Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development of techniques for gantryless associated-particle imaging

To move fast-neutron radiography using the associated-particle imaging technique from the laboratory to the field, the development of new analysis techniques is required. In particular, the relative positions of the source and detectors need to be determined when they have been placed by hand, the normalization for a particular source–detector geometry needs to be determined without a measurement in the same geometry with no object present, and accurate image stitching is required when multiple detector positions are necessary to image an object. The present work describes methods that employ transmission neutron data to localize a fast-neutron imaging panel with respect to the neutron source, calculate a normalization for a given source–detector geometry, stitch images together, and describes the required system calibrations. The reported techniques enable in-field neutron radiography for cases in which the source–detector geometry is not well known a priori and where operational constraints preclude a normalization measurement.

Heath, Matthew↗

Quantitative Assessment and Measurement of X-ray Detector Performance and Solid Angle in the Analytical Electron Microscope

A wide range of X-ray detectors and geometries are available today on transmission/scanning transmission analytical electron microscopes. While there have been numerous reports of their individual performance, no single experimentally reproducible metric has been proposed as a basis of comparison between the systems. In this paper, we detail modeling, experimental procedures, measurements, and specimens which can be used to provide a manufacturer-independent assessment of the performance of an analytical system. Using these protocols, the geometrical collection efficiency, system peaks, and minimum detection limits can be independently assessed and can be used to determine the best conditions to conduct modern hyperspectral and/or spectrally resolved tomographic analyses for an individual instrument. Here, a simple analytical formula and specimen is presented which after suitable system calibrations can be used to experimentally determine the X-ray detector solid angle.

47 OTHER INSTRUMENTATION↗

The ultrafast pixel array camera system and its applications in high energy density physics

Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.

47 OTHER INSTRUMENTATION↗

SPECTER: an instrument concept for CMB spectral distortion measurements with enhanced sensitivity

Deviations of the cosmic microwave background (CMB) energy spectrum from a perfect blackbody uniquely probe a wide range of physics, ranging from fundamental physics in the primordial Universe (μ-distortion) to late-time baryonic feedback processes (y-distortion). While the y-distortion can be detected with a moderate increase in sensitivity over that of COBE/FIRAS, the ΛCDM-predicted μ-distortion is roughly two orders of magnitude smaller and requires substantial improvements, with foregrounds presenting a serious obstacle. Within the standard model, the dominant contribution to μ arises from energy injected via Silk damping, yielding sensitivity to the primordial power spectrum at wavenumbers k ≈ 1-10 4 Mpc -1 . Here, we present a new instrument concept, SPECTER, with the goal of robustly detecting μ. The instrument technology is similar to that of LiteBIRD, but with an absolute temperature calibration system. Using a Fisher approach, we optimize the instrument's configuration to target μ while marginalizing over foreground contaminants. Unlike Fourier-transform-spectrometer-based designs, the specific bands and their individual sensitivities can be independently set in this instrument, allowing significant flexibility. We forecast SPECTER to observe the ΛCDM-predicted μ-distortion at ≈ 5σ (10σ) assuming an observation time of 1 (4) year(s) (corresponding to mission duration of 2 (8) years), after foreground marginalization. Our optimized configuration includes 16 bands spanning 1–2000 GHz with ∼degree-scale angular resolution at ∼ 150 GHz and 1100 total detectors. SPECTER will additionally measure the y-distortion at sub-percent precision and its relativistic correction at percent-level precision, yielding tight constraints on the total thermal energy and mean temperature of ionized gas.

CMBR experiments↗

Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter

Measurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb−1. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, construction, and operation of a 1-ton Water-based Liquid scintillator detector at Brookhaven National Laboratory

Water-based liquid scintillators (WbLS) are a new class of detector materials that provide efficient and tunable detection of both Cherenkov and scintillation light. A massive WbLS neutrino detector with suitable photosensor coverage for low intensity light detection could therefore reconstruct the momentum of an energetic charged particle and also have enhanced low-energy sensitivity. These materials are also better suited for metal doping broadening the potential scientific utility. Here, we recently constructed and commissioned a 1-ton WbLS detector with good photosensor coverage and a capable data acquisition and calibration system. We intend to use this flexible detector system as a testbed for WbLS R&D. In this paper we give an overview of the 1-ton system and provide some early results.

47 OTHER INSTRUMENTATION↗

Suppressing Quantum Circuit Errors Due to System Variability

We present a quantum circuit optimization technique that takes into account the variability in error rates that is inherent across present-day noisy quantum computing platforms. This method can be run after qubit routing or postcompilation and consists of computing isomorphic subgraphs to input circuits and scoring each using heuristic cost functions derived from system calibration data. Using an independent standard algorithmic test suite, we show that it is possible to recover on average nearly 40% of missing fidelity using better qubit selection via efficient to compute cost functions. We demonstrate additional performance gains by considering qubit placement over multiple quantum processors. The overhead from these tools is minimal with respect to other compilation steps, such as qubit routing, as the number of qubits increases. As such, our method can be used to find qubit mappings for problems at the scale of quantum advantage and beyond.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantifying uncertainty in physics-based predictions of rare-isotope production cross sections via Bayesian-inspired model averaging across nuclear mass tables

Accurate prediction of fragmentation cross sections is essential for rare-isotope beam production, planning new-isotope searches, and designing experiments to study the most exotic regions of the nuclear chart. However, existing reaction models and phenomenological cross-section parametrizations often exhibit significant deviations over broad regions of mass and charge. In this work, a Bayesian-inspired model-averaging framework is developed to combine abrasion-ablation (AA) calculations based on multiple nuclear mass tables into a single statistically weighted estimate. For the calibrated systems, the model weights are assigned empirically according to the relative quality of fit to measured cross sections, thereby reducing systematic model bias while preserving the underlying physics content of the AA description. The weights are constrained using proton-rich fragmentation data for the 78 Kr and 124 Xe projectiles. The resulting parameter trends are then propagated to the 92 Mo and 144 Sm systems through a controlled scaling procedure. In the present implementation, the excitation-energy prescription is fixed, while the averaging is performed across nuclear-mass inputs; the framework provides both weighted cross sections and associated uncertainty estimates. Applied to proton-rich fragmentation, the present approach provides a practical basis for interpolation and limited extrapolation in regions relevant to rare-isotope production. The resulting predictions are used to assess the production of very proton-rich nuclei, and candidate new isotopes are discussed.

Bayesian methods↗

Dynamic computational optical fringe mitigation in tunable laser absorption spectroscopy

In optical spectroscopic systems where unwanted optical scattering cannot be eliminated, Fabry-Pérot etalons cause unpredictable changes in the spectral background. Frequent system calibration is then required to maintain the desired measurement accuracy, which presents a major limitation to the spectrometer. We introduce a computational approach to mitigate the adverse effects of optical fringing without hardware modifications. Motivated by experimental observations of complicated fringe behaviors, we simplify the problem by decomposing the fringe background into component etalons that can be addressed according to their individual characteristics. The effectiveness of the proposed method is demonstrated on a silicon photonic methane sensor, where accurate measurements of methane concentration are obtained from spectral data strongly affected by optical fringes.

Teng, Chu C. (ORCID:0000000152744835)↗

TP89 - SIRZ Decomposition Spectral Estimation (V.1.0)

The purpose of this test plan is to generate and evaluate calibrated system spectral response models for a dual-energy x-ray computed tomography (DECT) scanner. These spectral response models, which represent the energy distribution of photons observed by the detector with no test articles in the beam path, are necessary for spectral decomposition reconstruction techniques such as SIRZ, which are used for precise material characterization.

42 ENGINEERING↗

Winter School: Applications of Artificial Intelligence to Topics in Nuclear Physics

The virtual topical Winter School on Artificial Intelligence in Nuclear Physics aimed at giving the participants a deeper understanding on what Artificial Intelligence and Machine Learning are and how they can be used to analyze data, design new detectors, controls, and calibration systems for nuclear physics experiments and perform theoretical calculations of nuclear many-body systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2023 Reftek Colt Seismometer Exploratory Evaluation

Sandia National Laboratories has tested and evaluated three Colt broadband seismometers designed and manufactured by Reftek. The purpose of this seismometer evaluation is to measure performance characteristics in areas such as power consumption, sensitivity, frequency response, full scale, self-noise, dynamic range, calibration system response, and passband. The Colt model of sensors are being evaluated to explore the potential for a future seismometer Type Approval process in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT).

47 OTHER INSTRUMENTATION↗

2023 T120 Horizon and Slim Posthole Seismometer Exploratory Evaluation

Sandia National Laboratories has tested and evaluated a suite of four T120 broadband seismometers designed and manufactured by Nanometrics. Specifically, two T120 Horizon V2 sensors, one T120 Horizon V1 sensor and one T120 Slim Posthole (PH) sensor were evaluated. The purpose of this seismometer evaluation is to measure performance characteristics in areas such as power consumption, sensitivity, frequency response, full scale, self-noise, dynamic range, calibration system response, and passband. The T120 model of sensors are being evaluated to explore the potential for a future seismometer Type Approval process in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT).

47 OTHER INSTRUMENTATION↗

Demonstrating Advanced Sensors for In-Situ Monitoring Towards Qualification of Nuclear Relevant Components

The U.S. Department of Energy’s Office of Nuclear Energy Advanced Materials and Manufacturing Technologies (AMMT) program is pursuing qualification of laser powder bed fusion (LPBF) components for nuclear applications. A major focus of this effort is the use of in situ process monitoring and machine learning–based tools to establish real-time quality assurance. The primary objective of this report is to identify and evaluate the most relevant in situ sensor systems for LPBF, and to document the deployment of these systems across platforms critical to the AMMT program. This work demonstrates how in situ monitoring can detect process anomalies, track geometry-dependent flaws, and identify limiting combinations of processing parameters—particularly those related to energy density and complex geometries (e.g., overhanging structures). To support this goal, a diverse suite of sensor modalities was evaluated across LPBF platforms, including visible and near-infrared (NIR) imaging, fringe projection profilometry, long-wavelength infrared (LWIR) thermography, and high-speed photodiode/pyrometry systems. These sensor streams were integrated with Peregrine, a machine-agnostic software platform that, among other capabilities, can generate real-time process anomaly classification. This report documents sensor deployments on multiple AMMT flagship platforms, including the Concept Laser M2 and Renishaw AM400/AM250 systems. Calibration builds with complex, flaw-prone geometries such as unsupported overhangs, stepped features, and thin walls, were used to evaluate how well Peregrine and its associated sensors could detect process anomalies and other instabilities under varied energy densities. It will be shown how Peregrine reliably identifies common process anomalies such as recoater streaking, superelevation, etc., and can be used in post-build analysis for anomaly spatial distributions throughout the build height to better understand the impact of geometry and processing parameter choice on the build. This work demonstrates measurable progress toward the vision that components can be born-qualified by establishing a real-time monitoring framework, identifying limiting process conditions, and laying the foundation for sensor fusion–enabled prediction pipelines that are scalable across platforms and applicable to nuclear-relevant components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Novel Dew Point Meter: Application to the Measurement of the Sulfuric Acid Dew Point for Combustion Flue Gas

Accurate knowledge of acid dew point is essential for industrial and applied combustion applications. Sulfur in the fuel or raw materials is converted to sulfur dioxide (SO2) during combustion, and a portion of the SO2 is oxidized to sulfur trioxide (SO3). The SO3 will react to form H2SO4 vapor when in the presence of water vapor. Even with just trace levels of H2SO4 vapor in the gas phase (1-10 ppm), the dew point can reach 100°C and higher. To avoid acid condensation and the resulting corrosion on heat recovery equipment, plant engineers must ensure that surface temperatures are above the acid dew point, but this decreases the efficiency of thermal energy recovery. Thus, there is a trade-off between minimizing equipment corrosion and maximizing thermal energy recovery, and the acid dew point is a key parameter for this optimization. Commercially available acid dew point meters use electric conductivity sensors. These sensors are known to greatly underestimate the dew point due to their low sensitivity. In addition, no validation testing has been reported for these units and they are often expensive. In this work, we analyze the theory of the sulfuric acid condensation and develop a novel dew point meter based on this analysis. The meter consists of a novel optical instrument that is designed to monitor the slightest appearance of condensation on a hydrophobic window surface as the surface temperature of the window is slowly decreased. In this way, an accurate measurement of the dew point is obtained under a wide range of concentrations. The basis of the instrument is that a collimated beam from a diode laser will generate forward scattered light when the beam encounters surface condensate, and a sophisticated array detector is used to sensitively monitor the onset of light scattering. The measurement procedures are established to rapidly find the acid dew point, while minimizing error. Further, to calibrate the dew point meter we developed a calibration system based on a liquid bubbler that can generate a stable gas flow with a known sulfuric acid dew point. Test results show that the dew point meter can accurately measure acid dew point over a wide range. For H2SO4 vapor concentrations as low as 6 ppm the acid dew point is measured with an error of only ~1°C. To demonstrate the versatility of this instrument, the dew point meter was adapted for use with a high-pressure flow cell to allow for measurements of the dew point of flue gas from pressurized oxy-fuel combustion in a 100 kWth pressurized reactor.

Cheng, Mao↗

A Novel Dew Point Meter: Application to the Measurement of the Sulfuric Acid Dew Point for Combustion Flue Gas

Accurate knowledge of acid dew point is essential for industrial and applied combustion. Sulfur in the fuel or raw materials is converted to sulfur dioxide (SO2) during combustion, and a portion of the SO2 is oxidized to sulfur trioxide (SO3). The SO3 will react to form H2SO4 vapor when in the presence of water vapor. Even with just trace levels of H2SO4 vapor in the gas phase (1-10 ppm), the dew point can reach 100°C and higher. To avoid acid condensation and the resulting corrosion on heat recovery equipment, plant engineers must ensure that surface temperatures are above the acid dew point, but this decreases the efficiency of the thermal energy recovery. Thus, there is a trade-off between minimizing equipment corrosion and maximizing thermal energy recovery efficiency, and the acid dew point is a key parameter for this optimization. In this work, we analyze and discuss the theory of the sulfuric acid condensation process and develop a novel dew point meter based on this analysis. The meter consists of a novel optical instrument that is designed to monitor the slightest appearance of condensation on a hydrophobic window surface, and the surface temperature of the window is slowly decreased until condensation is first observed, yielding an accurate measurement of the dew point. The basis of the instrument is that a collimated beam from a diode laser generates scattered light when encountering surface condensate, and a sophisticated array detector is used to sensitively monitor the light scattering. The measurement procedures are established to rapidly find the acid dew point, while minimizing error. Further, we propose a calibration system based on a liquid bubbler, which can generate a stable gas flow with known sulfuric acid dew point, to test the dew point meter. Test results show that the dew point meter can accurately measure the acid dew point over a wide range.

Cheng, Mao↗

Studying MeV Scale Neutron Interactions in DUNE ND-LAr 2x2 Demonstrator

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment designed to make high-precision measurements of neutrino oscillation parameters and probe for new physics using a neutrino beam produced at Fermilab and measured at a near detector complex and a far detector located 1,300 km away at the Sanford Underground Research Facility. Precise neutrino energy reconstruction is essential for these measurements, with neutron production in neutrino–argon interactions representing a significant source of systematic uncertainty, as neutrons can carry away significant energy, making their detection and characterization crucial. DUNE’s near detector complex includes ND-LAr, a Liquid Argon Time Projection Chamber (LArTPC) detector designed to mirror the far detector technology and constrain neutrino–argon interaction systematics. The DUNE 2x2 Demonstrator, a pixelated LArTPC based on the ArgonCube design, serves as a prototype for ND-LAr. During 2x2 operations from October to November 2026, an Americium–Beryllium (AmBe) neutron source was deployed near the detector cryostat to obtain a high-statistics sample of neutron interactions. This poster presents progress in studying MeV-scale neutron interactions in this dataset by identifying de-excitation gammas from neutron capture on argon, providing a method for neutron identification and charge readout system calibration in future DUNE detectors.

Mao, Edgar [Syracuse U.] (ORCID:0009000600893306)↗