Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “systematic errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A systematic error affecting NER calculations

Factors that may affect the precision of Neutron Emission Rate (NER) measurements made in the Canberra 4 neutron counter have been examined and quantified. Measurements of sample NER are corrected for the efficiency of the counter. The efficiency is calculated by measuring a source of known intensity, and taking the ratio of the measured neutrons per second (n/s) to the known output of the source.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of systematic errors in lateral shearing interferometry for EUV optical testing

Lateral shearing interferometry (LSI) provides a simple means for characterizing the aberrations in optical systems at EUV wavelengths. In LSI, the test wavefront is incident on a low-frequency grating which causes the resulting diffracted orders to interfere on the CCD. Due to its simple experimental setup and high photon efficiency, LSI is an attractive alternative to point diffraction interferometry and other methods that require spatially filtering the wavefront through small pinholes which notoriously suffer from low contrast fringes and improper alignment. In order to demonstrate that LSI can be accurate and robust enough to meet industry standards, analytic models are presented to study the effects of unwanted grating and detector tilt on the system aberrations, and a method for identifying and correcting for these errors in alignment is proposed. The models are subsequently verified by numerical simulation. Finally, an analysis is performed of how errors in the identification and correction of grating and detector misalignment propagate to errors in fringe analysis.

36 MATERIALS SCIENCE↗

ASSESSMENT OF SYSTEMATIC CHROMATIC ERRORS THAT IMPACT SUB-1% PHOTOMETRIC PRECISION IN LARGE-AREA SKY SURVEYS

Meeting the science goals for many current and future ground-based optical large-area sky surveys requires that the calibrated broadband photometry is both stable in time and uniform over the sky to 1% precision or better. Past and current surveys have achieved photometric precision of 1%–2% by calibrating the survey’s stellar photometry with repeated measurements of a large number of stars observed in multiple epochs. The calibration techniques employed by these surveys only consider the relative frame-by-frame photometric zeropoint offset and the focal plane position-dependent illumination corrections, which are independent of the source color. However, variations in the wavelength dependence of the atmospheric transmission and the instrumental throughput induce source color-dependent systematic errors. These systematic errors must also be considered to achieve the most precise photometric measurements. In this paper, we examine such systematic chromatic errors (SCEs) using photometry from the Dark Energy Survey (DES) as an example. We first define a natural magnitude system for DES and calculate the systematic errors on stellar magnitudes when the atmospheric transmission and instrumental throughput deviate from the natural system. We conclude that the SCEs caused by the change of airmass in each exposure, the change of the precipitable water vapor and aerosol in the atmosphere over time, and the non-uniformity of instrumental throughput over the focal plane can be up to 2% in some bandpasses. We then compare the calculated SCEs with the observed DES data. For the test sample data, we correct these errors using measurements of the atmospheric transmission and instrumental throughput from auxiliary calibration systems. The residual after correction is less than 0.3%. Moreover, we calculate such SCEs for Type Ia supernovae and elliptical galaxies and find that the chromatic errors for non-stellar objects are redshift-dependent and can be larger than those for stars at certain redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

First Simultaneous Determination of Inclusive and Exclusive | V u b |

The first simultaneous determination of the absolute value of the Cabibbo-Kobayashi-Maskawa matrix element V ub using inclusive and exclusive decays is performed with the full Belle data set at the $Υ$(4S) resonance, corresponding to an integrated luminosity of 711 fb -1 . We analyze collision events in which one B meson is fully reconstructed in hadronic modes. This allows for the reconstruction of the hadronic X u system of the semileptonic b → $πℓe_ℓ$ decay. We separate exclusive B → $πℓ\overline{ν}_ℓ$ decays from other inclusive B → $X_uℓ\overline{ν}_ℓ$ and backgrounds with a two-dimensional fit that utilizes the number of charged pions in the X u system and the four-momentum transfer q 2 between the B and X u systems. Combining our measurement with information from lattice QCD and QCD calculations of the inclusive partial rate as well as external experimental information on the shape of the B → $πℓe_ℓ$ form factor, we determine |$V^{excl}_{ub}$| = (3.78 ± 0.23 ± 0.16 ± 0.14) × 10 -3 and |$V^{incl}_{ub}$| = (3.88 ± 0.20 ± 0.31 ± 0.09) x 10 -3 , respectively, with the uncertainties being the statistical error, systematic errors, and theory errors. The ratio of |$V^{excl}_{ub}$|/|$V^{incl}_{ub}$| 0.97 ± 0.12 is compatible with unity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey: BAO and RSD measurements from the anisotropic power spectrum of the quasar sample between redshift 0.8 and 2.2

ABSTRACT We measure the clustering of quasars of the final data release (DR16) of eBOSS. The sample contains $343\, 708$ quasars between redshifts 0.8 ≤ z ≤ 2.2 over $4699\, \mathrm{deg}^2$. We calculate the Legendre multipoles (0,2,4) of the anisotropic power spectrum and perform a BAO and a Full-Shape (FS) analysis at the effective redshift zeff = 1.480. The errors include systematic errors that amount to 1/3 of the statistical error. The systematic errors comprise a modelling part studied using a blind N-body mock challenge and observational effects studied with approximate mocks to account for various types of redshift smearing and fibre collisions. For the BAO analysis, we measure the transverse comoving distance DM(zeff)/rdrag = 30.60 ± 0.90 and the Hubble distance DH(zeff)/rdrag = 13.34 ± 0.60. This agrees with the configuration space analysis, and the consensus yields: DM(zeff)/rdrag = 30.69 ± 0.80 and DH(zeff)/rdrag = 13.26 ± 0.55. In the FS analysis, we fit the power spectrum using a model based on Regularised Perturbation Theory, which includes redshift space distortions and the Alcock–Paczynski effect. The results are DM(zeff)/rdrag = 30.68 ± 0.90 and DH(zeff)/rdrag = 13.52 ± 0.51 and we constrain the linear growth rate of structure f(zeff)σ8(zeff) = 0.476 ± 0.047. Our results agree with the configuration space analysis. The consensus analysis of the eBOSS quasar sample yields: DM(zeff)/rdrag = 30.21 ± 0.79, DH(zeff)/rdrag = 3.23 ± 0.47, and f(zeff)σ8(zeff) = 0.462 ± 0.045 and is consistent with a flat ΛCDM cosmological model using Planck results.

Neveux, Richard↗

Automated suppression of errors in LTP-II slope measurements with x-ray optics. Part1: Review of LTP errors and methods for the error reduction

Systematic error and instrumental drift are the major limiting factors of sub-microradian slope metrology with state-of-the-art x-ray optics. Significant suppression of the errors can be achieved by using an optimal measurement strategy suggested in [Rev. Sci. Instrum. 80, 115101 (2009)]. With this series of LSBL Notes, we report on development of an automated, kinematic, rotational system that provides fully controlled flipping, tilting, and shifting of a surface under test. The system is integrated into the Advanced Light Source long trace profiler, LTP-II, allowing for complete realization of the advantages of the optimal measurement strategy method. We provide details of the system’s design, operational control and data acquisition. The high performance of the system is demonstrated via the results of high precision measurements with a spherical test mirror.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-BRD-03: Determination of Plan Robustness for Systematic Setup Errors Using Trilinear Interpolation

Purpose: Treatment plan evaluations in radiotherapy are currently ignoring the dosimetric impact of setup uncertainties. The determination of the robustness for systematic errors is rather computational intensive. This work investigates interpolation schemes to quantify the robustness of treatment plans for systematic errors in terms of efficiency and accuracy. Methods: The impact of systematic errors on dose distributions for patient treatment plans is determined by using the Swiss Monte Carlo Plan (SMCP). Errors in all translational directions are considered, ranging from −3 to +3 mm in mm steps. For each systematic error a full MC dose calculation is performed leading to 343 dose calculations, used as benchmarks. The interpolation uses only a subset of the 343 calculations, namely 9, 15 or 27, and determines all dose distributions by trilinear interpolation. This procedure is applied for a prostate and a head and neck case using Volumetric Modulated Arc Therapy with 2 arcs. The relative differences of the dose volume histograms (DVHs) of the target and the organs at risks are compared. Finally, the interpolation schemes are used to compare robustness of 4- versus 2-arcs in the head and neck treatment plan. Results: Relative local differences of the DVHs increase for decreasing number of dose calculations used in the interpolation. The mean deviations are <1%, 3.5% and 6.5% for a subset of 27, 15 and 9 used dose calculations, respectively. Thereby the dose computation times are reduced by factors of 13, 25 and 43, respectively. The comparison of the 4- versus 2-arcs plan shows a decrease in robustness; however, this is outweighed by the dosimetric improvements. Conclusion: The results of this study suggest that the use of trilinear interpolation to determine the robustness of treatment plans can remarkably reduce the number of dose calculations. This work was supported by Varian Medical Systems. This work was supported by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

A Comparison of Cosmological Parameters Determined from CMB Temperature Power Spectra from the South Pole Telescope and the Planck Satellite

The Planck cosmic microwave background temperature data are best fit with a Lambda CDM model that mildly contradicts constraints from other cosmological probes. The South Pole Telescope (SPT) 2540 deg(2) SPT-SZ survey offers measurements on sub-degree angular scales (multipoles 650 <= l <= 2500) with sufficient precision to use as an independent check of the Planck data. Here we build on the recent joint analysis of the SPT-SZ and Planck data in Hou et al. by comparing Lambda CDM parameter estimates using the temperature power spectrum from both data sets in the SPT-SZ survey region. We also restrict the multipole range used in parameter fitting to focus on modes measured well by both SPT and Planck, thereby greatly reducing sample variance as a driver of parameter differences and creating a stringent test for systematic errors. We find no evidence of systematic errors from these tests. When we expand the maximum multipole of SPT data used, we see low-significance shifts in the angular scale of the sound horizon and the physical baryon and cold dark matter densities, with a resulting trend to higher Hubble constant. When we compare SPT and Planck data on the SPT-SZ sky patch to Planck full-sky data but keep the multipole range restricted, we find differences in the parameters n(s) and A(s)e(-2 tau). We perform further checks, investigating instrumental effects and modeling assumptions, and we find no evidence that the effects investigated are responsible for any of the parameter shifts. Taken together, these tests reveal no evidence for systematic errors in SPT or Planck data in the overlapping sky coverage and multipole range and at most weak evidence for a breakdown of Lambda CDM or systematic errors influencing either the Planck data outside the SPT-SZ survey area or the SPT data at l > 2000.

Aylor, K.↗

The impact of tomographic redshift bin width errors on cosmological probes

ABSTRACT Systematic errors in the galaxy redshift distribution n(z) can propagate to systematic errors in the derived cosmology. We characterize how the degenerate effects in tomographic bin widths and galaxy bias impart systematic errors on cosmology inference using observational data from the Deep Lens Survey. For this we use a combination of galaxy clustering and galaxy–galaxy lensing. We present two end-to-end analyses from the catalogue level to parameter estimation. We produce an initial cosmological inference using fiducial tomographic redshift bins derived from photometric redshifts, then compare this with a result where the redshift bins are empirically corrected using a set of spectroscopic redshifts. We find that the derived parameter S8 ≡ σ8(Ωm/.3)1/2 decreases from $0.841^{+0.062}_{-0.061}$ to $0.781^{0.061}_{0.054}$ upon correcting the n(z) errors in the second method.

79 ASTRONOMY AND ASTROPHYSICS↗

Predetermining acceptable noise limits in EXAFS spectra in the limit of stochastic noise

EXAFS measurements are used to probe a variety of experimental systems, but excel at elucidating local structure in samples which have slight disorder or no long-range crystalline order. Of special interest to the authors is the use of EXAFS in understanding the molecular-level binding structure and characteristics of actinides on the surface of environmental minerals and model mineral analogs. In environmental systems the element of interest can be on the order of 10-7% by weight of the total sample. Obviously such samples would be impossible to measure using EXAFS techniques. It is therefore essential to increase the concentration of the element of interest while still preserving a sample's ability to represent environmental conditions. Under such low concentration limits it is expected that the collected data is countrate, or stochastically limited. This condition occurs as we approach the signal-to-noise (S/N) limit of the technique where the random noise of the measurement process dominates over possible systematic errors. When stochastic error is expected to dominate systematic error, it is possible to predict, with the use of simulations, the ability of model fits to tolerate a certain level of stochastic noise. Elsewhere in these proceedings, we discuss how to tell when systematic errors dominate in measured EXAFS spectrum. Here, we outline a technique for determining the number of EXAFS scans necessary to test the relevance of a given structural model. Appropriate stochastic noise levels are determined for each point in r-space by collecting data on a real system. These noise levels are then applied to EXAFS simulations using a test model. In this way, all significant systematic error sources are eliminated in the simulated data. The structural model is then fit to the simulated data, decreasing the noise and increasing the k-range of the fit until the veracity of the model passes an F-test. This paper outlines a method of testing model systems in EXAFS fitting before measurements are conducted to determine the quality of measured data required for fitting of a particular model system with statistical confidence. It is important to reiterate that the calculated {alpha}surface in figure 1 is only applicable to the particular model presented in this paper. Furthermore, this procedure only takes into account stochastic noise; consequentially any confidence levels calculated should be viewed as upper limits to the confidence levels in systems which also contain a significant amount of systematic noise.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

FERMI LARGE AREA TELESCOPE OBSERVATIONS OF TWO GAMMA-RAY EMISSION COMPONENTS FROM THE QUIESCENT SUN

We report the detection of high-energy {gamma}-rays from the quiescent Sun with the Large Area Telescope on board the Fermi Gamma-Ray Space Telescope (Fermi) during the first 18 months of the mission. These observations correspond to the recent period of low solar activity when the emission induced by cosmic rays (CRs) is brightest. For the first time, the high statistical significance of the observations allows clear separation of the two components: the point-like emission from the solar disk due to CR cascades in the solar atmosphere and extended emission from the inverse Compton (IC) scattering of CR electrons on solar photons in the heliosphere. The observed integral flux ({>=}100 MeV) from the solar disk is (4.6 {+-} 0.2[statistical error]{sup +1.0}{sub -0.8}[systematic error]) x 10{sup -7} cm{sup -2} s{sup -1}, which is {approx}7 times higher than predicted by the 'nominal' model of Seckel et al. In contrast, the observed integral flux ({>=}100 MeV) of the extended emission from a region of 20 deg. radius centered on the Sun, but excluding the disk itself, (6.8 {+-} 0.7[stat.]{sup +0.5}{sub -0.4}[syst.]) x 10{sup -7} cm{sup -2} s{sup -1}, along with the observed spectrum and the angular profile, is in good agreement with the theoretical predictions for the IC emission.

79 ASTRONOMY AND ASTROPHYSICS↗

VLBI FOR GRAVITY PROBE B. V. PROPER MOTION AND PARALLAX OF THE GUIDE STAR, IM PEGASI

We present the principal astrometric results of the very long baseline interferometry (VLBI) program undertaken in support of the Gravity Probe B (GP-B) relativity mission. VLBI observations of the GP-B guide star, the RS CVn binary IM Pegasi (HR 8703), yielded positions at 35 epochs between 1997 and 2005. We discuss the statistical assumptions behind these results and our methods for estimating the systematic errors. We find the proper motion of IM Peg in an extragalactic reference frame closely related to the International Celestial Reference Frame 2 (ICRF2) to be -20.83 {+-} 0.03 {+-} 0.09 mas yr{sup -1} in right ascension and -27.27 {+-} 0.03 {+-} 0.09 mas yr{sup -1} in declination. For each component, the first uncertainty is the statistical standard error and the second is the total standard error (SE) including plausible systematic errors. We also obtain a parallax of 10.37 {+-} 0.07 mas (distance: 96.4 {+-} 0.7 pc), for which there is no evidence of any significant contribution of systematic error. Our parameter estimates for the {approx}25 day period orbital motion of the stellar radio emission have SEs corresponding to {approx}0.10 mas on the sky in each coordinate. The total SE of our estimate of IM Peg's proper motion is {approx}30% smaller than the accuracy goal set by the GP-B project before launch: 0.14 mas yr{sup -1} for each coordinate of IM Peg's proper motion. Our results ensure that the uncertainty in IM Peg's proper motion makes only a very small contribution to the uncertainty of the GP-B relativity tests.

79 ASTRONOMY AND ASTROPHYSICS↗

Accuracy Evaluation of a 3-Dimensional Surface Imaging System for Guidance in Deep-Inspiration Breath-Hold Radiation Therapy

Purpose: To investigate the applicability of 3-dimensional (3D) surface imaging for image guidance in deep-inspiration breath-hold radiation therapy (DIBH-RT) for patients with left-sided breast cancer. For this purpose, setup data based on captured 3D surfaces was compared with setup data based on cone beam computed tomography (CBCT). Methods and Materials: Twenty patients treated with DIBH-RT after breast-conserving surgery (BCS) were included. Before the start of treatment, each patient underwent a breath-hold CT scan for planning purposes. During treatment, dose delivery was preceded by setup verification using CBCT of the left breast. 3D surfaces were captured by a surface imaging system concurrently with the CBCT scan. Retrospectively, surface registrations were performed for CBCT to CT and for a captured 3D surface to CT. The resulting setup errors were compared with linear regression analysis. For the differences between setup errors, group mean, systematic error, random error, and 95% limits of agreement were calculated. Furthermore, receiver operating characteristic (ROC) analysis was performed. Results: Good correlation between setup errors was found: R{sup 2}=0.70, 0.90, 0.82 in left-right, craniocaudal, and anterior-posterior directions, respectively. Systematic errors were {<=}0.17 cm in all directions. Random errors were {<=}0.15 cm. The limits of agreement were -0.34-0.48, -0.42-0.39, and -0.52-0.23 cm in left-right, craniocaudal, and anterior-posterior directions, respectively. ROC analysis showed that a threshold between 0.4 and 0.8 cm corresponds to promising true positive rates (0.78-0.95) and false positive rates (0.12-0.28). Conclusions: The results support the application of 3D surface imaging for image guidance in DIBH-RT after BCS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SYSTEMATIC CONTINUUM ERRORS IN THE Ly{alpha} FOREST AND THE MEASURED TEMPERATURE-DENSITY RELATION

Continuum fitting uncertainties are a major source of error in estimates of the temperature-density relation (usually parameterized as a power-law, T {proportional_to} {Delta}{sup {gamma}-1}) of the intergalactic medium through the flux probability distribution function (PDF) of the Ly{alpha} forest. Using a simple order-of-magnitude calculation, we show that few percent-level systematic errors in the placement of the quasar continuum due to, e.g., a uniform low-absorption Gunn-Peterson component could lead to errors in {gamma} of the order of unity. This is quantified further using a simple semi-analytic model of the Ly{alpha} forest flux PDF. We find that under(over)estimates in the continuum level can lead to a lower (higher) measured value of {gamma}. By fitting models to mock data realizations generated with current observational errors, we find that continuum errors can cause a systematic bias in the estimated temperature-density relation of ({delta}({gamma})) Almost-Equal-To -0.1, while the error is increased to {sigma}{sub {gamma}} Almost-Equal-To 0.2 compared to {sigma}{sub {gamma}} Almost-Equal-To 0.1 in the absence of continuum errors.

79 ASTRONOMY AND ASTROPHYSICS↗