Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Gamma Source Verification for GAMSRC and GAMSOR

Nuclear reactors that rely upon the fission reaction have two modes of thermal energy deposition in the reactor system: neutron absorption and gamma absorption. The gamma rays are typically generated by neutron capture reactions or during the fission process which means the primary driver of energy production is of course the neutron interactions. The GAMSOR program was first built in the mid 1980s to properly account for the gamma heating in an operating reactor core on core internals. The GAMSOR code is sequence of DIF3D calculations to compute the neutron and gamma flux and combine them to define both the neutron and gamma heating throughout the modeled domain. The goal of this manuscript is to present the software verification of GAMSOR. The first step of the GAMSOR sequence of calculations involves of a modified version of DIF3D (called DIF3D-GAMSOR) which generates a gamma source distribution for the follow-on DIF3D gamma transport calculation (step 2). This modified version of DIF3D increases the burden of maintenance and verification work on GAMSOR as one must reverify the DIF3D capabilities which is undesirable. Because the calculation of the gamma source is the only unique aspect of GAMSOR beyond the regular DIF3D capabilities, that part was put in a standalone code called GAMSRC such that one can use the verified DIF3D code in step 1 followed by GAMSRC to carry out the same GAMSOR calculation step. As a consequence, this manuscript is focused on verification of the gamma source files generated by GAMSRC. The verification of the modified version of DIF3D (DIF3D-GAMSOR) will be done less rigorously in that it will be verified that it produces the same output that GAMSRC does and thus GAMSRC is equivalent to GAMSOR on the problems studied here. Hand calculations and independent numerical calculations of the gamma source generation are used for the verification work. This work follows the same methodology of GAMSRC. As expected, the results agree well with those calculated by GAMSRC as will be shown.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification of EvaluateFLux Utility Program

The EvaluateFlux program is a post-processing utility program for DIF3D, specifically DIF3D-VARIANT which handles Cartesian and hexagonal geometries. The EvaluateFlux program was developed to allow users to obtain flux and power traverses through the geometry domain, and its initial purpose was to facilitate foil analysis by evaluating the flux solution from DIF3D-VARIANT and combining it with foil cross section data. The EvaluateFlux program can calculate the neutron flux, as well as the reaction rates, at any user provided evaluation point. It does this by identifying the spatial mesh associated with the evaluation point and then evaluates the polynomial based neutron flux moments stored in the NHFLUX file at that point. The output of EvaluateFlux varies depending on the input setup. The maximum output includes the neutron flux and microscopic and macroscopic reaction rates at each evaluation point. The purpose of this work is to verify the outputs of EvaluateFlux. Simple models that have hand calculatable results are first defined and used to verify the EvaluateFlux outputs. More complex cases are then added where a duplicate program of EvaluateFlux that uses PrintTables outputs of the binary files is used to verify the EvaluateFlux outputs. In those complex cases, hand calculations of selected evaluation points were also displayed to confirm the software verification. For all the tests done, the hand calculations agreed well with those calculated by EvaluateFlux. For the larger complex problems, the duplicate program that can process hundreds of evaluation points was able to identify that zero points within some meshes have large errors. This aspect was attributed to the truncation error on the input provided to the duplicate program and is not a concern for the accuracy of the EvaluateFlux software.

97 MATHEMATICS AND COMPUTING↗

Verification of the EvaluateFlux Utility Program

The EvaluateFlux program is a post-processing utility program for DIF3D, specifically DIF3D-VARIANT which handles Cartesian and hexagonal geometries. The EvaluateFlux program was developed to allow users to obtain flux and power traverses through the geometry domain, and its initial purpose was to facilitate foil analysis by evaluating the flux solution from DIF3D-VARIANT and combining it with foil cross section data. The EvaluateFlux program can calculate the neutron flux, as well as the reaction rates, at any user provided evaluation point. It does this by identifying the spatial mesh associated with the evaluation point and then evaluates the polynomial based neutron flux moments stored in the NHFLUX file at that point. The output of EvaluateFlux varies depending on the input setup. The maximum output includes the neutron flux and microscopic and macroscopic reaction rates at each evaluation point. The purpose of this work is to verify the outputs of EvaluateFlux. Simple models that have hand calculatable results are first defined and used to verify the EvaluateFlux outputs. More complex cases are then added where a duplicate program of EvaluateFlux that uses PrintTables outputs of the binary files is used to verify the EvaluateFlux outputs. In those complex cases, hand calculations of selected evaluation points were also displayed to confirm the software verification. For all the tests done, the hand calculations agreed well with those calculated by EvaluateFlux. For the larger complex problems, the duplicate program that can process hundreds of evaluation points was able to identify that zero points within some meshes have large errors. This aspect was attributed to the truncation error on the input provided to the duplicate program and is not a concern for the accuracy of the EvaluateFlux software.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A new ensemble-based consistency test for the Community Earth System Model (pyCECT v1.0)

Abstract. Climate simulation codes, such as the Community Earth System Model (CESM), are especially complex and continually evolving. Their ongoing state of development requires frequent software verification in the form of quality assurance to both preserve the quality of the code and instill model confidence. To formalize and simplify this previously subjective and computationally expensive aspect of the verification process, we have developed a new tool for evaluating climate consistency. Because an ensemble of simulations allows us to gauge the natural variability of the model's climate, our new tool uses an ensemble approach for consistency testing. In particular, an ensemble of CESM climate runs is created, from which we obtain a statistical distribution that can be used to determine whether a new climate run is statistically distinguishable from the original ensemble. The CESM ensemble consistency test, referred to as CESM-ECT, is objective in nature and accessible to CESM developers and users. The tool has proven its utility in detecting errors in software and hardware environments and providing rapid feedback to model developers.

58 GEOSCIENCES↗

SU-E-T-65: Characterization of a 2D Array for QA and Pretreatment Plan Verification

Purpose: The OCTAVIUS detector729 is a 2D array of 729 air vented cubic plane parallel ion chambers used for pretreatment verification and QA. In this study we investigated dosimetric characteristics of this system for clinical photon beam dosimetry. Methods: Detector performance evaluation included determination of the location of the effective point of measurement (EPM), sensitivity, linearity, and reproducibility of detector response, as well as output factor, dose rate, and source to surface distance (SSD) dependence. Finally, assessment of wedge modulated fields was carried out. All the evaluations were performed five times for low and high photon energies. For reference measurements, a 0.6 cc ionization chamber was used. Data analysis and comparison of the OCTAVIUS detector with reference ion chamber data was performed using the VeriSoft patient plan verification software. Results: The reproducibility and stability of the measurements are excellent, the detector showed same signal with a maximum deviation of less than 0.5% in short and long term. Results of sensitivity test showed same signal with a maximum deviation of approximately 0.1%. As the detector 729 response is linear with dose and dose rate, it can be used for the measurement at regions of high dose gradient effectively. The detector agrees with the ionization chamber measurement to within 1% for SSD range of 75 to 125 cm. Also, its measured wedge modulated profiles matched very well with ion chamber dose profiles acquired in a water tank. Conclusions: As the response of the detector 729 is linear with dose and dose rate, it can be used for the measurements in the areas of dose gradients effectively. Based on the measurements and comparisons performed, this system is a reliable and accurate dosimeter for QA and pretreatment plan verification in radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-762: Toward Volume-Based Independent Dose Verification as Secondary Check

Purpose: Lung SBRT plan has been shifted to volume prescription technique. However, point dose agreement is still verified using independent dose verification at the secondary check. The volume dose verification is more affected by inhomogeneous correction rather than point dose verification currently used as the check. A feasibility study for volume dose verification was conducted in lung SBRT plan. Methods: Six SBRT plans were collected in our institute. Two dose distributions with / without inhomogeneous correction were generated using Adaptive Convolve (AC) in Pinnacle3. Simple MU Analysis (SMU, Triangle Product, Ishikawa, JP) was used as the independent dose verification software program, in which a modified Clarkson-based algorithm was implemented and radiological path length was computed using CT images independently to the treatment planning system. The agreement in point dose and mean dose between the AC with / without the correction and the SMU were assessed. Results: In the point dose evaluation for the center of the GTV, the difference shows the systematic shift (4.5% ± 1.9 %) in comparison of the AC with the inhomogeneous correction, on the other hands, there was good agreement of 0.2 ± 0.9% between the SMU and the AC without the correction. In the volume evaluation, there were significant differences in mean dose for not only PTV (14.2 ± 5.1 %) but also GTV (8.0 ± 5.1 %) compared to the AC with the correction. Without the correction, the SMU showed good agreement for GTV (1.5 ± 0.9%) as well as PTV (0.9% ± 1.0%). Conclusion: The volume evaluation for secondary check may be possible in homogenous region. However, the volume including the inhomogeneous media would make larger discrepancy. Dose calculation algorithm for independent verification needs to be modified to take into account the inhomogeneous correction.

60 APPLIED LIFE SCIENCES↗

SU-F-T-288: Impact of Trajectory Log Files for Clarkson-Based Independent Dose Verification of IMRT and VMAT

Purpose: To investigate the effect of the trajectory files from linear accelerator for Clarkson-based independent dose verification in IMRT and VMAT plans. Methods: A CT-based independent dose verification software (Simple MU Analysis: SMU, Triangle Products, Japan) with a Clarksonbased algorithm was modified to calculate dose using the trajectory log files. Eclipse with the three techniques of step and shoot (SS), sliding window (SW) and Rapid Arc (RA) was used as treatment planning system (TPS). In this study, clinically approved IMRT and VMAT plans for prostate and head and neck (HN) at two institutions were retrospectively analyzed to assess the dose deviation between DICOM-RT plan (PL) and trajectory log file (TJ). An additional analysis was performed to evaluate MLC error detection capability of SMU when the trajectory log files was modified by adding systematic errors (0.2, 0.5, 1.0 mm) and random errors (5, 10, 30 mm) to actual MLC position. Results: The dose deviations for prostate and HN in the two sites were 0.0% and 0.0% in SS, 0.1±0.0%, 0.1±0.1% in SW and 0.6±0.5%, 0.7±0.9% in RA, respectively. The MLC error detection capability shows the plans for HN IMRT were the most sensitive and 0.2 mm of systematic error affected 0.7% dose deviation on average. Effect of the MLC random error did not affect dose error. Conclusion: The use of trajectory log files including actual information of MLC location, gantry angle, etc should be more effective for an independent verification. The tolerance level for the secondary check using the trajectory file may be similar to that of the verification using DICOM-RT plan file. From the view of the resolution of MLC positional error detection, the secondary check could detect the MLC position error corresponding to the treatment sites and techniques. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗

SU-E-T-48: A Multi-Institutional Study of Independent Dose Verification for Conventional, SRS and SBRT

Purpose: To show the results of a multi-institutional study of the independent dose verification for conventional, Stereotactic radiosurgery and body radiotherapy (SRS and SBRT) plans based on the action level of AAPM TG-114. Methods: This study was performed at 12 institutions in Japan. To eliminate the bias of independent dose verification program (Indp), all of the institutions used the same CT-based independent dose verification software (Simple MU Analysis, Triangle Products, JP) with the Clarkson-based algorithm. Eclipse (AAA, PBC), Pinnacle{sup 3} (Adaptive Convolve) and Xio (Superposition) were used as treatment planning system (TPS). The confidence limits (CL, Mean±2SD) for 18 sites (head, breast, lung, pelvis, etc.) were evaluated in comparison in dose between the TPS and the Indp. Results: A retrospective analysis of 6352 treatment fields was conducted. The CLs for conventional, SRS and SBRT were 1.0±3.7 %, 2.0±2.5 % and 6.2±4.4 %, respectively. In conventional plans, most of the sites showed within 5 % of TG-114 action level. However, there were the systematic difference (4.0±4.0 % and 2.5±5.8 % for breast and lung, respectively). In SRS plans, our results showed good agreement compared to the action level. In SBRT plans, the discrepancy between the Indp was variable depending on dose calculation algorithms of TPS. Conclusion: The impact of dose calculation algorithms for the TPS and the Indp affects the action level. It is effective to set the site-specific tolerances, especially for the site where inhomogeneous correction can affect dose distribution strongly.

60 APPLIED LIFE SCIENCES↗

Initial experience of ArcCHECK and 3DVH software for RapidArc treatment plan verification

The purpose of this study was to perform delivery quality assurance with ArcCHECK and 3DVH system (Sun Nuclear, FL) and to evaluate the suitability of this system for volumetric-modulated arc therapy (VMAT) (RapidArc [RA]) verification. This software calculates the delivered dose distributions in patients by perturbing the calculated dose using errors detected in fluence or planar dose measurements. The device is tested to correlate the gamma passing rate (%GP) and the composite dose predicted by 3DVH software. A total of 28 patients with prostate cancer who were treated with RA were analyzed. RA treatments were delivered to a diode array phantom (ArcCHECK), which was used to create a planned dose perturbation (PDP) file. The 3DVH analysis used the dose differences derived from comparing the measured dose with the treatment planning system (TPS)-calculated doses to perturb the initial TPS-calculated dose. The 3DVH then overlays the resultant dose on the patient's structures using the resultant “PDP” beams. Measured dose distributions were compared with the calculated ones using the gamma index (GI) method by applying the global (Van Dyk) normalization and acceptance criteria, i.e., 3%/3 mm. Paired differences tests were used to estimate statistical significance of the differences between the composite dose calculated using 3DVH and %GP. Also, statistical correlation by means of logistic regression analysis has been analyzed. Dose-volume histogram (DVH) analysis for patient plans revealed small differences between treatment plan calculations and 3DVH results for organ at risk (OAR), whereas planning target volume (PTV) of the measured plan was systematically higher than that predicted by the TPS. The t-test results between the planned and the estimated DVH values showed that mean values were incomparable (p < 0.05). The quality assurance (QA) gamma analysis 3%/3 mm showed that in all cases there were only weak-to-moderate correlations (Pearson r: 0.12 to 0.74). Moreover, clinically relevant differences increased with increasing QA passing rate, indicating that some of the largest dose differences occurred in the cases of high QA passing rates, which may be called “false negatives.” The clinical importance of any disagreement between the measured and the calculated dose is often difficult to interpret; however, beam errors (either in delivery or in TPS calculation) can affect the effectiveness of the patient dose. Further research is needed to determinate the role of a PDP-type algorithm to accurately estimate patient dose effect.

61 RADIATION PROTECTION AND DOSIMETRY↗

From Sim to Real: A Pipeline for Training and Deploying Traffic Smoothing Cruise Controllers

Designing and validating controllers for connected and automated vehicles to enhance traffic flow presents significant challenges, from the complexity of replicating real-world stop-and-go traffic dynamics in simulation, to the intricacies involved in transitioning from simulation to actual deployment. In this work, we present a full pipeline from data collection to controller deployment. Specifically, we collect 772 km of driving data from the I-24 in Tennessee, and use it to build a one-lane simulator, placing simulated vehicles behind real-world trajectories. Using policy-gradient methods with an asymmetric critic, we improve fuel efficiency by over 10% when simulating congested scenarios. Our comprehensive approach includes reinforcement learning for controller training, software verification, hardware validation and setup, and navigating various sim-to-real challenges. Furthermore, we analyze the controller's behavior and wave-smoothing properties, and deploy it on four Toyota Rav4’s in a real-world validation experiment on the I-24. Lastly, we release the driving dataset, the simulator and the trained controller, to enable future benchmarking and controller design.

42 ENGINEERING↗

Development of a 3D optical scanning-based automatic quality assurance system for proton range compensators

Purpose: A new automatic quality assurance (AutoRCQA) system using a three-dimensional scanner (3DS) with system automation was developed to improve the accuracy and efficiency of the quality assurance (QA) procedure for proton range compensators (RCs). The system performance was evaluated for clinical implementation. Methods: The AutoRCQA system consists of a three-dimensional measurement system (3DMS) based on 3DS and in-house developed verification software (3DVS). To verify the geometrical accuracy, the planned RC data (PRC), calculated with the treatment planning system (TPS), were reconstructed and coregistered with the measured RC data (MRC) based on the beam isocenter. The PRC and MRC inner surfaces were compared with composite analysis (CA) using 3DVS, using the CA pass rate for quantitative analysis. To evaluate the detection accuracy of the system, the authors designed a fake PRC by artificially adding small cubic islands with side lengths of 1.5, 2.5, and 3.5 mm on the inner surface of the PRC and performed CA with the depth difference and distance-to-agreement tolerances of [1 mm, 1 mm], [2 mm, 2 mm], and [3 mm, 3 mm]. In addition, the authors performed clinical tests using seven RCs [computerized milling machine (CMM)-RCs] manufactured by CMM, which were designed for treating various disease sites. The systematic offsets of the seven CMM-RCs were evaluated through the automatic registration function of AutoRCQA. For comparison with conventional technique, the authors measured the thickness at three points in each of the seven CMM-RCs using a manual depth measurement device and calculated thickness difference based on the TPS data (TPS-manual measurement). These results were compared with data obtained from 3DVS. The geometrical accuracy of each CMM-RC inner surface was investigated using the TPS data by performing CA with the same criteria. The authors also measured the net processing time, including the scan and analysis time. Results: The AutoRCQA system accurately detected all fake objects in accordance with the given criteria. The median systematic offset of the seven CMM-RCs was 0.08 mm (interquartile range: −0.25 to 0.37 mm) and −0.08 mm (−0.58 to 0.01 mm) in the X- and Y-directions, respectively, while the median distance difference was 0.37 mm (0.23–0.94 mm). The median thickness difference of the TPS-manual measurement at points 1, 2, and 3 was −0.4 mm (−0.4 to −0.2 mm), −0.2 mm (−0.3 to 0.0 mm), and −0.3 mm (−0.6 to −0.1 mm), respectively, while the median difference of 3DMS was 0.0 mm (−0.1 to 0.2 mm), 0.0 mm (−0.1 to 0.3 mm), and 0.1 mm (−0.1 to 0.2 mm), respectively. Thus, 3DMS showed slightly better values compared to the manual measurements for points 1 and 3 in statistical analysis (p < 0.05). The average pass rate of the seven CMM-RCs was 97.97% ± 1.68% for 1-mm CA conditions, increasing to 99.98% ± 0.03% and 100% ± 0.00% for 2- and 3-mm CA conditions, respectively. The average net analysis time was 18.01 ± 1.65 min. Conclusions: The authors have developed an automated 3DS-based proton RC QA system and verified its performance. The AutoRCQA system may improve the accuracy and efficiency of QA for RCs.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-355: Efficient Scatter Correction for Direct Ray-Tracing Based Dose Calculation

Purpose: To propose a scatter correction method with linear computational complexity for direct-ray-tracing (DRT) based dose calculation. Due to its speed and simplicity, DRT is widely used as a dose engine in the treatment planning system (TPS) and monitor unit (MU) verification software, where heterogeneity correction is applied by radiological distance scaling. However, such correction only accounts for attenuation but not scatter difference, causing the DRT algorithm less accurate than the model-based algorithms for small field size in heterogeneous media. Methods: Inspired by the convolution formula derived from an exponential kernel as is typically done in the collapsed-cone-convolution-superposition (CCCS) method, we redesigned the ray tracing component as the sum of TERMA scaled by a local deposition factor, which is linear with respect to density, and dose of the previous voxel scaled by a remote deposition factor, D(i)=aρ(i)T(i)+(b+c(ρ(i)-1))D(i-1),where T(i)=e(-αr(i)+β(r(i))2) and r(i)=Σ-(j=1,..,i)ρ(j).The two factors together with TERMA can be expressed in terms of 5 parameters, which are subsequently optimized by curve fitting using digital phantoms for each field size and each beam energy. Results: The proposed algorithm was implemented for the Fluence-Convolution-Broad-Beam (FCBB) dose engine and evaluated using digital slab phantoms and clinical CT data. Compared with the gold standard calculation, dose deviations were improved from 20% to 2% in the low density regions of the slab phantoms for the 1-cm field size, and within 2% for over 95% of the volume with the largest discrepancy at the interface for the clinical lung case. Conclusion: We developed a simple recursive formula for scatter correction for the DRT-based dose calculation with much improved accuracy, especially for small field size, while still keeping calculation to linear complexity. The proposed calculator is fast, yet accurate, which is crucial for dose updating in IMRT optimization.

60 APPLIED LIFE SCIENCES↗

SU-F-T-609: Impact of Dosimetric Variation for Prescription Dose Using Analytical Anisotropic Algorithm (AAA) in Lung SBRT

Purpose: Actual irradiated prescription dose to patients cannot be verified. Thus, independent dose verification and second treatment planning system are used as the secondary check. AAA dose calculation engine has contributed to lung SBRT. We conducted a multi-institutional study to assess variation of prescription dose for lung SBRT when using AAA in reference to using Acuros XB and Clarkson algorithm. Methods: Six institutes in Japan participated in this study. All SBRT treatments were planed using AAA in Eclipse and Adaptive Convolve (AC) in Pinnacle3. All of the institutes used a same independent dose verification software program (Simple MU Analysis: SMU, Triangle Product, Ishikawa, Japan), which implemented a Clarkson-based dose calculation algorithm using CT image dataset. A retrospective analysis for lung SBRT plans (73 patients) was performed to compute the confidence limit (CL, Average±2SD) in dose between the AAA and the SMU. In one of the institutes, a additional analysis was conducted to evaluate the variations between the AAA and the Acuros XB (AXB). Results: The CL for SMU shows larger systematic and random errors of 8.7±9.9 % for AAA than the errors of 5.7±4.2 % for AC. The variations of AAA correlated with the mean CT values in the voxels of PTV (a correlation coefficient : −0.7) . The comparison of AXB vs. AAA shows smaller systematic and random errors of −0.7±1.7%. The correlation between dose variations for AXB and the mean CT values in PTV was weak (0.4). However, there were several plans with more than 2% deviation of AAPM TG114 (Maximum: −3.3 %). Conclusion: In comparison for AC, prescription dose calculated by AAA may be more variable in lung SBRT patient. Even AXB comparison shows unexpected variation. Care should be taken for the use of AAA in lung SBRT. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗

The National Solar Permitting Database

"The soft costs of solar — costs not associated with hardware — remain stubbornly high. Among the biggest soft costs are those associated with inefficiencies in local permitting and inspection. A study by the National Renewable Energy Laboratory and Lawrence Berkeley National Laboratory estimates that these costs add an average of $0.22/W per residential installation. This project helps reduce non-hardware/balance of system (BOS) costs by creating and maintaining a free and available site of permitting requirements and solar system verification software that installers can use to reduce time, capital, and resource investments in tracking permitting requirements. Software tools to identify best permitting practices can enable government stakeholders to optimize their permitting process and remove superfluous costs and requirements. Like ""a Wikipedia for solar permitting"", users can add, edit, delete, and update information for a given jurisdiction. We incentivize this crowdsourcing approach by recognizing users for their contributions in the form of SEO benefits to their company or organization by linking back to users' websites."

Gunderson, Renic↗

Tardigrade-examples V0.1.0

Tardigrade-examples is a repository of computational workflows that exercise the Tardigrade software package. The Tardigrade software package is an implementation of Eringen’s micromorphic continuum theory with capabilities to support multiscale material modeling. These capabilities include homogenization through the Micromorphic Filter, calibration of micromorphic material models, and macroscale simulation in Tardigrade-MOOSE. This repository investigates continuum upscaling of various direct numerical simulations (DNS) conducted in Abaqus finite element (FE), Ratel FE, and GEOS material point method (MPM) software. Verification of the upscaling workflow is first investigated by considering DNS of trivial stress states for homogeneous materials, results of which indicate that classical continuum behavior is recovered as expected. DNS of heterogeneous materials are then considered.

Allard, Thomas↗

An open-access simulated earthquake ground-motion database for an M7 Hayward Fault earthquake in the San Francisco Bay Region

Comprehensive understanding of earthquake ground motions, particularly in the near-fault region of large-magnitude events, is limited by gaps in strong-motion data. This challenge is prominent in areas with high seismic hazard but infrequent large earthquakes where data is sparse and difficult to interpret. These data limitations lead to uncertainties in the development of site-specific ground motions, which are crucial for engineering risk assessments. To address these challenges, physics-based regional-scale ground-motion simulations have been developed. With the emergence of exaflop-scale computing ecosystems, it is now possible to simulate regional earthquake processes at unprecedented fidelity and generate the large number of fault rupture realizations necessary to characterize both intra- and inter-event ground-motion variability. This article introduces a new database of simulated earthquake ground motions, created for applications in earthquake engineering, earthquake planning, and emergency response. The inaugural version of the database features simulated ground motions for a magnitude 7 Hayward Fault earthquake in the San Francisco Bay Region (SFBR), using the EarthQuake SIMulation (EQSIM) simulation framework and the Graves–Pitarka kinematic rupture model. The aim is to provide high-fidelity, spatially dense, three-component motions generated on the Department of Energy’s (DOE) newest generation of graphics processing unit (GPU)-accelerated supercomputers. These motions are being made openly available to the engineering, scientific, and disaster planning communities. In addition, this work develops protocols for the efficient dissemination of these large data sets and emphasizes community engagement to build confidence in their application. This article discusses the methodology behind the data, underlying software verification and validation, scalable data management, and a user interface for data access. The goal is to facilitate widespread use and elicit expert feedback to maximize the utility and exploitation of simulated motions. While the initial focus is on the San Francisco Region, simulations for additional regions will be added as the DOE program progresses.

Simulated ground-motion database↗

Integral and Separate Effects Tests for Thermal Hydraulics Code Validation for Liquid-Salt Cooled Nuclear Reactors

The objective of the 3-year project was to collect integral effects test (IET) data to validate the RELAP5-3D code and other thermal hydraulics codes for use in predicting the transient thermal hydraulics response of liquid salt cooled reactor systems, including integral transient response for forced and natural circulation operation. The reference system for the project is a modular, 900-MWth Pebble Bed Advanced High Temperature Reactor (PB-AHTR), a specific type of Fluoride salt-cooled High temperature Reactor (FHR). Two experimental facilities were developed for thermal-hydraulic integral effects tests (IETs) and separate effects tests (SETs). The facilities use simulant fluids for the liquid fluoride salts, with very little distortion to the heat transfer and fluid dynamics behavior. The CIET Test Bay facility was designed, built, and operated. IET data for steady state and transient natural circulation was collected. SET data for convective heat transfer in pebble beds and straight channel geometries was collected. The facility continues to be operational and will be used for future experiments, and for component development. The CIET 2 facility is larger in scope, and its construction and operation has a longer timeline than the duration of this grant. The design for the CIET 2 facility has drawn heavily on the experience and data collected on the CIET Test Bay, and it was completed in parallel with operation of the CIET Test Bay. CIET 2 will demonstrate start-up and shut-down transients and control logic, in addition to LOFC and LOHS transients, and buoyant shut down rod operation during transients. Design of the CIET 2 Facility is complete, and engineering drawings have been submitted to an external vendor for outsourced quality controlled construction. CIET 2 construction and operation continue under another NEUP grant. IET data from both CIET facilities is to be used for validation of system codes used for FHR modeling, such as RELAP5-3D. A set of numerical models were developed in parallel to the experimental work. RELAP5-3D models were developed for the salt-cooled PB-AHTR, and for the simulat fluid CIET natural circulation experimental loop. These models are to be validated by the data collected from CIET. COMSOL finite element models were used to predict the temperature and fluid flow distribution in the annular pebble bed core; they were instrumental for design of SETs, and they can be used for code-to-code comparisons with RELAP5-3D. A number of other small SETs, and numerical models were constructed, as needed, in support of this work. The experiments were designed, constructed and performed to meet CAES quality assurance requirements for test planning, implementation, and documentation; equipment calibration and documentation, procurement document control; training and personnel qualification; analysis/modeling software verification and validation; data acquisition/collection and analysis; and peer review.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Detecting Data-Races in High-Performance Computing

High-performance computing is susceptible to data-race bugs. Data races occur when sequences of computed events do not happen in the intended order, a significant barrier to the integrity of parallel programs using shared-memory architectures. Many approaches to data-race detection are based on traditional static-analysis techniques that typically execute on a program’s source code or control-flow graph (the graphical representation of all possible orders of events in the execution of a program). Similar to classical data-flow analyses, such tools can produce false alarms that report spurious race conditions on error free programs. We have developed a software verification technique that requires as input only a program’s source code and can automatically detect a data-race bug which definitely exists, determine that a program is definitely data-race free, or report that it cannot determine either of the two cases.

97 MATHEMATICS AND COMPUTING↗