Methods to determine the radiated power in SPI-mitigated disruptions in JET

Here we present techniques for evaluating the radiated power in JET disruptions. Disrupting plasmas are shown to have non-axisymmetric radiation profiles, motivating the re-evaluation of the standard techniques for calculating the total radiated power at JET using bolometry. Four single-channel bolometers at different toroidal locations are exploited to quantify the radiation asymmetry. Toroidal radiation peaking factors integrated over the entire disruption of up to 1.5 have been observed when varying the quantity of neon in pellets used in disruptions mitigated by shattered pellet injection. Using synthetic bolometer diagnostics developed with the Cherab spectroscopy modeling framework, we can estimate the systematic error on total power calculations for relevant radiation profiles and improve estimates of the total radiated power. We show that the component of the systematic error on the total power due to the poloidal radiation profile can be reduced from 70% to 10% with suitable assumptions about the structure of the poloidal profile.

47 OTHER INSTRUMENTATION↗

Scoping study of detecting high harmonic fast waves in NSTX-U hot core plasma directly using beam emission spectroscopy

In this paper, we used radio frequency (RF) full wave simulation to explore the feasibility of generating a density beat oscillation formed by high harmonic fast waves (HHFWs) in the National Spherical Tokamak Experiment-Upgrade (NSTX-U) and of measuring it numerically with 2D beam emission spectroscopy (BES). This oscillation is of interest as it can be used to determine the injected RF fields. We began by computing HHFW fields in NSTX-U under a variety of experimental conditions and antenna configurations with Petra-M, a 3D RF wavefield solver. These fields were then used to evaluate the amplitude of δne,beat/ne0 in the volume of measurement, which we predict to be between 5 × 10−10 and 10−9, although it is highly dependent on plasma parameters. Trends in magnetic field, core temperature, core density, and antenna phasing are presented, and the parameters most suitable to this measurement are identified. Finally, we developed a synthetic BES diagnostic to compare the experimental BES signal against.

Rutherford, Grant (ORCID:0000000163620037)↗

Electron Cyclotron Emission–Based Separatrix Identification in ITER with OMFIT Synthetic Modeling

Accurate determination of the separatrix location is essential for understanding edge plasma behavior and optimizing confinement in tokamaks, especially in next-generation devices such as ITER. In this study, a synthetic microwave diagnostics module was developed and implemented in the OMFIT framework to assess the feasibility of an electron cyclotron emission–based separatrix detection method in ITER plasmas. Simulations were carried out using ITER H-mode equilibrium scenarios with different plasma density profiles and different pedestal widths. Here, the results show that the electron emission temperature profiles consistently exhibit an inversion pattern near the edge, with a well-defined minimum point that could serve as a proxy for the separatrix location. However, unlike in the DIII-D, the minimum point in ITER is systematically offset by approximately 2 cm into the scrape-off layer, independent of density or pedestal width, which is within the radial resolution range (2 to 5 cm) determined by the 500-MHz channel spacing. While the method does not provide the exact separatrix location, it offers a reliable indicator of the boundary region and has potential applications for real-time boundary monitoring in ITER and other future fusion devices.

Electron cyclotron emission↗

Developing and applying quantifiable metrics for diagnostic and experiment design on Z

This project applies methods in Bayesian inference and modern statistical methods to quantify the value of new experimental data, in the form of new or modified diagnostic configurations and/or experiment designs. We demonstrate experiment design methods that can be used to identify the highest priority diagnostic improvements or experimental data to obtain in order to reduce uncertainties on critical inferred experimental quantities and select the best course of action to distinguish between competing physical models. Bayesian statistics and information theory provide the foundation for developing the necessary metrics, using two high impact experimental platforms on Z as exemplars to develop and illustrate the technique. We emphasize that the general methodology is extensible to new diagnostics (provided synthetic models are available), as well as additional platforms. We also discuss initial scoping of additional applications that began development in the last year of this LDRD.

97 MATHEMATICS AND COMPUTING↗

Multimodal super-resolution: discovering hidden physics and its application to fusion plasmas

Understanding complex physical systems often requires integrating data from multiple diagnostics, each with limited resolution or coverage. We present a machine learning framework that reconstructs synthetic high-temporal-resolution data for a target diagnostic using information from other diagnostics, without direct target measurements during the inference. This multimodal super-resolution technique improves diagnostic robustness and enables monitoring even in case of measurement failures or degradation. Applied to fusion plasmas, our method targets edge-localized modes (ELMs), which can damage plasma-facing materials. By reconstructing super-resolution Thomson Scattering data from complementary diagnostics, we uncover fine-scale plasma dynamics and validate the role of resonant magnetic perturbations (RMPs) in ELM suppression through magnetic island formation. The approach provides new observation supporting the plasma profile flattening due to these islands. Our results demonstrate the framework’s ability to generate high-fidelity synthetic diagnostics, offering a powerful tool for ELM control development in future reactors like ITER. The approach is broadly transferable to other domains facing sparse, incomplete, or degraded diagnostic data, opening new avenues for discovery.

Jalalvand, Azarakhsh [Princeton Univ., NJ (United ↗

Design of a high-resolution Rayleigh-Taylor experiment with the Crystal Backlighter Imager on the National Ignition Facility

The Rayleigh-Taylor (RT) instability affects a vast range of High Energy Density (HED) length scales, spanning from supernova explosions (10 13 m) to inertial confinement fusion (10 -6 m). In inertial confinement fusion, the RT instability is known to induce mixing or turbulent transition, which in turn cools the hot spot and hinders ignition. The fine-scale features of the RT instability, which are difficult to image in HED physics, may help determine if the system is mixing or is transitioning to turbulence. Earlier diagnostics lacked the spatial and temporal resolution necessary to diagnose the dynamics that occur along the RT structure. A recently developed diagnostic, the Crystal Backlighter Imager (CBI), [1,2] can now produce an x-ray radiograph capable of resolving the fine-scale features expected in these RT unstable systems. This paper describes an experimental design that adapts a well-characterized National Ignition Facility (NIF) platform to accommodate the CBI diagnostic. Simulations and synthetic radiographs highlight the resolution capabilities of the CBI in comparison to previous diagnostics. Furthermore, the improved resolution of the system can provide new observations to study the RT instability's involvement in mixing and the transition to turbulence in the HED regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synthetic modeling of soft x-ray emissivity for magnetic island analysis in LTX-β

We present a synthetic soft x-ray (SXR) forward-modeling framework that characterizes the emissivity structure of rotating magnetic islands in the Lithium Tokamak eXperiment-β across space and time. Magnetic islands associated with tearing modes produce modulations in line-integrated SXR brightness. Traditional tomographic methods struggle to resolve these structures in devices with limited sightlines, resulting in an under-determined inversion problem, or otherwise necessitate equilibrium reconstruction data, preventing their use in active control. Our approach removes this challenge by combining a fully three-dimensional ray-tracing model with a time-dependent emissivity prescription of a $m/n$ = 2/1 magnetic island. The model is validated through helical island geometry, rotation measured by magnetic diagnostics, and equilibrium constraints from PSI-Tri reconstructions. Synthetic brightness signals are generated for each photodiode sightline from a modeled emissivity profile and directly compared with experimental data from a tangential midplane SXR array. By fitting the synthetic diagnostic output to the observed brightness across time, we simultaneously infer key geometric parameters-such as island radial location, island width, and rotation frequency-without requiring full tomographic reconstruction, all with an average absolute deviation of less than 3%. This work demonstrates that forward modeling with a single tangential array can extract key island parameters in a spherical tokamak, providing a computationally efficient alternative to conventional SXR tomography and providing a pathway toward real-time magnetic-island characterization in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling the 3-D structure of ignition experiments at the NIF

This study details a model used to infer the 3-D structure of the stagnated hot-spot and shell of inertial confinement fusion implosion experiments at the National Ignition Facility. The model assumes that 3-D low-mode drive perturbations can account for the majority of stagnation asymmetries experimentally observed. It uses an adaptive sampling algorithm to navigate the 24-D input parameter space to find a 3-D x-ray flux asymmetry whose application to an otherwise symmetric implosion results in a consistent match between synthetic and experimental diagnostic observables. The model is applied to a series of experiments and is able to achieve a consistent match for over 41 different observables, providing a high-fidelity reconstruction of the stagnation hot-spot and shell profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gyrokinetic profile prediction and validation of a negative triangularity plasma in ASDEX Upgrade

In this work, gyrokinetic simulations are performed with the CGYRO code (Candy et al 2016 J. Comput. Phys. 324 73–93) for a negative triangularity H-mode plasma in ASDEX Upgrade, and compared with experimental measurements. The PORTALS framework (Rodriguez-Fernandez et al 2024 Nucl. Fusion 64 076034) is used to accelerate the prediction of kinetic profiles for this plasma, using surrogate modeling and Bayesian optimization. Ion heat flux, electron heat flux, and electron particle flux are simultaneously matched across the simulated radial regime of the plasma (normalized radius $r/a = 0.35-0.90$), and the resulting ion temperature, electron temperature, and electron density profiles match well with the experimental profile data within this radial range. A synthetic Correlation Electron Cyclotron Emission diagnostic is applied to find well-matched electron temperature fluctuation properties between simulation and experiment. The flux-matched profiles provide a basis for investigation of the turbulence nature across the plasma radius, revealing the dominance of Trapped Electron Mode turbulence at $r/a = 0.35$, the dominance of Ion Temperature Gradient turbulence at $r/a = 0.55$, 0.75, and 0.83, and an instability boundary at $r/a = 0.90$.

gyrokinetic simulation↗

A Platform-Independent X-ray Diffraction Diagnostic for Phase Transition Kinetics in Traditional and Synthetic Microstructure Materials (LDRD Project 213088 Final Report)

Pulsed-power generators using the magnetic loading technique are able to produce well-controlled continuous ramp compression of condensed matter for high-pressure equation-of-state studies. X-ray diffraction (XRD) data from dynamically compressed samples provide direct measurements of the elastic compression of the crystal lattice, onset of plastic flow, strength-strain rate dependence, structural phase transitions, and density of crystal defects such as dislocations. Here, we present a cost effective, compact X-ray source for XRD measurements on pulsed-power-driven ramp-loaded samples. This combination of magnetically-driven ramp compression of materials with single, short-pulse XRD diagnostic will be a powerful capability for the dynamic materials community. The success in fielding this new XRD diagnostic dramatically improves our predictive capability and understanding of rate-dependent behavior at or near phase transition. As Sandia plans the next-generation pulse-power driver platform, a key element needed to deliver new state-of-the-art experiments will be having the necessary diagnostic tools to probe new regimes and phenomena. These diagnostics need to be as versatile, compact, and portable as they are powerful. The development of a platform-independent XRD diagnostic gives Sandia researchers a new window to study the microstructure and phase dynamics of materials under load. This project has paved the way for phase transition research in a variety of materials with mission interest.

36 MATERIALS SCIENCE↗

Optical design and synthetic analysis of the electron cyclotron emission imaging diagnostic of HL-2M tokamak

The electron cyclotron emission imaging (ECEI) diagnostic is a powerful tool to study the MHD and turbulent transport in magnetically confined fusion plasmas. In this work, the optical system including the local oscillator (LO) coupling and radio frequency (RF) receiving optics, has been designed and analyzed for the HL-2M ECEI diagnostic. The LO optics can illuminate the antenna array and drive the mixer diode to work efficiently, with more than 36% of the beam intensity for the channels which probe the plasma edge relative to those of channels which probe the plasma core. The RF optics aims at guiding the plasma emission signal to the antenna array. To meet different physical requirements, three types of field of view have been achieved for the plasma imaging, with zoom factors of around 1, 1.5 and 2, respectively. The focal surfaces are almost flat, with a maximum off-mapping (defined as the radial distance between the beam waists of the lower-/uppermost antennas and electron cyclotron emission layer) less than 2.5 cm, which can match the electron cyclotron emission layer quite well and suppress the image distortion in the plasma edge region. Furthermore, the impact of possible vibrations and installation error on the focal plane has been evaluated. In addition, the predefined MHD and turbulence perturbations are well reproduced by combining the optical simulation results and synthetic ECEI modeling, which further verifies the good performance of the RF optics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser absorption measurements of temperature, pressure, CO, and CO 2 at near-MHz rates in post-detonation fireballs with comparison to synthetic measurements

A laser absorption spectroscopy (LAS) diagnostic was used to obtain measurements of temperature, pressure, CO, and CO 2 at 500 kHz or 1 MHz in post-detonation fireballs produced by hemispherical samples of pentaerythritol tetranitrate (PETN). A quantum-cascade laser was scanned over multiple CO absorption transitions near 2008.5 cm −1 at 1 MHz, while an interband-cascade laser was scanned over a CO 2 absorption transition near 2394.8 cm −1 at 500 kHz. Light from each laser was combined onto a single path and passed through a detonation chamber approximately 83 mm above the 12-mm diameter hemispherical PETN charge. The CO and CO 2 absorption signals were post-processed to obtain time histories of temperature, pressure, species column pressures (P CO L, P CO2 L), and species column mole fractions (X CO L, X CO2 L). Additionally, schlieren imaging was performed simultaneously at 500 kHz to aid interpretation of the LAS measurements. Experimental and synthetic (i.e., CFD based) LAS measurements were compared to evaluate the accuracy of the CFD model and its ability to model the turbulent afterburning of the detonation products in air. In general, the experimental measurements exhibit reasonable agreement with the synthetic measurements at early times; thereby supporting the accuracy of the CFD model. Periods of disagreement between experimental and synthetic measurements at later times are most likely due to a reflected shock and detonator cavity jetting, which are not accounted for in the CFD model.

Schwartz, Charles J. [Purdue Univ., West Lafayette↗

Analysis of synthetic electron cyclotron emission from the high field side of HL-2M tokamak plasmas

A synthetic electron cyclotron emission (ECE) diagnostic is used to interpret ECE signals from preset plasma equilibrium profiles, including magnetic field, electron density, and electron temperature. According to the simulation results, the electron temperature (T e ) profile covering the harmonic overlap region can be obtained by receiving ECE signals at the high field side (HFS) of the HL-2M plasma. The third harmonic ECE at the low field side (LFS) cannot pass through the second harmonic resonance layer at the HFS unless the optical thickness (τ) of the second harmonic becomes gray (τ ≤ 2). In addition, the impact of the relativistic frequency down-shift has been evaluated and corrected. The measurable range of the HFS ECE has been calculated by scanning different parameters (electron density, temperature, and magnetic field). Higher plasma parameters allow a wider radial range of electron temperature measurements. The minimum inner measurable position can reach R = 120 cm (r/a = -0.89) when the product of core temperature (T e0 ) and density (n e0 ) is greater than 35 × 10 19 keV m -3 , which is extended by more than 30 cm inward compared with that of the LFS measurement. The HFS ECE will greatly improve the diagnostic ability of ECE systems on the HL-2M tokamak.

47 OTHER INSTRUMENTATION↗

Geometric optics model of Thomson scattering enhanced by parametric coupling

We formulate a theory of Thomson scattering (TS) from inhomogeneous plasmas using a ray-tracing approach. The scattered radiation is described within the eikonal approximation, including convective gain arising from scattering instabilities driven by the TS probe laser. In the limit of a weak probe and vanishing gain, the theory recovers the standard TS cross section and scattered power due to volumetric particle noise. The ray-tracing formalism is implemented in a TS fitting framework, enabling accurate analysis of inhomogeneous plasmas whose background profiles can be provided by large-scale hydrodynamic simulations or experimental diagnostics. Here, several examples of synthetic TS spectra are presented, and further extensions of the theory are discussed.

Carleton, D. E. [University of Alberta, Edmonton, ↗

An ultra-fast method for generating synthetic down-scattered neutron data for inertial confinement fusion implosions

In inertial confinement fusion experiments at the National Ignition Facility, asymmetries are probed by a variety of neutron diagnostics, including neutron imaging systems, real-time neutron activation diagnostics (RTNADs), and neutron spectrometers. It is often useful to generate synthetic data based on these diagnostics to validate and tune models. However, current methods of doing so using Monte Carlo particle tracing are time-consuming. In this paper, an ultra-fast method is presented for generating synthetic neutron images, RTNAD data, and spectrometry data using line integrals and 3D convolutions. While it does not contain as much physics as particle tracing codes, it is thousands of times faster and produces nearly identical data. This enables analysis techniques that depend on generating large amounts of synthetic data, which will prove very useful for the study of asymmetries going forward.

Deuterium↗

Comparison between mirror Langmuir probe and gas-puff imaging measurements of intermittent fluctuations in the Alcator C-Mod scrape-off layer

Statistical properties of the scrape-off layer plasma fluctuations are studied in ohmically heated plasmas in the Alcator C-Mod tokamak. For the first time, plasma fluctuations as well as parameters that describe the fluctuations are compared across measurements from a mirror Langmuir probe (MLP) and from gas-puff imaging (GPI) that sample the same plasma discharge. This comparison is complemented by an analysis of line emission time-series data, synthesized from the MLP electron density and temperature measurements. The fluctuations observed by the MLP and GPI typically display relative fluctuation amplitudes of order unity together with positively skewed and flattened probability density functions. Such data time series are well described by an established stochastic framework that models the data as a superposition of uncorrelated, two-sided exponential pulses. The most important parameter of the process is the intermittency parameter, $γ=τ_d/τ_w$, where τd denotes the duration time of a single pulse and $τ_w$ gives the average waiting time between consecutive pulses. In this study we show, using a new deconvolution method, that these parameters can be consistently estimated from different statistics of the data. We also show that the statistical properties of the data sampled by the MLP and GPI diagnostic are very similar. Finally, a synthetic GPI signal using only plasma parameters sampled by the MLP shows qualitatively different fluctuation statistics from the measured GPI signal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

From minimum-viable-products to full models: a step-wise development of diagnostic forward models in support of design, analysis and modelling on the ST40 tokamak

Like most magnetic confined fusion experiments, the ST40 tokamak started off with a small subset of diagnostics and gradually increased the diagnostic set to include more complex and comprehensive systems. To make the most of each operational phase, forward models of various diagnostics are used and developed to aid design, provide consistency-checks during commissioning, test analysis methods, and build workflows to constrain high-level parameters to inform interpretation, theory and modelling. For new models and new analysis workflows, minimum-viable-products are released early, and their complexity is increased in a step-wise manner, facilitating the support of all programme phases on multiple parallel applications, while enabling learning opportunities and feedback loops. In this contribution we review the philosophy, scope and architecture of the framework under development. We discuss the details of some forward models, with examples on how they are used to aid diagnostic design, to investigate analysis methodologies through synthetic data, and how they are embedded in experimental analysis workflows. We compare previously published experimental results with new, more advanced analysis workflows employing more recent, detailed models and new diagnostic data, providing confirmation of the published material from the 2021–22 experimental campaign.

integrated data analysis↗