EDDY CURRENT SYSTEM FOR DETECTION OF CRACKING BENEATH BRAIDING IN CORRUGATED METAL HOSE

In this paper an eddy current system for the detection of partially-through-the-thickness cracks in corrugated metal hose is presented. Design criteria based upon the geometry and conductivity of the part are developed and applied to the fabrication of a prototype inspection system. Experimental data are used to highlight the capabilities of the system and an image processing technique is presented to improve flaw detection capabilities. A case study for detection of cracking damage in a space shuttle radiator retract flex hoses is also presented.

39↗

Paraxial ray-tracing approach for the simulation of ultrasonic inspection of welds

On-site inspection of bimetallic or austenitic welds can be very difficult to interpret owing to their internal structures. Skewing and splitting of the ultrasonic beam may occur due to the anisotropic and inhomogeneous properties of the welding material. In this paper, we present a ray-based method to simulate the propagation of ultrasonic waves in such structures. The formalism is based on dynamic ray tracing system in Cartesian coordinates along a reference ray. Standard ray tracing consists in the solution of a system of linear ordinary differential equations of the first order and is used to determine the trajectory of the ray. Likewise, dynamic ray tracing (DRT) also called paraxial ray tracing consists in the solution of an additional system of linear ordinary differential equations along the ray allowing paraxial quantities to be computed. It is used to evaluate the geometrical spreading and amplitude along the ray and in its vicinity. DRT is applied on a smooth representation of the elastic properties of the weld obtained thanks to an image processing technique applied on a macrograph of the weld. Simulation results are presented and compared to finite elements and experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-I-45: An Automated Technique to Measure Image Contrast in Clinical CT Images

Purpose: To develop and validate an automated technique for measuring image contrast in chest computed tomography (CT) exams. Methods: An automated computer algorithm was developed to measure the distribution of Hounsfield units (HUs) inside four major organs: the lungs, liver, aorta, and bones. These organs were first segmented or identified using computer vision and image processing techniques. Regions of interest (ROIs) were automatically placed inside the lungs, liver, and aorta and histograms of the HUs inside the ROIs were constructed. The mean and standard deviation of each histogram were computed for each CT dataset. Comparison of the mean and standard deviation of the HUs in the different organs provides different contrast values. The ROI for the bones is simply the segmentation mask of the bones. Since the histogram for bones does not follow a Gaussian distribution, the 25th and 75th percentile were computed instead of the mean. The sensitivity and accuracy of the algorithm was investigated by comparing the automated measurements with manual measurements. Fifteen contrast enhanced and fifteen non-contrast enhanced chest CT clinical datasets were examined in the validation procedure. Results: The algorithm successfully measured the histograms of the four organs in both contrast and non-contrast enhanced chest CT exams. The automated measurements were in agreement with manual measurements. The algorithm has sufficient sensitivity as indicated by the near unity slope of the automated versus manual measurement plots. Furthermore, the algorithm has sufficient accuracy as indicated by the high coefficient of determination, R2, values ranging from 0.879 to 0.998. Conclusion: Patient-specific image contrast can be measured from clinical datasets. The algorithm can be run on both contrast enhanced and non-enhanced clinical datasets. The method can be applied to automatically assess the contrast characteristics of clinical chest CT images and quantify dependencies that may not be captured in phantom data.

60 APPLIED LIFE SCIENCES↗

Using cloud radar to investigate the effect of rainfall on migratory insect flight

The fate of migrating insects that encounter rainfall in flight is a critical consideration when modelling insect movement, but few field observations of this common phenomenon have ever been collected due to the logistical challenges of witnessing these encounters. Operational cloud radars have been deployed around the world by meteorological agencies to study precipitation physics, and as a byproduct, provide a rich database of insect observations that is freely available to researchers. Although considered unwanted ‘clutter’ by the meteorologists who collect the data, the analysis method presented here enables ecologists to delineate co-occurring signals from insects and raindrops. We present a method that uses image processing techniques on cloud radar velocity spectra to examine the fate of migrating insects when they encounter precipitation. By analysing velocity spectra, we can distinguish flying insects from falling rain and compare the relative density of insects in flight before, during and after the rainfall. We demonstrate the method on a case of insect migration in Oklahoma, USA. Using this method, we show the first reconstructed images of migrating insect layers in flight during rainfall. Our analysis shows that mild to moderate rainfall diminishes the number of insects aloft but does not cause full termination of migratory flight, as has previously been suggested. We hope this technique will spur further investigations of how changing weather conditions impact insect migration, and enable some of the first of such studies in regions of the world that are underrepresented in the literature.

54 ENVIRONMENTAL SCIENCES↗

BFSVBF (BatFinder Smart Video BioFilter) [SWR-22-87] and Multi-class BatFinder Smart Video BioFilter Keras

Bats are notoriously difficult to study, therefore, identifying specific behavioral trends and the precise environmental conditions at the time of collision requires a monitoring solution that can reliably collect relevant data. To date, thermal infrared video surveillance has been extensively applied to study bats and has proven to be a powerful yet cumbersome tool. Current analytical approaches are time consuming because data processing data has not been fully automated. In the past, steps have been taken to record avian and bat activity in conjunction with complicated image processing techniques that separate species from other moving objects within the field of view (i.e. clouds and portions of the wind turbine). Once the videos are collected, the post-processing does not allow real time monitoring and identification, leading to a delay in both studying the behavior of these species and determining the effectiveness of any impact reduction strategy being studied. Moreover, object identification capability is lacking, thus limiting the usefulness of video data. To resolve these issues, we are using open source computer vision and machine learning techniques allowing for automatic detection of objects in real-time with the ability to correlate these objects with environmental variables and recording the flight paths of each object. The code has gone through five rounds of development with images used to train the models. This advancement allows for automated real-time data collection, identification, and tracking, thereby eliminating the need for long and tedious post-analysis processing of the videos. We will discuss the two open source and publicly available machine learning models developed within this scope of this work: 1) a binary model with a 97.5% accuracy in identifying the difference between an object and an empty scene, including wind turbine and clouds; and 2) a multiple classification model with the capability of identifying the type of object detected: bats (90% accuracy), birds (83% accuracy), insects (69% accuracy) and non-biological (99% accuracy).

Yarbrough, John↗

Machine learning technique to identify grains in polycrystalline materials samples

A method of identifying grains in polycrystalline materials, the method including (a) identifying local crystal structure of the polycrystalline material based on neighbor coordination or pattern recognition machine learning, the local crystal structure including grains and grain boundaries, (b) pre-processing the grains and the grain boundaries using image processing techniques, (c) conducting grain identification using unsupervised machine learning; and (d) refining a resolution of the grain boundaries.

Sankaranarayanan, Subramanian↗

SU-G-201-01: An Automated Treatment Plan Quality Assurance Program for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

Purpose: Plan specific quality assurance (QA) is an important step in high dose rate (HDR) brachytherapy to ensure the integrity of a treatment plan. The conventional approach is to assemble a set of plan screen-captures in a document and have an independent plan-checker to verify it. Not only is this approach cumbersome and time-consuming, using a document also limits the items that can be verified, hindering plan quality and patient safety. We have initiated efforts to develop a web-based HDR brachytherapy QA system called AutoBrachy QA, for comprehensive and efficient QA. This abstract reports a new plugin in this system for the QA of a cylinder HDR brachytherapy treatment. Methods: A cylinder plan QA module was developed using Python. It was plugged into our AutoBrachy QA system. This module extracted information from CT images and treatment plan. Image processing techniques were employed to obtain geometric parameters, e.g. cylinder diameter. A comprehensive set of eight geometrical and eight dosimetric features of the plan were validated against user specified planning parameter, such as prescription value, treatment depth and length, etc. A PDF document was generated, consisting of a summary QA sheet with all the QA results, as well as images showing plan details. Results: The cylinder QA program has been implemented in our clinic. To date, it has been used in 11 patient cases and was able to successfully perform QA tests in all of them. The QA program reduced the average plan QA time from 7 min using conventional manual approach to 0.5 min. Conclusion: Being a new module in our AutoBrachy QA system, an automated treatment plan QA module for cylinder HDR brachytherapy has been successfully developed and clinically implemented. This module improved clinical workflow and plan integrity compared to the conventional manual approach.

60 APPLIED LIFE SCIENCES↗

Robust primary modulation-based scatter estimation for cone-beam CT

Purpose: Scattered radiation is one of the major problems facing image quality in flat detector cone-beam computed tomography (CBCT). Previously, a new scatter estimation and correction method using primary beam modulation has been proposed. The original image processing technique used a frequency-domain-based analysis, which proved to be sensitive to the accuracy of the modulator pattern both spatially and in amplitude as well as to the frequency of the modulation pattern. In addition, it cannot account for penumbra effects that occur, for example, due to the finite focal spot size and the scatter estimate can be degraded by high-frequency components of the primary image. Methods: In this paper, the authors present a new way to estimate the scatter using primary modulation. It is less sensitive to modulator nonidealities and most importantly can handle arbitrary modulator shapes and changes in modulator attenuation. The main idea is that the scatter estimation can be expressed as an optimization problem, which yields a separation of the scatter and the primary image. The method is evaluated using simulated and experimental CBCT data. The scattering properties of the modulator itself are analyzed using a Monte Carlo simulation. Results: All reconstructions show strong improvements of image quality. To quantify the results, all images are compared to reference images (ideal simulations and collimated scans). Conclusions: The proposed modulator-based scatter reduction algorithm may open the field of flat detector-based imaging to become a quantitative modality. This may have significant impact on C-arm imaging and on image-guided radiation therapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic resolution mapping of interfacial intermixing and segregation in InAs/GaSb superlattices: A correlative study

We combine quantitative analyses of Z-contrast images with composition analyses employing atom probe tomography (APT) correlatively to provide a quantitative measurement of atomic scale interfacial intermixing in an InAs/GaSb superlattice (SL). Contributions from GaSb and InAs in the Z-contrast images are separated using an improved image processing technique. Correlation with high resolution APT composition analyses permits an examination of interfacial segregation of both cations and anions and their incorporation in the short period InAs/GaSb SL. Results revealed short, intermediate, and long-range intermixing of In, Ga, and Sb during molecular beam epitaxial growth and their distribution in the SL.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental study on turbulent mixing of spray droplets in crossflow

Centrifugal spray injected at various angles in gas crossflow has been studied experimentally using PIV visualization system and image-processing techniques. Experiments were carried out inside a rectangular duct (95 mm x 95 mm in cross-section) at ambient temperature and pressure, with different gas Reynolds numbers (vary from 12,900 to 45,000) and three injection angles (60 , 90 and 120 ). The spray angle of the centrifugal nozzle is 80 , with D{sub 32} of 80 {mu}m. The instantaneous images of droplets distribution and the values of the line-averaged D{sub 32} at different positions on the cross-sections along the flow field for each condition were obtained, and their flow field configurations were achieved. Quantitative assessments of mixing degree between two phases for different injection angles were determined using a spatial unmixedness parameter. It is found that the addition of droplets into the gas crossflow enhanced the turbulence intensity of the gas crossflow and caused different-scale vortices. The flow field structure, to a great extent, is dependent on the injection angle. The entrainment and centrifugal force of large vortex lead to uneven droplet distribution and moreover influence the mixing of droplets and gas crossflow. A better mixing result can be obtained with the injection angle of nozzles of 60 . (author)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization of Rare Earth Element Minerals in Coal Utilization Byproducts

The United States currently produces over 100 million tons of coal utilization byproducts (CUB) per year in the form of fly ash, bottom ash, slag, and flue gas (American Coal Ash Association (ACCA), 2015). But this “waste material” also contains potentially useful levels of rare earth elements (REE). Rare earth elements are crucial for many existing and emerging technologies, but the U.S. lacks a domestic, sustainable REE source. Our project explored the possibility of developing a supply of REEs for U.S. technologies by extracting REEs from CUBs. This work offers the potential to reduce our dependence on other countries for supply of these critical elements (NETL, REE 2016 Project Portfolio). Geologic and diagenetic history, industrial preparation methods, and the specific combustion process all play major roles in the composition of CUB. During combustion, inorganic mineral phases of coal particles are fluidized at temperatures higher than 1400oC, so inorganic mineral materials are oxidized, fused, disintegrated, or agglomerated into larger spherical and amorphous (non-crystalline) particles. The original mineralogy of the coal-containing rock and heating/cooling of the material significantly affects the composition and morphology of the particles in the combustion byproduct (Kutchko and Kim, 2006). Thus, different types of coal/refuse/ash must be characterized to better understand mineral evolution during the combustion process. Our research focused on developing a working model to address how REE minerals behave during the combustion process: this research should help determine the most effective engineering methods for extracting REEs from CUBs. We used multimodal imaging and image processing techniques to characterize six rock and ash samples from different coal power plants with respect to morphology, grain size, presence of mineral phases, and elemental composition. The results of these characterization activities provided thresholds for realizing the occurrence of REE mineral phases in CUB and allowed us to calculate structural and volumetric estimates of REE. Collectively, the rock and coal ash samples contained minerals such as quartz, kaolinite, muscovite/illite, iron oxide (as hematite or magnetite), mullite, and clinochlore. Trace minerals included pyrite, zircon, siderite, rutile, diopside, foresterite, gypsum, and barite. We identified REE phosphate minerals monazite (Ce,La,Nd,Th)(PO 4 ,SiO 4 ), xenotime (YPO 4 ,SiO 4 ), and apatite (Ca 5 (PO 4 ) 3 (F,Cl,OH) via SEM and electron microprobe analysis: these materials generally occurred as 1-10 μm-long crystals in the rock and ash samples. As has been shown in other studies, amorphous material-aluminosilicate glass or iron oxyhydroxide-are the major components of coal fly and bottom ash. Trace amounts of amorphous calcium oxide and mixed element (e.g., Al-Si-Ca-Fe) slag are also present. Quartz, mullite, hematite, and magnetite are the crystalline phases present. We found that REEs are present as monomineralic grains dispersed within the ash, as well as fused to or encapsulated by amorphous aluminosilicate glass particles. Monazite and xenotime have relatively high melting points (>1800 °C) compared to typical combustion temperatures; our observations indicate that the REE-phosphates, which presumably contribute a large percentage of REE to the bulk ash REE pool, as measured by mass spectroscopy, are largely unaltered by the combustion. Our study shows that conventional coal combustion processes sequester REE minerals into aluminosilicate glass phases, which presents a new engineering challenge for extracting REE from coal ash. The characterization work summarized in this report provides a semi-quantitative assessments of REE in coal-containing rock and CUB. The data we obtained from 2- and 3-D imaging, elemental mapping, volumetric estimates, and advanced high-resolution pixel classification successfully identified the different mineral phases present in CUB. Further, our characterization results can guide techniques for extracting REEs from CUB, or other geologic and engineered materials. Whilst, interpretations will inform future REE separation and extraction techniques and technologies practical for commercial utilization of combustion byproducts generated by power plants.

01 COAL, LIGNITE, AND PEAT↗

SU-F-T-70: A High Dose Rate Total Skin Electron Irradiation Technique with A Specific Inter-Film Variation Correction Method for Very Large Electron Beam Fields

Purpose: Rotational total skin electron irradiation (RTSEI) is used in the treatment of cutaneous T-cell lymphoma. Due to inter-film uniformity variations the dosimetry measurement of a large electron beam of a very low energy is challenging. This work provides a method to improve the accuracy of flatness and symmetry for a very large treatment field of low electron energy used in dual beam RTSEI. Methods: RTSEI is delivered by dual angles field a gantry of ±20 degrees of 270 to cover the upper and the lower halves of the patient body with acceptable beam uniformity. The field size is in the order of 230cm in vertical height and 120 cm in horizontal width and beam energy is a degraded 6 MeV (6 mm of PMMA spoiler). We utilized parallel plate chambers, Gafchromic films and OSLDs as a measuring devices for absolute dose, B-Factor, stationary and rotational percent depth dose and beam uniformity. To reduce inter-film dosimetric variation we introduced a new specific correction method to analyze beam uniformity. This correction method uses some image processing techniques combining film value before and after radiation dose to compensate the inter-variation dose response differences among films. Results: Stationary and rotational depth of dose demonstrated that the Rp is 2 cm for rotational and the maximum dose is shifted toward the surface (3mm). The dosimetry for the phantom showed that dose uniformity reduced to 3.01% for the vertical flatness and 2.35% for horizontal flatness after correction thus achieving better flatness and uniformity. The absolute dose readings of calibrated films after our correction matched with the readings from OSLD. Conclusion: The proposed correction method for Gafchromic films will be a useful tool to correct inter-film dosimetric variation for the future clinical film dosimetry verification in very large fields, allowing the optimizations of other parameters.

60 APPLIED LIFE SCIENCES↗

Adaptive thresholding and dynamic windowing method for automatic centroid detection of digital Shack-Hartmann wavefront sensor

A Shack-Hartmann wavefront sensor (SWHS) splits the incident wavefront into many subsections and transfers the distorted wavefront detection into the centroid measurement. The accuracy of the centroid measurement determines the accuracy of the SWHS. Many methods have been presented to improve the accuracy of the wavefront centroid measurement. However, most of these methods are discussed from the point of view of optics, based on the assumption that the spot intensity of the SHWS has a Gaussian distribution, which is not applicable to the digital SHWS. In this paper, we present a centroid measurement algorithm based on the adaptive thresholding and dynamic windowing method by utilizing image processing techniques for practical application of the digital SHWS in surface profile measurement. The method can detect the centroid of each focal spot precisely and robustly by eliminating the influence of various noises, such as diffraction of the digital SHWS, unevenness and instability of the light source, as well as deviation between the centroid of the focal spot and the center of the detection area. The experimental results demonstrate that the algorithm has better precision, repeatability, and stability compared with other commonly used centroid methods, such as the statistical averaging, thresholding, and windowing algorithms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wavelet Denoising of Radio Observations of Rotating Radio Transients (RRATs): Improved Timing Parameters for Eight RRATs

Rotating radio transients (RRATs) are sporadically emitting pulsars detectable only through searches for single pulses. While over 100 RRATs have been detected, only a small fraction (roughly 20%) have phase-connected timing solutions, which are critical for determining how they relate to other neutron star populations. Detecting more pulses in order to achieve solutions is key to understanding their physical nature. Astronomical signals collected by radio telescopes contain noise from many sources, making the detection of weak pulses difficult. Applying a denoising method to raw time series prior to performing a single-pulse search typically leads to a more accurate estimation of their times of arrival (TOAs). Taking into account some features of RRAT pulses and noise, we present a denoising method based on wavelet data analysis, an image-processing technique. Assuming that the spin period of an RRAT is known, we estimate the frequency spectrum components contributing to the composition of RRAT pulses. This allows us to suppress the noise, which contributes to other frequencies. We apply the wavelet denoising method including selective wavelet reconstruction and wavelet shrinkage to the de-dispersed time series of eight RRATs with existing timing solutions. The signal-to-noise ratio (S/N) of most pulses are improved after wavelet denoising. Compared to the conventional approach, we measure 12%–69% more TOAs for the eight RRATs. The new timing solutions for the eight RRATs show 16%–90% smaller estimation error of most parameters. Thus, we conclude that wavelet analysis is an effective tool for denoising RRATs signal.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of interfacial transition zone on the Young's modulus of carbon nanofiber reinforced cement concrete

Identifying the properties of the region where the cement paste meets the aggregate surface (interfacial transition zone, ITZ) is critical to understanding the strength and fracture behavior of carbon nanofiber (CNF) reinforced cement concrete. In this study, the finite element method is employed to investigate the effect of the ITZ on the Young's modulus of cement concrete made with CNF. The numerical models for cement concrete with and without CNF are constructed based on the digital image processing technique. To consider the interface effect, the concept of ''effective aggregate'' is put forward, namely, the Young's modulus and Poisson's ratio for each aggregate particle are replaced by an effective Young's modulus and effective Poisson's ratio, in which the effect of thickness and the Young's modulus of ITZ is taken into account in an averaged manner. Then, the quantitative nanomechanical mapping (based on atomic force microscopy) technique is adopted to measure the Young's modulus and thickness of ITZ with and without CNFs, which are further used as the input parameters in the numerical model. The numerical simulation results are verified by experimental testing, which indicates that the ITZ effect should be considered when implementing the numerical simulation. In addition, this analysis shows that compared with the plain cement concrete, CNFs can greatly enhance the mechanical properties of ITZ, which will in turn improve the Young's modulus of cement concrete significantly. Finally, the effect of thickness and Young's modulus of ITZ on the Young's modulus of CNF reinforced cement concrete is also discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

TRANSIENT FRAGMENTS IN OUTBURSTING COMET 17P/HOLMES {sup ,}

We present results from a wide-field imaging campaign at the Canada-France-Hawaii Telescope to study the spectacular outburst of comet 17P/Holmes in late 2007. Using image-processing techniques we probe inside the spherical dust coma and find 16 fragments having both spatial distribution and kinematics consistent with isotropic ejection from the nucleus. Photometry of the fragments is inconsistent with scattering from monolithic, inert bodies. Instead, each detected fragment appears to be an active cometesimal producing its own dust coma. By scaling from the coma of the primary nucleus of 17P/Holmes, assumed to be 1.7 km in radius, we infer that the 16 fragments have maximum effective radii between {approx}10 m and {approx}100 m on UT 2007 November 6. The fragments subsequently fade at a common rate of {approx}0.2 mag day{sup -1}, consistent with steady depletion of ices from these bodies in the heat of the Sun. Our characterization of the fragments supports the hypothesis that a large piece of material broke away from the nucleus and crumbled, expelling smaller, icy shards into the larger dust coma around the nucleus.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantifying the debonding of inclusions through tomography and computational homology.

This report describes a Laboratory Directed Research and Development (LDRD) project to use of synchrotron-radiation computed tomography (SRCT) data to determine the conditions and mechanisms that lead to void nucleation in rolled alloys. The Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory (LBNL) has provided SRCT data of a few specimens of 7075-T7351 aluminum plate (widely used for aerospace applications) stretched to failure, loaded in directions perpendicular and parallel to the rolling direction. The resolution of SRCT data is 900nm, which allows elucidation of the mechanisms governing void growth and coalescence. This resolution is not fine enough, however, for nucleation. We propose the use statistics and image processing techniques to obtain sub-resolution scale information from these data, and thus determine where in the specimen and when during the loading program nucleation occurs and the mechanisms that lead to it. Quantitative analysis of the tomography data, however, leads to the conclusion that the reconstruction process compromises the information obtained from the scans. Alternate, more powerful reconstruction algorithms are needed to address this problem, but those fall beyond the scope of this project.

43 PARTICLE ACCELERATORS↗

Thermal Image Processing for Feature Extraction from Encapsulated Phase Change Materials

Encapsulated inorganic particles with high melting points (>300 °C) are desired as high-temperature Phase Change Materials (PCMs) for next-generation Latent Heat Thermal Energy Storage (LHTES) systems. One of the many challenges during the development of PCMs is to achieve a high throughput that in turn depends on accurately modeling the relation between process parameters and geometric & thermal properties of the PCMs particle. During the production of the PCMs, a high-speed infrared camera is used to acquire images of the encapsulated material under controlled illumination conditions. This research article focuses on the development of image processing techniques for both geometric and thermal feature extraction during the development of the PCMs. A user-friendly GUI has been designed in MATLAB and preliminary experimental results have demonstrated that the method is fast, accurate and reliable for a high throughput production. The extracted features will be used to develop Machine Learning (ML) models to predict the geometric and thermal properties of the PCM based on the process parameter settings. The ML model will accelerate the search for the optimized process settings to boost the throughput of the production.

25 ENERGY STORAGE↗