Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature logs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

MULTI-STRANDED AND MULTI-THERMAL SOLAR CORONAL LOOPS: EVIDENCE FROM HINODE X-RAY TELESCOPE AND EUV IMAGING SPECTROMETER DATA

Data from the X-Ray Telescope (XRT) and the EUV Imaging Spectrometer (EIS) on the Japanese/USA/UK Hinode spacecraft were used to investigate the spatial and thermal properties of an isolated quiescent coronal loop. We constructed differential emission measure (DEM) curves using Monte Carlo based, iterative forward fitting algorithms. We studied the loop as a whole, in segments, in transverse cuts, and point-by-point, always with some form of background subtraction, and find that the loop DEM is neither isothermal nor extremely broad, with approximately 96% of the EM between 6.2 {<=}log T{<=} 6.7, and an EM-weighted temperature of log T = 6.48 {+-} 0.16. We find evidence for a gradual change in temperature along the loop, with log T increasing only by {approx}0.1 from the footpoints to the peak. The combine XRT-EIS data set does a good job of constraining the temperature distribution for coronal loop plasma. Our studies show that the strong constraints at high and low temperatures provided by the combined data set are crucial for obtaining reasonable solutions. These results confirm that the observations of at least some loops are not consistent with isothermal plasma, and therefore cannot be modeled with a single flux tube and must be multi-stranded.

79 ASTRONOMY AND ASTROPHYSICS↗

Rotational modulation and flares on RS canum Venaticorum and BY Draconis stars. XVI - IUE spectroscopy and VLA observations of Gl 182( = V 1005 Orionis) in October 1983

A large flare was detected simultaneously with IUE and VLA on Gl 182 on October 5, 1983, this event showing the largest C IV flare enhancement yet observed by IUE. A smaller flare was also detected on October 4, although only with the IUE satellite. Line ratio and emission measure techniques are used to derive various physical parameters of the flares. The radiative losses in the temperature region log T(e) = 4.3-5.4 in the two flares are 2.9 x 10 to the 33rd and 8.4 x 10 to the 32nd ergs, respectively. Total radiative losses over the whole temperature range log T(e) = 4.0-8.0 are estimated to be of the order of 6.4 x 10 to the 34th and 1.1 x 10 to the 34th ergs, respectively. In the October 5, flare, a very strong ultraviolet continuum is present with a total energy of 1.9 x 10 to the 33rd ergs over the wavelength range 1250-1950 A.

Mathioudakis, M.↗

ATOMIC Simulations and Experimental Data for Basalt-like Compounds

This data consists of simulations and experimental measurements of laser-induced breakdown spectroscopy (LIBS). The simulations are produced by ATOMIC, a general purpose plasma modeling and kinetics code that has been designed to compute emission (or absorption) spectra from plasmas [2]. The makeup of the plasma was considered to be divided into some proportion water, some proportion Martian atmosphere (CO2), and some proportion target (from the rock or object impacted by the laser), where these proportions add to 1. Based on expert knowledge, the proportion of water was kept in the range [0.0,0.5] and the proportion of atmosphere was kept in the range [0.02, 0.9]. Our overall suite of simulations contains six sets of simulations that differ in which elements were considered to make up the target. Within each set, we used uniformly drawn temperatures and log mass densities within pre-specified ranges. The temperature range was [0.5,1.5] eV and the log (base 10) mass density range was [-7,-4]. The proportion of water, atmosphere, and target were drawn from a symmetric Dirichlet distribution, but draws in which the propor- tion of water or atmosphere exceeded the pre-specified limits were rejected from the design. Up to eleven constituent elements (Si, Al, Fe, Mg, Ca, O, Ti, Mn, Na, K, P) were considered for the target, as they are the most common elements found in basalt compounds and were used in [1]. For each run, the proportions of the constituent elements making up the target were drawn from a symmetric Dirichlet distribution. We ran 1,350 simulations that included nonzero proportions of all eleven elements. We also ran simulations which excluded some of these elements. In particular, we ran 1,000 simulations that only included nonzero proportions for the six most common elements (Si, Al, Fe, Mg, Ca, O). We also ran five sets, each with 500 simulations, that only included nonzero proportions for five of the six most common elements (but where all sets included O). Thus, we generated a total of 4,850 spectra representing basalt-like compounds in which the target was comprised of oxygen and between four and ten other elements. The ATOMIC code produced spectra over a range of 240nm - 880nm that roughly mimics the range collected by the ChemCam instrument on the Mars rover Curiosity. Each spectra had 32,000 wavelengths split across three spectrometer ranges (to mimic ChemCam). The experimental data, described in [1], measures a prepared basalt sample. All files are kept in directories whose names indicate the set of elements considered for the target with file names numbered to indicate the line in the design files used to produce the simulation. The designs are provided as text files with names indicating their purpose. The experimental data is provided as a CSV file which contains a header with measurement information, followed by a collection of 50 shots across a collection of wavelengths, along with the computed median and mean across shots.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PROPERTIES OF CARBON–OXYGEN WHITE DWARFS FROM MONTE CARLO STELLAR MODELS

We investigate properties of carbon–oxygen white dwarfs with respect to the composite uncertainties in the reaction rates using the stellar evolution toolkit, Modules for Experiments in Stellar Astrophysics (MESA) and the probability density functions in the reaction rate library STARLIB. These are the first Monte Carlo stellar evolution studies that use complete stellar models. Focusing on 3 M{sub ⊙} models evolved from the pre main-sequence to the first thermal pulse, we survey the remnant core mass, composition, and structure properties as a function of 26 STARLIB reaction rates covering hydrogen and helium burning using a Principal Component Analysis and Spearman Rank-Order Correlation. Relative to the arithmetic mean value, we find the width of the 95% confidence interval to be ΔM{sub 1TP} ≈ 0.019 M{sub ⊙} for the core mass at the first thermal pulse, Δt{sub 1TP} ≈ 12.50 Myr for the age, Δlog(T{sub c}/K) ≈ 0.013 for the central temperature, Δlog(ρ{sub c}/g cm{sup −3}) ≈ 0.060 for the central density, ΔY{sub e,c} ≈ 2.6 × 10{sup −5} for the central electron fraction, ΔX{sub c}({sup 22}Ne) ≈ 5.8 × 10{sup −4}, ΔX{sub c}({sup 12}C) ≈ 0.392, and ΔX{sub c}({sup 16}O) ≈ 0.392. Uncertainties in the experimental {sup 12}C(α,γ){sup 16}O, triple-α, and {sup 14}N(p,γ){sup 15}O reaction rates dominate these variations. We also consider a grid of 1–6 M{sub ⊙} models evolved from the pre main-sequence to the final white dwarf to probe the sensitivity of the initial–final mass relation to experimental uncertainties in the hydrogen and helium reaction rates.

79 ASTRONOMY AND ASTROPHYSICS↗

Utah FORGE 2439: Well 16B(78)-32 Field-Test Data from Mini-Frac Tests

This submittal includes the field-test data collected during stress tests conducted in the Utah FORGE 16B(78)-32 wellbore to measure/characterize the stresses in the geothermal reservoir. The type of stress test performed is referred to as a mini-frac test or a micro-frac test. The test is a hydraulic fracture test that involves injecting a small volume of water into a short interval of the reservoir that is isolated by a straddle packer to create a fracture. The test provides information about the minimum and maximum horizontal stress at the test depths. A total of seven mini-frac tests were performed within the upper (vertical or nearly vertical) section of the 9-5/8-inch diameter uncased wellbore, between depths of 5,202 ft MD [5,202 ft TVD] and 5,980 ft MD [5966.18 ft TVD]. Two types of data were generated as part of the mini-frac tests. The first type of data is time-series data for each mini-frac test (e.g., injection-rate, test-interval pressure), and are contained in the "Mini-Frac Test Data.zip" file below. The second type is geophysical log data, attached below in the "Geophysical Logs.zip" file. Here, two types of image logs and acoustic logs were obtained before and after the mini-frac tests to examine each test depth for visual evidence of induced fracture(s) and to measure the azimuth (orientation) of any observed fractures. The attached Readme file includes the test depth information and contents of each data file included here. Analysis of the field-test data was conducted and is documented in the attached report below.

15 GEOTHERMAL ENERGY↗

AASG Wells Data for the EGS Test Site Planning and Analysis Task

Temperature measurement data obtained from boreholes for the Association of American State Geologists (AASG) geothermal data project. Typically bottomhole temperatures are recorded from log headers, and this information is provided through a borehole temperature observation service for each state. Service includes header records, well logs, temperature measurements, and other information for each borehole. Information presented in Geothermal Prospector was derived from data aggregated from the borehole temperature observations for all states. For each observation, the given well location was recorded and the best available well identifier (name), temperature and depth were chosen. The "Well Name Source," "Temp. Type" and "Depth Type" attributes indicate the field used from the original service. This data was then cleaned and converted to consistent units. The accuracy of the observation's location, name, temperature or depth was note assessed beyond that originally provided by the service. Bottom hole temperature datasets from the AASG were downloaded from repository.usgin.org between May 16 and May 24, 2013. The data were cleaned to remove null and non-real entries, and units were standardized across all datasets. When selecting key attributes, specific criteria were used to determine the best available values. For temperature, corrected temperature was preferred, followed by measured temperature. For depth, depth of measurement was prioritized, with true vertical depth and driller total depth used as alternatives. Well identification was assigned based on the API number when available, followed by the well name, with the observation URI used as a last option.

15 GEOTHERMAL ENERGY↗

Physiologic Responses Produced by Active and Passive Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to document and compare the subjects' response to three cooling vests in their recommended configurations. The Life Enhancement Tech (LET) lightweight active cooling vest with cap, the MicroClimate Systems Change of Phase garment (MCS), and the Steele Vest were each used to cool the chest regions of 12 male and 8 female Healthy subjects (21 to 69 yr.) in this study. The subjects, seated in an upright position at normal room temperature (approx. 22 C), were tested for 60 min. with one of the cooling garments. The LET active garment had an initial coolant fluid inlet temperature of 60 F, and was ramped down to 50 F. Oral, right and left ear canal temperatures were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; and respiration were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. For men, all three vests had similar, significant cooling effects. Decreases in the average rectal temperature, oral temperature, and ear canal temperatures were approximately 0.2 C, 0.2 C and 0.1 C, respectively. In contrast to the men, the female subjects wearing the MCS and Steel vests had similar cooling responses in which the core temperature remained elevated and oral and ear canal temperatures did not drop. The LET active garment cooled most of the female subjects in this study; rectal, oral and ear temperature decreased about 0.2 C, 0.3 C and 0.3 C, respectively. These results show that the garment configurations tested do not elicit a similar thermal response in all subjects. A gender difference is evident. The LET active garment configuration was most effective in decreasing temperatures of the female subjects; the MCS vest was least effective. For male subjects, the three vests appear to be more nearly equivalent. The active garment system under study included a cooling cap, which may account for some of the difference in response.

Ku, Yu-Tsuan E.↗

Temperature Monitoring and Data-logging System Operating Manual

The MD-2 LabVIEW program is designed to monitor and store the temperature data from the MD-2 Compliance Testing. The program allows the user to easily configure and track data. A configuration file can be modified and stored to provide the setup parameters. It provides a user interface that easily informs the user about unforeseen anomalies.

42 ENGINEERING↗

Physiologic and Functional Responses of MS Patients to Body Cooling Using Commercially Available Cooling Garments

Personal cooling systems are widely used in industrial and aerospace environments to alleviate thermal stress. Increasingly they are also used by heat sensitive multiple sclerosis (HSMS) patients to relieve symptoms and improve quality of life. There are a variety of cooling systems commercially available to the MS community. However, little information is available regarding the comparative physiological changes produced by routine operation of these various systems. The objective of this study was to document and compare the patient response to two passive cooling vests and one active cooling garment. The Life Enhancement Technology, Inc. (LET) lightweight active cooling vest with cap, the MicroClimate Systems (MCS) Change of Phase garment, and the Steele Vest were each used to cool 13 male and 13 female MS subjects (31 to 67 yr.) in this study. The subjects, seated in an upright position at normal room temperature (approximately 22 C), were tested with one of the cooling garments. Oral, fight and left ear temperatures were logged manually every 5 min. An-n, leg, chest and rectal temperatures; heart rate; and respiration were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. Each subject was given a series of subjective and objective evaluation tests before and after cooling. The LET and Steele vests test groups had similar, significant (P less than 0.01) cooling effects on oral and ear canal temperature, which decreased approximately 0.4 C, and 0.3 C, respectively. Core temperature increased (N.S.) with all three vests during cooling. The LET vest produced the coldest (P less than 0.01) skin temperature. Overall, the LET vest provided the most improvement on subjective and objective performance measures. These results show that the garment configurations tested do not elicit a similar thermal response in all MS patients. Cooling with the LET active garment configuration resulted in the lowest body temperatures for the MS subjects; cooling with the MCS vest was least effective. For functional responses, the LET test group performed better than the other two vests.

Ku, Yu-Tsuan E.↗

Hemodynamic Responses to Head and Neck Cooling

Personal thermoregulatory systems which provide head and neck cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objective of this study was to measure the scalp temperature and circulatory responses during use of one commercially available thermal control system. The Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used in this study. Two EEG electrodes and one skin temperature transducer were placed on the anterior midline of the scalp to measure the scalp blood and temperature. Blood flow was measured using a bipolar impedance rheograph. Ten subjects, seated in an upright position at normal room temperature, were tested at high, medium, moderate, moderate-low and low coolant temperatures. Scalp blood flow was recorded continuously using a computer data acquisition system with a sampling frequency of 200 Hz. Scalp temperature and cooling helmet Inlet temperature was logged periodically during the test period. This study quantifies the effect of head cooling upon scalp temperature and blood flow. These data may also be used to select operational specifications of the head cooling system for biomedical applications such as the treatment of migraine headaches, scalp cooling during chemotherapy, and cooling of multiple sclerosis patients.

Ku, Yu-Tsuan E.↗

Solar flare impulsive phase emission observed with SDO/EVE

Differential emission measures (DEMs) during the impulsive phase of solar flares were constructed using observations from the EUV Variability Experiment (EVE) and the Markov-Chain Monte Carlo method. Emission lines from ions formed over the temperature range log T{sub e} = 5.8-7.2 allow the evolution of the DEM to be studied over a wide temperature range at 10 s cadence. The technique was applied to several M- and X-class flares, where impulsive phase EUV emission is observable in the disk-integrated EVE spectra from emission lines formed up to 3-4 MK and we use spatially unresolved EVE observations to infer the thermal structure of the emitting region. For the nine events studied, the DEMs exhibited a two-component distribution during the impulsive phase, a low-temperature component with peak temperature of 1-2 MK, and a broad high-temperature component from 7 to 30 MK. A bimodal high-temperature component is also found for several events, with peaks at 8 and 25 MK during the impulsive phase. The origin of the emission was verified using Atmospheric Imaging Assembly images to be the flare ribbons and footpoints, indicating that the constructed DEMs represent the spatially average thermal structure of the chromospheric flare emission during the impulsive phase.

79 ASTRONOMY AND ASTROPHYSICS↗

Utah FORGE: Well 16A(78)-32 Logs

This dataset contains all well logs from Utah FORGE well 16A(78)-32. This includes the mud log, Sanvean Technologies logs, and Schlumberger logs. Please see the file descriptions below for information about each log.

15 GEOTHERMAL ENERGY↗

Fallon FORGE: Well Log Database

Master well database for all logs and other well data pertaining to the Fallon FORGE site. Tables are formatted in NGDS Teir 3 schema where appropriate; redundancies between tables are omitted, and should be queried off of the main WellHeader table. All relationships are set on the "HeaderURI" primary key. Tables: WellHeader - well locations and information ChemFluid - aqueous chemistry analyses ChemRock - rock chemistry analyses DensityCore - rock densities from core FracturesInduced - induced borehole fractures FracturesNatural - natural borehole factures LithIntercepts - lithology picks from cuttings and core MagSuscCore - magnetic susceptibility for core samples MagSuscPmag - magnetic susceptibility for pmag samples PTSLogs - pressure-temperature-spin logs WirelineLogs - digital wireline logs (21-31 only)

15 GEOTHERMAL ENERGY↗

UV extinction and IR emission in diffuse H2 regions

During this period, much work was spent in an attempt to use theoretical UV line indices as a basis for spectral calibration of the program stars. Five line indices are shown as functions of effective temperature and log g, calculated with the spectral synthesis programs of Kurucz. Open stars and circles are observed values from Fanelli et al., using the spectral class-effective temperature calibration of Schmidt-Kaler. We conclude that these line indices may be used to determine an effective stellar temperature, but with uncertainties of approximately a few thousand degrees. Also, for the hotter stars, theoretical line opacities are systematically low compared to observations. We have also found that Kurucz's new models appear to represent hot stars very well, even at far-UV wavelengths. This is shown in an example where two spectra of mu Col (spectral class 09.5 V) are compared to a synthetic spectrum for T(sub eff) = 33,000 K, log g = 4.0. Also shown (uppermost curve) is an empirical estimate of the intrinsic flux distribution for 09.5 V stars from Papaj, Wegner, and Krelowski.

Aannestad, Per A.↗

ISOTHERMAL AND MULTITHERMAL ANALYSIS OF CORONAL LOOPS OBSERVED WITH AIA

The coronal filters in the Atmospheric Imaging Assembly (AIA) aboard the Solar Dynamics Observatory peak at different temperatures; the series covers the entire active region temperature range, making AIA ideal for multithermal analysis. Here, we analyze coronal loops from several active regions that have been observed by AIA. We have specifically targeted cool loops (or at least loops with a cool component) that were chosen in the 171 A channel of AIA, which has a peak response temperature of log T = 5.8. We wanted to determine if the loops could be described as isothermal or multithermal. We find that several of our 12 loops have narrow temperature distributions, which may be consistent with isothermal plasma; these can be modeled with a single flux tube. Other loops have intermediate-width temperature distributions, appear well-constrained, and should be multi-stranded. The remaining loops, however, have unrealistically broad differential emission measures. We find that this problem is the result of missing low-temperature lines in the AIA 131 A channel. If we repeat the analysis without the 131 A data, these loops also appear to be well-constrained and multi-stranded.

79 ASTRONOMY AND ASTROPHYSICS↗