Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “standoff”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Water driven turbine/brush pipe cleaner

Assemblies are disclosed for cleaning the inside walls of pipes and tubes. A first embodiment includes a small turbine with angled blades axially mounted on one end of a standoff support. An O-ring for stabilizing the assembly within the pipe is mounted in a groove within the outer ring. A replaceable circular brush is fixedly mounted on the opposite end of the standoff support and can be used for cleaning tubes and pipes of various diameters, lengths and configurations. The turbine, standoff support, and brush spin in unison relative to a hub bearing that is fixedly attached to a wire upstream of the assembly. The nonrotating wire is for retaining the assembly in tension and enabling return of the assembly to the pipe entrance. The assembly is initially placed in the pipe or tube to be cleaned. A pressurized water or solution source is provided at a required flow-rate to propel the assembly through the pipe or tube. The upstream water pressure propels and spins the turbine, standoff support and brush. The rotating brush combined with the solution cleans the inside of the pipe. The solution flows out of the other end of the pipe with the brush rotation controlled by the flow-rate. A second embodiment is similar to the first embodiment but instead includes a circular shaped brush with ring backing mounted in the groove of the exterior ring of the turbine, and also reduces the size of the standoff support or eliminates the standoff support.

Werlink, Rudy J.↗

AOTV bow shock location

Hypersonic bow-shock location and geometry are of central importance to the aerodynamics and aerothermodynamics of aeroassisted orbital transfer vehicles (AOTVs), but they are difficult to predict for a given vehicle configuration. This paper reports experimental measurements of shock standoff distance for the 70 deg cone AOTV configuration in shock-tunnel-test flows at Mach numbers of 3.8 to 7.9 and for angles of attack from 0 deg to 20 deg. The controlling parameter for hypersonic bow-shock standoff distance (for a given forebody shape) is the mean normal-shock density ratio. Values for this parameter in the tests reported are in the same range as those of the drag-brake AOTV perigee regime. Results for standoff distance are compared with those previously reported in the literature for this AOTV configuration. It is concluded that the AOTV shock standoff distance for the conical configuration, based on frustrum (base) radius, is equivalent to that of a sphere with a radius about 35 percent greater than that of the cone; the distance is, therefore, much less than reported in previous studies. Some reasons for the discrepancies between the present and previous are advanced. The smaller standoff distance determined here implies there will be less radiative heat transfer than was previously expected.

Desautel, D.↗

Numerical Viscous Flow Analysis of an Advanced Semispan Diamond-Wing Model at High-Life Conditions

Turbulent Navier-Stokes computational results are presented for an advanced diamond wing semispan model at low speed, high-lift conditions. The numerical results are obtained in support of a wind-tunnel test that was conducted in the National Transonic Facility (NTF) at the NASA Langley Research Center. The model incorporated a generic fuselage and was mounted on the tunnel sidewall using a constant width standoff. The analyses include: (1) the numerical simulation of the NTF empty, tunnel flow characteristics; (2) semispan high-lift model with the standoff in the tunnel environment; (3) semispan high-lift model with the standoff and viscous sidewall in free air; and (4) semispan high-lift model without the standoff in free air. The computations were performed at conditions that correspond to a nominal approach and landing configuration. The wing surface pressure distributions computed for the model in both the tunnel and in free air agreed well with the corresponding experimental data and they both indicated small increments due to the wall interference effects. However, the wall interference effects were found to be more pronounced in the total measured and the computed lift, drag and pitching moment due to standard induced up-flow effects. Although the magnitudes of the computed forces and moment were slightly off compared to the measured data, the increments due the wall interference effects were predicted well. The numerical predictions are also presented on the combined effects of the tunnel sidewall boundary layer and the standoff geometry on the fuselage fore-body pressure distributions and the resulting impact on the overall configuration longitudinal aerodynamic characteristics.

Ghaffari, F.↗

Quantifying Thermal Output of Energetic Materials (LDRD Final Report)

We present the results of an LDRD project, funded by the Nuclear Deterrence IA, to develop capabilities for quantitative assessment of pyrotechnic thermal output. The thermal battery igniter is used as an exemplar system. Experimental methodologies for thermal output evaluation are demonstrated here, which can help designers and engineers better specify pyrotechnic components , provide thermal output guidelines for new formulations, and generate new metrics for assessing component performance and margin given a known failure condition. A heat-transfer analysis confirms that the dominant mode of energy transfer from the pyrotechnic output plume to the heat pellet is conduction via deposition of hot titanium particles. A simple lumped-parameter model of titanium particle heat transfer and a detailed multi-phase model of deposition heat transfer are discussed. Pyrotechnic function, as defined by "go/no-go" standoff testing of a heat pellet, is correlated with experimentally measured igniter plume temperature, titanium metal particle temperature, and energy deposition. Three high-speed thermal diagnostics were developed for this task. A three-color imaging pyrometer, acquiring 100k images per second on three color channels, is deployed for measurement of titanium particle temperatures. Complimentary measurements of the overall igniter plume emission ("color") temperature were conducted using a transmission-grating spectrograph in line-imaging mode. Heat flux and energy deposition to a cold wall at the heat-pellet location were estimated using an eroding thermocouple probe, with a frequency response of ~5 kHz. Ultimate "go/no-go" function in the igniter/heat-pellet system was correlated with quantitative thermal metrics, in particular surface energy deposition and plume color temperature. Titanium metal-particle and plume color temperatures both experience an upper bound approximated by the 3245-K boiling point of TiO 2 . Average metal-particle temperatures remained nearly constant for all standoff distances at T = 2850 K, ± 300 K, while plume color temperature and heat flux decay with standoff—suggesting that heat-pellet failure results from a drop in metal-particle flux and not particle temperature. At 50% likelihood of heat-pellet failure, peak time-resolved plume color temperatures drop well below TiO 2 boiling to ~2000 - 2200 K, near the TiO 2 melting point. Estimates of peak heat flux decline from up to 1 GW/m 2 for near-field standoffs to below 320 MW/m 2 at 50% failure likelihood.

36 MATERIALS SCIENCE↗

Unusual locations of Earth's bow shock on September 24 - 25, 1987: Mach number effects

International Sun Earth Explorer 1 (ISEE 1) and Interplanetary Monitoring Platform 8 (IMP 8) data are used to identify 19 crossings of Earth's bow shock during a 30-hour period following 0000 UT on September 24, 1987. Apparent standoff distances for the shock are calculated for each crossing using two methods and the spacecraft location; one method assumes the average shock shape, while the other assumes a ram pressure-dependent shock shape. The shock's apparent standoff distance, normally approximately 14 R(sub E), is shown to increase from near 10 R(sub E) initially to near 19 R(sub E) during an 8-hour period, followed by an excursion to near 35 R(sub E) (where two IMP 8 shock crossings occur) and an eventual return to values smaller than 19 R(sub E). The Alfven M(sub A) and fast magnetosonic M(sub ms). Mach numbers remain above 2 and the number density above 4/cu cm for almost the entire period. Ram pressure effects produce the initial near-Earth shock location, whereas expansions and contractions of the bow shock due to low Mach number effects account, qualitatively and semiquantitatively, for the timing and existence of almost all the remaining ISEE crossings and both IMP 8 crossings. Significant quantitative differences exist between the apparent standoff distances for the shock crossings and those predicted using the observed plasma parameters and the standard model based on Spreiter et al.'s (1966) gasdynamic equation. These differences can be explained in terms of either a different dependence of the standoff distance on Mach number at low M(sub A) and M(sub ms), or variations in shock shape with M(sub A) and M(sub ms) (becoming increasingly "puffed up" with decreasing M(sub A) and M(sub ms), as expected theoretically), or by a combination of both effects.

Cairns, Iver H.↗

Potential for EMU Fabric Damage by Electron Beam and Molten Metal During Space Welding for the International Space Welding Experiment

As a consequence of preparations concerning the International Space Welding Experiment (ISWE), studies were performed to better understand the effect of molten metal contact and electron beam impingement with various fabrics for space suit applications. The question arose as to what would occur if the electron beam from the Ukrainian Universal Hand Tool (UHT) designed for welding in space were to impinge upon a piece of Nextel AF-62 ceramic cloth designed to withstand temperatures up to 1427 C. The expectation was that the electron beam would lay down a static charge pattern with no damage to the ceramic fabric. The electron beam is capable of spraying the fabric with enough negative charge to repel further electrons from the fabric before significant heating occurs. The static charge pattern would deflect any further charge accumulation except for a small initial amount of leakage to the grounded surface of the welder. However, when studies were made of the effect of the electron beam on the insulating ceramic fabric it was surprisingly found that the electron beam did indeed burn through the ceramic fabric. It was also found that the shorter electron beam standoff distances had longer burnthrough times than did some greater electron beam standoff distances. A possible explanation for the longer burnthrough times for the small electron beam standoff distance would be outgassing of the fabric which caused the electron beam hand-tool to cycle on and off to provide some protection for the cathodes. The electron beam hand tool was observed to cycle off at the short standoff distance of two inches likely due to vapors being outgassed. During the electron beam welding process there is an electron leakage, or current leakage, flow from the fabric. A static charge pattern is initially laid down by the electron beam current flow. The static charge makes up the current leakage flow which initially slightly heats up the fabric. The initially laid down surface charge leaks a small amount of current. The rate at which the current charge leaks from the fabric controls how fast the fabric heats up. As the ceramic fabric is heated it begins to outgass primarily from contamination/impurities atoms or molecules on and below the fabric surface. The contaminant gases ionize to create extra charge carriers and multiply a current of electrons. The emitted gas which ionized in the electron leakage flow promotes further leakage. Thus, the small leakage of charge from the fabric surface is enhanced by outgassing. When the electron beam current makes up the lost current, the incoming electrons heat the fabric and further enhance the outgassing. The additional leakage promotes additional heating up of the ceramic fabric. The electrons bound to the ceramic fabric surface leak off more and more as the surface gets hotter promoting even greater leakage. The additional electrons that result also gain energy in the field and produce further electrons. Eventually the process becomes unstable and accelerates to the point where a hole is burned through the fabric.

Fragomeni, James M.↗

System for Controlling the Stirring Pin of a Friction Stir Welding Apparatus

A control is provided for a friction stir welding apparatus comprising a pin tool which includes a shoulder and a rotating pin extending outwardly from the shoulder of the pin tool and which, in use, is plunged into a workpiece formed contacting workpiece members to stir weld the members together. The control system controls the penetration of the pin tool into the workpiece members which are mounted on a support anvil. The control system includes a pin length controller for controlling pin length relative to the shoulder and for producing a corresponding pin length signal. A pin force sensor senses the force being exerted on the pin during welding and produces a corresponding actual pin force signal. A probe controller controls a probe extending outwardly from the pin, senses a parameter related to the distance between the probe and the supporting anvil and produces a corresponding probe signal. A workpiece standoff sensor senses the standoff distance between the workpiece and the standoff sensor and produces a corresponding standoff signal. A control unit receives the various signals, together with a weld schedule, and, based on these signals and the weld schedule, controls the pin length controller so as to control pin penetration into the workpiece.

Ding, R. Jeffrey↗

Close roof-mounted system temperature estimation for compliance to IEC TS 63126

When photovoltaic (PV) modules are installed on rooftops, the module temperature depends primarily on the geographic location and the mounting configuration. If the mounting structure does not provide sufficient airflow in a hot environment, the 98th percentile temperature will exceed 70°C, which according to IEC TS 63126 ED. 1, requires higher levels of thermal stability testing. However, there is no clear way to determine the temperature level needed for a particular location and system design. Here, in this work, we identify a relationship between the module standoff to the rooftop and the module temperature and propose methods to describe a minimum standoff for typical PV modules in a simple mounting configuration installed in a given location. For more complex system designs, we show how to determine an equivalent “effective standoff” that can be applied to generic calculations. Lastly, we show measurements and calculations from several systems to demonstrate how this method could work.

14 SOLAR ENERGY↗

Solar cycle variations in the size and shape of the magnetopause

The 10 years of the ISEE 1 and 2 mission covering much of solar cycle 21 and the beginning of solar cycle 22 make it possible to study the position, shape, and motion of the magnetopause throughout the course of changing solar activity. The size and shape of the magnetopause were determined for each observing season using the ISEE 1 and 2 magnetometer data IMP 8 data were used to monitor the solar wind changes with the solar cycle. During the 1979-1980 season, at solar maximum, the solar wind dynamic pressure was at its lowest values, and, at solar minimum, the solar wind pressure was at its largest values, more than double the value in the 1979-1980 season. During this solar cycle, the magnetopause was about 0.5 R(E) farther when the interplanetary magnetic field (IMF) was strongly northward, than when strongly southward. Both standoff distance values are fround to be smaller than the value found by Fairfield (1971). The standoff distance of the magnetopause for northward IMF is anticorrelated with the solar wind pressure. However, the standoff distance for southward IMF seems relatively insensitive to solar wind dynamic pressure.

Petrinec, S. P.↗

Simultaneous Ice Water Content Measurements at Multiple Locations on the NASA DC-8 Aircraft during the 2018 HIWC RADAR Flight Campaign

Ice water content measurements were made simultaneously at three locations on the NASA DC-8 in natural, glaciated conditions during the 2018 High Ice Water Content RADAR flight campaign. The purpose of these measurements was to further evaluate efficiency factors of hot-wire total water content probes in glaciated conditions and investigate the enhancement of ice crystal concentrations near fuselage surfaces due to flow field inertial effects, and ice crystals impacting the nose, breaking up, and flowing downstream. The total water content measurements were made using either Science Engineering Associates Ice Crystal Detectors or Robust Probes. Three common sensors were mounted on an underwing canister considered to be in near free-flow conditions, a standoff from a fuselage window, and the nose of the fuselage near the pitot probes. The Ice Crystal Detector total water content sensor and Robust Probe sensor collection and retention efficiencies were evaluated through comparisons with the underwing Ice Crystal Detector and Robust Probe measurements to the IKP2 isokinetic evaporator probe, which provided the reference ice water content measurement. Local ice water content at the nose position was evaluated by comparing ratios of the nose and underwing ice crystal detectors to the IKP2. Local ice water content at the window-standoff location was also evaluated by comparing total water content sensor measurements from the window ice crystal detector to the measurements made with the underwing and nose Ice Crystal Detectors The key findings were: 1) the Ice Crystal Detector total water content sensor ice water content efficiency factor was similar to previous estimates, but reduced with increased ice crystal median mass diameter; 2) the ice water content at the fuselage nose location near the DC-8 pitot probes was approximately 2.5 times the freestream values – although this estimate is affected by a higher probe efficiency factor due to smaller particles in the debris cloud from impacts upstream of the probe; and 3) the ice water content at the 17” standoff from the port window varied from about 50% to 3 times freestream values in a complicated manner. Similar measurement locations are not uncommon on cloud research aircraft, where ice particle measurements may be subject to similar uncertainties.

Aircraft Icing↗

Simultaneous Ice Water Content Measurements at Multiple Locations on the NASA DC-8 Aircraft during the 2018 HIWC RADAR Flight Campaign

Ice water content measurements were made simultaneously at three locations on the NASA DC-8 in natural, glaciated conditions during the 2018 High Ice Water Content RADAR flight campaign. The purpose of these measurements was to further evaluate efficiency factors of hot-wire total water content probes in glaciated conditions and investigate the enhancement of ice crystal concentrations near fuselage surfaces due to flow field inertial effects, and ice crystals impacting the nose, breaking up, and flowing downstream. The total water content measurements were made using either Science Engineering Associates Ice Crystal Detectors or Robust Probes. Three common sensors were mounted on an underwing canister considered to be in near free-flow conditions, a standoff from a fuselage window, and the nose of the fuselage near the pitot probes. The Ice Crystal Detector total water content sensor and Robust Probe sensor collection and retention efficiencies were evaluated through comparisons with the underwing Ice Crystal Detector and Robust Probe measurements to the IKP2 isokinetic evaporator probe, which provided the reference ice water content measurement. Local ice water content at the nose position was evaluated by comparing ratios of the nose and underwing ice crystal detectors to the IKP2. Local ice water content at the window-standoff location was also evaluated by comparing total water content sensor measurements from the window ice crystal detector to the measurements made with the underwing and nose Ice Crystal Detectors The key findings were: 1) the Ice Crystal Detector total water content sensor ice water content efficiency factor was similar to previous estimates, but reduced with increased ice crystal median mass diameter; 2) the ice water content at the fuselage nose location near the DC-8 pitot probes was approximately 2.5 times the freestream values – although this estimate is affected by a higher probe efficiency factor due to smaller particles in the debris cloud from impacts upstream of the probe; and 3) the ice water content at the 17” standoff from the port window varied from about 50% to 3 times freestream values in a complicated manner. Similar measurement locations are not uncommon on cloud research aircraft, where ice particle measurements may be subject to similar uncertainties.

o Aircraft Icing↗

The Effect of Reduced Pressure on the Characteristics of Spreading Flames

Flame spread over solid fuels is a canonical problem in fire science, due to its direct implications on material flammability and importance in fire development. In a microgravity environment, such as onboard a spacecraft, flames can behave very differently than on Earth. This is concerning for spaceflight life safety, especially in higher-oxygen environments. Due to the difficulties associated with microgravity testing, low-pressure environments have been proposed as an alternative to approximately replicate the burning behavior of solid fuels observed in reduced gravity conditions because of similar diffusion and heat transfer mechanisms. However, the roles played by gravity and pressure on flame length, standoff distance, and flame spread rate vary with the burning configuration. In concurrent flame spread, the buoyant flow enhances the spread rate by bringing the flame closer to the fuel surface and increasing the heating of the solid fuel. In opposed flame spread, the sample is preheated by the flame ahead of the flame leading edge, which is strongly affected by the surrounding flow field. In this work, we consider flames spreading over thin cotton samples in both downward (opposed) and upward (concurrent) configurations to investigate the effect of pressure (30-100 kPa) on flame characteristics, such as spread rate and standoff distance. A small forced flow is induced upward so that the flames are exposed to a mixed (forced and free) flow. By reducing pressure, flames become less bright, their standoff distance increases, and their spread rates decrease similar to what is observed in low-gravity environments. These results could in help understanding the differences between flames spreading at low pressure and low gravity environments for these similar, yet very different, spreading configurations. They could also provide more information about potential Earth-based flammability testing of materials for spacecraft applications.

fire safety↗

The effect of reduced pressure on the characteristics of spreading flames

Flame spread over solid fuels is a canonical problem in fire science, due to its direct implications on material flammability and importance in fire development. In a microgravity environment, such as onboard a spacecraft, flames can behave very differently than on Earth. This is concerning for spaceflight life safety, especially in higher-oxygen environments. Due to the difficulties associated with microgravity testing, low-pressure environments have been proposed as an alternative to approximately replicate the burning behavior of solid fuels observed in reduced gravity conditions because of similar diffusion and heat transfer mechanisms. However, the roles played by gravity and pressure on flame length, standoff distance, and flame spread rate vary with the burning configuration. In concurrent flame spread, the buoyant flow enhances the spread rate by bringing the flame closer to the fuel surface and increasing the heating of the solid fuel. In opposed flame spread, the sample is preheated by the flame ahead of the flame leading edge, which is strongly affected by the surrounding flow field. In this work, we consider flames spreading over thin cotton samples in both downward (opposed) and upward (concurrent) configurations to investigate the effect of pressure (30-100 kPa) on flame characteristics, such as spread rate and standoff distance. A small forced flow is induced upward so that the flames are exposed to a mixed (forced and free) flow. By reducing pressure, flames become less bright, their standoff distance increases, and their spread rates decrease similar to what is observed in low-gravity environments. These results could in help understanding the differences between flames spreading at low pressure and low gravity environments for these similar, yet very different, spreading configurations. They could also provide more information about potential Earth-based flammability testing of materials for spacecraft applications.

fire safety↗

Simultaneous Ice Water Content Measurements at Multiple Locations on the NASA DC-8 Aircraft during the 2018 HIWC RADAR Flight Campaign

Ice water content measurements were made simultaneously at three locations on the NASA DC-8 in natural, glaciated conditions during the 2018 High Ice Water Content RADAR flight campaign. The purpose of these measurements was to further evaluate efficiency factors of hot-wire total water content probes in glaciated conditions and investigate the enhancement of ice crystal concentrations near fuselage surfaces due to flow field inertial effects, and ice crystals impacting the nose, breaking up, and flowing downstream. The total water content measurements were made using either Science Engineering Associates Ice Crystal Detectors or Robust Probes. Three common sensors were mounted on an underwing canister considered to be in near free-flow conditions, a standoff from a fuselage window, and the nose of the fuselage near the pitot probes. The Ice Crystal Detector concave total water content sensor and Robust Probe sensor collection and retention efficiencies were evaluated through comparisons with the underwing Ice Crystal Detector and Robust Probe measurements to the Isokinetic Probe version 2 (IKP2), which provided the reference ice water content measurement. Local ice water content at the nose position was evaluated by comparing ratios of the nose and underwing ice crystal detectors to the IKP2. Local ice water content at the window-standoff location was also evaluated by comparing total water content sensor measurements from the window probes to the measurements made with the underwing and nose probes. The key findings were: (1) the Ice Crystal Detector concave water content sensor efficiency factor to glaciated conditions was similar to previous estimates, but reduced with increased ice crystal median mass diameter; (2) the ice water content at the fuselage nose location near the DC-8 pitot probes was approximately 2.5 times the freestream values—although this estimate is affected by a higher probe efficiency factor due to smaller particles in the debris cloud from impacts upstream of the probe; and (3) the ice water content at the 17 in. standoff from the port window varied from about 50 percent to nearly three times freestream values in a complicated manner. Similar measurement locations are not uncommon on cloud research aircraft, where ice particle measurements may be subject to similar uncertainties.

Aircraft Icing↗

A Wall-Modeled LES Perspective for the High Lift Common Research Model Using LAVA

A new immersed boundary Wall-Modelled Large Eddy Simulation (WMLES) formulation is developed to study high-lift aerodynamics on the NASA High-Lift Common Research Model (HL-CRM). A sequence of Cartesian Octree grids with sizes ranging from 100 Million through 2.02 Billion grid points is utilized to systematically assess grid-sensitivity and convergence for the in-tunnel (QinetiQ) configuration of the model, and remarkable agreement between the immersed boundary and the curvilinear body-aligned WMLES formulations is reported on grids with comparable resolutions. In the free-air configuration of the model, consistent predictions between the Curvilinear Overset and the Cartesian Octree formulations are reported for angles of attack up to C(L,max) at a=19.57. However, some differences in the onset of stall are seen between the two methods for a>20°: while the curvilinear WMLES experiences wing-root separation with increasing angle of attack (Topology A), the Cartesian Octree formulation shows a different flow topology characterized by boundary layer weakness on the main element, emanating from the pylon-wing attachment (Topology B). In order to obtain further insight into the two-distinct topologies, carefully designed numerical experiments to isolate effects of the model standoff and the tunnel wall-boundary layers are conducted using the immersed boundary WMLES formulation. The increased incidence angle-of-attack on the inboard portion of the wing due to the standoff is shown to be sufficient for triggering a switch from Topology B to Topology A in Cartesian WMLES. The role of the floor boundary layer is further examined in detail by identification of additional corner-flow vorticity generated by the viscous juncture flow interactions between the floor boundary layer and the standoff leading to formation of a strong coherent and persistent vortex on the belly-side of the fuselage. The intensity of this vortex is shown to increase with the thickness of the floor boundary layer. A further increase in the incidence angle of attack near the leading-edge strake caused by the presence of this belly-side vortex is quantified for two-distinct floor boundary layers. Both of the floor boundary layers considered result in the onset of large scale wing-root separation at a=21.47in non-confined (free-air) configurations.

TTT↗

High-voltage insulator having multiple materials

High-voltage insulators are disclosed that are capable of handling diverse requirements, such as providing high standoff voltages, high temperature cycling, and the ability to withstand flexural stress. One high-voltage insulator includes a first piece formed from a first material, a second piece formed from a second material, and an interface section where the first piece contacts with and forms a seal with the second piece. The interface includes a first groove located that accommodates a first gasket, sets of matching threads on the first and second pieces. The interface section further accommodates a second gasket. In this multi-piece high-voltage insulator, the first material can have a first set of flexural, heat resistance, and electrical standoff characteristics suitable for a first environment, and the second material can have a second set of flexural, heat resistance and electrical standoff characteristics suitable for a second environment.

Podpaly, Yuri Anatoly↗

High-voltage insulators having multiple materials

High-voltage insulators are disclosed that are capable of handling diverse requirements, such as providing high standoff voltages, high temperature cycling, and the ability to withstand flexural stress. One high-voltage insulator includes a first piece formed from a first material, a second piece formed from a second material, and an interface section where the first piece contacts with and forms a seal with the second piece. The interface includes a first groove located that accommodates a first gasket, sets of matching threads on the first and second pieces. The interface section further accommodates a second gasket. In this multi-piece high-voltage insulator, the first material can have a first set of flexural, heat resistance, and electrical standoff characteristics suitable for a first environment, and the second material can have a second set of flexural, heat resistance and electrical standoff characteristics suitable for a second environment.

Podpaly, Yuri Anatoly↗

Informing solar blind radioluminescence imaging through a calibrated spectrum

While direct radiation detection methods offer great insight into the origin of ionizing particles and photons, their use to locate contaminated areas or concealed radioactive sources can lead to undue exposure of personnel and equipment to ionizing radiation or the potential for contamination. These same sources induce ultraviolet (UV) optical photon fluorescence in air – a process referred to as radioluminescence – that may be imaged from low dose regions over larger attenuation lengths than ionizing radiation. However, most optical detection methods are limited to low lighting conditions to image the more abundant ultraviolet-A (UV-A) photons. To extend this capability to room light or daytime conditions, the solar blind region (Ultraviolet-C (UV-C), <280 nm) can be tapped. Though the emission yield of UV-C photons is roughly two orders of magnitude lower than that in the UV-A regime, the UV-C offers dramatic improvements in signal-to-noise ratios under bright lighting conditions due to decreased background interferences. The yield of specific UV-C lines, if present in the literature at all, varies widely, which has a large impact in modeling and analyzing standoff UV-C measurement scenarios. Thus, we have captured improved radioluminescence spectra over 250–400 nm and identified observed emission peaks in ambient air. Many of the UV-C photons produced by ionizing radiation excitation result from high-energy, molecular nitrogen Gaydon-Herman transitions which have had limited study to date for this application. Relating these findings to published UV-A yields, we estimate emissions between 0.15–0.19 photons/MeV over 250–280 nm. Additionally, we also use a commercial corona-discharge imaging camera to demonstrate outdoor UV-C radiation mapping of alpha and gamma emitters from 50 and 75 m standoffs, respectively. The imaged “counts” are compared to optically modelled values and show the same trend over distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗