-year study is to show that the different phases present in the U-Zr system indeed do have different thermal conductivities. This study will provide meso-scale (10-100 µm) experimental observations using the Thermal Conductivity Microscope (TCM) of phase dependent thermal conductivity. The results of this study may indicate the need to reconsider the application of homogeneous medium assumption for metallic nuclear fuel that is currently used in fuel performance modeling, and could provide input for improving such model using a heterogeneous phase dependent assessment of thermal properties. The local thermal conductivity values from the TCM will be compared to the bulk measurements to validate this work. Twelve alloy samples with varying Zr compositions and heat treatments were fabricated for the initial phase of this study to characterize the individual phases present in the U-Zr system. The gamma body-centered cubic (BCC) phase was successfully identified in the appropriate size for TCM measurement. Next steps in this work will include identification of remaining phases in the U-Zr alloy system. Thermal conductivity will be measured in those phase areas of the materials and used to assess fuel performance codes for improvements.
Explore the source record for details and available documents.
No Abstract, slides Only
NA: This is a yearly progress summary presentation describing progress to date on an NSUF funded irradiation test series meant to evaluate the performance of sapphire optical fiber sensors.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A recently completed LDRD project has provided a new facility at Sandia for testing effects of energetic neutrons on electronic components. 14 MeV neutrons are produced with a deuterium ion beam onto a thin-film tritide target. The goal of the project was to increase the neutron fluence to levels needed for radiation effects testing and qualification. This goal was achieved through two technical advances. First, a new multi-layer target concept was developed to reduce the rate of tritium loss from the target by isotope exchange, thereby reducing tritium usage and increasing target lifetime. The second advance was the construction of a new test chamber designed to maximize neutron flux at test locations. Together, these increased the available neutron fluence by several orders of magnitude. This new capability is being used in tests for Sandia nuclear weapon programs, evaluation of commercial parts such as highly-scaled CMOS SRAM lCs, and tests of new devices under development at Sandia such as lll-V HBTs, gallium nitride high-voltage diodes, and for fundamental studies of physical mechanisms of device failure.
In this project, Building America research team Building Science Corporation tested the effectiveness of ventilation systems at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. This was because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four system factor categories: balance, distribution, outside air source, and recirculation filtration. Recommended system factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $\$$50-$\$$75/year.
RELAP5-3D is the premier systems thermal-hydraulic code in the world. The code has been used significantly for high-temperature gas-cooled reactor (HTGR) analyses over the last 10 years, but there has not been a comprehensive summary of RELAP5-3D capabilities and methods for HTGR modeling. In this paper, we provide a guide for how novice users can build models for prismatic HTGRs. This guide includes best practices for developing heat structures and setting up radiation and conduction heat transfer. We also provide a summary of relevant validation studies. These studies are divided into three categories: separate effects tests, integral effects tests, and nuclear reactor studies. We present a comprehensive review of RELAP5-3D HTGR applications for reactor modeling over the last 10 years. These applications include work for the Modular High-Temperature Gas-Cooled Reactor benchmark, design activities for a prismatic HTGR as part of the U.S. Department of Energy’s Advanced Demonstration and Test Reactor Options Study, and studies performed to design gas-cooled microreactors. Following the comprehensive literature review, we present a gap analysis highlighting capabilities of RELAP5-3D that are available and missing for a complete analysis of HTGR thermal hydraulics. We also discuss the limitations of existing code capabilities and potential improvements that could improve analyses. Current research efforts have yet to fully validate RELAP5-3D for a prismatic HTGR analysis; however, some of this is attributable to confounding factors in the available experimental data as opposed to code capabilities. In conclusion, this paper presents the most comprehensive review to date on RELAP5-3D capabilities, limitations, and applications for HTGR analysis.
A scaling analysis is essential for predicting the behavior of a reactor system under various operating conditions, as well as for ensuring safe and reliable experimentation and adequate dataset generation for supporting the system code model development and assessment in accordance with USNRC guidelines 1.203. Testing and modeling can be carried out at various scales, from small test units to full-scale reactors, to validate the predictions produced by the analysis. However, due to the cost and challenges associated with full-scale testing, the nuclear industry uses scaled test facilities—integral effect test (IET) and separate effect test (SET)—to identify potential design issues and optimize the design to ensure regulatory compliance for safer operation and anticipated accident management. In general, IET facilities are non-nuclear thermal hydraulics test facilities. In contrast, SET facilities can be non-nuclear testing (e.g., steam generator, containment, pump system SETs) and nuclear testing (mostly fuel-material irradiation testing). IETs are used to study the system-level thermal-hydraulic behavior of the reactor coolant system (RCS) under different anticipated operational occurrences (AOOs) and design basis accidents (DBAs) such as loss-of-coolant-accident (LOCA) and loss-of-power (i.e., station blackout) and loss-of-flow (i.e., failure of RCS pump). Several LOCA scenarios could happen in reactor DBAs, such as main steam line break (MSLB), SG tube rapture (SGTR), break in direct vessel injection (DVI), and other small breaks LOCA. Scaling analysis determines the appropriate size and operating conditions for the test facility. This involves analyzing the system's thermal-hydraulic behavior at different scales and identifying the key parameters that affect the thermal-hydraulic behavior of the reactor. These key parameters can be identified so that the scaled facility can replicate the expected conditions in a prototypical setting. The scaled facility can simulate the same flow rates, pressure gradients, heat transfer coefficients, and fluid properties as the prototype. Scaling analysis is used to ensure that the results from these tests can be scaled up to predict the behavior of a full-scale prototype with an acceptable range of scaling distortions.
Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs.
Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. It was inferior because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.
?Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy.
Abstract not provided
We report that qualification of new nuclear fuels is necessary for their deployment and requires a thorough understanding of fuel behavior under irradiation. Traditionally, nuclear fuels have been qualified by performing exhaustive integral tests under a limited range of prototypic conditions designed for their specific reactor application. While some integral fuel testing is essential, basic data on behavior and property evolution under irradiation can be obtained from separate effects tests. These irradiations could offer reduced cost, reduced complexity, and in the case of accelerated testing, reduced time to achieve a given burnup. Furthermore, it may be desirable to design test irradiations capable of deconvoluting the myriad effects of burnup, temperature gradients, and other factors inherent to integral irradiation tests. Oak Ridge National Laboratory has developed an experimental capability to perform separate effects irradiation testing of miniature fuel specimens in the High Flux Isotope Reactor (HFIR): the “MiniFuel” irradiation vehicle. The small size (<4 mm 3 ) of the fuel specimens simplifies the design, analysis, and post-irradiation examination. By reducing the fuel mass, the total heat generated inside the experiment vehicle can be dominated by gamma heating in the structural materials instead of fission heating in the fuel. This essentially decouples the fuel temperature from the fission rate, allowing for highly accelerated testing (3X-18X the burnup rate of a typical light water reactor for 235 U enrichments varying from 0.22 wt% to 8 wt%) and an extremely flexible experiment design that can accommodate a wide range of fuel temperatures (~100 °C to >1200 °C), compositions, enrichments, and even geometries without requiring detailed analyses for each fuel variant. In conclusion, this paper summarizes the experiment design concept, evaluates potential applications for specific fuel forms, and briefly describes the first set of experiments on uranium nitride kernels that have been assembled and are currently being irradiated in the HFIR.
This document outlines a strategic plan for a safety research program for accident tolerant fuels. Accident tolerant fuels (ATFs) are nuclear fuel materials and designs for existing and future light water reactors. This effort is under the Department of Energy Office of Nuclear Energy’s Nuclear Technology Research and Development Advanced Fuels Campaign. The development of ATF is an industry lead initiative with fuel designs being championed by Westinghouse, Framatome, and General Electric. Industry goals for ATF deployment include implementing the first batch reloads of coated cladding and doped fuel designs into commercial reactors by 2023 and having the first batch reloads of more advanced designs into commercial reactors by 2026. Follow on goals include implementing the first full cores of coated cladding and doped fuel designs into commercial reactors by 2026 and implementing full cores of more advanced designs by 2030. The objectives of the national laboratory research programs within the Advanced Fuels Campaign related to ATF are: 1. Develop and maintain of unique nuclear testing infrastructure, which includes test reactors, hot cell PIE equipment, and unique out of pile separate effects testing facilities. 2. Respond directly to industry requests for support by partnering with the ATF vendors and executing experiments and/or analysis on their behalf. 3. Conduct independent scientific investigations into the performance of the different ATF concepts that are relevant to Industry designs. To achieve these objectives, the safety research program will execute transient irradiation experiments at the TREAT facility at Idaho National Laboratory with the aim of identifying the relevant transient fuel behaviors for each fuel design in order to establish appropriate fuel safety criteria and thresholds. Two test series are described in this plan, (1) an Integral Test Series, and (2) a Focused Effects Test Series. In fulfillment of the first objective for the safety research program, Integral Effects Tests will be developed and demonstrated using standard UO2 Zircaloy fuel designs in both the fresh and previously irradiated case. The Integral Test Series will consist of three campaigns to evaluate transient fuel performance in Reactivity Initiated Accidents, Loss of Coolant Accidents, and in generalized Power Cooling Mismatch scenarios. Development of these test programs also enables the safety research program to fulfill its second objective by making these three test programs available to each industry team. Initially, priority will be given in the integral test series to the coated cladding and doped fuel concepts as their deployment schedule is the most aggressive. To fulfill the third objective of the safety research program, a Focused Effects Test Series is also being developed which will examine specific transient fuel behaviors that are of general interest to all the ATF designs under development. These tests look at transient fuel behavior related to pellet cladding mechanical interaction, coated cladding swelling, rupture, and time at temperature behavior, non oxide fuel melting and mechanical interaction with Silicon Carbide cladding, UO2 and doped UO2 fuel fragmentation and transient fission gas release, and finally fuel coolant interaction. This document provides a general overview of the objectives of the safety research program as well as providing background into how programs like this have been used in the past to develop the criteria necessary for the safe operation of the present fuel designs. An overview of the materials and methods used for safety testing is presented. Finally the Integral and Focused Effects tests series are introduced and described. This document will be maintained as a “living” document with annual updates to reflect evolving requirements and needs.
The two-phase two-fluid model is a basis of many thermal-hydraulics codes used in design, licensing, and safety considerations of nuclear power plants. Thermal-hydraulics codes rely on the closure laws to close the system of conservation equations and describe the interactions between phases. These laws, derived from years of experimental investigations, are semi-empirical correlations that lack generality and have a limited range of applicability. Increase of computational power, availability of new experiments, and development of high-fidelity simulations has increased the number of validation data. The discrepancies between the code predictions and the validation data are a great source of knowledge. Missing physics that are not included in the model but are important for the considered phenomena can be discovered by propagating the information from the experimental results through the model. Furthermore, physics-discovered data-driven model form (P3DM) methodology integrates available integral effect tests and separate effects tests to determine the necessary corrections to the model form of the closure laws. In contrast to existing calibration techniques, the methodology modifies the functional form of the closure laws. Based on the functional form of the correction, the missing physics that were not included in the original model can be discovered. The methodology provides the alternative to the machine learning approach, in which the model is discovered in the form of the intractable black-box relation. In this work, the methodology was applied to the CTF subchannel code to improve the prediction of the two-phase flow phenomena.