Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “structural loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

High power testing of a fused quartz-based dielectric-loaded accelerating structure.

We report on the most recent results from a series of high power tests being carried out on rf-driven dielectric-loaded accelerating (DLA) structures. The purpose of these tests is to determine the viability of the DLA as a traveling-wave accelerator and is a collaborative effort between Argonne National Laboratory (ANL), Naval Research Laboratory (NRL), and Stanford Linear Accelerator Center (SLAC). In this paper, we report on the recent high power tests of a fused quartz-based DLA structure that was carried out at incident powers of up to 12 MW at NRL and 37 MW at SLAC. We also report on test results of a TiN coated quartz structure, that exhibits good multipactor suppression.

43 PARTICLE ACCELERATORS↗

Characterizing wind gusts in complex terrain

Abstract. Wind gusts are a key driver of aerodynamic loading, especially for tall structures such a bridges and wind turbines. However, gust characteristics in complex terrain are not well understood and common approximations used to describe wind gust behavior may not be appropriate at heights relevant to wind turbines and other structures. Data collected in the Perdigão experiment are analyzed herein to provide a foundation for improved wind gust characterization and process-level understanding of flow intermittency in complex terrain. High-resolution observations from sonic anemometers and vertically pointing Doppler lidars are used to conduct a detailed study of gust characteristics with a specific focus on the parent distributions of nine gust parameters (that describe velocity, time, and length scales), their joint distributions, height variation, and coherence in the vertical and horizontal planes. Best-fit distributional forms for varying gust properties show good agreement with those from previous experiments in moderately complex terrain but generate nonconservative estimates of the gust properties that are of key importance to structural loading. Probability distributions of gust magnitude derived from vertically pointing Doppler lidars exhibit good agreement with estimates from sonic anemometers despite differences arising from volumetric averaging and the terrain complexity. Wind speed coherence functions during gusty periods (which are important to structural wind loading) are similar to less complex sites for small vertical displacements (10 to 40 m), but do not exhibit an exponential form for larger horizontal displacements (800 to 1500 m).

Letson, Frederick (ORCID:0000000192750359)↗

Performance Modeling of a Variable-Geometry Oscillating Surge Wave Energy Converter on a Raised Foundation: Preprint

This paper analyzes the power capture potential, structural loadings, and costs associated with an oscillating surge wave energy converter (OSWEC) operating on a raised foundation. The raised OSWEC offers opportunities for reduced installation costs, improved energy production, and greater flexibility of deployment when compared with bottom-fixed models. In this investigation, several different foundation geometries were simulated using WEC-Sim to estimate power capture and structural loads. In an effort to maximize power capture, several cases in which flat plates of varying size were attached to the top of the foundation, under and parallel with the OSWEC, were also simulated. These plates were found to enhance power capture by preventing the wave induced pressure from passing underneath the OSWEC, diverting this pressure towards the OSWEC instead. The OSWEC was simulated in the six Wave Energy Prize sea states, which were chosen as a representative sample of U.S. deployment sites. A first-order estimate of structural costs was calculated using the Wave Energy Prize ACE metric, with the foundation comprised predominantly of steel-reinforced concrete and the OSWEC comprised of A36 steel. Influence of foundation geometry on power capture, structural loadings, and ACE are topics of particular interest. This work has been inspired by advances in large scale additive manufacturing techniques that have the potential to dramatically reduce the cost of subsea foundations. These advancements may enable cost effective WEC systems to be deployed on raised foundations.

50 EE - Wind and Water Power Program - Water (EE-4↗

Performance Modeling of a Variable-Geometry Oscillating Surge Wave Energy Converter on a Raised Foundation

This paper analyzes the power capture potential, structural loadings, and costs associated with an oscillating surge wave energy converter (OSWEC) operating on a raised foundation. The raised OSWEC offers opportunities for reduced installation costs, improved energy production, and greater flexibility of deployment when compared with fixed-bottom models. In this investigation, we simulated several different foundation geometries using WEC-Sim to estimate power capture and structural loads. In an effort to maximize power capture, several cases in which flat plates of varying size were attached to the top of the foundation, under and parallel with the OSWEC, were also simulated. These plates were found to enhance power capture by preventing the wave-induced pressure from passing underneath the OSWEC, diverting this pressure toward the OSWEC instead. The OSWEC was simulated in the six Wave Energy Prize sea states, which were chosen as a representative sample of U.S. deployment sites. A first-order estimate of structural costs was calculated using the Wave Energy Prize ACE metric, with the foundation comprised predominantly of steel-reinforced concrete and the OSWEC comprised of A36 steel. Influence of foundation geometry on power capture, structural loadings, and ACE are topics of particular interest. This work has been inspired by advances in large-scale additive manufacturing techniques that have the potential to dramatically reduce the cost of subsea foundations. These advancements may enable cost-effective WEC systems to be deployed on raised foundations.

cost↗

Wave Prediction using X-Band Radar (Final Summary Report)

Model Predictive Control (MPC) is the best controls framework available to wave energy today. It allows for the maximization of energy yield from a WEC system while respecting various constraints and losses in the system. This type of constrained optimization is a critical capability for the techno-economic optimization of WEC devices and is difficult to do effectively with causal controls frameworks. MPC requires a future prediction of wave excitation forces, requiring wave prediction on a future time horizon of up to 30 seconds. The future horizon required is highly dependent on the WEC and PTO type available. To our knowledge no-one has been able to implement MPC on a WEC device at sea, due to the fact that phase-resolved wave-prediction is not a capability that has been sufficiently developed to date. The key objectives of this project are focused on developing “industry-ready” wave prediction technology building blocks that can be applied to a wide range of different wave energy conversion topologies. Our collaborative work with device developers has demonstrated that the level of improvement attainable for any particular device is heavily dependent on the device and PTO topology chosen. The range of annual average power capture improvements is on the order of 10% to over 100%. However, the important aspect is that we can get within about 10% of theoretical upper limits even when considering errors in the wave prediction and more importantly, we can optimize performance while respecting various constraints such as motion amplitude or peak structural loads. The combination of improved performance while limiting structural loads has a net effect of reducing the levelized cost of energy from these emerging technologies and allows us to design control laws that meet an economic optimum. Efforts under a previous project on controls has focused on developing a set of wave-prediction algorithms that work by leveraging a network of wave sensing measurement buoys that are equipped with real-time telemetry. The present work is focusing primarily on using X-band radar to measure the wave-field around the WEC to predict the future excitation forces on the structure and combining the measurements of these different sources to create improvements in the wave-prediction accuracy.

16 TIDAL AND WAVE POWER↗

Efficient Loads Surrogates for Waked Turbines in an Array

Accurately and efficiently predicting wind turbine structural loading is a crucial step in wind farm design. Without considering structural loading, wind farm optimization could negatively impact turbine fatigue and ultimate loads, especially for waked and partially waked turbines, which could result in higher maintenance costs and reduced turbine lifetime. However, predicting turbine loads throughout an array is a costly step, as these quantities require time-accurate results across long time histories, which is often intractable for large array optimization. Therefore, surrogate models that link array spacing to load outputs are often used, but the surrogates are then unique to the inflow conditions and array configurations in the training library. This work develops surrogate models for many wind turbine load outputs based solely on rotor plane velocity measurements, with no required input about array configuration or freestream inflow parameters. Surrogate models were constructed for many turbine quantities of interest (QoI), considering mean, standard deviation, ultimate, and fatigue loads. In general, most QoI statistics were accurately captured, as measured by predicted vs. actual correlation coefficient, confirming the suitability of the approach. Temporal mean values of the QoI required only temporal mean measurements of the rotor plane inflow velocity. However, accurate prediction of temporal standard deviation, ultimate, and fatigue values of QoI also required temporal standard deviations of the rotor plane velocity field. Poor surrogate performance was observed when too many correlated inputs were used, such as multiple velocity components. If the fewest inflow parameters are used to construct the surrogates, the average correlation coefficient value for all output QoI statistics is 0.89. Surrogates for standard deviations and damage equivalent loads (DELs) of turbine QoIs generally had lower accuracy and tower-base and shaft load channels posed the most difficult to capture accurately. The results suggest that these surrogates could be easily paired with analytic wake models, which are frequently used for pre-construction wind farm array optimization, to account for turbine loading in addition to power production. By including the optimal inflow conditions, the surrogate accuracy can improve to an average correlation coefficient value for all output QoI statistics of 0.92. This work has established the ability to build accurate surrogates for mean, standard deviation, ultimate load, and DEL turbine QoI values based on the rotor plane inflow velocity, and identified which inflow conditions lead to greater surrogate accuracy.

17 WIND ENERGY↗

System-level design studies for large rotors

Abstract. We examine the effect of rotor design choices on the power capture and structural loading of each major wind turbine component. A harmonic model for structural loading is derived from simulations using the National Renewable Energy Laboratory (NREL) aeroelastic code FAST to reduce computational expense while evaluating design trade-offs for rotors with radii greater than 100 m. Design studies are performed, which focus on blade aerodynamic and structural parameters as well as different hub configurations and nacelle placements atop the tower. The effects of tower design and closed-loop control are also analyzed. Design loads are calculated according to the IEC design standards and used to create a mapping from the harmonic model of the loads and quantify the uncertainty of the transformation. Our design studies highlight both industry trends and innovative designs: we progress from a conventional, upwind, three-bladed rotor to a rotor with longer, more slender blades that is downwind and two-bladed. For a 13 MW design, we show that increasing the blade length by 25 m, while decreasing the induction factor of the rotor, increases annual energy capture by 11 % while constraining peak blade loads. A downwind, two-bladed rotor design is analyzed, with a focus on its ability to reduce peak blade loads by 10 % per 5° of cone angle and also reduce total blade mass. However, when compared to conventional, three-bladed, upwind designs, the peak main-bearing load of the upscaled, downwind, two-bladed rotor is increased by 280 %. Optimized teeter configurations and individual pitch control can reduce non-rotating damage equivalent loads by 45 % and 22 %, respectively, compared with fixed-hub designs.

17 WIND ENERGY↗

FAST.Farm load validation for single wake situations at alpha ventus

The main objective of the presented work is the validation of the simulation tool FAST.Farm for the calculation of power and structural loads in single wake situations; the basis for the validation is the measurement database of the operating offshore wind farm alpha ventus. The approach is described in detail and covers the calibration of the aeroelastic turbine model, transfer of environmental conditions to simulations, and comparison between simulations and adequately filtered measurements. It is shown that FAST.Farm accurately predicts power and structural load distributions over wind direction with discrepancies of less than 10 % for most of the cases compared to the measurements. Additionally, the frequency response of the structure is investigated, and it is calculated by FAST.Farm in good agreement with the measurements. In general, the calculation of fatigue loads is improved with a wake-added turbulence model added to FAST.Farm in the course of this study.

17 WIND ENERGY↗

Influence of Asymmetric Cyclic Loading on Structural Evolution and Deformation Behavior of Cu-5 at.% Zr Alloy: An Atomistic Simulation-Based Study

Molecular dynamics (MD) simulation-based studies of tensile test and structural evolution of Cu-5 at.% Zr alloy under asymmetric cyclic loading (i.e., ratcheting behavior) considering various stress ratios such as − 0.2, − 0.4 and − 0.6 for different temperatures, viz.≈ 100, 300 and 500 K have been performed using embedded atom model Finnis–Sinclair potential. According to obtained stress–strain response from MD calculation, Cu-5 at.% Zr alloy specimen is pristine in nature as sudden drop in stress just after yield stress and subsequent elastic type deformation are observed for this alloy. Predicted ratcheting strain by MD simulation for Cu-5 at.% Zr alloy varies from 4.5 to 5%. Significant increase in ratcheting strain has been observed with the increase in temperature. Slight reduction in crystallinity is identified at the middle of the each loading cycle from the performed radial distribution function analysis and cluster analysis.

36 MATERIALS SCIENCE↗

Utilization of Additive Manufacturing for the Rapid Prototyping of C-Band Radiofrequency Loads

Additive manufacturing is a versatile technique that shows promise in providing quick and dynamic manufacturing for complex engineering problems. Research has been ongoing into the use of additive manufacturing for potential applications in radiofrequency (RF) component technologies. Here, we present a method for developing an effective prototype load produced from 316L stainless steel on a direct metal laser sintering machine. The model was tested using simulation software to verify the validity of the design. The load structure was manufactured by an online digital manufacturing company, showing the viability of using easily accessible tools to manufacture RF structures. The produced load was able to produce an S11 value of −22.8 dB at a C-band frequency of 5.712 GHz while under a vacuum. In a high-power test, the load was able to terminate a peak power of 8.1 MW. The discussion includes future applications of the present method and how it will help to improve the implementation of future accelerator concepts.

36 MATERIALS SCIENCE↗

INVESTIGATION AND OPTIMIZATION OF A NEW COMPACT SUPERCONDUCTING CAVITY FOR DEFLECTING AND CRABBING APPLICATIONS

Deflecting and crabbing structures have many applications in current accelera?tor systems. The primary use of a deflecting cavity is to separate a single beam into multiple beams. A crabbing cavity enables the head-on collision at the inter?action point in particle colliders in order to increase the luminosity. The early uses of the deflecting structures have been in the early 1960s; these structures were disk loaded structures operating at room temperature. The crabbing structure which was installed at the KEK electron-positron collider was the first and only operational superconducting cavity of that kind. The most common design of superconduct?ing deflecting and crabbing cavities is a squashed-elliptical geometry operating in a TM110-like mode; at low frequencies these structures become challenging due to the large geometrical shapes. Recently, compact deflecting and crabbing structures have been studied for numerous accelerator applications not limited to deflecting or crabbing of beams, but also for beam diagnostics, emittance exchange etc. The rf?dipole design, which is presented here, has evolved from the parallel-bar design and is a new compact deflecting and crabbing design with attractive properties at low frequencies and is operating in a TE11-like mode. The parallel-bar design has been optimized into the rf-dipole design primarily to maximize the net deflection with low and balanced peak surface fields and also to maximize the shunt impedance. The geometries have also been modified to increase the separation between the higher or?der modes, suppress multipacting conditions and reduce multipole components. The design geometries have been improved for mechanical stability in order to withstand thermal and pressure fluctuations under operating conditions. Two superconducting rf-dipole deflecting and crabbing cavities have been designed and optimized at 499 MHz for the Jefferson Lab 12 GeV Upgrade and at 400 MHz for a crabbing cavity for the LHC Luminosity Upgrade. The design optimization, fabrication, and test results of the first prototypes of both designs are presented in detail.

De Silva, Subashini Uddika↗

Using Post-tensioning in Large Scale Additive Parts for Load Bearing Structures

One of the perennial problems with additive manufacturing (AM) is the lack of inter-laminar bond strength between the layers, also known as z-strength. This can make the use of AM fabricated parts in load bearing applications problematic. This problem can be solved in some applications with post-tensioning. The use of post-tensioning in structures can be used to ensure that layer interfaces only see compressive stresses. This method is commonly used to strengthen concrete structures since concrete is weak in tension while strong in compression. This paper explores the successful application of post-tensioning to improve z-strength of large structures made with Big Area Additive Manufacturing (BAAM) where loads are significant. Theory and examples are presented herein.

Chesser, Phillip↗

Load monitoring and compensation strategies for guided-waves based structural health monitoring using piezoelectric transducers

Accurate interpretation of in-situ piezoelectric sensor signals is a challenging task. This article presents the development of a numerical compensation model based on physical insight to address the influence of structural loads on piezo-sensor signals. The model requires knowledge of in-situ strain and temperature distribution in a structure while acquiring sensor signals. The parameters of the numerical model are obtained using experiments on flat aluminum plate under uniaxial tensile loading. It is shown that the model parameters obtained experimentally can be used for different structures, and sensor layout. Furthermore, the combined effects of load and temperature on the piezo-sensor response are also investigated and it is observed that both of these factors have a coupled effect on the sensor signals. It is proposed to obtain compensation model parameters under a range of operating temperatures to address this coupling effect. An important outcome of this study is a new load monitoring concept using in-situ piezoelectric sensor signals to track changes in the load paths in a structure.

environmental compensation↗

Used Nuclear Fuel Loading and Structural Performance Under Normal Conditions of Transport - Modeling, Simulation and Experimental Integration RD&D Plan

Under current U.S. Nuclear Regulatory Commission regulation, it is not sufficient for used nuclear fuel (UNF) to simply maintain its integrity during the storage period, it must maintain its integrity in such a way that it can withstand the physical forces of handling and transportation associated with restaging the fuel and moving it to treatment or recycling facilities, or a geologic repository. Hence it is necessary to understand the performance characteristics of aged UNF cladding and ancillary components under loadings stemming from transport initiatives. Researchers would like to demonstrate that enough information, including experimental support and modeling and simulation capabilities, exists to establish a preliminary determination of UNF structural performance under normal conditions of transport (NCT). This research, development and demonstration (RD&D) plan describes a methodology, including development and use of analytical models, to evaluate loading and associated mechanical responses of UNF rods and key structural components. This methodology will be used to provide a preliminary assessment of the performance characteristics of UNF cladding and ancillary components under rail-related NCT loading. The methodology couples modeling and simulation and experimental efforts currently under way within the Used Fuel Disposition Campaign (UFDC). The methodology will involve limited uncertainty quantification in the form of sensitivity evaluations focused around available fuel and ancillary fuel structure properties exclusively. The work includes collecting information via literature review, soliciting input/guidance from subject matter experts, performing computational analyses, planning experimental measurement and possible execution (depending on timing), and preparing a variety of supporting documents that will feed into and provide the basis for future initiatives. The methodology demonstration will focus on structural performance evaluation of Westinghouse WE 17×17 pressurized water reactor fuel assemblies with a discharge burnup range of 30-58 GWd/MTU (assembly average), loaded in a representative high-capacity (≥32 fuel rod assemblies) transportation package. Evaluations will be performed for representative normal conditions of rail transport involving a rail conveyance capable of meeting the Association of American Railroads (AAR) S-2043 specification. UNF modeling is anticipated to be defined to the pellet-cladding level and take in to account influences associated with spacer grids, intermediate fluid mixers, and control components. The influence of common degradation issues such as ductile-to-brittle-transition will also be accounted for. All model development and analysis will be performed with commercially available software packages exclusively. Inputs and analyses will be completely documented, all supporting information will be traceable, and bases will be defendable so as to be most useful to the U.S. Department of Energy community and mission. The expected completion date is the end of fiscal year (FY) 2013.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Used Nuclear Fuel Loading and Structural Performance Under Normal Conditions of Transport- Demonstration of Approach and Results on Used Fuel Performance Characterization

This document addresses Oak Ridge National Laboratory milestone M2FT-13OR0822015 Demonstration of Approach and Results on Used Nuclear Fuel Performance Characterization. This report provides results of the initial demonstration of the modeling capability developed to perform preliminary deterministic evaluations of moderate-to-high burnup used nuclear fuel (UNF) mechanical performance under normal conditions of storage (NCS) and normal conditions of transport (NCT) conditions. This report also provides results from the sensitivity studies that have been performed. Finally, discussion on the long-term goals and objectives of this initiative are provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Studying Wind Loading on CSP Collectors to Improve Performance and Reliability

Electricity generation through Concentrating Solar-thermal Power (CSP) adds the advantage of thermal energy storage and heat production. CSP collector costs constitute nearly one-third of total plant costs. Managing wind loading, especially dynamic wind loading caused by the turbulent wind flow, is a significant design challenge. Traditional collector designs rely on wind tunnel experiments and numerical simulations, which do not fully capture dynamic effects. Here, we provide an overview of NREL's activities on wind loading on CSP collectors, aiming to improve their reliability and cost-efficiency. We present insights from field measurements at operational parabolic trough and power-tower CSP plants. Over two years, we measured turbulent wind fields and resulting structural loads in a parabolic trough plant, revealing wind, turbulence, and collector field interactions. Similar measurements are ongoing at the Crescent Dunes heliostat field. These campaigns show how atmospheric turbulence, wind direction, and collector orientation affect dynamic wind loading. Upwind collector structures can generate turbulent structures, causing fluctuating loads at downstream collectors, impacting fatigue lifetime and optical efficiency. Preliminary results indicate that interior collectors experience higher turning moments than those at the edges, suggesting higher drive wear. At Crescent Dunes, we use instrumented heliostats at the field's edge and interior to study the translation of turbulent wind to dynamic structural loads. The campaign is still ongoing, and we will present first findings. Another focus of our work is tying the experimental wind loading findings to optical performance of the collectors, using simulation tools. For example, we derive torsional errors of the parabolic troughs - the angular offset from the sun position along a collector row. This error is impacted by wind-induced mirror deformations. Future work will focus on continuing the measurement efforts and combining them with computational fluid dynamic simulations. By providing detailed field measurements and validated models, our efforts aim to enhance understanding of wind loading on CSP collectors, improving their structural integrity and optical performance.

CSP↗

Balancing the Power-to-Load Ratio for a Novel Variable Geometry Wave Energy Converter with Nonideal Power Take-Off in Regular Waves: Preprint

This work attempts to balance power absorption against structural loading for a novel variable geometry wave energy converter. The variable geometry consists of four identical flaps that will be opened in ascending order starting with the flap closest to the seafloor and moving to the free surface. The influence of a pitch motion constraint on power absorption when utilizing a nonideal power take-off (PTO) is examined and found to reduce the losses associated with bidirectional energy flow. The power-to-load ratio is evaluated using pseudo-spectral control to determine the optimum PTO torque based on a multiterm objective function. The pseudo-spectral optimal control problem is extended to include load metrics in the objective function, which may now consist of competing terms. Separate penalty weights are attached to the surge-foundation force and PTO control torque to tune the optimizer performance to emphasize either power absorption or load shedding. PTO efficiency is not included in the objective function, but the penalty weights are utilized to limit the force and torque amplitudes, thereby reducing losses associated with bidirectional energy flow. Results from pseudo-spectral control demonstrate that shedding a portion of the available wave energy can provide greater reductions in structural loads and reactive power.

16 TIDAL AND WAVE POWER↗

Benchmarking of three DWM-based wake models at below-rated wind speeds

Wind turbine wake models are essential tools for predicting power losses and structural loads in wind farms. Among these, the dynamic wake meandering (DWM) model, included as a recommended approach in the International Electrotechnical Commission design standard, is a widely used engineering-fidelity method that balances accuracy and computational cost. This study compares the performance of three DWM-based wake model implementations (from the Technical University of Denmark, the National Renewable Energy Laboratory, and the Institute for Energy Technology) under below-rated wind speed conditions. Model predictions of wake flow, power output, and structural loads for a four-turbine row are evaluated across different ambient turbulence levels and wind-direction misalignments and compared against high-fidelity large-eddy simulation results. All three models captured the overall wake evolution and mean turbine performance with reasonable accuracy; their predicted time-averaged thrust and power were typically within 5 %–10 % of the large-eddy simulation benchmark. However, notable differences emerged in wake structure and unsteady load predictions, with discrepancies increasing for turbines further downstream. These differences highlight the importance of modelling choices such as wake summation and turbulence treatment, which strongly influence power-deficit and fatigue-load predictions. Comparison with large-eddy simulations reveals each approach's strengths and weaknesses, indicating where improvements are needed. Overall, the findings point to specific refinements for DWM models to improve their fidelity, ultimately enabling more robust wake predictions for wind farm design and operation.

17 WIND ENERGY↗