Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spray cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effects of Plume Targeted Cooling on Residual Stress in Controlled Atmosphere Plasma Sprayed Coatings

Thermal spray processes can benefit from cooling to maintain substrate temper, reduce processing times, and manage thermally induced residual stresses. “Plume quenching” is a plume-targeted cooling technique which has been shown to reduce substrate temperatures by redirection of hot plume gases using a lateral argon curtain injected into the plume, while limiting interaction with the substrate or affecting coating properties. Here, this study explores the use of this technique for residual stress management by reducing the thermally driven component in nickel and tantalum coatings on titanium and aluminum substrates. The in-situ residual stress profiles were measured for all substrate and coating pairings during spraying and cooling, and the deposition and thermal stresses recorded. For substrate and coating pairings where the predominant component of residual stress was thermal (driven by a large difference in coefficient of thermal expansion, Δα, between coating and substrate), plume quenching reduced both the thermal stress and the final stress state of the coating. This was seen primarily in tantalum on aluminum coatings where the Δα was -17 × 10 -6 /°C, and thermal stress was reduced by 7.5% and 22.4% for the plume quenching rates of 50 and 100 slpm, respectively.

42 ENGINEERING↗

Evaporative cooling on a grooved surface

The transition point where water begins to accumulate on the surface during spray evaporative cooling was investigated experimentally to determine the temperatures and corresponding heat flux at which this transition occurs. Several pressure ranges were considered including one below the triple point of water. Additionally, the results using a grooved surface were compared to those using a smooth surface. It was determined that a grooved surface has no effect on the heat transfer.

Yoder, D.↗

An Apollo compatible cloud physics experiment.

Consideration of the utilization of a low-gravity environment to obtain experimental information, in the area of cloud microphysics, which cannot be obtained in ground laboratories. The experiment discussed is designed to obtain quantitative answers about evaporation and breakup of salt particles from ocean spray and other sources. In addition to salt nuclei distribution mechanisms, this breakup has ecological importance in relation to the spreading of salt mists from salted highways and spreading of brine cooling tower spray from electrical power generation plants. This experiment is being submitted for consideration on the Apollo-Soyuz Test Program in 1975.

Eaton, L. R.↗

A fundamental study of liquid spray evaporation at a heated surface

The influence of feedwater temperature and the influence of pulsing nozzle flow on the heat transfer characteristics in the spray evaporative cooling process were investigated. A commercial water circulation heater was installed in the feedwater line between the supply reservoir and the nozzle. A pass through the heater provided water at temperatures up to 50 C at the nozzle; higher temperatures were obtained by multiple heater passes. A thermocouple installed in the water line just upstream of the nozzle provided a measure of the feedwater temperature. Initial tests were run with belljar exhaust orifice number two which provided a pressure in a range about 7mm Hg abs. The feedwater temperature was heated to a temperature of 45 C. Results indicate that for a given system operating pressure, there is an upper limit on the feedwater temperature above which the spray will flash to vapor before hitting the surface to be cooled.

Wierum, F. A.↗

Vacuum Plasma Spray Forming of Copper Alloy Liners for Regeneratively Cooled Liquid Rocket Combustion Chambers

Vacuum plasma spray (VPS) has been demonstrated as a method to form combustion chambers from copper alloys NARloy-Z and GRCop-84. Vacuum plasma spray forming is of particular interest in the forming of CuCrNb alloys such as GRCop-84, developed by NASA s Glenn Research Center, because the alloy cannot be formed using conventional casting and forging methods. This limitation is related to the levels of chromium and niobium in the alloy, which exceed the solubility limit in copper. Until recently, the only forming process that maintained the required microstructure of CrNb intermetallics was powder metallurgy formation of a billet from powder stock, followed by extrusion. This severely limits its usefulness in structural applications, particularly the complex shapes required for combustion chamber liners. This paper discusses the techniques used to form combustion chambers from CuCrNb and NARloy-Z, which will be used in regeneratively cooled liquid rocket combustion chambers.

Zimmerman, Frank↗

, Experimental Investigation of Electrically Charged Water Droplets Two-Phase Cross-Flow Interactions with Humid

Electrically charged water droplets can capture water vapor molecules in surrounding moist air and promote vapor condensation. This concept unfolds an alternative to mechanical cooling-based air dehumidification systems that separate sensible and latent cooling loads in HVAC applications. The effect of dielectrophoresis, electro-hydrodynamic, and micro-diffusive flows due to highly electrically charged water droplets traveling through moist air were investigated as new methods to reduce the air’s water vapor content. This paper presents new experimental data on humidification and power consumption for a system consisting of highly energized electrosprays in combination with mist eliminators. Electrosprays produced highly charged water spray cones crossing the air perpendicularly and upwardly. The moist air stream was circulated in a horizontal duct at 22C, 80% relative humidity, and 0.24 ms-1 airspeed. Mist eliminators made of stainless wire clothes of 36 and 25 μm pore diameter were used to screen the droplets growing during their flight trajectory. The mist eliminators blocked some of the largest diameter droplets. Still, they could not prevent re-evaporation of the droplets into the bulk air from the droplets deposited on their wire clothes. The equilibrium between the dielectrophoresis condensation from the electrosprays and the droplets’ re-evaporation phenomena resulted in reduced humidification when compared to conventional-type spray evaporative cooling systems. However, to dehumidify the air, the droplets injected by the electrosprays must be separated entirely and promptly removed from the bulk airflow at the end of their flight trajectory.

Electrostatic droplets, Electrospray, humidificati↗

Modeling Self-Pressurization and Spray Bar Pressure Control of a Cryogenic Storage Tank in Normal Gravity

This paper presents Computational Fluid Dynamics (CFD) models for simulating self-pressurization and spray bar cooling processes in a large-scale liquid hydrogen storage tank under normal gravity. The self-pressurization model utilizes the kinetics-based Schrage equation with the Volume-Of-Fluid (VOF) model to account for the evaporative and condensing interfacial mass fluxes. It uses a laminar approach to model natural convection and compares the pressures and temperatures predicted by the CFD model with experimental data from the Multipurpose Hydrogen Test Bed (MHTB) self-pressurization experiment. Additionally, the predicted interfacial mass flux is presented. A CFD model for simulating pressure control using a spray bar is also presented. An Eulerian-Lagrangian approach models the interactions between the discrete droplets and the continuous ullage phase. The spray model is coupled with the VOF model by tracking particles in the ullage, removing particles from the ullage when they reach the interface, and then adding their contributions to the liquid. The T-sat model is used to calculate the droplet-ullage heat and mass transfer. In this model, droplets warm up to the saturation temperature corresponding to the ullage vapor pressure thereafter evaporating while remaining at the saturation temperature. The tank pressure, vapor, and liquid temperature evolutions are validated against data from the MHTB spray bar mixing experiment.

Self-Pressurization↗

CFD Modeling of the Multipurpose Hydrogen Test Bed (MHTB) Self-Pressurization and Spray Bar Mixing Experiments in Normal Gravity: Effect of Accommodation Coefficient on the Tank Pressure

In this paper, a computational model that describes pressure control phase of a typical MHTB experiment will be presented. The fidelity of the model will be assessed by comparing the models predictions with MHTB experimental data. In this paper CFD results for MHTB spray bar cooling case with 50 tank fill ratio will be presented and analyzed. Effect of accommodation coefficient for calculating droplet-ullage mass transfer will be evaluated.

cryogenic fluid storage↗

The role of cool-flame fluctuations in high-pressure spray flames, studied using high-speed optical diagnostics and Large-Eddy Simulations

Here this work investigates the low- and high-temperature ignition and combustion processes, applied to the Engine Combustion Network Spray A flame, combining advanced optical diagnostics and large-eddy simulations (LES). Simultaneous high-speed (50 kHz) formaldehyde (CH 2 0) planar laser-induced fluorescence (PLIF) and line-of-sight OH* chemiluminescence imaging were used to measure the low- and high-temperature flame, during ignition as well as during quasi-steady combustion. While tracking the cool flame at the laser sheet plane, the present experimental setup allows detection of distinct ignition spots and dynamic fluctuations of the lift-off length over time, which overcomes limitations for flame tracking when using schlieren imaging. After significant development to improve LES prediction of the low-and high-temperature flame position, both during the ignition processes and quasi-steady combustion, the simulations were analyzed to gain understanding of the mixture variance and how this variance affects formation/consumption of CH 2 0. Analysis of the high-temperature ignition period shows that a key improvement in the LES is the ability to predict heterogeneous ignition sites, not only in the head of the jet, but in shear layers at the jet edge close to the position where flame lift-off eventually stabilizes. The LES analysis also shows concentrated pockets of CH 2 0, in the center of jet and at 20 mm downstream of the injector (in regions where the equivalence ratio is greater than 6), that are of similar length scale and frequency as the experiment (approximately 5–6 kHz). The periodic oscillation of CH 2 0 match the frequency of pressure waves generated during auto-ignition and reflected within the constant-volume vessel throughout injection. The ability of LES to capture the periodic appearance and destruction of CH 2 0 is particularly important because these structures travel downstream and become rich premixed flames that affect soot production.

42 ENGINEERING↗

Liquid-cooling technology for gas turbines - Review and status

After a brief review of past efforts involving the forced-convection cooling of gas turbines, the paper surveys the state of the art of the liquid cooling of gas turbines. Emphasis is placed on thermosyphon methods of cooling, including those utilizing closed, open, and closed-loop thermosyphons; other methods, including sweat, spray and stator cooling, are also discussed. The more significant research efforts, design data, correlations, and analytical methods are mentioned and voids in technology are summarized.

Van Fossen, G. J., Jr.↗

Experimental Studies of Spray Deposition on a Flat Surface in a Vacuum Environment

Cooling of spacecraft components in the space environment is an on-going research effort. The electronics used in modern spacecraft are always changing and the heat flux is increasing. New, one-of-a-kind missions require new approaches to thermal control. In this research, under vacuum conditions, a pulsed water spray impinged on a small disc, while a high speed data acquisition system recorded the temperature histories of this copper disc. The water droplets froze quickly and accumulated on the disc as the spray continued. After the spray stopped, the frozen water that remained on the disc then sublimated into the vacuum environment and cooled the disc. This paper examines two important aspects of this process: 1) the difference in spray start up and shutdown in a vacuum environment versus in a standard atmospheric pressure environment, and 2) the water utilization efficiency in a vacuum environment due to the effects of drop trajectories and drop bouncing on the surface. Both phenomena play a role during spray cooling in a vacuum. This knowledge should help spacecraft designers plan for spray cooling as an option to cool spacecraft electronics, human metabolic generated heat, and heat from other sources.

Spray Cooling↗

Feasibility of Conducting J-2X Engine Testing at the Glenn Research Center Plum Brook Station B-2 Facility

A trade study of the feasibility of conducting J-2X testing in the Glenn Research Center (GRC) Plum Brook Station (PBS) B-2 facility was initiated in May 2006 with results available in October 2006. The Propulsion Test Integration Group (PTIG) led the study with support from Marshall Space Flight Center (MSFC) and Jacobs Sverdrup Engineering. The primary focus of the trade study was on facility design concepts and their capability to satisfy the J-2X altitude simulation test requirements. The propulsion systems tested in the B-2 facility were in the 30,000-pound (30K) thrust class. The J-2X thrust is approximately 10 times larger. Therefore, concepts significantly different from the current configuration are necessary for the diffuser, spray chamber subsystems, and cooling water. Steam exhaust condensation in the spray chamber is judged to be the key risk consideration relative to acceptable spray chamber pressure. Further assessment via computational fluid dynamics (CFD) and other simulation capabilities (e.g. methodology for anchoring predictions with actual test data and subscale testing to support investigation.

Schafer, Charles F.↗

High-Emissivity Coatings For High-Temperature Surfaces

Plasma-sprayed coatings increase cooling by thermal radiation. Coating of zirconium diboride on tungsten or molybdenum increases emissivity of surface to more than 0.6 at 2,000 degree C. Applied by plasma-arc spraying after surface cleaned and roughened to ensure adhesion.

Deininger, William D.↗

Fouling mechanism in airblast atomizers and its suppression for water desalination

A detailed experimental study is presented on fouling behavior of the anti-clogging perforated plate atomizer designed for high salinity applications, and compared with a conventional (plain-jet) airblast atomizer. Low-pressure regions around fast moving air in the outer layer of spray (as in conventional atomizers: plain-jet and prefilming) due to Venturi suction were identified as the root cause of atomizer clogging, as they facilitate salt accumulation on the atomizer surface from spray. Accordingly, severe atomizer fouling, and fluctuations in spray cone angle were observed in the conventional airblast atomizer over 2 h at 100°C air and 50°C saline (44° to 76° at 35,000 ppm, and 44° to 91° at 100,000 ppm). In this regard, the perforated plate atomizer provides a novel liquid-film airblast atomization by maintaining a liquid-annulus film (around the air outlet) as the outer layer of spray. Doing so we achieved nearly complete suppression of fouling, and spray cone angle fluctuations (28° ± 1° at 35,000 ppm, and 30° ± 1° at 100,000 ppm). Later, novel liquid-film atomization was adopted in the conventional airblast atomizer. While, the conventional airblast atomization needed atomizer cleaning/maintenance after 35 min for 175°C air and 65°C saline at 100,000 ppm, the liquid-film atomization showed no sign of fouling over 14 h. Hence, current work establishes a benchmark liquid-film airblast atomization mechanism in the anti-clogging perforated plate atomizer for complete suppression of fouling in airblast atomization. Furthermore, this extends the application of airblast atomizers from high evaporation jet engines to ZLD-HDH desalination systems, spraying, powder metallurgy, pharmaceuticals and hospitals, and spray drying and cooling.

42 ENGINEERING↗

Thermocapillary Convection in Liquid Droplets

The purpose of this video is to understand the effects of surface tension on fluid convection. The fluid system chosen is the liquid sessile droplet to show the importance in single crystal growth, the spray drying and cooling of metal, and the advance droplet radiators of the space stations radiators. A cross sectional representation of a hemispherical liquid droplet under ideal conditions is used to show internal fluid motion. A direct simulation of buoyancy-dominant convection and surface tension-dominant convection is graphically displayed. The clear differences between two mechanisms of fluid transport, thermocapillary convection, and bouncy dominant convection is illustrated.

Source record↗