Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spray cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Si ribbon crystal for the solar battery using the horizontal pull method

A method utilizing a device to spray noble gases to cool the site of silicon crystal growth is described. The salient points are: (1) soft and uniform cooling was possible, (2) the length of the boundary surface of growth along the growth direction was made long over a wide width compared to the thickness, and (3) this made it possible to effectively remove the heat produced from solification. By using forced gas spraying on the solution surface in contact with the points of crystal growth, growth at the points of growth is enhanced and the rate of growth is speeded up.

Norifuji, H.↗

Plasma sprayed ceramic thermal barrier coatings for turbine vane platforms

The paper describes the results to date of an investigation of advanced plasma sprayed ceramic coatings to demonstrate cooling concepts applicable for turbine vane platforms. It is noted that the increased resistance of plasma sprayed ceramic coatings to cyclic thermal exposure can be achieved by increasing the strain tolerance of the ceramic and by controlling harmful residual stresses. Strain tolerance can be increased by controlling internal structure to minimize harmful flaws and to add favorable discontinuities.

Ruckle, D. L.↗

High Performance Thermal Switch for Lunar and Planetary Surface Extreme Environments

This paper describes a high performance thermal switch for lunar/planetary extreme environments. This device has been given the name Reverse-Operation DTE Thermal Switch (or ROD-TSW). Two different prototypes were designed, built, and tested. Their basis of operation is the mating/de-mating of parallel flat metal surfaces driven by the differential thermal expansion (DTE) between mid-to-high CTE metal/polymer or metal-only end-pieces and a low CTE, low thermal conductivity (k) metal/polymer support rod. The requirements were to be fully ON above 300 K and fully OFF below 260 K. A series of four tests were carried out to verify/qualify the prototypes. In the first (non-vacuum) test, the thermal switches were cooled with freeze-spray and the non-conductive rod in the OFF thermal path allowed electrical resistance to confirm the 273 K as-designed ON/OFF actuation temperature. In the second (vacuum) test, a calibrated Q-meter was used, which indicated 5 W/K ON, 0.002 W/K OFF conductance (2500:1 ON/OFF ratio). To increase readiness to TRL6, a vibration test with pre/post thermal cycling followed by a 36-day test in a relevant environment were also carried out. This paper describes the development program and on-going related work at JPL.

Bugby, David C↗

High Performance Thermal Switch for Lunar and Planetary Surface Extreme Environments

This paper describes a high performance thermal switch for lunar/planetary extreme environments. This device has been given the name Reverse-Operation DTE Thermal Switch (or ROD-TSW). Two different prototypes were designed, built, and tested. Their basis of operation is the mating/de-mating of parallel flat metal surfaces driven by the differential thermal expansion (DTE) between mid-to-high CTE metal/polymer or metal-only end-pieces and a low CTE, low thermal conductivity (k) metal/polymer support rod. The requirements were to be fully ON above 300 K and fully OFF below 260 K. A series of four tests were carried out to verify/qualify the prototypes. In the first (non-vacuum) test, the thermal switches were cooled with freeze-spray and the non-conductive rod in the OFF thermal path allowed electrical resistance to confirm the 273 K as-designed ON/OFF actuation temperature. In the second (vacuum) test, a calibrated Q-meter was used, which indicated 5 W/K ON, 0.002 W/K OFF conductance (2500:1 ON/OFF ratio). To increase readiness to TRL6, a vibration test with pre/post thermal cycling followed by a 36-day test in a relevant environment were also carried out. This paper describes the development program and on-going related work at JPL.

Bugby, David C.↗

Passively Cooled Superconductors Final Report

A highly reflective spray-on coating and tile material has been under development at Kennedy Space Center (KSC) that scatters away most of the Sun’s energy, thereby allowing coated objects to remain cool in space. The best performing tile material has achieved 1% solar absorptivity while the best performing spray-on coating has achieved around 4%. Both versions passively maintain cryogenic temperatures below 120 K at 1 astronomical unit (AU) from the Sun, but the tile material consistently sustains temperatures below 90 K, which is low enough to preserve oxygen and methane in a liquid state. Besides keeping propellants cold, this “solar white” material has the potential to passively maintain high-temperature superconductors (HTS) in a superconducting state without the support of liquid nitrogen cooling. If superconductors can be operated without the added infrastructure of liquid nitrogen cooling, it may enable them to be used in space for applications like magnetic radiation shielding and efficient energy management. Long duration exposure to both galactic cosmic radiation and coronal mass ejections can pose health risks for the astronauts and increase the potential for damage to electronics. This makes shielding essential to accomplish long duration missions, particularly when astronauts are onboard. The objective of this project was to determine the extent we could keep a high-temperature superconducting (HTS) material passively chilled to maintain its superconducting state. Both the tile and spray-on versions of solar white were investigated. We focused on finding a version that could support passive cooling at 1 AU from the Sun and determined the closest operating distances for samples that were unable to perform at 1 AU. Early in the project, we selected bismuth strontium calcium copper oxide (BSCCO) as the HTS to test based on its reputable usage in superconducting wires. The version we selected was Bi-2223, which has a critical temperature of about 108 K. Sample bars with contacts for a four-point probe were obtained from Quantum Levitation: https://quantumlevitation.com/product/superconductor-bar-for-4-point-tc-experiment/.

superconductors↗

Optimal Substrate Preheating Model for Thermal Spray Deposition of Thermosets onto Polymer Matrix Composites

High velocity oxy-fuel (HVOF) sprayed, functionally graded polyimide/WC-Co composite coatings on polymer matrix composites (PMC's) are being investigated for applications in turbine engine technologies. This requires that the polyimide, used as the matrix material, be fully crosslinked during deposition in order to maximize its engineering properties. The rapid heating and cooling nature of the HVOF spray process and the high heat flux through the coating into the substrate typically do not allow sufficient time at temperature for curing of the thermoset. It was hypothesized that external substrate preheating might enhance the deposition behavior and curing reaction during the thermal spraying of polyimide thermosets. A simple analytical process model for the deposition of thermosetting polyimide onto polymer matrix composites by HVOF thermal spray technology has been developed. The model incorporates various heat transfer mechanisms and enables surface temperature profiles of the coating to be simulated, primarily as a function of substrate preheating temperature. Four cases were modeled: (i) no substrate preheating; (ii) substrates electrically preheated from the rear; (iii) substrates preheated by hot air from the front face; and (iv) substrates electrically preheated from the rear and by hot air from the front.

Ivosevic, M.↗

A Cooling System for the EAPU Shuttle Upgrade

The Shuttle orbiter currently uses hydrazine-powered APU's for powering its hydraulic system pumps. To enhance vehicle safety and reliability, NASA is pursuing an APU upgrade where the hydrazine powered turbine is replaced by an electric motor pump and battery power supply. This EAPU (Electric APU) upgrade presents several thermal control challenges most notably the new requirement for moderate temperature control of high-power electron ics at 132 of (55.6 C). This paper describes how the existing Water Spray Boiler (WSB), which currently cools the hydraulic fluid and APU lubrication oil, is being modified to provide EAPU thermal management.

Tongue, Stephen↗

Coating Development for GRCop-84 Liners for Reusable Launch Vehicles Aided by Modeling Studies

The design of the next generation of reusable launch vehicles calls for using GRCop-84 copper alloy liners based on a composition invented at the NASA Glenn Research Center. Despite its considerable advantage over other copper alloys, it is expected that GRCop-84 will suffer from environmental degradation depending on the type of rocket fuels used and on thermomechanical fatigue. Applying protective coatings on GRCop-84 substrates can minimize or eliminate many of these problems and extend the operational life of the combustion liner. This could increase component reliability, shorten depot maintenance turnaround times, and lower operating costs. Therefore, Glenn is actively pursuing the development of advanced coatings technology for GRCop-84 liners. Technology is being developed in four major areas: (1) new metallic coating compositions, (2) application techniques, (3) test methods, and (4) life prediction design methodology using finite element analysis. The role of finite element analysis in guiding the coating effort is discussed in this report. Thermal analyses were performed at Glenn for different combinations of top- and bondcoat compositions to determine the temperature variation across the coated cross section with the thickness of the top coat. These calculations were conducted for simulated LH2/LO2 booster engine conditions assuming that the bond coat had a constant thickness of 50 m. The preceding graphs show the predicted temperatures at the outer surface of the top coat (hot wall), at the top-coat/bond-coat interface, at the bond-coat/GRCop-84 interface, and at the GRCop-84 cold wall as a function of top-coat thickness for Cu- 26(wt%)Cr top coat (top graph), Ni-17(wt%)Cr-6%Al-0.5%Y top coat and Cu-26%Cr bond coat, and NiAl top coat and Ni bond coat. In all cases, the temperature of the top coat at the hot wall increased with increasing top-coat thickness and with corresponding decreases in the temperatures at the two interfaces and the cold wall. These temperatures are not acutely sensitive to the thermal conductivity of the top coat when it exceeds 25 and 50 W/m/K for low and high heat flux engines. This observation is significant for two reasons. First, several different top-coat compositions can be evaluated as potential protective coatings without loss in the heat-transfer efficiency of the coated system. Second, materials with thermal conductivities less than the critical values of 25 or 50 W/m/K are more likely to act as thermal barrier coatings. The deposition of overlay coatings on GRCop-84 substrates results in the development of residual stresses. The presence of these residual stresses influences the probability of coating spallation, the thermal cycling life, and the fatigue properties of the coated substrate during use. Since it is important to understand how these stresses develop during the vacuum-plasma-spraying coating deposition process, the nature and magnitudes of the cool-down residual stresses were calculated and compared with experimentally determined values across the coated cross section of a disk specimen. The calculations were conducted assuming that the specimen cools down to room temperature from vacuum plasma-spraying temperatures of either 250 or 650 C. The effects of coating the substrate with and without grit blasting were also theoretically examined. The final graph compares the predicted and the experimental results for a GRCop-84 disk coated with about a 50- m-thick Ni bond coat and a 75- to 100- m NiAl top coat, where the curves for NASA-2 assume the presence of a prior residual stress generated by grit blasting under conditions similar to the experimental situation. The predicted cool-down in-plane stresses were compressive in both the NiAl top coat and the Ni bond coat. They were also compressive in the substrate to a depth of about 0.25 mm from the Ni/GRCop-84 interface when the vacuum-plasma-spraying temperature was low. However, using a higher plasma spraying temperaturs likely to leave the substrate under a small tensile stress to counter the compressive stresses in the bond and top coats because of the relaxation of residual stresses generated in the substrate during the grit blasting of its surface prior to spraying. These results suggest that the NiAl and Ni coatings are unlikely to spall after spraying as confirmed by the microstructural observations shown in the following photomicrograph of an as-sprayed specimen. Finally, it is noted that the calculated and experimental results are not in complete agreement, which indicates that both the experimental and modeling techniques need further refinement.

Raj, Sai V.↗

An Assessment of the Residual Stresses in Low Pressure Plasma Sprayed Coatings on an Advanced Copper Alloy

Modeling studies were conducted on low pressure plasma sprayed (LPPS) NiAl top coat applied to an advanced Cu-8(at.%)Cr-4%Nb alloy (GRCop-84) substrate using Ni as a bond coat. A thermal analysis suggested that the NiAl and Ni top and bond coats, respectively, would provide adequate thermal protection to the GRCop-84 substrate in a rocket engine operating under high heat flux conditions. Residual stress measurements were conducted at different depths from the free surface on coated and uncoated GRCop-84 specimens by x-ray diffraction. These data are compared with theoretically estimated values assessed by a finite element analysis simulating the development of these stresses as the coated substrate cools down from the plasma spraying temperature to room temperature.

Raj, S. V.↗

Ceramic thermal-barrier coatings for cooled turbines

Coating systems consisting of a plasma sprayed layer of zirconia stabilized with either yttria, magnesia or calcia over a thin alloy bond coat have been developed, their potential was analyzed and their durability and benefits evaluated in a turbojet engine. The coatings on air cooled rotating blades were in good condition after completing as many as 500 two-minute cycles of engine operation between full power at a gas temperature of 1644 K and flameout, or as much as 150 hours of steady state operation on cooled vanes and blades at gas temperatures as high as 1644 K with 35 start and stop cycles. On the basis of durability and processing cost, the yttria stabilized zirconia was considered the best of the three coatings investigated.

Liebert, C. H.↗

The cryogenic wind tunnel for high Reynolds number testing

Experiments performed at the NASA Langley Research Center in a cryogenic low-speed continuous-flow tunnel and in a cryogenic transonic continuous-flow pressure tunnel have demonstrated the predicted changes in Reynolds number, drive power, and fan speed with temperature, while operating with nitrogen as the test gas. The experiments have also demonstrated that cooling to cryogenic temperatures by spraying liquid nitrogen directly into the tunnel circuit is practical and that tunnel temperature can be controlled within very close limits. Whereas most types of wind tunnel could operate with advantage at cryogenic temperatures, the continuous-flow fan-driven tunnel is particularly well suited to take full advantage of operating at these temperatures. A continuous-flow fan-driven cryogenic tunnel to satisfy current requirements for test Reynolds number can be constructed and operated using existing techniques. Both capital and operating costs appear acceptable.

Kilgore, R. A.↗

Reliability and effective thermal conductivity of three metallic-ceramic composite insulating coatings on cooled hydrogen-oxygen rockets

An experimental investigation of the structural integrity and effective thermal conductivity of three metallic-ceramic composite coatings was conducted. These coatings were plasma sprayed onto the combustion side of water-cooled, 12.7-centimeter throat diameter, hydrogen-oxygen rocket thrust chambers operating at 2.07 to 4.14 meganewtons per square meter chamber pressure. The metallic-ceramic composites functioned for six to 17 cycles and for as long as 213 seconds of rocket operations and could have probably provided their insulating properties for many additional cycles. The effective thermal conductivity of all the coatings was in the range of 0.7472 to 4.483 w/(m)(K), which makes the coatings a very effective thermal barrier. Photomicrographic studies of cross-sectioned coolant tubes seem to indicate that the effective thermal conductivity of the coatings is controlled by contact resistance between the particles, as a result of the spraying process, and not the thermal conductivity of the bulk materials.

Price, H. G., Jr.↗

Passive Rocket Diffuser Testing: Reacting Flow Performance of Four Second-Throat Geometries

Second-throat diffusers serve to isolate rocket engines from the effects of ambient back pressure. As one of the nation's largest rocket testing facilities, the performance and design limitations of diffusers are of great interest to NASA's Stennis Space Center. This paper describes a series of tests conducted on four diffuser configurations to better understand the effects of inlet geometry and throat area on starting behavior and boundary layer separation. The diffusers were tested for a duration of five seconds with a 1455-pound thrust, LO2/GH2 thruster to ensure they each reached aerodynamic steady state. The effects of a water spray ring at the diffuser exits and a water-cooled deflector plate were also evaluated. Static pressure and temperature measurements were taken at multiple axial locations along the diffusers, and Computational Fluid Dynamics (CFD) simulations were used as a tool to aid in the interpretation of data. The hot combustion products were confirmed to enable the diffuser start condition with tighter second throats than predicted by historical cold-flow data or the theoretical normal shock method. Both aerodynamic performance and heat transfer were found to increase with smaller diffuser throats. Spray ring and deflector cooling water had negligible impacts on diffuser boundary layer separation. CFD was found to accurately capture diffuser shock structures and full-flowing diffuser wall pressures, and the qualitative behavior of heat transfer. However, the ability to predict boundary layer separated flows was not consistent.

Jones, Daniel R.↗

Study of lubricant jet flow phenomena in spur gears: Out of mesh condition

The penetration depth onto the tooth flank of a jet of oil at different velocities pointed at the pitch line on the outgoing side of mesh was determined. The analysis determines the impingement depth for both the gear and the pinion. It includes the cases for speed increasers and decreasers as well as for one to one gear ratio. In some cases the jet will strike the loaded side of the teeth, and in others it will strike the unloaded side of the teeth. In nearly all cases the top land will be cooled regardless of the penetration depth, and postimpingement oil spray will usually provide adequate amounts of oil for lubrication but is marginal or inadequate for cooling.

Townsend, D. P.↗

Independent Orbiter Assessment (IOA): Analysis of the hydraulics/water spray boiler subsystem

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items (PCIs). To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results for the Orbiter Hydraulics/Water Spray Boiler Subsystem. The hydraulic system provides hydraulic power to gimbal the main engines, actuate the main engine propellant control valves, move the aerodynamic flight control surfaces, lower the landing gear, apply wheel brakes, steer the nosewheel, and dampen the external tank (ET) separation. Each hydraulic system has an associated water spray boiler which is used to cool the hydraulic fluid and APU lubricating oil. The IOA analysis process utilized available HYD/WSB hardware drawings, schematics and documents for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 430 failure modes analyzed, 166 were determined to be PCIs.

Duval, J. D.↗

Analysis of Supercooled Large Drop Velocity Measurement in the NASA Icing Research Tunnel

An experiment was conducted in the Icing Research Tunnel (IRT) at the NASA Glenn Research Center to measure the velocity of supercooled large drops (SLD) in the test section of the tunnel. Previous experiments in the IRT suggested that supercooled large drops passing through the test section of the tunnel do not move at the same velocity as the surrounding air flow. The difference between drop velocity and tunnel air velocity is called slip velocity. The slip velocity is important for determining the exact nature of SLD icing simulation in the IRT. It can impact the ice growth process because of its effect on drop cooling rate during transit from the spray bars to the test section. It can also affect the amount of splashing that occurs upon impact. Slip velocity is an important flow parameter to determine how far the current facility capabilities can be extended into the SLD regime. Initial measurement data analysis of the drop velocities indicates that drops with diameter larger than about 100 to 200 µm experience velocity slip.

SLD↗

Oil-air mist lubrication for helicopter gearing

The applicability of a once-through oil mist system to the lubrication of helicopter spur gears was investigated and compared to conventional jet spray lubrication. In the mist lubrication mode, cooling air was supplied at 366K (200 F) to the out of mesh location of the gear sets. The mist air was also supplied at 366K (200 F) to the radial position mist nozzle at a constant rate of 0.0632 mol/s (3 SCFM) per nozzle. The lubricant contained in the mist air varied between 32 - 44 cc/hour. In the recirculating jet spray mode, the flow rate was varied between 1893 - 2650 cc/hour. Visual inspection revealed the jet spray mode produced a superior surface finish on the gear teeth but a thermal energy survey showed a 15 - 20% increase in heat generated. The gear tooth condition in the mist lubrication mode system could be improved if the cooling air and lubricant/air flow ratio were increased. The test gearbox and the procedure used are described.

Mcgrogan, F.↗