Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Multichannel temperature control for solar heating

Multiplexer/amplifier circuit monitors temperatures and temperature differences. Although primarily designed for cycle control in solar-heating systems, it can also measure temperatures in motors, ovens, electronic hardware, and other equipment.

Currie, J. R.↗

Near-Field Passive Wireless Sensor for High-Temperature Metal Corrosion Monitoring

This work focuses on the fabrication and evaluation of a passive wireless sensor for the monitoring of the temperature and corrosion of a metal material at high temperatures. An inductor–capacitor (LC) resonator sensor was fabricated through the screen printing of Ag-based inks on dense polycrystalline Al 2 O 3 substrates. The LC design was modeled using the ANSYS HFSS modeling package, with the LC passive wireless sensors operating at frequencies from 70 to 100 MHz. The wireless response of the LC was interrogated and received by a radio frequency signal generator and spectrum analyzer at temperatures from 50 to 800 °C in real time. The corrosion kinetics of the Cu 110 was characterized through thermogravimetric (TGA) analysis and microscopy images, and the oxide thickness growth was then correlated to the wireless sensor signal under isothermal conditions at 800 °C. The results showed that the wireless signal was consistent with the corrosion kinetics and temperature, indicating that these two characteristics can be further deconvoluted in the future. In addition, the sensor also showed a magnitude- and frequency-dependent response to crack/spallation events in the oxide corrosion layer, permitting the in situ wireless identification of these catastrophic events on the metal surface at high temperatures.

36 MATERIALS SCIENCE↗

Thermally Conductive Fluid Compatible With Hypergols

Proposed thermally conductive fluid thermally couples temperature probe to dry well to monitor temperature of hypergolic fluids. Chemically inert in its intended environment, has terrestrial applications in some organic-chemical synthesis processes.

Kurtz, Gary W.↗

Programmable Thermostats for MPLM Shell Heater Control ULF1: Thermal Performances - 1

The Multi-Purpose Logistics Module (MPLM) is the primary carrier for "pressurized" logistics to and from the International Space Station (ISS). The MPLM is transported in the payload bay of the Space Shuttle and is docked to the ISS for unloading, and reloading, of contents within the ISS shirt sleeve environment. Foil heaters, controlled originally with bi-metallic thermostats, are distributed across the outside of the MPLM structure and are utilized to provide energy to the structure to avoid exposure to cold temperatures and prevent condensation. The existing bi-metallic, fixed temperature set point thermostats have been replaced with Programmable Thermostats Modules (PTMs) in the Passive Thermal Control Subsystem (PTCS) 28Vdc shell heater circuits. The goal of using the PTM thermostat is to improve operational efficiency of the MPLM on-orbit shell heaters by providing better shell temperature control via feedback control capability. Each heater circuit contains a programmable thermostat connected to an external temperature sensor, a Resistive Temperature Device (RTD), which is used to provide continuous temperature monitoring capability. Each thermostat has programmable temperature set points and control spans. The data acquisition system uses a standard RS-485 serial interface communications cable to provide digital control capability. The PTM system was designed by MSFC, relying upon ALTEC support for their integration within the MPLM system design, while KSC performed the installation and ground checkout testing of the thermostat and RS-485 communication cable on the MPLM FM1 flight module. The PTMs were used for the first time during the STS-121/ULF1.1 mission. This paper will describe the design, development and verification of the PTM system, as well as the PTM flight performance and comparisons with SINDA thermal model predictions.

Glasgow, Shaun↗

Device Would Monitor Body Parameters Continuously

Proposed miniature electronic circuit continuously measures temperature of human subject. Once mounted on subject's skin with medical adhesive tape, electronic thermometer remains in thermal equilibrium with subject's body; thereafter, no need to wait until thermometer reaches body temperature before taking reading. Design provides for switches used to set alarm alerting medical attendants if subject's temperature exceeds critical level. For use on very young child, electronic thermometer sewed into shirt or other suitable garment; device held in contact with skin, and child could not swallow it. Replacement of sensor and computing algorithm changes temperature monitor to cardiorespiratory monitor.

Cook, Joseph S., Jr.↗

Cryo-Temp Data Logger

Biological experiments on the ISS are frequently frozen at ultra-low temperatures on orbit prior to return to Earth for analysis. Recording temperatures during the freezing process, and subsequent handling to the point of post-flight processing, can provide important information of sample integrity to the scientist. The MadgeTech Cryo-Temp Data Logger has been modified for space flight applications by the Payload Development Team at Kennedy Space Center. This ultra-low temperature data logger is rated for temperatures from -86 C to +35 C with 0.1 C resolution and +/-1 C accuracy, but has been successfully tested at Kennedy Space Centers Cryogenic Lab down to -100 C. The logger provides date and time stamped temperature recordings and can be set with logging intervals from 5 seconds up to 30 minutes using the MadgeTech Data Logger Software. Data can be recorded, depending on logging interval, for greater than 90 days. The Cryo-Temp Data logger will first be flown on Space X-12 in the BRIC-Petri Dish Fixation Unit (PDFU) canister hardware, recording temperature data for a Space Life and Physical Sciences (SLPS) flight experiment. The modified Cryo-Temp Data Logger is small in size (Figure 1) and is the ideal temperature monitoring solution for any application involving independent temperature data logging.

Logger↗

Bonded Invar Clip Removal Using Foil Heaters

A new process uses local heating and temperature monitoring to soften the adhesive under Invar clips enough that they can be removed without damaging the composite underneath or other nearby bonds. Two 1x1 in. (approx.2.5x2.5 cm), 10-W/sq in. (approx.1.6-W/sq cm), 80-ohm resistive foil Kapton foil heaters, with pressure-sensitive acrylic adhesive backing, are wired in parallel to a 50-V, 1-A limited power supply. At 1 A, 40 W are applied to the heater pair. The temperature is monitored in the clip radius and inside the tube, using a dual thermocouple readout. Several layers of aluminum foil are used to speed the heat up, allowing clips to be removed in less than five minutes. The very local heating via the foil heaters allows good access for clip removal and protects all underlying and adjacent materials.

Pontius, James T.↗

Multichannel temperature sensor

Simple inexpensive temperature-to-frequency converter utilizes readily available and inexpensive components to monitor temperature at eight or more locations. Circuit has potential applicability in monitoring and controlling solar energy systems, as well as other data collection and temperature control situations.

Kadrmas, K. A.↗

An inductively powered telemetry system for temperature, EKG, and activity monitoring

An implant telemetry system for the simultaneous monitoring of temperature, activity, and EKG from small animals, such as rats, was designed with the feature that instead of a battery the system is energized by an inductive field. A 250 kHz resonant coil surrounds the cage (30 x 30 x 20 cm) and provides the approximately 100 microns of power required to operate the implant transmitter while allowing the animal unrestrained movement in the cage. The implant can also be battery operated if desired. RF transmission is in the 8-10 MHz band, which allows the use of a simple, essentially single IC chip, receiver.

Fryer, T. B.↗

An inductively powered telemetry system for temperature, EKG, and activity monitoring

An implant telemetry system for the simultaneous monitoring of temperature, activity, and EKG from small animals, such as rats, has recently been designed with the novel feature that instead of a battery the system is energized by an inductive field. A 250 kHz resonant coil surrounds the cage (30 x 30 x 20 cm) and provides the approximately 100 microwatt of power required to operate the implant transmitter while allowing the animal unrestrained movement in the cage. The implant can also be battery operated if desired. RF transmission is in the 8-10 MHz band, which allows the use of a simple, essentially single IC chip, receiver.

Fryer, T. B.↗

Material Testing Device

Small Business Innovation Research (SBIR) contracts led to two commercial instruments and a new subsidiary for Physical Sciences, Inc. (PSI). The FAST system, originally developed for testing the effect of space environment on materials, is now sold commercially for use in aging certification of materials intended for orbital operation. The Optical Temperature Monitor was designed for precise measurement of high temperatures on certain materials to be manufactured in space. The original research was extended to the development of a commercial instrument that measures and controls fuel gas temperatures in industrial boilers. PSI created PSI Environmental Instruments to market the system. The company also offers an Aerospace Measurement Service that has evolved from other SBIR contracts.

Source record↗

Precision and radiosonde validation of satellite gridpoint temperature anomalies. I - MSU channel 2. II - A tropospheric retrieval and trends during 1979-90

Monthly 2.5-deg gridpoint anomalies in the Tiros-N satellite series Microwave Sounding Unit channel 2 brightness temperatures during 1979-1988 are evaluated with multiple satellites and radiosonde data for their climate temperature monitoring capability. The MSU anomalies are computed about a 10-yr mean annual cycle at each gridpoint, with the MSUs intercalibrated to a common arbitrary level. The monthly gridpoint anomaly agreement between concurrently operating satellites reveals single-satellite precision generally better than 0.07 C in the tropics and better than 0.15 C at higher latitudes. The removal from channel 2 of the temperature influence above the 30-kPa level is addressed, providing a sharper and thus potentially more useful weighting function for monitoring lower tropospheric temperatures.

Spencer, Roy W.↗

Body/bone-marrow differential-temperature sensor

Differential-temperature sensor developed to compare bone-marrow and body temperature in leukemia patients uses single stable amplifier to monitor temperature difference recorded by thermocouples. Errors are reduced by referencing temperatures to each other, not to separate calibration points.

Anselmo, V. J.↗

Gas-Temperature Measurement With Minimal Perturbation

Method for measuring temperature of hot turbulent gases uses three heatflux calorimeters. One calorimeter measures radiative heat flux, while other two measure total heat flux (convective and radiative), at two different temperatures. Adapted for commercial uses in such operations as monitoring temperatures of flue gases, piped liquid or gaseous products, internal-combustion or jet engine exhausts.

Fu, T. S.↗

Application of fuzzy logic to the control of wind tunnel settling chamber temperature

The application of Fuzzy Logic Controllers (FLC's) to the control of nonlinear processes, typically controlled by a human operator, is a topic of much study. Recent application of a microprocessor-based FLC to the control of temperature processes in several wind tunnels has proven to be very successful. The control of temperature processes in the wind tunnels requires the ability to monitor temperature feedback from several points and to accommodate varying operating conditions in the wind tunnels. The FLC has an intuitive and easily configurable structure which incorporates the flexibility required to have such an ability. The design and implementation of the FLC is presented along with process data from the wind tunnels under automatic control.

Gwaltney, David A.↗

Air and Water Temperature Relationship and Growth of Hyacinth and Primrose

Temperature is a primary determining factor for plant growth and development so providing an appropriate temperature input is critically important for developing growth models. The Delta Region Areawide Aquatic Weed Project (DRAAWP), a USDA (US Dept. of Agriculture)-sponsored area-wide project including NASA Ames Research Center and State of California Department of Boating and Waterways, uses modeling to assess invasive aquatic plant impacts on ecosystem services in the Delta. Availability of continuous records for monitored temperature is limited and particularly in the case of water temperature the distribution of monitoring is inadequate. This work quantitatively defines the influence of air and water temperature in determining dominant growth rate processes for important floating aquatic invasive plants in the Delta. Since these plants function with portions submerged and above water we wanted to understand the relationship between root zone and shoot zone temperature and ability to use a single temperature inputs in DRAAWP models. Water Hyacinth and Primrose were gown in multiple controlled environment chamber studies with various combinations of root zone and shoot zone temperatures. Long-term growth studies provided integrated response of biomass accumulation and distribution within the canopy. Short-term gas exchange studies provide a time scale for responsiveness to temperature and a short-term study approach to evaluate temperature responses at various stages of canopy development.

Hyacinth↗

Flight Tests on a Fiber Optic Temperature Sensor

For aircraft engine control, one key parameter to detect on an airplane is the exhaust gas temperature (EGT). Presently, thermocouples are used to perform this measurement. These electrical sensors perform adequately; however, fully utilizing the benefits of optical sensors requires replacing electrical architectures with optical architectures. Part of this requires replacing electrical sensors with optical sensors, such as the EGT sensor chosen for these tests. The objective of the development and testing of this prototype sensor system was to determine the feasibility of operating an optical sensor in a hostile aircraft environment. The fiber optic sensor system was developed to measure temperatures from 20C to 600C in an aircraft environment and was utilized to monitor the EGT of an OV-10D aircraft engine. The sensor has successfully flown over 50 hours and proven to be immune to surface deterioration of the optical element (located inside the sensor head) and able to withstand and operate in normal and sustained severe flight conditions where forces on the airplane exceeded 4 g's. Potential commercial uses for this sensor include monitoring temperature for aeropropulsion system control, military vehicle and naval engine control, conventional and nuclear power plant monitoring and industrial plan monitoring where EMI issues are critical.

Tuma, Margaret L.↗